IN102 - FLOOR FINISH PLAN - SECTOR B.pdf
PDF 1 MB Posted
- Solicitation number
- W50S8T25BA011
- Issued by
-
Department of the Army National Guard
About this file
This is a floor finish plan (drawing IN102) showing the detailed flooring specifications for Sector B of Building 1040 at Will Rogers Air National Guard Base. The plan includes a comprehensive finish legend that specifies various flooring types including carpet tiles (CPT1, CPT2, CPT3), electrostatic dissipative (ESD) resilient tile, porcelain tiles (PRC1, PRC2), raised access flooring (RAF), concrete treatments (CONC1, CONC2), and walk-off carpet tile (WOC1).
The drawing details room layouts and associated floor finishes for various spaces including offices, corridors, vestibules, mission planning areas, and multi-use rooms. General notes specify installation requirements such as Class A flame spread ratings, smooth transitions between different flooring materials, and specific installation parameters like tile centering and minimum piece sizes. The plan also includes requirements for floor leveling, protection of finishes during construction, and manufacturer-compliant installation methods. An addendum was issued on February 17, 2025, and the drawing is dated September 12, 2024.
View the file
Other files
Show all 50
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FINISH LEGEND
ETR: EXISTING FLOORING TO REMAIN
CPT1: CARPET TILE, 24" X 24"
CPT2: ESD CARPET TILE, 24" X 24"
CPT3: CARPET PLANKS, 24" X 36", HALF
OFFSET
ESD1: ELECTROSTATIC DISSIPATIVE
RESILIENT TILE
PRC2: PORCELAIN TILE - UNPOLISHED,
12" X 24", 1/3 OFFSET
PRC1: ACCENT PORCELAIN FLOOR TILE
RAF: RAISED ACCESS FLOOR WITH CARPET.
CPT2 ON RAISED ACCESS FLOOR, REFER
SECTION 09 69 00 ACCESS FLOORING FOR
ADDITIONAL REQUIREMENTS
RAF: RAISED ACCESS FLOOR WITH ETR
CONC1: PENETRATING LIQUID FLOOR
TREATMENT
CONC2: ELECTROSTATIC DISSIPATIVE
CONCRETE TREATMENT OR EPOXY.
WOC1: WALK OFF CARPET TILE
G H K
NMLJ
4b
5b
6b
7b
8b
9b
10b
11b
N'
M'
L' k'
EA/ADMIN
C.A.T.
CORR.
MEN
VEST.
CMNDR.
CHF.
1ST SGT.
OFFICE
OFFICE
MECH
ELEC
UNISEX
CORR
MISSION
PLANNING
AFM
CORR
VEST
VEST
SEC COMM
SPECIAL OPS
(S.O.S.)
VEST.
SERE
HARM
BRIEFING
BRIEFING
OFFICE
OFFICE
WX
JANITOR
SHOWER
A/V ROOM
M
AT
C H
LI
N
E
SE
E A
/ I
N
M
AT
C
H
LI
N E
SE
E
A
/ I N
A/V ROOM
MULTI-USE
174B
MULTI-USE
174A
EXTENT OF CONCRETE
STAGE BELOW NEW ACCESS
PANEL FLOOR SYSTEM
STAGE ACCESS STAIRS
THIS AREA TO BE FILLED
IN WITH CONCRETE TO
ACCOMODATE THE NEW
CARPET TILE (CPT2)
FLOOR AT 106'-0"
SHOP
VEST.
OPEN OFFICE
AWP1
OPEN OFFICE
BREAK RM
PT3
V
UP
PT3
PT3
PT3
PT
PT
PT2
PT2
PT2
PT3ELEC.
PT3PT3
(INTERIOR INSTALLATION) PRIVACY FILM ON THESE WINDOWS;
(INTERIOR INSTALLATION) WINDOW TREATMENT
12" ACCENT TILE BAND
(ONE FULL TILE OF PRC1)
AWP1
W T1
WT1
WT1
WT1
WT1
WT1
WT1WT1WT1
WT1
WT1
O N
IN
TE
R
IIO
R
SI
D E
O F
W
IN
D O
W O
N
IN
TE
R
IIO
R
SI
D
E O
F W
IN
D
O W
ON INTERIIOR
SIDE OF WINDOW
ON INTERIIOR
SIDE OF WINDOW
ON INTERIIOR
SIDE OF WINDOW
GENERAL NOTES
A. ALL INTERIOR FINISHES SHALL HAVE CLASS A
FLAME SPREAD RATING.
B. ALL FLOORING IS NEW UNLESS NOTED
OTHERWISE.
C. FLOORING TRANSITION TO BE LOCATED UNDER
DOOR IN CLOSED POSITION.
