IN102 - FLOOR FINISH PLAN - SECTOR B.pdf

PDF 1 MB Posted

Attached to
137th SOW - Building 1040 Repair / Renovation Project
Solicitation number
W50S8T25BA011
Issued by

About this file

This is a floor finish plan (drawing IN102) showing the detailed flooring specifications for Sector B of Building 1040 at Will Rogers Air National Guard Base. The plan includes a comprehensive finish legend that specifies various flooring types including carpet tiles (CPT1, CPT2, CPT3), electrostatic dissipative (ESD) resilient tile, porcelain tiles (PRC1, PRC2), raised access flooring (RAF), concrete treatments (CONC1, CONC2), and walk-off carpet tile (WOC1).

The drawing details room layouts and associated floor finishes for various spaces including offices, corridors, vestibules, mission planning areas, and multi-use rooms. General notes specify installation requirements such as Class A flame spread ratings, smooth transitions between different flooring materials, and specific installation parameters like tile centering and minimum piece sizes. The plan also includes requirements for floor leveling, protection of finishes during construction, and manufacturer-compliant installation methods. An addendum was issued on February 17, 2025, and the drawing is dated September 12, 2024.

View the file

Other files

File Type Posted
Abstract (Final).pdf PDF
Amendment 3 Attachment 1 - Bldg 1040 Reno Questions and Answers.docx DOCX document
Solicitation Amendment 3 W50S8T25BA0110003.pdf PDF
NEW 6 Mar 25 Oklahoma NGB-WRWA - 100 CD Set Part 1.pdf PDF
NEW 6 Mar 25 Oklahoma NGB-WRWA - 100 CD Set Part 2.pdf PDF
Amendment 2 Attachment 2 - 09 72 00.pdf PDF
Amendment 2 Attachment 5 - IN600 - INTERIORS MATERIALS LEGEND.pdf PDF
Amendment 2 Attachment 3 - A-002 - PARTITION TYPES.pdf PDF
Amendment 2 Attachment 6 - Bldg 1040 Reno Questions and Answers.xlsx XLSX spreadsheet
Amendment 2 Attachment 1 - Addendum 02 Narrative.docx DOCX document
Solicitation Amendment 2 W50S8T25BA0110002.pdf PDF
Amendment 2 Attachment 4 - 08 11 16.pdf PDF
06 20 00.pdf PDF
21 13 13.pdf PDF
IN101 - FLOOR FINISH PLAN - SECTOR A.pdf PDF
Bldg 1040 Reno Questions and Answers - FSB and GOV Reponses.xlsx XLSX spreadsheet
EL101 - ELECTRICAL INTERIOR LIGHTING PLAN - SECTOR A.pdf PDF
AE102 - FLOOR PLAN - SECTOR A.pdf PDF
AE502 - DETAILS.pdf PDF
AE403 - ENLARGED PLANS.pdf PDF
10 21 13.pdf PDF
10 51 13.pdf PDF
08 41 13.pdf PDF
AE103 - FLOOR PLAN - SECTOR B.pdf PDF
08 81 00.pdf PDF
AE411 - INTERIOR ELEVATIONS.pdf PDF
AE402 - ENLARGED PLANS.pdf PDF
AE601 - DOOR SCHEDULE AND DETAILS.pdf PDF
26 05 73.pdf PDF
08 11 16.pdf PDF
AE602 - OLI 1 - EXTERIOR WINDOW FRAMES.pdf PDF
Addendum 01 Narrative.docx DOCX document
08 71 00.pdf PDF
Solicitation Amendment 1 W50S8T25BA0110001 SF 30.pdf PDF
06 41 16.00 10.pdf PDF
AE201 - BUILDING ELEVATIONS.pdf PDF
TABLE OF CONTENTS.pdf PDF
A-002 - PARTITION TYPES.pdf PDF
01 45 35.pdf PDF
FA601 - FIRE ALARM - MASS NOTIFICATION RISER DIAGRAM.pdf PDF
AE151 - REFLECTED CEILING PLAN - SECTOR A.pdf PDF
AE600 - ROOM FINISH SCHEDULE.pdf PDF
10 51 16.pdf PDF
30 Jan 25 Site Visit Sign In Sheet.pdf PDF
BLDG 1040 Renovation Site Visit Slides 30 January 25.pptx PPTX presentation
ATTACHMENT 3 - 2024.09.12_OK-ANG_SQUADOPS B1040_TYPE B3_SPECIFICATIONS VOL. 2.pdf PDF
Solicitation - W50S8T25BA011.pdf PDF
ATTACHMENT 2 - 2024.09.12_OK-ANG_SQUADOPS B1040_TYPE B3_SPECIFICATIONS VOL. 1.pdf PDF
Bidders Checklist.docx DOCX document
ATTACHMENT 1 - 2024.09.12_OK-ANG_SQUADOPS B1040_TYPE B3_DRAWINGS.pdf PDF
Show all 50

