About this file

This document provides details for a federal construction contract opportunity for replacement of the fuels storage complex at the Quonset Point Rhode Island Air National Guard Station in North Kingstown, Rhode Island. The U.S. Army Corps of Engineers, New England District will issue a solicitation for construction work including replacing truck offload and fillstand positions and associated pumping, filtration, and fuel handling equipment. The new construction will include a 600 GPM capacity pumphouse with control room, offload skids, fuel pumps, filter/separator vessels, truck fillstand equipment, associated valves, piping and electrical work. Existing storage tanks will be reused. The work will be conducted in phases to allow continued operation of existing systems. The estimated value of construction is between $5-10 million. This will be set aside as a small business procurement using Best Value Tradeoff procedures. The NAICS code for the work is 236220.

The key information provided includes the solicitation number, project name and location, general work requirements and scope of replacement of the fuels storage complex, estimated value of construction, acquisition procedures to be used, and applicable NAICS code.

View the file

Other files

File Type Posted
Amendment 0010.pdf PDF
A-202 BUILDING SECTIONS.pdf PDF
Amendment 0009 - G-009 PHASING PLAN 1.pdf PDF
M-603 FUEL SYSTEM FLOW DIAGRAM (2 OF 2).pdf PDF
M-302 FUELING SYSTEM PIPING ELEVATIONS (2 OF 2).pdf PDF
Amendment 0009 - ES403 ENLARGED SITE PLAN (3 OF 4).pdf PDF
EP101 PUMP HOUSE POWER PLAN.pdf PDF
Amendment 0009 - ES404 ENLARGED SITE PLAN (4 OF 4).pdf PDF
A-002 CODE ANALYSIS.pdf PDF
ES101 ELECTRICAL OVERALL SITE PLAN.pdf PDF
Amendment 0009 - EP601 POWER DIAGRAMS AND SCHEDULES.pdf PDF
Amendment 0009 - Spec Section 01 22 00 - 05OCT20.pdf PDF
Amendment 0009.pdf PDF
Amendment 0009 - ES508 STORAGE TANK ELECTRICAL ELEVATION.pdf PDF
EP602 ELECTRICAL SCHEDULES.pdf PDF
Amendment 0009 - 26 24 19.00 40.pdf PDF
EP603 ELECTRICAL SCHEDULES.pdf PDF
Amendment 0009 - Schedule of Special Inspections.pdf PDF
E-001 ELECTRICAL LEGEND AND ABBREVIATIONS.pdf PDF
M-403 TRUCK FILLSTAND PIPING LAYOUT PLAN AND ELEVATION.pdf PDF
Quonset Modified document and comments.pdf PDF
ES507 PRODUCT RECOVERY TANK PLAN AND DETAIL.pdf PDF
EP604 ELECTRICAL SCHEDULES.pdf PDF
A-302 WALL SECTIONS AND DETAILS.pdf PDF
A-101 FLOOR PLAN.pdf PDF
Amendment 0008 - 03 30 00.pdf PDF
Amendment 0008 - G-013 MISCELLANEOUS WORK ITEMS AND NOTES.pdf PDF
Amendment 0008.pdf PDF
Amendment 0008 - 32 13 13.06.pdf PDF
Amendment 0008 - ES401 ENLARGED SITE PLAN (1 OF 4).pdf PDF
Amendment 0008 - 33 52 43.11.pdf PDF
Amendment 0008 - C-407 PUMPHOUSE AND PRT GRADING AND DRAINAGE PLAN - PHASE 1.pdf PDF
Amendment 0007.pdf PDF
Amendment 0006 - Wage Determination.pdf PDF
Amendment 0006 - 1802100MH-101-R1.pdf PDF
Amendment 0006 - 09 90 00 (Q - RTA - Bolded-2).pdf PDF
Amendment 0006 - 10 71 19.16 - Q - RTA - Bolded-2.pdf PDF
Amendment 0006.pdf PDF
Amendment 0006 - 33 56 19 - Q - RTA - Bolded-2.pdf PDF
Amendment 0006 - A-501 (SCHEDULES).pdf PDF
Amendment 0005.pdf PDF
Amendment 0004.pdf PDF
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
Amendment 0001.pdf PDF
Solicitation Drawing.zip ZIP file
Supplemental Price Breakdown to the Bidding Schedule.xlsx XLSX spreadsheet
Specs - Volume 1.pdf PDF
Specs - Volume 2.pdf PDF
W912WJ20R0011_Solicitation.pdf PDF
Show 40 more

Latest 50 of 51 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

METAL

SOFFIT

PANELS

45" X 20" DUCT DOWN

TO FLOOR. DUCT

TERMINATES 6" AFF -

SEE MECHANICAL

22" X 22" HVAC

PENTHOUSE

EXHAUST FAN

STEEL

FRAME

(TYP)

EXPOSED

CEILING

24" X 24" HVAC

PENTHOUSE

SUPPLY

SEE

NOTE 5

CEILING

HT - 9'-0"

STRUCTURAL

X-BRACING

BRIDGE

CRANE

BRIDGE CRANE

RUNWAY BEAM -

TYPICAL OF 2

1'-10"

