Atch_12_Sample-_AF_Form_3052.xls
XLS spreadsheet 105 KB Posted
- Attached to
- Convert bldg 62 back into Aircraft MX Hanagr Federal contract opportunity
- Solicitation number
- A001645
About this file
Sample Cost Estimate Breakdown
View the file
Other files for this federal contract opportunity
Show all 31
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Details
| CONSTRUCTION COST ESTIMATE BREAKDOWN | ||||||||||
| CONTRACTOR | ADDRESS: | |||||||||
| General Construction Subtotal | ||||||||||
| 502 Civil Engineering Squadron | General Construction Labor Burden | |||||||||
| Prepared by: Olugbenga J Falomo | 100.00% | RSMeans San Antonio, TX CCI | ||||||||
| General Construction Subcontractor Overhead | ||||||||||
| General Construction Subcontractor Profit | ||||||||||
| Prepared by: Jeffery C. Parks II | General Construction Prime Contractor Overhead | |||||||||
| General Construction Prime Contractor Profit | ||||||||||
| General Construction Prime Contractor Bonding | ||||||||||
| General Construction Contingency | ||||||||||
| CONTRACT FOR (Work to be performed) | This cost proposal is valid for ____________365__________________days | Proposed Project Amount | ||||||||
| Convert B62 Back to Aircraft MX Hangar | The period of performance to perform this work is ____130_______ days. | |||||||||
| PURCHASE REQUEST NUMBER | PROJECT NUMBER | WORK LOCATION | ||||||||
| F2M3CB8334AW01 | TYMX180010 | JBSA - Randolph | ||||||||
| LINE | ||||||||||
| NO. | ITEM DESCRIPTION | UNIT OF | ||||||||
| MEASURE | MATERIAL COSTS | LABOR COSTS | EQUIPMENT COSTS | OTHER COSTS | LINE |
TOTAL
| 100000 | $0.00 | $0.00 | $0.00 | $0.00 | $0.00 | RSM16eMCOM B | ||||
| 2 | 01-11-31-10-0100 Architectural fees, for alteration work, to $500,000, add to new construction fee | Project | $0.00 | 0 | $0.00 | $0.00 | $0.00 | $0.00 | RSM16eMCOM B | |
| 3 | 01-11-31-20-0060 Construction management fees, for work to $100,000 | Project | $0.00 | 0 | $0.00 | $0.00 | $0.00 | $0.00 | RSM16eFAC B | |
| 4 | 01-11-31-20-0060 Construction management fees, for work to $100,000 | Project | $0.00 | 0 | $0.00 | $0.00 | $0.00 | $0.00 | RSM16eFAC B | |
| 5 | 01-11-31-30-0200 Engineering fees, electrical, minimum | Contrct | $0.00 | 0 | $0.00 | $0.00 | $0.00 | $0.00 | RSM16eMCOM B | |
| 6 | 01-11-31-30-0200 Engineering fees, electrical, minimum | Contrct | $0.00 | 0 | $0.00 | $0.00 | $0.00 | $0.00 | RSM16eMCOM B | |
| 7 | 01-11-31-30-0900 Engineering fees, landscaping and site development, maximum | Contrct | $0.00 | 0 | $0.00 | $0.00 | $0.00 | $0.00 | RSM16eMCOM B | |
| 8 | 01-21-53-50-0850-L Factors, cost adjustments, add to construction costs for particular job requirements, dust protection, add, maximum | Costs | $0.00 | 0 | $0.00 | $0.00 | $0.00 | $0.00 | RSM16eMCOM B | |
| 9 | 01-21-53-50-0850-L Factors, cost adjustments, add to construction costs for particular job requirements, dust protection, add, maximum | Costs | $0.00 | 0 | $0.00 | $0.00 | $0.00 | $0.00 | RSM16eMCOM B | |
| 10 | 01-31-13-20-0020 Field personnel, clerk, average | Week | $0.00 | 0 | $0.00 | $0.00 | $0.00 | $0.00 | RSM16eMCOM B | |
| 11 | 01-31-13-20-0020 Field personnel, clerk, average | Week | $0.00 | 0 | $0.00 | $0.00 | $0.00 | $0.00 | RSM16eMCOM B | |
| 12 | 01-31-13-20-0020 Field personnel, clerk, average | Week | $0.00 | 0 | $0.00 | $0.00 | $0.00 | $0.00 | RSM16eMCOM B | |
| 13 | 01-31-13-20-0100 Field personnel, field engineer, minimum | Week | $0.00 | 0 | $0.00 | $0.00 | $0.00 | $0.00 | RSM16eMCOM B | |
| 14 | 01-31-13-20-0100 Field personnel, field engineer, minimum | Week | $0.00 | 0 | $0.00 | $0.00 | $0.00 | $0.00 | RSM16eMCOM B | |
| 15 | 01-31-13-20-0100 Field personnel, field engineer, minimum | Week | $0.00 | 0 | $0.00 | $0.00 | $0.00 | $0.00 | RSM16eMCOM B | |
| 16 | 01-31-13-20-0120 Field personnel, field engineer, average | Week | $0.00 | 0 | $0.00 | $0.00 | $0.00 | $0.00 | RSM16eFAC B | |
| 17 | 01-31-13-20-0160 Field personnel, general purpose laborer, average | Week | $0.00 | 0 | $0.00 | $0.00 | $0.00 | $0.00 | RSM16eMCOM B | |
| 18 | 01-31-13-20-0160 Field personnel, general purpose laborer, average | Week | RSM16eMCOM B | |||||||
| 19 | 01-31-13-20-0180 Field personnel, project manager, minimum | Week | RSM16eFAC B | |||||||
| 20 | 01-31-13-20-0180 Field personnel, project manager, minimum | Week | RSM16eFAC B | |||||||
| 21 | 01-31-13-20-0220 Field personnel, project manager, maximum | Week | RSM16eMCOM B | |||||||
| 22 | 01-31-13-20-0240 Field personnel, superintendent, minimum | Week | RSM16eFAC B | |||||||
| 23 | 01-31-13-20-0240C Field personnel, Quality Control, minimum | Week | CUSTOM B | |||||||
| 24 | 01-31-13-20-0240C Field personnel, Quality Control, minimum | Week | CUSTOM B | |||||||
| 25 | 01-31-13-20-0260 Field personnel, superintendent, average | Week | RSM16eMCOM B | |||||||
| 26 | 01-31-13-20-0280 Field personnel, superintendent, maximum | Week | RSM16eMCOM B | |||||||
| 27 | 01-31-13-30-0200 Insurance, all-risk type, minimum | Job | RSM16eFAC B | |||||||
| 28 | 01-31-13-30-0200 Insurance, all-risk type, minimum | Job | RSM16eFAC B | |||||||
| 29 | 01-32-13-50-0700 Scheduling, rule of thumb, CPM scheduling, including cost control, small job, $10,000,000 | Job | RSM16eFAC B | |||||||
| 30 | 01-32-33-50-0020 Photographs, 8" x 10", 4 shots, 2 prints each, standard mounting | Set | RSM16eFAC B | |||||||
| 31 | 01-32-33-50-0020 Photographs, 8" x 10", 4 shots, 2 prints each, standard mounting | Set | RSM16eFAC B | |||||||
| 32 | 01-32-33-50-0020-0300 Photographs, for I.D. slugs, add to all above (Modified using 01-32-33-50-0300) | Set | RSM16eFAC B | |||||||
| 33 | 01-32-33-50-0020-0300 Photographs, for I.D. slugs, add to all above (Modified using 01-32-33-50-0300) | Set | RSM16eFAC B | |||||||
| 34 | 01-45-23-50-4720 Testing and inspecting services, soil testing, density and classification of undisturbed sample | Ea. | RSM16eMCOM B | |||||||
| 35 | 01-45-23-50-4735 Testing and inspecting services, soil testing, soil density, nuclear method, ASTM D2922 | Ea. | RSM16eMCOM B | |||||||
| 36 | 01-45-23-50-5570 Testing and inspecting services, technician for inspection, per day, concrete | Ea. | RSM16eMCOM B | |||||||
| 37 | 01-51-13-50-0030 Temporary power equip (pro-rated per job), service, overhead feed, 3 use, 100 Amp | Ea. | RSM16eMCOM B | |||||||
| 38 | 01-52-13-20-0020-0890 Office and storage space, for delivery, delivery each way (Modified using 01-52-13-20-0890) | Ea. | RSM16eFAC B | |||||||