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FINISH LEGEND

ETR: EXISTING FLOORING TO REMAIN

CPT1: CARPET TILE, 24" X 24"

CPT2: ESD CARPET TILE, 24" X 24"

CPT3: CARPET PLANKS, 24" X 36", HALF

OFFSET

ESD1: ELECTROSTATIC DISSIPATIVE

RESILIENT TILE

PRC2: PORCELAIN TILE - UNPOLISHED,

12" X 24", 1/3 OFFSET

PRC1: ACCENT PORCELAIN FLOOR TILE

RAF: RAISED ACCESS FLOOR WITH CARPET.

CPT2 ON RAISED ACCESS FLOOR, REFER

SECTION 09 69 00 ACCESS FLOORING FOR

ADDITIONAL REQUIREMENTS

RAF: RAISED ACCESS FLOOR WITH ETR

CONC1: PENETRATING LIQUID FLOOR

TREATMENT

CONC2: ELECTROSTATIC DISSIPATIVE

CONCRETE TREATMENT OR EPOXY.

WOC1: WALK OFF CARPET TILE

G H K

NMLJ

4b

5b

6b

7b

8b

9b

10b

11b

N'

M'

L' k'

EA/ADMIN

C.A.T.

CORR.

MEN

VEST.

CMNDR.

CHF.

1ST SGT.

OFFICE

OFFICE

MECH

ELEC

UNISEX

CORR

MISSION

PLANNING

AFM

CORR

VEST

VEST

SEC COMM

SPECIAL OPS

(S.O.S.)

VEST.

SERE

HARM

BRIEFING

BRIEFING

OFFICE

OFFICE

WX

JANITOR

SHOWER

A/V ROOM

M

AT

C H

LI

N

E

SE

E A

/ I

N

M

AT

C

H

LI

N E

SE

E

A

/ I N

A/V ROOM

MULTI-USE

174B

MULTI-USE

174A

EXTENT OF CONCRETE

STAGE BELOW NEW ACCESS

PANEL FLOOR SYSTEM

STAGE ACCESS STAIRS

THIS AREA TO BE FILLED

IN WITH CONCRETE TO

ACCOMODATE THE NEW

CARPET TILE (CPT2)

FLOOR AT 106'-0"

SHOP

VEST.

OPEN OFFICE

AWP1

OPEN OFFICE

BREAK RM

PT3

V

UP

PT3

PT3

PT3

PT

PT

PT2

PT2

PT2

PT3ELEC.

PT3PT3

(INTERIOR INSTALLATION) PRIVACY FILM ON THESE WINDOWS;

(INTERIOR INSTALLATION) WINDOW TREATMENT

12" ACCENT TILE BAND

(ONE FULL TILE OF PRC1)

AWP1

W T1

WT1

WT1

WT1

WT1

WT1

WT1WT1WT1

WT1

WT1

O N

IN

TE

R

IIO

R

SI

D E

O F

W

IN

D O

W O

N

IN

TE

R

IIO

R

SI

D

E O

F W

IN

D

O W

ON INTERIIOR

SIDE OF WINDOW

ON INTERIIOR

SIDE OF WINDOW

ON INTERIIOR

SIDE OF WINDOW

GENERAL NOTES

A. ALL INTERIOR FINISHES SHALL HAVE CLASS A

FLAME SPREAD RATING.

B. ALL FLOORING IS NEW UNLESS NOTED

OTHERWISE.

C. FLOORING TRANSITION TO BE LOCATED UNDER

DOOR IN CLOSED POSITION.

D. EXTEND FLOORING MATERIALS INTO ALL

KNEESPACES, TOE SPACES, ETC.

E. PROVIDE SMOOTH TRANSITION BETWEEN

DIFFERENT FLOORING MATERIALS.

F. THERE SHALL BE NO FLOOR TILE PIECES

INSTALLED LESS THAN 3”. COORDINATE WITH

ARCHITECT PRIOR TO INSTALLATION.

