M-403 TRUCK FILLSTAND PIPING LAYOUT PLAN AND ELEVATION.pdf

PDF 369 KB Posted

Attached to
Quonset Point Fuels Storage Complex Replacement Construction at the Rhode Island Air National Guard Station in North Kingstown, Rhode Island
Solicitation number
W912WJ20R0011
Issued by

About this file

This document provides details for a federal construction contract opportunity for the Quonset Point Fuels Storage Complex Replacement at the Rhode Island Air National Guard Station in North Kingstown, Rhode Island. The U.S. Army Corps of Engineers New England District will issue a solicitation to replace the truck offload and fillstand positions and associated pumping, filtration, and fuel distribution equipment. The work will include constructing a new 600 gallon per minute pumphouse with control room and offload skids; installing fuel pumps, filter/separator vessels, truck fillstand equipment, valves, piping and electrical components; and upgrading the existing refueler parking area. The estimated value of the contract is between $5 million and $10 million. The NAICS code is 236220. This will be a small business set-aside procurement using Best Value Tradeoff procedures. The solicitation number is W912WJ20R0011.

View the file

Other files

File Type Posted
Amendment 0010.pdf PDF
A-202 BUILDING SECTIONS.pdf PDF
Amendment 0009 - G-009 PHASING PLAN 1.pdf PDF
M-603 FUEL SYSTEM FLOW DIAGRAM (2 OF 2).pdf PDF
M-302 FUELING SYSTEM PIPING ELEVATIONS (2 OF 2).pdf PDF
Amendment 0009 - ES403 ENLARGED SITE PLAN (3 OF 4).pdf PDF
EP101 PUMP HOUSE POWER PLAN.pdf PDF
Amendment 0009 - ES404 ENLARGED SITE PLAN (4 OF 4).pdf PDF
A-002 CODE ANALYSIS.pdf PDF
A-103 REFLECTED CEILING AND ROOF PLANS.pdf PDF
ES101 ELECTRICAL OVERALL SITE PLAN.pdf PDF
Amendment 0009 - EP601 POWER DIAGRAMS AND SCHEDULES.pdf PDF
Amendment 0009 - Spec Section 01 22 00 - 05OCT20.pdf PDF
Amendment 0009.pdf PDF
Amendment 0009 - ES508 STORAGE TANK ELECTRICAL ELEVATION.pdf PDF
EP602 ELECTRICAL SCHEDULES.pdf PDF
Amendment 0009 - 26 24 19.00 40.pdf PDF
EP603 ELECTRICAL SCHEDULES.pdf PDF
Amendment 0009 - Schedule of Special Inspections.pdf PDF
E-001 ELECTRICAL LEGEND AND ABBREVIATIONS.pdf PDF
Quonset Modified document and comments.pdf PDF
ES507 PRODUCT RECOVERY TANK PLAN AND DETAIL.pdf PDF
EP604 ELECTRICAL SCHEDULES.pdf PDF
A-302 WALL SECTIONS AND DETAILS.pdf PDF
A-101 FLOOR PLAN.pdf PDF
Amendment 0008 - 03 30 00.pdf PDF
Amendment 0008 - G-013 MISCELLANEOUS WORK ITEMS AND NOTES.pdf PDF
Amendment 0008.pdf PDF
Amendment 0008 - 32 13 13.06.pdf PDF
Amendment 0008 - ES401 ENLARGED SITE PLAN (1 OF 4).pdf PDF
Amendment 0008 - 33 52 43.11.pdf PDF
Amendment 0008 - C-407 PUMPHOUSE AND PRT GRADING AND DRAINAGE PLAN - PHASE 1.pdf PDF
Amendment 0007.pdf PDF
Amendment 0006 - Wage Determination.pdf PDF
Amendment 0006 - 1802100MH-101-R1.pdf PDF
Amendment 0006 - 09 90 00 (Q - RTA - Bolded-2).pdf PDF
Amendment 0006 - 10 71 19.16 - Q - RTA - Bolded-2.pdf PDF
Amendment 0006.pdf PDF
Amendment 0006 - 33 56 19 - Q - RTA - Bolded-2.pdf PDF
Amendment 0006 - A-501 (SCHEDULES).pdf PDF
Amendment 0005.pdf PDF
Amendment 0004.pdf PDF
Amendment 0003.pdf PDF
Amendment 0002.pdf PDF
Amendment 0001.pdf PDF
Solicitation Drawing.zip ZIP file
Supplemental Price Breakdown to the Bidding Schedule.xlsx XLSX spreadsheet
Specs - Volume 1.pdf PDF
Specs - Volume 2.pdf PDF
W912WJ20R0011_Solicitation.pdf PDF
Show 40 more