| 39 | 01-52-13-20-0350 Office and storage space, office trailer, furnished, no hookups, 32' x 8', rent per month | Ea. | RSM16eFAC B | |||||||
| 40 | 01-52-13-20-0450 Office and storage space, office trailer, furnished, no hookups, 50' x 10', rent per month | Ea. | RSM16eMCOM B | |||||||
| 41 | 01-52-13-20-0450-0700 Office and storage space, for air conditioning, rent per month, add (Modified using 01-52-13-20-0700) | Ea. | RSM16eMCOM B | |||||||
| 42 | 01-52-13-20-0450-0890 Office and storage space, for delivery, delivery each way (Modified using 01-52-13-20-0890) | Ea. | RSM16eMCOM B | |||||||
| 43 | 01-52-13-20-0450-0890 Office and storage space, for delivery, delivery each way (Modified using 01-52-13-20-0890) | Ea. | RSM16eMCOM B | |||||||
| 44 | 01-52-13-20-0500-0800 Office and storage space, for delivery, add per mile (Modified using 01-52-13-20-0800) | Mile | RSM16eMCOM B | |||||||
| 45 | 01-52-13-20-0500-0800 Office and storage space, for delivery, add per mile (Modified using 01-52-13-20-0800) | Mile | RSM16eMCOM B | |||||||
| 46 | 01-52-13-20-1300 Office and storage space, storage boxes, 40' x 8', buy | Ea. | RSM16eMCOM B | |||||||
| 47 | 01-52-13-20-1300 Office and storage space, storage boxes, 40' x 8', buy | Ea. | RSM16eMCOM B | |||||||
| 48 | 01-52-13-40-0100 Field office expense, office equipment rental, average | Month | RSM16eMCOM B | |||||||
| 49 | 01-52-13-40-0100 Field office expense, office equipment rental, average | Month | RSM16eMCOM B | |||||||
| 50 | 01-52-13-40-0120 Field office expense, office supplies, average | Month | RSM16eMCOM B | |||||||
| 51 | 01-52-13-40-0120 Field office expense, office supplies, average | Month | RSM16eMCOM B | |||||||
| 52 | 01-52-13-40-0140 Field office expense, telephone bill, average bill per month including long distance | Month | RSM16eMCOM B | |||||||
| 53 | 01-52-13-40-0140 Field office expense, telephone bill, average bill per month including long distance | Month | RSM16eMCOM B | |||||||
| 54 | 01-52-13-40-0160 Field office expense, lights and HVAC | Month | RSM16eMCOM B | |||||||
| 55 | 01-52-13-40-0160 Field office expense, lights and HVAC | Month | RSM16eMCOM B | |||||||
| 56 | 01-54-16-50-0100 Weekly forklift crew, all-terrain forklift, 45' lift, 35' reach, 9000 lbs. capacity | Week | RSM16eMCOM B | |||||||
| 57 | 01-54-33-40-0160-3 Rent per week for general equipment rental, without operators, aerial lift, scissor type, electric, to 25' high, 2000 lbs. capacity | Ea. | RSM16eFAC B | |||||||
| 58 | 01-54-33-40-0160-3 Rent per week for general equipment rental, without operators, aerial lift, scissor type, electric, to 25' high, 2000 lbs. capacity | Ea. | RSM16eFAC B | |||||||
| 59 | 01-54-33-40-6410-4 Rent per month for general equipment rental, without operators, toilet, portable chemical | Ea. | RSM16eMCOM B | |||||||
| 60 | 01-54-36-50-0020 Mobilization, up to 25 mile haul distance, 50 miles round trip for mobilization or demobilization crew, dozer, loader, backhoe, excavator, grader, paver, roller, 70 to 150 H.P. | Ea. | RSM14MCOM B | |||||||
| 61 | 01-54-36-50-0020-2500 Mobilization, for each additional 5 miles haul distance, add (Modified using 01-54-36-50-2500) | Ea. | RSM14MCOM B | |||||||
| 62 | 01-54-36-50-0020-2500 Mobilization, for each additional 5 miles haul distance, add (Modified using 01-54-36-50-2500) | Ea. | RSM14MCOM B | |||||||
| 63 | 01-54-36-50-0100 Mobilization, up to 25 mile haul distance, 50 miles round trip for mobilization or demobilization crew, dozer, loader, backhoe, excavator, grader, paver, roller, above 150 H.P. | Ea. | RSM14MCOM B | |||||||
| 64 | 01-54-36-50-1200 Mobilization, up to 25 mile haul distance, 50 miles round trip for mobilization or demobilization crew, small equipment, placed in rear of, or towed by pickup truck | Ea. | RSM16eMCOM B | |||||||
| 65 | 01-54-36-50-1200 Mobilization, up to 25 mile haul distance, 50 miles round trip for mobilization or demobilization crew, small equipment, placed in rear of, or towed by pickup truck | Ea. | RSM16eMCOM B | |||||||
| 66 | 01-54-36-50-1200-2500 Mobilization, for each additional 5 miles haul distance, add (Modified using 01-54-36-50-2500) | Ea. | RSM16eMCOM B | |||||||
| 67 | 01-54-36-50-1200-2500 Mobilization, for each additional 5 miles haul distance, add (Modified using 01-54-36-50-2500) | Ea. | RSM16eMCOM B | |||||||
| 68 | 01-54-36-50-1200-2500 Mobilization, for each additional 5 miles haul distance, add (Modified using 01-54-36-50-2500) | Ea. | RSM16eMCOM B | |||||||
| 69 | 01-54-36-50-1200-2500 Mobilization, for each additional 5 miles haul distance, add (Modified using 01-54-36-50-2500) | Ea. | RSM16eMCOM B | |||||||
| 70 | 01-74-13-20-0020 Cleaning up, after job completion, allow, minimum | Job | RSM16eMCOM B | |||||||
| 71 | 01-74-13-20-0020 Cleaning up, after job completion, allow, minimum | Job | RSM16eMCOM B | |||||||
| 72 | 01-74-13-20-0050 Cleaning up, cleanup of floor area, continuous, per day, during construction | M.S.F. | RSM16eMCOM B | |||||||
| 73 | 01-74-13-20-0052 Cleaning up, cleanup of floor area, continuous, per day, during construction | M.S.F. | RSM16eFAC B | |||||||
| 74 | 01-74-13-20-0100 Cleaning up, cleanup of floor area, final by General Contractor at end of job | M.S.F. | RSM16eMCOM B | |||||||
| 75 | 01-76-13-20-0020 Temporary protection, flooring, 1/8" tempered hardboard, taped seams | S.F. | RSM16eFAC B | |||||||
| 76 | 01-91-13-50-0200 Building commissioning, systems design assistance, operation, verification and training | % | RSM16eFAC B | |||||||
| 77 | 01-91-13-50-0200 Building commissioning, systems design assistance, operation, verification and training | % | RSM16eFAC B | |||||||
| 78 | 02-03-35-1C Removal of pre-existing coatings, paint, epoxy, 1 coat | MSF | CUSTOM B | |||||||
| 79 | 02-03-35-2C Polished concrete floors, polishing and edging, 1500 grit diamond | MSF | CUSTOM B | |||||||
| 80 | 02-03-35-3C Finishing floors, heavy duty, floor hardener, heavy service | S.F. | CUSTOM B | |||||||
| 81 | 02-03-35-4C Control joints, remove existing sealant, blow construction debris out of control joint | L.F. | CUSTOM B | |||||||
| 82 | 02-03-35-5C Control joints, remove existing sealant, blow construction debris out of control joint | L.F. | CUSTOM B | |||||||
| 83 | 02-03-35-6C Control joints, joint sealant, polyurethane, 3" x 1/2" (154 L.F. per gallon) | L.F. | CUSTOM B | |||||||
| 84 | 02-41-13-30-4200 Minor site demolition, excluding hauling, sidewalk removal, concrete, mesh reinforced, 4" thick | S.Y. | RSM16eMCOM B | |||||||
