08 41 13.pdf
PDF 87 KB Posted
- Solicitation number
- W50S8T25BA011
- Issued by
-
Department of the Army National Guard
About this file
This is a technical specification section (08 41 13) for aluminum-framed entrances and storefronts for the 137th SOW Oklahoma ANG Building 1040 repair project. The specification details requirements for aluminum entrance systems with medium stile doors having 4 1/2 inch vertical face dimensions and 2-inch depth for interior structural silicone glazing in high-traffic/impact-resistant applications.
Key requirements include: aluminum components must use ASTM B221 6063-T5 alloy with minimum 20% recycled content; door stiles and rails must be 3-1/2 inches for vertical stiles and top rails, 6-1/2 inches for bottom rails, with 0.125-inch nominal thickness; thermal barrier separation between exterior and interior aluminum; weatherstripping using EPDM or thermoplastic elastomer gaskets; requirements for air infiltration testing (max 1.2 cfm/sq ft for door pairs), water penetration testing at 8 psf static pressure, and thermal performance (U-value max 0.65 BTU/hr/sf/deg F). The manufacturer must provide a 5-year warranty on the entrance system and lifetime warranty on welded door corner construction.
View the file
Other files
Show all 50
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
137TH SOW OKLAHOMA ANG B- 3 100% REPAI R BUI LDI NG 1040
OKLAHOMA CI TY, OK 12 SEPTEMBER, 2024
SECTI ON 08 41 13
ALUMI NUM- FRAMED ENTRANCES AND STOREFRONTS
08/ 18, CHG 1: 08/ 18
PART 1 GENERAL
1. 1 REFERENCES
The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.
ALUMI NUM ASSOCI ATI ON ( AA)
AA DAF45 ( 2003; Reaf f i r med 2009) Desi gnat i on Syst em f or Al umi num Fi ni shes
AMERI CAN ARCHI TECTURAL MANUFACTURERS ASSOCI ATI ON ( AAMA)
AAMA 501 ( 2015) Met hods of Test f or Ext er i or Wal l s
AAMA 800 ( 2016) Vol unt ar y Speci f i cat i ons and Test Met hods f or Seal ant s
AAMA 1503 ( 2009) Vol unt ar y Test Met hod f or Ther mal Tr ansmi t t ance and Condensat i on Resi st ance of Wi ndows, Door s and Gl azed Wal l Sect i ons
AAMA 2605 ( 2020) Vol unt ar y Speci f i cat i on, Per f or mance Requi r ement s and Test Pr ocedur es f or Super i or Per f or mi ng Or gani c Coat i ngs on Al umi num Ext r usi ons and Panel s
AMERI CAN SOCI ETY OF CI VI L ENGI NEERS ( ASCE)
ASCE 7- 16 ( 2017; Er r at a 2018; Supp 1 2018) Mi ni mum Desi gn Loads and Associ at ed Cr i t er i a f or Bui l di ngs and Ot her St r uct ur es
ASTM I NTERNATI ONAL ( ASTM)
ASTM B221 ( 2021) St andar d Speci f i cat i on f or Al umi num and Al umi num- Al l oy Ext r uded Bar s, Rods, Wi r e, Pr of i l es, and Tubes
ASTM E283 ( 2019) St andar d Test Met hod f or Det er mi ni ng t he Rat e of Ai r Leakage Thr ough Ext er i or Wi ndows, Cur t ai n Wal l s, and Door s Under Speci f i ed Pr essur e Di f f er ences Acr oss t he Speci men
ASTM E330/ E330M ( 2014; R 2021) St andar d Test Met hod f or St r uct ur al Per f or mance of Ext er i or Wi ndows, Door s, Skyl i ght s and Cur t ai n Wal l s by Uni f or m St at i c Ai r Pr essur e Di f f er ence
SECTI ON 08 41 13 Page 1
Gallagher, Brad K.
Text Box
ADDENDUM #1 - 02/17/2025
Gallagher, Brad K.