D. EXTEND FLOORING MATERIALS INTO ALL
KNEESPACES, TOE SPACES, ETC.
E. PROVIDE SMOOTH TRANSITION BETWEEN
DIFFERENT FLOORING MATERIALS.
F. THERE SHALL BE NO FLOOR TILE PIECES
INSTALLED LESS THAN 3”. COORDINATE WITH
ARCHITECT PRIOR TO INSTALLATION.
G. ALL TILED FLOORING INSTALLATIONS SHALL
BEGIN WITH A FULL TILE CENTERED IN ROOM,
UNLESS NOTED OTHERWISE. IF CENTERING FULL
TILE RESULTS IN LESS THAN 6” WIDE AT THE
PERIMETER OF THE ROOM, ADJUST START POINT
BY HALF TILE WIDTH IN BOTH DIRECTIONS.
H. VARIATIONS IN FLOOR LEVEL IN EXCESS OF 1/2"
FOR EVERY 10'-0" SHALL BE LEVELED BY
CONSTRACTOR. LEVELING SHALL BE
COMPLETED WITH FLOOR READY TO RECEIVE
NEW FINISHES AS SPECIFIED. CONTRACTOR
SHALL VERIFY SLAB CONDITION PRIOR TO BID
SUBMISSION.
I. ALL MISCELLANEOUS GRILLES, PLATES OR
OTHER DEVICES SHALL BE PAINTED TO MATCH
THE WALL OR CEILING IN WHICH THEY ARE
INSTALLED.
J. G.C. SHALL BE RESPONSIBLE FOR PROVIDING
BLOCKING AS RQUIRED FOR ALL ITEMS
INCLUDING BUT NOT LIMITED TO CABINETS,
TOILET ACCESSORIES AND FF&E.
K. ALL NEW WALL CONSTRUCTION AND/OR WALL,
CEILING AND FLOOR INFILL THAT TIES INTO
EXISTING CONSTRUCTION SHALL BE FURRED OUT
AS REQUIRED TO ALIGN WITH EXISTING
ADJACENT OR ABUTTING. ALL SEAMS AND
JOINTS SHALL BE FULLY CONCEALED, TYPICAL
THROUGHOUT.
L. G.C. IS RESPONSIBLE FOR REPAIRS FOR ANY
DAMAGE TO NEW OR EXISTING ITEMS DUE TO
CONSTRUCTION WORK, TYPICAL. FULLY
PROTECT ALL FINISHES DUE TO CONSTRUCTION
WORK. CONTRACTOR IS FULLY RESPONSIBLE
FOR REPAIRING ANY DAMAGES, NICKS,
SCRATCHES.
M. PATCH AND SAND ALL EXISTING WALLS THAT
WERE DAMAGED OR HAD ITEMS REMOVED.
WALLS, COLUMNS, SOFFITS, ETC. TO BE READY
FOR PAINT.
N. INTERIOR PAINTING SHALL INCLUDE ALL PREP
WORK, ONE COAT PRIMER AND TWO COATS
FINISH. REFER TO SECTION 09 90 00 PAINTS AND
COATINGS.
O. FLOORING AND BASE: ALL FLOORING SHALL BE
INSTALLED PER MANUFACTURER'S
RECOMMENDATIONS REGARDING ADHESIVES,
SEAMING, DIRECTION, ETC. AND SHALL BE
COMPLIANT WITH SPECIFICATIONS.
DISCREPANCIES ARE TO BE BROUGHT TO THE
ATTENTION OF THE INTERIOR DESIGNER.
P. ALL PAINT COLORS SHALL BE REVIEWED WITH
THE INTERIOR DESIGNER AND GOVERNMENT
PRIOR TO PAINTING.
Q. PROVIDE 1" ALUMINUM MINI-BLINDS AT ALL
EXTERIOR WINDOWS.
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
Frankfurt-Short-Bruza Associates,P.C.
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
2020-484-00
NDM
Re pa ir/ Co nv er t S qu ad O ps Ok lah om a C ity
, O K
NG
BJ
V/
OK
A
NG
PN: YZEU142025
C :\U sers\tw ood\ O neD rive - FS
B Architects + Engineers\D ocu m ents\048400_A
R C
H _tw oodD
XX
EM
.rvt
2/14/2025 3:19: 26 PM
12 SEPTEMBER 2024
FLOOR FINISH PLAN - SECTOR
B
IN102
TLW
KD
KD
0 4' 8' 16'
1/8" = 1'-0"
N
PROJECT
KEYPLANN
A B
SCALE: 1/8" = 1'-0"
FLOOR FINISH PLAN - SECTOR 'B'A2
IN
STALL O
N INTER
IO
R SIDE
O F W
IND
O
W
2 ADDENDUM 01 02/17/2025
File details come from the government source that posted it. Updated .