| 85 | 02-41-13-30-4200-4400 Minor site demolition, for congested sites or small quantities, add up to (Modified using 02-41-13-30-4400) | C.Y. | RSM16eMCOM B | |||||||
| 86 | 02-41-13-30-4200-4500 Minor site demolition, for disposal up to 5 miles, add (Modified using 02-41-13-30-4500) | C.Y. | RSM16eMCOM B | |||||||
| 87 | 02-41-13-30-4200-4500 Minor site demolition, for disposal up to 5 miles, add (Modified using 02-41-13-30-4500) | C.Y. | RSM16eMCOM B | |||||||
| 88 | 02-41-13-98-0100 Selective demolition, sod, edging, planters & tree guying, remove sod, 1" deep, level ground, 3 M.S.F. or greater | M.S.F. | RSM16eMCOM B | |||||||
| 89 | 02-82-13-41-1750 Asbestos abatement equipment, equipment and supplies, buy, vacuum cleaner, HEPA, stainless steel, wet and dry, 16 gallon | Ea. | RSM16eFAC B | |||||||
| 90 | 02-82-13-41-6000 Asbestos abatement equipment, equipment and supplies, buy, disposable polyethylene bags, 6 mil, 3 C.F. | Ea. | RSM16eMCOM B | |||||||
| 91 | 02-82-13-43-8250 Bulk asbestos removal, includes disposable tools and 2 suits and 1 respirator filter per day per worker, shingle roofing, built-up, no gravel, non-friable | S.F. | RSM16eMCOM B | |||||||
| 92 | 02-83-19-21-0100 Lead paint remediation plans and methods, building survey commercial building | Ea. | RSM16eMCOM B | |||||||
| 93 | 02-83-19-21-0200 Lead paint remediation plans and methods, lead abatement remediation plan | Ea. | RSM16eMCOM B | |||||||
| 94 | 02-83-19-21-0300 Lead paint remediation plans and methods, lead paint testing, AAS analysis | Ea. | RSM16eMCOM B | |||||||
| 95 | 03-30-53-40-4050 Concrete in place, including forms, 4 uses, Grade 60 rebar, portland cement Type I, placement and finishing unless otherwise indicated, foundation mat, 3000 PSI, over 20 C.Y. | C.Y. | RSM16eMCOM B | |||||||
| 96 | 03-30-53-40-4050 Concrete in place, including forms, 4 uses, Grade 60 rebar, portland cement Type I, placement and finishing unless otherwise indicated, foundation mat, 3000 PSI, over 20 C.Y. | C.Y. | RSM16eMCOM B | |||||||
| 97 | 04-01-20-20-0300 Pointing masonry, cut and repoint brick, hard mortar, running bond | S.F. | RSM16eMCOM B | |||||||
| 98 | 04-02-82-1C OSHA testing, certified technician, maximum | Ea. | CUSTOM B | |||||||
| 99 | 04-02-82-2C OSHA testing, cleaned area samples, PCM air sample analysis, NIOSH 7400, minimum | Ea. | CUSTOM B | |||||||
| 100 | 04-02-83-1C OSHA testing, cleaned area samples, PCM air sample analysis, NIOSH 7400, minimum | L.F. | CUSTOM B | |||||||
| 101 | 04-03-83-2C TCLP LBP & Disposal | SF | CUSTOM B | |||||||
| 102 | 04-03-83-4C Painted pavement markings, waterborne, white or yellow, 6" wide | L.F. | CUSTOM B | |||||||
| 103 | 05-58-23-90-0025 Window guards, shop fabricated, using steel bars, 1/2" x 1/2", spaced 5" O.C. | S.F. | RSM16eFAC Grn, B | |||||||
| 104 | 05-73-23-50-0400 Railings, ornamental, shop fabricated, 3'-6" high, posts at 6' O.C., wrought iron, hand forged, plain | L.F. | RSM16eMCOM Grn, B | |||||||
| 105 | 05-73-23-50-0400 Railings, ornamental, shop fabricated, 3'-6" high, posts at 6' O.C., wrought iron, hand forged, plain | L.F. | RSM16eMCOM Grn, B | |||||||
| 106 | 07-05-05-10-1325 R&R - Selective demolition, thermal and moisture protection, roof accessories, plumbing vent flashing | Ea. | CUSTOM O&P | |||||||
| 107 | 07-05-05-10-1325 R&R - Selective demolition, thermal and moisture protection, roof accessories, plumbing vent flashing | Ea. | CUSTOM O&P | |||||||
| 108 | 07-05-05-10-1375 Selective demolition, thermal and moisture protection, roof accessories, ridge vent strip, aluminum | L.F. | RSM16eFAC B | |||||||
| 109 | 07-05-05-10-1375 Selective demolition, thermal and moisture protection, roof accessories, ridge vent strip, aluminum | L.F. | RSM16eFAC B | |||||||
| 110 | 07-05-05-10-2520 Selective demolition, thermal and moisture protection, roof insulation board, up to 2" thick | S.F. | RSM16eMCOM B | |||||||
| 111 | 07-05-05-10-4820 Selective demolition, thermal and moisture protection, roofing, single ply membrane, sheet metal roofing | S.F. | RSM16eMCOM B | |||||||
| 112 | 07-21-13-10-0120 Rigid insulation, for walls, fiberglass, 1.5 lbs per C.F., unfaced, 3" thick, R12.4 | S.F. | RSM16eFAC Grn, B | |||||||
| 113 | 07-21-13-10-0120 R&R - Rigid insulation, for walls, fiberglass, 1.5 lbs per C.F., unfaced, 3" thick, R12.4 | S.F. | CUSTOM Grn, O&P | |||||||
| 114 | 07-21-13-10-1700 Rigid insulation, for walls, perlite, 1" thick, R2.77 | S.F. | RSM16eMCOM Grn, B | |||||||
| 115 | 07-21-13-10-1900 Rigid insulation, for walls, extruded polystyrene, 25 PSI compressive strength, 1" thick, R5 | S.F. | RSM16eMCOM Grn, B | |||||||
| 116 | 07-31-13-10-0825 Asphalt roof shingles, #30 felt underlayment | Sq. | RSM16eMCOM B | |||||||
| 117 | 07-41-13-20-0530 Steel roofing panels, on steel frame, corrugated or ribbed, painted, including fasteners, 22 gauge | S.F. | RSM16eMCOM B | |||||||
| 118 | 07-41-13-20-1203 Steel roofing panels, on steel frame, ridge, galvanized, 14" wide | L.F. | RSM16eMCOM B | |||||||
| 119 | 07-65-10-10-0300 Sheet metal flashing and counter flashing, including up to 4 bends, aluminum, mill finish, .050" thick | S.F. | RSM16eMCOM B | |||||||
| 120 | 07-65-10-10-0300 Sheet metal flashing and counter flashing, including up to 4 bends, aluminum, mill finish, .050" thick | S.F. | RSM16eMCOM B | |||||||
| 121 | 07-65-10-10-0300-0400 Sheet metal flashing and counter flashing, painted finish, add (Modified using 07-65-10-10-0400) | S.F. | RSM16eMCOM B | |||||||
| 122 | 07-92-13-20-0600 Caulking and sealant options, latex acrylic based, white, 1/2" x 1/2" | L.F. | RSM16eMCOM B | |||||||
| 123 | 08-51-23-10-1500 Steel sash, custom units, excluding glazing and trim, industrial, horizontally pivoted | S.F. | RSM16eMCOM B | |||||||
| 124 | 08-51-23-10-1500 Demo - Steel sash, custom units, excluding glazing and trim, industrial, horizontally pivoted | S.F. | CUSTOM | |||||||
| 125 | 08-51-23-10-1500 Steel sash, custom units, excluding glazing and trim, industrial, horizontally pivoted | S.F. | RSM16eMCOM B | |||||||
| 126 | 08-51-23-10-1500 Demo - Steel sash, custom units, excluding glazing and trim, industrial, horizontally pivoted | S.F. | CUSTOM | |||||||
| 127 | 08-52-10-40-8100-8190 Casement window, for installation, add per leaf (Modified using 08-52-10-40-8190) | Ea. | RSM10FAC Grn, B | |||||||
| 128 | 08-52-13-20-0100 Casement windows, metal-clad, including frame, screen and grilles, deluxe, double insulated glass, 2'-0" x 3'-0" high | Ea. | RSM16eFAC Grn, B | |||||||
