Quonset Point Fuels Storage Complex Replacement Construction at the Rhode Island Air National Guard Station in North Kingstown, Rhode Island
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- W912WJ20R0011
- Agency
-
ENDIST New England
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- North Kingstown RI 02852 USA
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Army Corps of Engineers, New England District is seeking to replace the fuels storage complex at the Quonset Point Rhode Island Air National Guard Station in North Kingstown, Rhode Island. The work includes replacing truck offload and fillstand positions and associated pumping and filtration equipment, constructing a new 600 gallon per minute pumphouse with control room, upgrading the refueler parking area, and reusing existing storage tanks. The requirement will be evaluated using Best Value Tradeoff procedures, with proposals due by October 22, 2020.
This requirement is set aside for small businesses only, with a NAICS code of 236220 for construction of fueling facilities. The estimated value is between $5-10 million. Work will be performed at the Quonset Point Rhode Island Air National Guard Station in North Kingstown, Rhode Island. Construction will be conducted in phases to allow continued operation of the existing fuel storage complex until the new 600 gallon per minute pumphouse and associated equipment are completed.
Notice text
The New England District, U.S. Army Corps of Engineers (District) will be issuing a solicitation for the construction of the Fuels Storage Complex Replacement at the Quonset Point Rhode Island Air National Guard Station in North Kingstown, Rhode Island.
The work required shall consist of the following:
- Replace the truck offload and fillstand positions and associated pumping / filtration equipment in compliance with UFC 3-460-01 Design: Petroleum Fuel Facilities and the DoD Type III Hydrant System Standards, as applicable
- Construction of a new 600 gallon per minute (GPM) capacity pumphouse with control room, offload skids, fuel pumps, filter / separator vessels, truck fillstand equipment, associated valves, piping and electrical equipment
- Upgrades to the existing refueler parking area
- Existing storage tanks will be reused with the new system
- Construction will be phased to allow the existing system to operate until most of the new system is completed
The NAICS code for the work described herein is 236220. The estimated magnitude of the work is expected to be between $5,000,000 and $10,000,000. This requirement will be solicited as a small business set-aside procurement using the Best Value Tradeoff acquisition procedures.
Files
Show 40 more
50 files listed here. See the rest on GovTribe.
Notice history
| Notice | Type | Posted |
|---|---|---|
| Quonset Point Fuels Storage Complex Replacement Construction at the Rhode Island Air National Guard Station in North Kingstown, Rhode Island | Award Notice | |
| This notice | Solicitation | |
| Quonset Point Fuels Storage Complex Replacement Construction at the Rhode Island Air National Guard Station in North Kingstown, Rhode Island | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Construction Services for Confined Aquatic Disposal Cell Construction and Maintenance Dredging of the Providence River Federal Navigation Project, Providence, Rhode Island. | ENDIST New England | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity