Amendment 0009 - ES508 STORAGE TANK ELECTRICAL ELEVATION.pdf
PDF 509 KB Posted
- Solicitation number
- W912WJ20R0011
About this file
This document provides details for a federal contract solicitation for construction services. The U.S. Army Corps of Engineers, New England District will issue a solicitation to replace the truck offload, fillstand positions, and associated fuel pumping and filtration equipment at the Quonset Point Rhode Island Air National Guard Station. The work will include constructing a new 600 gallon per minute pumphouse with control room, offload skids, fuel pumps, filter/separator vessels, truck fillstand equipment, associated valves, piping and electrical work. The project will also upgrade the existing refueler parking area and reuse the existing storage tanks with the new system. The construction will be conducted in phases to allow the current system to operate until most of the new one is completed. The solicitation will be set aside for small businesses as a best value tradeoff procurement between $5-10 million. The NAICS code is 236220.
View the file
Other files
Show 40 more
Latest 50 of 51 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F I L E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D
2 3
C
4 5
A
B
D A
T E
F I L
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L O
T
S
C A
L E
P
L O
T
D
A T
E
S M
B L
D E
S C
R I P
T I O
N
C O
N T
R A
C T
O
SHEET
IDENTIFICATION
D A
T E
A P
P R
US Army Corps of Engineers
U S
A
R M
Y
C
O R
P S
O
E
N G
I N
E E
R S
O M
A H
A
D
I S
T R
I C
T
O M
A H
A
N
E B
R A
S K
A
--S E
P T
E M
B E
R
A N
S I
D
OMAHA DISTRICT
S E
A L
D E
S C
S
R
E P
L A
C
U E
L
F
A C
I L
I T
I E
S
Q U
O N
S E
T
A
R
T
I O
N A
L
G
U A
R D
B
S
E
N O
R T
H
K
I N
G S
T O
W N
R
H O
D
L A
N D
R
READY TO ADVERTISE (RTA)
PROFESSIONAL
G EO R G I A
D O
UG L A S P . E NG
E
L
ENG I NE ER
REGI STERED
No. 41840
ES508
S T
O R
A G
E
T
A N
K
E
L E
C T
R I C
A L
E L
E V
A T
I O
N
D
E
N G
L E
E
J A
C K
S O
N M
F
U R
R
C
L A
Y S
O N
E
S D
W G
HHLA
J
J
J
J
HLA
LLA
LS
GENERAL NOTES:
THIS ELEVATION IS INCLUDED TO SHOW GENERAL DETAILS OF EXISTING EQUIPMENT
ON THE STORAGE TANKS THAT ARE REQUIRED TO BE REWIRED TO THE NEW
PUMPHOUSE.
1. FIELD VERIFY EXACT LOCATION OF LEVEL SWITCHES AND OTHER EQUIPMENT.
2. SEE E-002 FOR HAZARDOUS AREA LOCATIONS PLAN, COORDINATE HAZARDOUS
LOCATIONS WITH NEC 500
3. DETAIL APPLIES TO BOTH EXISTING ABOVE GROUND BULK FUEL TANKS,
LS
LLLA
J
J
TO PCP / LEVEL ALARMS
16 #12, 1 #12 GND, 1-1/2"C
TO PCP / LIMIT SWITCHES
12 #12, 1 #12 GND, 1"C
TANK ATG 1-2 (EACH)
TWO (2) 2/C#12 SHIELDED TWISTED
PAIR CABLE, 1"C TO ATG BACKBOARD.
2 #10, #12 GND, 1"C TO PP-48(50)
STORAGE TANK ELECTRICAL ELEVATION (TYPICAL OF 2)
SCALE: NTS
OUTLET LIMIT SWITCHES
SEAL-OFFS. AS REQUIRED,
TYPICAL
TYPICAL LEVEL SWITCH EXISTING GROUND
CONNECTIONS TO REMAIN
UNCHANGED
EXISTING GROUND TO REMAIN
TYPICAL LEVEL SWITCH
CONTINUE TO STILLWELL FOR ATG SYSTEM.
TO PP2
WATER DRAW
OFF PUMP
A
M E
N D
M E
T
D
P E
P
KEYED NOTE:
1. OUTLET LIMIT SWITCHES WILL BE DISCONNECTED AND NOT REUSED. REMOVE
CONDUCTORS FROM CONDUIT AND TERMINATE CONDUIT WITH THREADED CAP OR
PLUG AND PROVIDE ENGRAVED TAG AT BOTH ENDS IDENTIFYING THE CONDUIT AS
SPARE.