| 129 | 08-74-23-50-0360 Security access control accessories, scanner and/or reader access, power supply, transformer, 110 volt to 12/24 volt | Ea. | RSM16eFAC O&P | |||||||
| 130 | 08-74-23-50-0370 Security access control accessories, scanner and/or reader access, electric and mag strikers, 12/24 volt | Ea. | RSM16eFAC O&P | |||||||
| 131 | 08-74-23-50-0380 Security access control accessories, scanner and/or reader access, one hour battery backup power supply | Ea. | RSM16eFAC O&P | |||||||
| 132 | 08-74-23-50-0390 Security access control accessories, complete, including hardware, deadbolt, digital, battery operated, indoor or outdoor | Ea. | RSM16eFAC O&P | |||||||
| 133 | 08-75-30-10-0600 Mechanical weather seals, window, double hung, 3' X 5', heavy duty, bronze | Opng. | RSM16eFAC O&P | |||||||
| 134 | 08-79-13-10-0020 Key cabinets, wall mounted, 60 key capacity | Ea. | RSM16eFAC O&P | |||||||
| 135 | 08-79-20-10-2240 Door hardware accessories, mortise lockset, passage, lever handle | Ea. | RSM16eFAC O&P | |||||||
| 136 | 08-81-10-10-0020-8900 Various types and thickness of float glass, for low emissivity coating for 3/16" & 1/4" only, add to above (Modified using 08-81-10-10-8900) | S.F. | RSM16eFAC O&P | |||||||
| 137 | 08-81-10-10-0700 Various types and thickness of float glass, 1/4" thick, tinted | S.F. | RSM16eFAC O&P | |||||||
| 138 | 08-81-10-10-3600 Various types and thickness of float glass, 1" thick, clear, plain | S.F. | RSM16eFAC O&P | |||||||
| 139 | 08-81-13-10-0050 Beveled glass, with design patterns, 1/4" thick, 1/2" bevel, intricate pattern | S.F. | RSM16eFAC O&P | |||||||
| 140 | 08-81-17-10-0050 Fire resistant glass, fire glass, high end | S.F. | RSM16eFAC O&P | |||||||
| 141 | 08-81-20-10-9000 Full vision, minimum labor/equipment charge | Job | RSM16eFAC O&P | |||||||
| 142 | 09-05-05-10-1200 Demo - Selective demolition, ceilings, suspended ceiling, mineral fiber, 2' x 2' or 2' x 4' | S.F. | CUSTOM O&P | |||||||
| 143 | 09-05-05-10-1200 Selective demolition, ceilings, suspended ceiling, mineral fiber, 2' x 2' or 2' x 4' | S.F. | RSM16eFAC B | |||||||
| 144 | 09-05-05-10-1250 Selective demolition, ceilings, suspended ceiling, mineral fiber, on suspension system, including system | S.F. | RSM16eFAC B | |||||||
| 145 | 09-05-05-20-0400 Selective demolition, flooring, carpet, bonded, including surface scraping | S.F. | RSM16eFAC B | |||||||
| 146 | 09-05-05-20-0560 Selective demolition, flooring, carpet tile, permanent adhesive | S.F. | RSM16eMCOM B | |||||||
| 147 | 09-05-05-20-0850 Selective demolition, flooring, vinyl or rubber cove base | L.F. | RSM16eFAC B | |||||||
| 148 | 09-24-23-40-0015 Stucco, 3 coats 1" thick, float finish, with mesh, on wood frame | S.Y. | RSM16eMCOM B | |||||||
| 149 | 09-30-13-10-1500 Ceramic tile, sanitary cove base, 6" x 6" high, mud set | L.F. | RSM16eMCOM B | |||||||
| 150 | 09-30-13-10-1500 Ceramic tile, sanitary cove base, 6" x 6" high, mud set | L.F. | RSM16eMCOM B | |||||||
| 151 | 09-30-13-10-1500-4500 Ceramic tile, add for epoxy grout, 1/16" joint, 1" x 1" tile (Modified using 09-30-13-10-4500) | S.F. | RSM14MCOM B | |||||||
| 152 | 09-51-23-10-1125 Suspended acoustic ceiling tiles, excluding suspension system, mineral fiber tile, lay-in, 2' x 2' or 2' x 4', 3/4" thick, fine textured | S.F. | CUSTOM | |||||||
| 153 | 09-53-23-30-0300-0360 Ceiling suspension systems, for fire rated grid, add (Modified using 09-53-23-30-0360) | S.F. | RSM16eFAC B | |||||||
| 154 | 09-53-23-30-0300-0360 Ceiling suspension systems, for fire rated grid, add (Modified using 09-53-23-30-0360) | S.F. | RSM16eFAC B | |||||||
| 155 | 09-65-10-10-3600 Latex underlayment, latex underlayment, cementitious for resilient flooring, 1/8" thick | S.F. | RSM16eMCOM B | |||||||
| 156 | 09-65-13-13-1150 Resilient base, base, cove, rubber or vinyl, standard colors, 0.080" thick, 4" high | L.F. | RSM09MCOM B | |||||||
| 157 | 09-66-13-10-2710 Portland cement terrazzo, cast-in-place, monolithic terrazzo, 1/2" thick, 10' panels | S.F. | RSM16eMCOM B | |||||||
| 158 | 09-67-13-13-0100 Elastomeric liquid flooring, cementitous acrylic, 3/8" thick | S.F. | RSM16eMCOM B | |||||||
| 159 | 09-68-05-11-0107 Flooring transition strip, clamp down brass divider, 12' strip, vinyl to carpet | Ea. | RSM16eMCOM B | |||||||
| 160 | 09-68-13-10-0210 Carpet tile, tufted nylon, 18" x 18", cushion back, 26 ounce | S.Y. | RSM16eMCOM B | |||||||
| 161 | 09-91-23-72-1670 Walls and ceilings, interior, concrete, dry wall or plaster, painting walls, complete, including surface preparation, primer and two coats finish, on drywall or plaster, with roller | S.F. | RSM16eMCOM B | |||||||
| 162 | 09-91-23-72-1670 Walls and ceilings, interior, concrete, dry wall or plaster, painting walls, complete, including surface preparation, primer and two coats finish, on drywall or plaster, with roller | S.F. | RSM16eMCOM B | |||||||
| 163 | 21-05-23-50-6280 General-duty valves, for water based fire suppression piping, valves and components, alarm, includes, retard chamber, trim, gauges, alarm line strainer, 4" size | Ea. | RSM16eFAC B | |||||||
| 164 | 21-05-23-50-6280 General-duty valves, for water based fire suppression piping, valves and components, alarm, includes, retard chamber, trim, gauges, alarm line strainer, 4" size | Ea. | RSM16eFAC B | |||||||
| 165 | 21-05-23-50-6280-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC B | |||||||
| 166 | 21-05-23-50-6280-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC B | |||||||
| 167 | 21-05-23-50-6280-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC B | |||||||
| 168 | 21-05-23-50-6280-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC B | |||||||
| 169 | 21-11-13-18-0150 Pipe fittings, plastic, CPVC, fire suppression, (C-UL-S. FM, NFPA 13, 13D & 13R), socket joint, 90° elbow, 1-1/2" | Ea. | RSM16eFAC B | |||||||
| 170 | 21-11-13-18-0150 Pipe fittings, plastic, CPVC, fire suppression, (C-UL-S. FM, NFPA 13, 13D & 13R), socket joint, 90° elbow, 1-1/2" | Ea. | RSM16eFAC B | |||||||
| 171 | 21-11-13-18-0150-2100 Labor adjustment factors, add to labor for crawl space, 3' high (Modified using 22-01-02-20-2100) | Ea. | RSM16eFAC B | |||||||
| 172 | 21-11-13-18-0150-2100 Labor adjustment factors, add to labor for crawl space, 3' high (Modified using 22-01-02-20-2100) | Ea. | RSM16eFAC B | |||||||
| 173 | 21-11-13-18-0350 Pipe fittings, plastic, CPVC, fire suppression, (C-UL-S. FM, NFPA 13, 13D & 13R), socket joint, tee, 2" | Ea. | RSM16eFAC B | |||||||
