A-103 REFLECTED CEILING AND ROOF PLANS.pdf
PDF 211 KB Posted
- Solicitation number
- W912WJ20R0011
About this file
This document provides details for a federal construction contract opportunity for replacement of the fuels storage complex at the Quonset Point Rhode Island Air National Guard Station in North Kingstown, Rhode Island. The U.S. Army Corps of Engineers, New England District will issue a solicitation for construction work including replacing truck offload and fillstand positions and associated pumping, filtration, and fuel handling equipment. The new construction will include a 600 GPM capacity pumphouse with control room, offload skids, fuel pumps, filter/separator vessels, truck fillstand equipment, associated valves, piping and electrical work. Existing storage tanks will be reused. The work will be conducted in phases to allow continued operation of existing systems. The estimated value of construction is between $5-10 million. This will be set aside as a small business procurement using Best Value Tradeoff procedures. The NAICS code for the work is 236220.
The key information provided includes the solicitation number, project name and location, general work requirements and scope of replacement of the fuels storage complex, estimated value of construction, acquisition procedures to be used, and applicable NAICS code.
View the file
Other files
Show 40 more
Latest 50 of 51 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
METAL
SOFFIT
PANELS
45" X 20" DUCT DOWN
TO FLOOR. DUCT
TERMINATES 6" AFF -
SEE MECHANICAL
22" X 22" HVAC
PENTHOUSE
EXHAUST FAN
STEEL
FRAME
(TYP)
EXPOSED
CEILING
24" X 24" HVAC
PENTHOUSE
SUPPLY
SEE
NOTE 5
CEILING
HT - 9'-0"
STRUCTURAL
X-BRACING
BRIDGE
CRANE
BRIDGE CRANE
RUNWAY BEAM -
TYPICAL OF 2
1'-10"
1'-10"
3'-0"
4'-0"
1-HOUR RATED CEILING/
ROOF ASSEMBLY
(SEE NOTE 4)
STEEL
COLUMN
(TYP)
SEE
NOTE 5
NOTE: THE 1-HOUR
RATED CEILING/
ROOF ASSEMBLY,
(SEE NOTE 4)
CONTINUES OVER
THE ENTIRETY
ABOVE THE
CONTROL ROOM
ATTIC
DS DS
DS DS
LIGHTNING
PROTECTION AIR
TERMINAL - SEE
ELECTRICAL
R O
O F
S
L O
P E
R O
O
P E
GUTTER
WALL
OUTLINE
INTAKE LOUVER
PENTHOUSE
RIDGE CAP
EXHAUST
LOUVER
PENTHOUSE
STANDING
SEAM METAL
ROOF
DS
DS
SCALE: 1/4" = 1'-0"
4 0 4 8
F I
E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D
2 3
C
4 5
A
B
D A
T E
F I
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L O
T
S
C A
L E
P
L O
T
D
A T
E
S M
B L
D E
S C
R I P
T I O
N
C O
N T
R A
C T
SHEET
IDENTIFICATION
D A
T E
A P
P R
US Army Corps of Engineers
U S
A
R M
Y
C
O R
P
E
N G
I N
E E
R S
O M
A H
A
D
I S
T R
I C
T
O M
A H
A
N
E B
R A
S K
A
--S E
P T
E M
B E
R
A N
S I
D
OMAHA DISTRICT
S E
A L
D E
S C
S
R
E P
L A
C
U E
L
F
A C
I L
I T
I E
S
Q U
O N
S E
T
A
I R
T
I O
N A
L
G
U A
D
B
S
E
N O
R T
H
K
I N
G S
T O
W N
R
H O
I
L A
N D
R
READY TO ADVERTISE (RTA)
A-103
R E
F L
E C
T E
D
C
E I L
I N
G
A
O
F
P L
A N
S
M
H
I C
K S
M
H
I C
K S
M
H
I C
K S
C
L A
Y S
O N
A
D
W G
REFLECTED CEILING PLAN
SCALE: 1/4" = 1'-0"
ROOF PLAN
SCALE: 1/4" = 1'-0"
RCP NOTES:
LOCATE LIGHT FIXTURES, DIFFUSERS,
SPRINKLER HEADS AND OTHER
CEILING MOUNTED
FIXTURES/ACCESSORIES IN THE
CENTER OF SQUARE CEILING TILES.
ON FIXTURES AND/OR ACCESSORIES
TO BE MOUNTED ON THE WALL OR
CEILING, CENTER THE
FIXTURE/ACCESSORY ON
ARCHITECTURAL FEATURES (I.E.
ABOVE DOORS, WALL AREA, ETC.) AS
SHOWN ON RCP.
2-HOUR-RATED, FULL-HEIGHT CMU
FIRE WALL (IBC, SECTION 706)
AS PER 706.6, EXCEPTIONS 2.1, 2.2,
AND 2.3, THE FIREWALL SHALL
TERMINATE INTO A 1-HOUR RATED
CEILING/ROOF ASSEMBLY COVERING
THE COMPLETE FRAMING BAY
BETWEEN FRAMING BENTS 1 AND 2
AND EASTWARD, OUT TO 4'-0"
MINIMUM PERPENDICULAR FROM
FACE OF FIREWALL: z e " TYPE X GYP
BD ON 6" METAL STUDS FIXED TO
UNDERSIDES OF STEEL ROOF
PURLINS.
FILL CAVITY WITH 4 PCF MINERAL
WOOL BATT INSULATION
STEEL FRAMING BENTS 1 AND 2 CLAD
WITH 1-HOUR FIRE-RESISTIVE
ASSEMBLY
1.
2.
ROOF PLAN NOTES:
COORDINATE INSTALLATION OF SMALL
DIAMETER ROOF PENETRATIONS TO
ENSURE PENETRATION IS LOCATED
BETWEEN METAL ROOF PANEL
STANDING SEAM.
1.
RCP LEGEND:
ELECTRICAL:ARCHITECTURE:
UNIT HEATER
EXTERIOR LIGHT FIXTURE
RETURN GRILLE
SUPPLY DIFFUSER
EXIT LIGHT FIXTURE
ACOUSTICAL CEILING TILE --
2'-0" X 2'-0"
LED LIGHT FIXTURE -
2'-0" X 2'-0"
LED LIGHT FIXTURE -
1'-4" X 4'-0"
LED LIGHT FIXTURE -
2'-0" X 2'-0" (EMERGENCY LIGHT)
LED LIGHT FIXTURE -
1'-4" X 4'-0" (EMERGENCY LIGHT)
RATED FIRE WALL
2-HR
3.
4.
5.
A M
E N
D M
E N
T
H M
H
1-HR
FIRE RATED WALL
S
P
RENEWAL DATE
2/28/2021
C-38283
H. MASON
HICKS, AIA
| Sheets and Views |
| A-103 REFLECTED CEILING AND ROOF PLANS |
File details come from the government source that posted it. Updated .