Latest 50 of 51 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

4" - 300 GPM POSITIVE

DISPLACEMENT METER

3"

3" STAINLESS STEEL

PANTOGRAPH

D-2 NOZZLE AND

DRYBREAK DISCONNECT

FILLSTAND CONTROL

RACK W/ DEADMAN

HOSE SUPPORT

TYP. SAMPLE

CONNECTION

3"

4" TRUCK LOADING

CONTROL VALVE (TYP)

" CHECK VALVE

AND PIPING FOR

THERMAL RELIEF

MANUAL AIR VENT

6" TRUCK FILLSTAND SS

PIPING LOOP IN TRENCH

TYPICAL PRESSURE

GAUGE

CANOPY

COLUMNS

4" BASKET

STRAINER

PIPE

SUPPORT

CANOPY

COLUMNS

MAV

4" SS

6" x 4" TEE

6" x 4" TEE

4" SS

4" x 3"

REDUCER

4"

SWIVEL JOINTS (TYP)

3"

3"

4"

FLOW SWITCH

CANOPY

COLUMN

D

M-302

D

M-302

EXTERIOR PIPE SUPPORT,

SEE C-423 FOR SCHEDULE

TYPICAL PIPE SUPPORT IN

TRENCH, SEE C-423 & S-505 FOR

DETAILS AND ELEVATIONS

CANOPY ROOF

OUTLINE

CANOPY ROOF

OUTLINE

M-501

DEADMAN HOSE

SUPPORT DETAIL

6" SHORT RADIUS ELBOWS

(THIS LOCATION ONLY)

LOW POINT

DRAIN

M-502

LPD

M-501

EP-502

CANOPY

COLUMNS

LPD

M-502

C

M-302

C

M-302

C-503

EXTERIOR PIPE SUPPORT,

SEE C-423 FOR SCHEDULE

F I L E

N

A M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D

2 3

C

4 5

A

B

D A

T E

F I

U M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

P

L O

T

D

A T

E

S M

B L

D E

S C

R I P

T I O

N

C O

N T

R A

C T

O

SHEET

IDENTIFICATION

D A

T E

A P

P R

US Army Corps of Engineers

U S

A

R M

Y

C

O R

P S

O

F

E

N G

I N

E E

R S

O M

A H

A

D

I S

T R

I C

T

O M

A H

A

N

E B

R A

S K

A

--S E

P T

E M

B E

R

A N

S I

D

OMAHA DISTRICT

S E

A L

D E

S C

S

R

E P

L A

C

U E

L

F

A C

I L

I T

I E

S

Q U

O N

S E

T

A

I R

T

I O

N A

L

G

U A

R D

B

S

E

N O

R T

H

K

I N

G S

T O

W N

R

H O

S

L A

N D

R

READY TO ADVERTISE (RTA)

M-403

T R

U C

K

F

I L

L S

T A

P

I N

G

L

A Y

O U

T

P L

E

V A

T I O

N

M

S

O U

P R

A Y

E N

M

S

O U

P R

A Y

E N M

F

U R

R

C

L A

Y S

O N

M

D

W G

GRAPHIC SCALE

SCALE: 1/2" = 1'-0"

2 0 2 4

Scale:

TRUCK FILLSTAND PIPING LAYOUT PLAN

1/2" = 1'-0"

A

M E

N D

M E

T

S

M

H

Sheets and Views
M-403 TRUCK FILLSTAND PIPING LAYOUT PLAN AND ELEVATION

File details come from the government source that posted it. Updated .