| 174 | 21-11-13-18-0350 Pipe fittings, plastic, CPVC, fire suppression, (C-UL-S. FM, NFPA 13, 13D & 13R), socket joint, tee, 2" | Ea. | RSM16eFAC B | |||||||
| 175 | 21-11-19-50-7160 Connections for the fire-department, standpipe connections, wall, with plugs and chains, single, flush, brass, 2-1/2" x 2-1/2" | Ea. | RSM16eFAC B | |||||||
| 176 | 21-11-19-50-7160 Connections for the fire-department, standpipe connections, wall, with plugs and chains, single, flush, brass, 2-1/2" x 2-1/2" | Ea. | RSM16eFAC B | |||||||
| 177 | 21-13-13-50-1220 Wet-pipe sprinkler system components, alarm, electric pressure switch, water motor, complete with gong | Ea. | RSM16eFAC B | |||||||
| 178 | 21-13-13-50-1220 Wet-pipe sprinkler system components, alarm, electric pressure switch, water motor, complete with gong | Ea. | RSM16eFAC B | |||||||
| 179 | 21-13-13-50-1220-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC B | |||||||
| 180 | 21-13-13-50-1220-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC B | |||||||
| 181 | 22-05-05-10-0400-1100 Labor adjustment factors, add to labor for elevated installation, above floor level, 15' to 19.5' high (Modified using 22-01-02-20-1100) | Ea. | RSM16eFAC O&P | |||||||
| 182 | 22-05-05-10-0400-4140 Labor adjustment factors, add to labor for working in existing occupied buildings, office building (Modified using 22-01-02-20-4140) | Ea. | RSM16eFAC O&P | |||||||
| 183 | 22-05-05-10-0410-1100 Labor adjustment factors, add to labor for elevated installation, above floor level, 15' to 19.5' high (Modified using 22-01-02-20-1100) | Ea. | RSM16eFAC O&P | |||||||
| 184 | 22-05-05-10-0420-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC O&P | |||||||
| 185 | 22-05-05-10-0500-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC O&P | |||||||
| 186 | 22-05-05-10-0710 Plumbing demolition, carriers and supports, fountains, sinks, lavatories and urinals | Ea. | RSM16eFAC O&P | |||||||
| 187 | 22-05-05-10-0732 Plumbing demolition, grinder pump or sewage ejector system, simplex | Ea. | RSM16eFAC O&P | |||||||
| 188 | 22-05-05-10-1100-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC O&P | |||||||
| 189 | 22-05-05-10-1120 Plumbing demolition, fixtures, including 10' piping, bath tubs, fiberglass | Ea. | RSM16eFAC O&P | |||||||
| 190 | 22-05-05-10-1140-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC O&P | |||||||
| 191 | 22-05-05-10-1150-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC O&P | |||||||
| 192 | 22-05-05-10-1200 Plumbing demolition, fixtures, including 10' piping, lavatory, wall hung | Ea. | RSM16eFAC O&P | |||||||
| 193 | 22-05-05-10-1200-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC O&P | |||||||
| 194 | 22-05-05-10-1220-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC O&P | |||||||
| 195 | 22-05-05-10-1320 Plumbing demolition, fixtures, including 10' piping, sink, double compartment | Ea. | RSM16eFAC O&P | |||||||
| 196 | 22-05-05-10-1340-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC O&P | |||||||
| 197 | 22-05-05-10-1400 Plumbing demolition, fixtures, including 10' piping, water closet, floor mounted | Ea. | RSM16eFAC O&P | |||||||
| 198 | 22-05-05-10-1400-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC O&P | |||||||
| 199 | 22-05-05-10-1440 Plumbing demolition, fixtures, including 10' piping, wash fountain, 36" diameter | Ea. | RSM16eFAC O&P | |||||||
| 200 | 22-05-05-10-1440-5180 Labor adjustment factors, add to labor, miscellaneous, excessive heat or cold (Modified using 22-01-02-20-5180) | Ea. | RSM16eFAC O&P | |||||||
| 201 | 22-05-05-10-1442 Plumbing demolition, fixtures, including 10' piping, wash fountain, 54" diameter | Ea. | RSM16eFAC O&P | |||||||
| 202 | 22-05-05-10-1500-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC O&P | |||||||
| 203 | 22-05-05-10-1900 Plumbing demolition, piping fittings, single connection, up thru 1-1/2" diameter | Ea. | RSM16eFAC O&P | |||||||
| 204 | 22-05-05-10-1980-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC O&P | |||||||
| 205 | 22-05-05-10-2000-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | L.F. | RSM16eFAC O&P | |||||||
| 206 | 22-05-05-10-2000-4220 Labor adjustment factors, add to labor for working in existing occupied buildings, factory or warehouse (Modified using 22-01-02-20-4220) | L.F. | RSM16eFAC B | |||||||
| 207 | 22-05-05-10-2000-4220 Labor adjustment factors, add to labor for working in existing occupied buildings, factory or warehouse (Modified using 22-01-02-20-4220) | L.F. | RSM16eFAC B | |||||||
| 208 | 22-05-05-10-2000-4220 Labor adjustment factors, add to labor for working in existing occupied buildings, factory or warehouse (Modified using 22-01-02-20-4220) | L.F. | RSM16eFAC B | |||||||
| 209 | 22-05-05-10-2000-4220 Labor adjustment factors, add to labor for working in existing occupied buildings, factory or warehouse (Modified using 22-01-02-20-4220) | L.F. | RSM16eFAC B | |||||||
| 210 | 22-05-05-10-2050 R&R - Plumbing demolition, piping, metal, 2" thru 3-1/2" diameter | L.F. | CUSTOM O&P | |||||||
| 211 | 22-05-05-10-2050 Plumbing demolition, piping, metal, 2" thru 3-1/2" diameter | L.F. | RSM16eFAC O&P | |||||||
| 212 | 22-05-05-10-2050 R&R - Plumbing demolition, piping, metal, 2" thru 3-1/2" diameter | L.F. | CUSTOM O&P | |||||||
| 213 | 22-05-05-10-2050 Plumbing demolition, piping, metal, 2" thru 3-1/2" diameter | L.F. | RSM16eFAC B | |||||||
| 214 | 22-05-05-10-2160-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | L.F. | RSM16eFAC O&P | |||||||
| 215 | 22-05-05-10-2180-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC O&P | |||||||
| 216 | 22-05-05-10-2200-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC O&P | |||||||
| 217 | 22-05-05-10-2230-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | L.F. | RSM16eFAC O&P | |||||||
| 218 | 22-05-05-10-3110-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC O&P | |||||||
| 219 | 22-05-05-10-6000-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC O&P | |||||||
| 220 | 22-05-05-10-9000 R&R - Plumbing demolition, minimum labor/equipment charge | Job | CUSTOM O&P | |||||||
| 221 | 22-05-05-10-9000 Plumbing demolition, minimum labor/equipment charge | Job | RSM16eFAC O&P | |||||||
| 222 | 22-05-05-10-9100-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC O&P | |||||||
| 223 | 22-05-05-10-9200 Plumbing demolition, valve, plastic, up thru 1-1/2" diameter | Ea. | RSM16eFAC O&P | |||||||