1'-10"

3'-0"

4'-0"

1-HOUR RATED CEILING/

ROOF ASSEMBLY

(SEE NOTE 4)

STEEL

COLUMN

(TYP)

SEE

NOTE 5

NOTE: THE 1-HOUR

RATED CEILING/

ROOF ASSEMBLY,

(SEE NOTE 4)

CONTINUES OVER

THE ENTIRETY

ABOVE THE

CONTROL ROOM

ATTIC

DS DS

DS DS

LIGHTNING

PROTECTION AIR

TERMINAL - SEE

ELECTRICAL

R O

O F

S

L O

P E

R O

O

P E

GUTTER

WALL

OUTLINE

INTAKE LOUVER

PENTHOUSE

RIDGE CAP

EXHAUST

LOUVER

PENTHOUSE

STANDING

SEAM METAL

ROOF

DS

DS

SCALE: 1/4" = 1'-0"

4 0 4 8

F I

E

N

A M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D

2 3

C

4 5

A

B

D A

T E

F I

U M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

S M

B L

D E

S C

R I P

T I O

N

C O

N T

R A

C T

SHEET

IDENTIFICATION

D A

T E

A P

P R

US Army Corps of Engineers

U S

A

R M

Y

C

O R

P

E

N G

I N

E E

R S

O M

A H

A

D

I S

T R

I C

T

O M

A H

A

N

E B

R A

S K

A

--S E

P T

E M

B E

R

A N

S I

D

OMAHA DISTRICT

S E

A L

D E

S C

S

R

E P

L A

C

U E

L

F

A C

I L

I T

I E

S

Q U

O N

S E

T

A

I R

T

I O

N A

L

G

U A

D

B

S

E

N O

R T

H

K

I N

G S

T O

W N

R

H O

I

L A

N D

R

READY TO ADVERTISE (RTA)

A-103

R E

F L

E C

T E

D

C

E I L

I N

G

A

O

F

P L

A N

S

M

H

I C

K S

M

H

I C

K S

M

H

I C

K S

C

L A

Y S

O N

A

D

W G

REFLECTED CEILING PLAN

SCALE: 1/4" = 1'-0"

ROOF PLAN

SCALE: 1/4" = 1'-0"

RCP NOTES:

LOCATE LIGHT FIXTURES, DIFFUSERS,

SPRINKLER HEADS AND OTHER

CEILING MOUNTED

FIXTURES/ACCESSORIES IN THE

CENTER OF SQUARE CEILING TILES.

ON FIXTURES AND/OR ACCESSORIES

TO BE MOUNTED ON THE WALL OR

CEILING, CENTER THE

FIXTURE/ACCESSORY ON

ARCHITECTURAL FEATURES (I.E.

ABOVE DOORS, WALL AREA, ETC.) AS

SHOWN ON RCP.

2-HOUR-RATED, FULL-HEIGHT CMU

FIRE WALL (IBC, SECTION 706)

AS PER 706.6, EXCEPTIONS 2.1, 2.2,

AND 2.3, THE FIREWALL SHALL

TERMINATE INTO A 1-HOUR RATED

CEILING/ROOF ASSEMBLY COVERING

THE COMPLETE FRAMING BAY

BETWEEN FRAMING BENTS 1 AND 2

AND EASTWARD, OUT TO 4'-0"

MINIMUM PERPENDICULAR FROM

FACE OF FIREWALL: z e " TYPE X GYP

BD ON 6" METAL STUDS FIXED TO

UNDERSIDES OF STEEL ROOF

PURLINS.

FILL CAVITY WITH 4 PCF MINERAL

WOOL BATT INSULATION

STEEL FRAMING BENTS 1 AND 2 CLAD

WITH 1-HOUR FIRE-RESISTIVE

ASSEMBLY

1.

2.

ROOF PLAN NOTES:

COORDINATE INSTALLATION OF SMALL

DIAMETER ROOF PENETRATIONS TO

ENSURE PENETRATION IS LOCATED

BETWEEN METAL ROOF PANEL

STANDING SEAM.

1.

RCP LEGEND:

ELECTRICAL:ARCHITECTURE:

UNIT HEATER

EXTERIOR LIGHT FIXTURE

RETURN GRILLE

SUPPLY DIFFUSER

EXIT LIGHT FIXTURE

ACOUSTICAL CEILING TILE --

2'-0" X 2'-0"

LED LIGHT FIXTURE -

2'-0" X 2'-0"

LED LIGHT FIXTURE -

1'-4" X 4'-0"

LED LIGHT FIXTURE -

2'-0" X 2'-0" (EMERGENCY LIGHT)

LED LIGHT FIXTURE -

1'-4" X 4'-0" (EMERGENCY LIGHT)

RATED FIRE WALL

2-HR

3.

4.

5.

A M

E N

D M

E N

T

H M

H

1-HR

FIRE RATED WALL

S

P

RENEWAL DATE

2/28/2021

C-38283

H. MASON

HICKS, AIA

Sheets and Views
A-103 REFLECTED CEILING AND ROOF PLANS

File details come from the government source that posted it. Updated .