G. ALL TILED FLOORING INSTALLATIONS SHALL

BEGIN WITH A FULL TILE CENTERED IN ROOM,

UNLESS NOTED OTHERWISE. IF CENTERING FULL

TILE RESULTS IN LESS THAN 6” WIDE AT THE

PERIMETER OF THE ROOM, ADJUST START POINT

BY HALF TILE WIDTH IN BOTH DIRECTIONS.

H. VARIATIONS IN FLOOR LEVEL IN EXCESS OF 1/2"

FOR EVERY 10'-0" SHALL BE LEVELED BY

CONSTRACTOR. LEVELING SHALL BE

COMPLETED WITH FLOOR READY TO RECEIVE

NEW FINISHES AS SPECIFIED. CONTRACTOR

SHALL VERIFY SLAB CONDITION PRIOR TO BID

SUBMISSION.

I. ALL MISCELLANEOUS GRILLES, PLATES OR

OTHER DEVICES SHALL BE PAINTED TO MATCH

THE WALL OR CEILING IN WHICH THEY ARE

INSTALLED.

J. G.C. SHALL BE RESPONSIBLE FOR PROVIDING

BLOCKING AS RQUIRED FOR ALL ITEMS

INCLUDING BUT NOT LIMITED TO CABINETS,

TOILET ACCESSORIES AND FF&E.

K. ALL NEW WALL CONSTRUCTION AND/OR WALL,

CEILING AND FLOOR INFILL THAT TIES INTO

EXISTING CONSTRUCTION SHALL BE FURRED OUT

AS REQUIRED TO ALIGN WITH EXISTING

ADJACENT OR ABUTTING. ALL SEAMS AND

JOINTS SHALL BE FULLY CONCEALED, TYPICAL

THROUGHOUT.

L. G.C. IS RESPONSIBLE FOR REPAIRS FOR ANY

DAMAGE TO NEW OR EXISTING ITEMS DUE TO

CONSTRUCTION WORK, TYPICAL. FULLY

PROTECT ALL FINISHES DUE TO CONSTRUCTION

WORK. CONTRACTOR IS FULLY RESPONSIBLE

FOR REPAIRING ANY DAMAGES, NICKS,

SCRATCHES.

M. PATCH AND SAND ALL EXISTING WALLS THAT

WERE DAMAGED OR HAD ITEMS REMOVED.

WALLS, COLUMNS, SOFFITS, ETC. TO BE READY

FOR PAINT.

N. INTERIOR PAINTING SHALL INCLUDE ALL PREP

WORK, ONE COAT PRIMER AND TWO COATS

FINISH. REFER TO SECTION 09 90 00 PAINTS AND

COATINGS.

O. FLOORING AND BASE: ALL FLOORING SHALL BE

INSTALLED PER MANUFACTURER'S

RECOMMENDATIONS REGARDING ADHESIVES,

SEAMING, DIRECTION, ETC. AND SHALL BE

COMPLIANT WITH SPECIFICATIONS.

DISCREPANCIES ARE TO BE BROUGHT TO THE

ATTENTION OF THE INTERIOR DESIGNER.

P. ALL PAINT COLORS SHALL BE REVIEWED WITH

THE INTERIOR DESIGNER AND GOVERNMENT

PRIOR TO PAINTING.

Q. PROVIDE 1" ALUMINUM MINI-BLINDS AT ALL

EXTERIOR WINDOWS.

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

Frankfurt-Short-Bruza Associates,P.C.

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

C

B

A

D

C

B

A

54321

2020-484-00

NDM

Re pa ir/ Co nv er t S qu ad O ps Ok lah om a C ity

, O K

NG

BJ

V/

OK

A

NG

PN: YZEU142025

C :\U sers\tw ood\ O neD rive - FS

B Architects + Engineers\D ocu m ents\048400_A

R C

H _tw oodD

XX

EM

.rvt

2/14/2025 3:19: 26 PM

12 SEPTEMBER 2024

FLOOR FINISH PLAN - SECTOR

B

IN102

TLW

KD

KD

0 4' 8' 16'

1/8" = 1'-0"

N

PROJECT

KEYPLANN

A B

SCALE: 1/8" = 1'-0"

FLOOR FINISH PLAN - SECTOR 'B'A2

IN

STALL O

N INTER

IO

R SIDE

O F W

IND

O

W

2 ADDENDUM 01 02/17/2025

File details come from the government source that posted it. Updated .