| 224 | 22-05-05-10-9300 Plumbing demolition, vent flashing and caps | Ea. | RSM16eFAC O&P | |||||||
| 225 | 22-05-05-10-9410 Plumbing demolition, water heaters, up thru 245 GPH | Ea. | RSM16eFAC O&P | |||||||
| 226 | 22-05-23-10-0510-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | Ea. | RSM16eFAC O&P | |||||||
| 227 | 22-05-23-20-1910 Valves, bronze, check, swing, class 150, regrinding disc, threaded, 2-1/2" | Ea. | RSM16eFAC B | |||||||
| 228 | 22-05-23-20-1910 Valves, bronze, check, swing, class 150, regrinding disc, threaded, 2-1/2" | Ea. | RSM16eFAC B | |||||||
| 229 | 22-11-13-23-1100 R&R - Pipe/tube, copper, solder joints, type K tubing, couplings and clevis hanger assemblies, 10' O.C., 1/4" diameter | L.F. | CUSTOM O&P | |||||||
| 230 | 22-11-13-23-1100 Pipe/tube, copper, solder joints, type K tubing, couplings and clevis hanger assemblies, 10' O.C., 1/4" diameter | L.F. | RSM16eFAC B | |||||||
| 231 | 22-11-13-23-1100 Pipe/tube, copper, solder joints, type K tubing, couplings and clevis hanger assemblies, 10' O.C., 1/4" diameter | L.F. | RSM16eFAC B | |||||||
| 232 | 22-11-13-23-1100 R&R - Pipe/tube, copper, solder joints, type K tubing, couplings and clevis hanger assemblies, 10' O.C., 1/4" diameter | L.F. | CUSTOM O&P | |||||||
| 233 | 22-11-13-23-1100-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | L.F. | RSM16eFAC B | |||||||
| 234 | 22-11-13-23-1100-1080 Labor adjustment factors, add to labor for elevated installation, above floor level, 10' to 14.5' high (Modified using 22-01-02-20-1080) | L.F. | RSM16eFAC B | |||||||
| 235 | 22-11-13-45-5750 Pipe fittings, steel, threaded, malleable iron, 150 lbs., black, coupling, 2-1/2" | Ea. | RSM16eFAC B | |||||||
| 236 | 22-11-13-45-5750 Pipe fittings, steel, threaded, malleable iron, 150 lbs., black, coupling, 2-1/2" | Ea. | RSM16eFAC B | |||||||
| 237 | 22-11-13-45-5750 Pipe fittings, steel, threaded, malleable iron, 150 lbs., black, coupling, 2-1/2" | Ea. | RSM16eFAC B | |||||||
| 238 | 22-11-13-45-5750 Pipe fittings, steel, threaded, malleable iron, 150 lbs., black, coupling, 2-1/2" | Ea. | RSM16eFAC B | |||||||
| 239 | 22-11-13-48-4740 Pipe, fittings and valves, steel, grooved-joint, fittings, excluding coupling material required at joints, add 1 selected coupling, material only, per joint for installed price, tee, | Ea. | RSM16eFAC B | |||||||
| 240 | 22-11-13-48-4740 Pipe, fittings and valves, steel, grooved-joint, fittings, excluding coupling material required at joints, add 1 selected coupling, material only, per joint for installed price, tee, | Ea. | RSM16eFAC B | |||||||
| 241 | 22-11-13-48-4750 Pipe, fittings and valves, steel, grooved-joint, fittings, excluding coupling material required at joints, add 1 selected coupling, material only, per joint for installed price, tee, | Ea. | RSM16eFAC B | |||||||
| 242 | 22-11-13-48-4750 Pipe, fittings and valves, steel, grooved-joint, fittings, excluding coupling material required at joints, add 1 selected coupling, material only, per joint for installed price, tee, | Ea. | RSM16eFAC B | |||||||
| 243 | 22-11-13-48-4770 Pipe, fittings and valves, steel, grooved-joint, fittings, excluding coupling material required at joints, add 1 selected coupling, material only, per joint for installed price, tee, | Ea. | RSM16eFAC B | |||||||
| 244 | 22-11-13-48-4770 Pipe, fittings and valves, steel, grooved-joint, fittings, excluding coupling material required at joints, add 1 selected coupling, material only, per joint for installed price, tee, | Ea. | RSM16eFAC B | |||||||
| 245 | 22-11-13-48-4780 Pipe, fittings and valves, steel, grooved-joint, fittings, excluding coupling material required at joints, add 1 selected coupling, material only, per joint for installed price, tee, | Ea. | RSM16eFAC B | |||||||
| 246 | 22-11-13-48-4780 Pipe, fittings and valves, steel, grooved-joint, fittings, excluding coupling material required at joints, add 1 selected coupling, material only, per joint for installed price, tee, | Ea. | RSM16eFAC B | |||||||
| 247 | 22-11-13-48-4800 Pipe, fittings and valves, steel, grooved-joint, fittings, excluding coupling material required at joints, add 1 selected coupling, material only, per joint for installed price, tee, | Ea. | RSM16eFAC B | |||||||
| 248 | 22-11-13-48-4800 Pipe, fittings and valves, steel, grooved-joint, fittings, excluding coupling material required at joints, add 1 selected coupling, material only, per joint for installed price, tee, | Ea. | RSM16eFAC B | |||||||
| 249 | 22-13-19-13-2040 Sanitary drains, floor, medium duty, cast iron, deep flange, 7" diameter top, 2" and 3" pipe size | Ea. | RSM16eMCOM B | |||||||
| 250 | 22-13-19-14-2000-0700 Floor receptors, for acid-resisting bucket, add (Modified using 22-13-19-14-0700) | Ea. | CUSTOM | |||||||
| 251 | 22-13-19-14-3000 Floor receptors, for connection to 2", 3" and 4" diameter pipe, 8" x 4" rectangular top, 7.5 square inch open area | Ea. | CUSTOM | |||||||
| 252 | 22-13-19-15-0200 Sink waste treatment, system for commercial kitchens, includes clock timer, and fittings, excluding chemical, wall mounted cabinet | Ea. | CUSTOM | |||||||
| 253 | 23-05-05-10-0360 HVAC demolition, boilers, gas or oil, 2100 thru 4500 MBH | Ea. | RSM16eFAC B | |||||||
| 254 | 23-05-05-10-0360 HVAC demolition, boilers, gas or oil, 2100 thru 4500 MBH | Ea. | RSM16eFAC B | |||||||
| 255 | 23-05-05-10-5120 HVAC demolition, roof top air conditioner, 50 thru 140 ton | Ea. | RSM16eFAC B | |||||||
| 256 | 23-05-05-10-6600 HVAC demolition, thru-the-wall air conditioner | Ea. | RSM16eFAC B | |||||||
| 257 | 23-05-05-10-7000 HVAC demolition, vent chimney, prefabricated, up thru 12" diameter | V.L.F. | RSM16eFAC B | |||||||
| 258 | 23-05-05-10-7000 HVAC demolition, vent chimney, prefabricated, up thru 12" diameter | V.L.F. | RSM16eFAC B | |||||||
| 259 | 23-05-05-10-8010 HVAC demolition, water chiller, 15 thru 100 ton | Ea. | RSM16eFAC B | |||||||
| 260 | 23-34-14-10-7830 Blower type HVAC fans, utility set, steel construction, pedestal, 1/4" static pressure, v-belt drive, drive cover, 3 phase, 7,500 CFM, 2 HP | Ea. | RSM16eFAC B | |||||||
| 261 | 23-34-14-10-7830-1200 Labor adjustment factors, add to labor for elevated installation, above floor level, 40' and higher (Modified using 22-01-02-20-1200) | Ea. | RSM16eFAC B | |||||||
| 262 | 23-36-16-10-5500 Variable volume mixing boxes, mixing box, includes electric or pneumatic motor, recommend use with attenuator, VAV cool only, pneumatic, pressure independent, 300 to 600 CFM | Ea. | RSM16eFAC B | |||||||
| 263 | 23-36-16-10-5500 Variable volume mixing boxes, mixing box, includes electric or pneumatic motor, recommend use with attenuator, VAV cool only, pneumatic, pressure independent, 300 to 600 CFM | Ea. | RSM16eFAC B | |||||||
| 264 | 23-36-16-10-5500-1100 Labor adjustment factors, add to labor for elevated installation, above floor level, 15' to 19.5' high (Modified using 22-01-02-20-1100) | Ea. | RSM16eFAC B | |||||||
| 265 | 23-36-16-10-5500-1100 Labor adjustment factors, add to labor for elevated installation, above floor level, 15' to 19.5' high (Modified using 22-01-02-20-1100) | Ea. | RSM16eFAC B | |||||||
| 266 | 23-36-16-10-5500-1100 Labor adjustment factors, add to labor for elevated installation, above floor level, 15' to 19.5' high (Modified using 22-01-02-20-1100) | Ea. | RSM16eFAC B | |||||||
| 267 | 23-36-16-10-5510 Variable volume mixing boxes, mixing box, includes electric or pneumatic motor, recommend use with attenuator, VAV cool only, pneumatic, pressure independent, 500 to 1000 CFM | Ea. | RSM16eFAC B | |||||||
| 268 | 23-36-16-10-5510 Variable volume mixing boxes, mixing box, includes electric or pneumatic motor, recommend use with attenuator, VAV cool only, pneumatic, pressure independent, 500 to 1000 CFM | Ea. | RSM16eFAC B | |||||||
| 269 | 23-36-16-10-5510-1100 Labor adjustment factors, add to labor for elevated installation, above floor level, 15' to 19.5' high (Modified using 22-01-02-20-1100) | Ea. | RSM16eFAC B | |||||||
| 270 | 23-36-16-10-5510-1100 Labor adjustment factors, add to labor for elevated installation, above floor level, 15' to 19.5' high (Modified using 22-01-02-20-1100) | Ea. | RSM16eFAC B | |||||||
| 271 | 23-36-16-10-5630 Variable volume mixing boxes, mixing box, includes electric or pneumatic motor, recommend use with attenuator, VAV hot water coils, damper, actuator and thermostat, 600 CFM | Ea. | RSM16eFAC B | |||||||
| 272 | 23-36-16-10-5630 Variable volume mixing boxes, mixing box, includes electric or pneumatic motor, recommend use with attenuator, VAV hot water coils, damper, actuator and thermostat, 600 CFM | Ea. | RSM16eFAC B | |||||||
| 273 | 23-36-16-10-5630-1100 Labor adjustment factors, add to labor for elevated installation, above floor level, 15' to 19.5' high (Modified using 22-01-02-20-1100) | Ea. | RSM16eFAC B | |||||||
| 274 | 23-36-16-10-5630-1100 Labor adjustment factors, add to labor for elevated installation, above floor level, 15' to 19.5' high (Modified using 22-01-02-20-1100) | Ea. | RSM16eFAC B | |||||||
| 275 | 23-37-13-60-4430-4260 Labor adjustment factors, add to labor for working in existing occupied buildings, multi dwelling (Modified using 22-01-02-20-4260) | Ea. | CUSTOM | |||||||
| 276 | 23-37-13-60-4430-4260 Labor adjustment factors, add to labor for working in existing occupied buildings, multi dwelling (Modified using 22-01-02-20-4260) | Ea. | CUSTOM | |||||||
| 277 | 23-37-13-60-4430-4260 Labor adjustment factors, add to labor for working in existing occupied buildings, multi dwelling (Modified using 22-01-02-20-4260) | Ea. | CUSTOM | |||||||
| 278 | 23-52-13-10-1080 Electric boilers, ASME, including standard controls and trim, steam, 24 KW, 81.8 MBH | Ea. | RSM16eFAC B | |||||||
| 279 | 23-52-13-10-1160 Electric boilers, ASME, including standard controls and trim, steam, 60 KW, 205 MBH | Ea. | RSM16eFAC B | |||||||
| 280 | 23-52-23-20-2000 Gas-fired boilers, natural or propane, including standard controls, packaged, cast iron, with insulated jacket, steam, gross output, 81 MBH | Ea. | RSM16eFAC B | |||||||
| 281 | 23-52-23-20-2000 Gas-fired boilers, natural or propane, including standard controls, packaged, cast iron, with insulated jacket, steam, gross output, 81 MBH | Ea. | RSM16eFAC B | |||||||
| 282 | 26-01-40-51-3000 Electrical systems repair and replacement, including remove, store and reinstall, remove and replace, switch cover | Ea. | RSM16eFAC O&P | |||||||
| 283 | 26-01-40-51-3020 Electrical systems repair and replacement, including remove, store and reinstall, remove and replace, outlet cover | Ea. | RSM16eFAC O&P | |||||||
| 284 | 26-05-05-10-0462 Electrical demolition, wiremold raceway, plugmold with receptacle | L.F. | RSM16eFAC O&P | |||||||
| 285 | 26-05-05-10-0465 Electrical demolition, wiremold raceway, telephone or power pole | Ea. | RSM16eFAC O&P | |||||||
| 286 | 26-05-05-10-0520 Electrical demolition, channels, steel, including fittings and hangers, 3/4" x 1-1/2" | L.F. | RSM16eFAC O&P | |||||||
| 287 | 26-05-05-10-0660 Electrical demolition, copper bus duct, indoor, 3 phase, including hangers and supports, 600 amp | L.F. | RSM16eFAC O&P | |||||||
| 288 | 26-05-05-10-0820 Electrical demolition, plug-in switches, 600 volt 3 phase, including disconnecting, wire and conduit terminations, 30 amp | Ea. | RSM16eFAC O&P | |||||||
| 289 | 26-05-05-10-1100 Electrical demolition, safety switches, 250 or 600 volt, including disconnection of wire and conduit terminations, 30 amp | Ea. | RSM16eFAC O&P | |||||||
| 290 | 26-05-05-10-1202 Electrical demolition, safety switches, 250 or 600 volt, including disconnection of wire and conduit terminations, explosion proof, 60 amp | Ea. | RSM16eFAC O&P | |||||||
| 291 | 26-05-05-10-1230 Electrical demolition, panel boards, including removal of all breakers, conduit terminations and wire connections, 3 wire, 120/240 volt, 100 amps, to 20 circuits | Ea. | RSM16eFAC O&P | |||||||
| 292 | 26-05-05-10-1230-9910 Electrical demolition, add to labor for higher elevated installation, 15' to 20' high, add (Modified using 26-05-05-10-9910) | Ea. | RSM16eFAC O&P | |||||||
| 293 | 26-05-05-10-1640 Electrical demolition, pull boxes and cabinets, sheet metal, including removal of supports and conduit terminations, 6" x 6" x 4" | Ea. | RSM16eFAC O&P | |||||||
| 294 | 26-05-05-10-1660 Electrical demolition, pull boxes and cabinets, sheet metal, including removal of supports and conduit terminations, 12" x 12" x 4" | Ea. | RSM16eFAC O&P | |||||||
| 295 | 26-05-05-10-1830 Electrical demolition, wire, THW-THWN-THHN, removed from in place conduit, to 15' high, #14 | C.L.F. | RSM16eFAC O&P | |||||||
| 296 | 26-05-05-10-2120 Electrical demolition, interior fluorescent fixtures, including supports and whips, to 15' high, recessed drop-in, 2' x 4', 2 lamp | Ea. | RSM16eFAC O&P | |||||||
| 297 | 26-05-05-10-2420 Electrical demolition, interior fluorescent fixtures, including supports and whips, to 15' high, pendant mount, industrial, including removal of chain or rod hangers, to 15' high, 4' | Ea. | RSM16eFAC O&P | |||||||
| 298 | 26-05-05-10-2620 Electrical demolition, exterior fixtures, incandescent, wall mount, 100 watt | Ea. | RSM16eFAC O&P | |||||||
| 299 | 26-05-05-15-0140 Electrical demolition, grounding, water pipe ground clamp, bronze, heavy duty | Ea. | RSM16eFAC O&P | |||||||
| 300 | 26-05-05-20-3020 Electrical demolition, wiring methods, modular flexible wiring, conversion module | Ea. | RSM16eFAC O&P | |||||||
| 301 | 26-05-05-20-3300 Electrical demolition, wiring methods, data system, cable with connection | Ea. | RSM16eFAC O&P | |||||||
| 302 | 26-05-05-20-4030 Electrical demolition, wiring methods, cable tray, including fitting and support, galvanized steel, 12" wide | L.F. | RSM16eFAC O&P | |||||||
| 303 | 26-05-05-25-0120 Electrical demolition, electrical power, meter socket, 4 terminal | Ea. | RSM16eFAC O&P | |||||||
| 304 | 26-05-05-25-0310 Electrical demolition, electrical power, base meter devices, 4 meter | Ea. | RSM16eFAC O&P | |||||||
| 305 | 26-05-05-25-3030 Electrical demolition, electrical power, uninterruptible power supply system (UPS), 1 phase, 120 volt, 5 kVA | Ea. | RSM16eFAC O&P | |||||||
| 306 | 26-05-10-C Relocated electrical panel | Ea. | CUSTOM B | |||||||
| 307 | 26-05-19-35-0020 Cable terminations, wire connectors, screw type, #18 to #12 | Ea. | RSM16eFAC B | |||||||
| 308 | 26-05-19-90-0940 Wire, 600 volt, copper type THWN-THHN, solid, #12 | C.L.F. | RSM16eFAC B | |||||||
| 309 | 26-05-19-90-0940 Wire, 600 volt, copper type THWN-THHN, solid, #12 | C.L.F. | RSM16eFAC B | |||||||
| 310 | 26-05-19-90-0940 Wire, 600 volt, copper type THWN-THHN, solid, #12 | C.L.F. | RSM16eFAC B | |||||||
| 311 | 26-05-33-13-0700 Conduit, to 15' high, includes 2 terminations, 2 elbows, 11 beam clamps, and 11 couplings per 100 L.F., aluminum, 1" diameter | L.F. | RSM16eFAC B | |||||||
| 312 | 26-05-33-13-5020-9910 Conduit, to 15' high, add to labor for higher elevated installation, 15' to 20' high, add (Modified using 26-05-33-13-9910) | L.F. | RSM16eFAC B | |||||||
| 313 | 26-05-33-13-5020-9910 Conduit, to 15' high, add to labor for higher elevated installation, 15' to 20' high, add (Modified using 26-05-33-13-9910) | L.F. | RSM16eFAC B | |||||||
| 314 | 26-05-33-14-0200 Conduit to 15' high, includes 11 couplings per 100', electric metallic tubing, 1/2" diameter | L.F. | RSM16eFAC B | |||||||
| 315 | 26-05-33-15-5040 Conduit nipples, including locknuts and bushings, rigid galvanized steel plastic coated, 40 mil thick, 1" diameter, 2-1/2" long | Ea. | RSM16eFAC B | |||||||
| 316 | 26-05-33-15-5040 Conduit nipples, including locknuts and bushings, rigid galvanized steel plastic coated, 40 mil thick, 1" diameter, 2-1/2" long | Ea. | RSM16eFAC B | |||||||
| 317 | 26-05-33-16-0400 Outlet boxes, pressed steel, square, 4-11/16", 2-1/8" deep, extension rings | Ea. | RSM16eFAC B | |||||||
| 318 | 26-05-33-16-0400 Outlet boxes, pressed steel, square, 4-11/16", 2-1/8" deep, extension rings | Ea. | RSM16eFAC B | |||||||
| 319 | 26-05-90-10-4100 Residential wiring, receptacle devices, including box and cover plate, 20' average runs, duplex outlet, 20 amp receptacle, #12/2, type NM (Romex) cable | Ea. | RSM16eFAC B | |||||||
| 320 | 26-13-16-10-1000 Switchgear, pothead, one 3 conductor or three 1 conductor | Ea. | RSM16eMCOM B | |||||||
| 321 | 26-13-16-10-1000 Switchgear, pothead, one 3 conductor or three 1 conductor | Ea. | RSM16eMCOM B | |||||||
| 322 | 26-13-16-10-1500 Switchgear, pothead, lightning arresters, intermediate class or line type, 13.8 kV | Ea. | RSM16eMCOM B | |||||||
| 323 | 26-13-16-10-1500 Switchgear, pothead, lightning arresters, intermediate class or line type, 13.8 kV | Ea. | RSM16eMCOM B | |||||||
| 324 | 26-27-26-20-2470 Wiring devices elements, receptacle, duplex, 120 volt, grounded, 20 amp | Ea. | RSM16eFAC B | |||||||
| 325 | 26-28-16-20-9010 Safety switches, disconnect switch, 600 volt, 3 pole, fusible, 30 amp, to 10 HP motor | Ea. | RSM16eFAC B | |||||||
| 326 | 26-28-1C 50 feet length 400Hz High Performance Single Jacket SMART Cable Assemblies | Ea. | CUSTOM B | |||||||
| 327 | 26-28-2C 400 Hz Load Point Control Unit | Ea. | CUSTOM B | |||||||
| 328 | 26-28-3C 20 KVA-400 Hz Power Inverter | Ea. | CUSTOM B | |||||||
| 329 | 26-28-4C T1 Power connection | Ea. | CUSTOM B | |||||||
| 330 | 26-28-5C T6 Power connection | Ea. | CUSTOM B | |||||||
| 331 | 26-51-13-55-4000 Interior LED fixtures, including lamps, mounting hardware, and connections, high bay, surface mounted, round, 150 watts | Ea. | RSM16eFAC Grn, B | |||||||
| 332 | 26-52-13-10-0700 Emergency lighting and battery units, twin sealed beam light, 25 watt, 6 volt each, nickel cadmium battery operated | Ea. | RSM16eFAC B | |||||||
| 333 | 26-52-13-10-0700 Emergency lighting and battery units, twin sealed beam light, 25 watt, 6 volt each, nickel cadmium battery operated | Ea. | RSM16eFAC B | |||||||
| 334 | 26-53-13-10-0240 Exit lighting fixtures, exit light ceiling or wall mount, LED with battery unit, single face | Ea. | RSM16eFAC Grn, B | |||||||
| 335 | 26-53-13-10-0240 Exit lighting fixtures, exit light ceiling or wall mount, LED with battery unit, single face | Ea. | RSM16eFAC Grn, B | |||||||
| 336 | 26-55-61-10-4000 Lights, lights, strobe light, 1 to 15 flashes per second, quartz | Ea. | RSM16eFAC B | |||||||
| 337 | 28-05-13-23-1650 Fire alarm communications conductors and cables, fire alarm FEP teflon 150 volt to 200°C, #22, 4 pair | C.L.F. | RSM16eFAC B | |||||||
| 338 | 28-31-23-50-4000 Alarm panels and devices, excluding wires and conduit, fire, alarm control panel, 12 zone | Ea. | RSM16eFAC B | |||||||
| 339 | 28-31-23-50-4170 Alarm panels and devices, excluding wires and conduit, fire, alarm control panel, addressable, with voice, up to 400 points | Ea. | RSM16eFAC B | |||||||
| 340 | 28-31-23-50-5610 Alarm panels and devices, excluding wires and conduit, fire, strobe and horn (ADA type) | Ea. | RSM16eFAC B | |||||||
| 341 | 28-31-23-50-5610 Alarm panels and devices, excluding wires and conduit, fire, strobe and horn (ADA type) | Ea. | RSM16eFAC B | |||||||
| 342 | 28-31-46-50-5240 Smoke detectors, excluding wires and conduit, smoke detector, ceiling type, addressable type | Ea. | RSM16eFAC B | |||||||
| 343 | 32-01-01c Waterproofing with Geotechnical Polymer | Each | CUSTOM B | |||||||
| 344 | Suspended Acoustical Ceiling Tiles R&R - Install new Suspended Acoustical Ceiling Tiles | SF | CUSTOM B |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.