Cloud
ASTM E331 ( 2000; R 2023) St andar d Test Met hod f or Wat er Penet r at i on of Ext er i or Wi ndows, Skyl i ght s, Door s, and Cur t ai n Wal l s by Uni f or m St at i c Ai r Pr essur e Di f f er ence
ASTM E783 ( 2002; R 2018) St andar d Test Met hod f or Fi el d Measur ement of Ai r Leakage Thr ough I nst al l ed Ext er i or Wi ndows and Door s
ASTM E1105 ( 2015; R 2023) St andar d Test Met hod f or Fi el d Det er mi nat i on of Wat er Penet r at i on of I nst al l ed Ext er i or Wi ndows, Skyl i ght s, Door s, and Cur t ai n Wal l s, by Uni f or m or Cycl i c St at i c Ai r Pr essur e Di f f er ence
ASTM E1424 ( 2022) St andar d Test Met hod f or Det er mi ni ng t he Rat e of Ai r Leakage Thr ough Ext er i or Wi ndows, Cur t ai n Wal l s, and Door s Under Speci f i ed Pr essur e and Temper at ur e Di f f er ences Acr oss t he Speci men
ASTM E1886 ( 2019) St andar d Test Met hod f or Per f or mance of Ext er i or Wi ndows, Cur t ai n Wal l s, Door s, and I mpact Pr ot ect i ve Syst ems I mpact ed by Mi ssi l e( s) and Exposed t o Cycl i c Pr essur e Di f f er ent i al s
ASTM F1642/ F1642M ( 2017) St andar d Test Met hod f or Gl azi ng and Gl azi ng Syst ems Subj ect t o Ai r bl ast Loadi ngs
BUI LDERS HARDWARE MANUFACTURERS ASSOCI ATI ON ( BHMA)
ANSI / BHMA A156. 4 ( 2013) Door Cont r ol s - Cl oser s
ANSI / BHMA A156. 10 ( 2017) Power Oper at ed Pedest r i an Door s
I NTERNATI ONAL CODE COUNCI L ( I CC)
I CC I BC ( 2021) I nt er nat i onal Bui l di ng Code
U. S. GENERAL SERVI CES ADMI NI STRATI ON ( GSA)
FS TT- P- 645 ( Rev C; Not i ce 1) Pr i mer , Pai nt , Zi nc- Mol ybdat e, Al kyd Type
UNDERWRI TERS LABORATORI ES ( UL)
UL 325 ( 2017; Repr i nt Feb 2020) UL St andar d f or Saf et y Door , Dr aper y, Gat e, Louver , and Wi ndow Oper at or s and Syst ems
1. 2 ADMI NI STRATI VE REQUI REMENTS
1. 2. 1 Pr e- I nst al l at i on Meet i ngs
Conduct a meet i ng bef or e i nst al l at i on begi ns t o ver i f y t he pr oj ect r equi r ement s, subst r at e condi t i ons, manuf act ur er ' s i nst al l at i on i nst r uct i ons, and manuf act ur er ' s war r ant y r equi r ement s.
SECTI ON 08 41 13 Page 2
Wi t hi n 30 days of t he Cont r act Awar d, submi t t he f ol l owi ng f or r evi ew and appr oval by t he Cont r act i ng Of f i cer :
a. Li st of pr oduct i nst al l at i ons
b. Sampl e war r ant y
c. Fi ni sh and col or sampl es
d. Manuf act ur er ' s cat al og dat a
Concur r ent l y submi t cer t i f i ed t est r epor t s showi ng compl i ance wi t h speci f i ed per f or mance char act er i st i cs and UL 325 f or t he f ol l owi ng:
a. Wi nd Load ( Resi st ance) i n accor dance wi t h AAMA 501
b. Def l ect i on i n accor dance wi t h ASTM F1642/ F1642M
c. Condensat i on Resi st ance and Ther mal Tr ansmi t t ance Per f or mance Requi r ement s i n accor dance wi t h AAMA 1503
d. Wat er I nf i l t r at i on i n accor dance wi t h ASTM E331
e. St r uct ur al Requi r ement s i n accor dance wi t h ASTM F1642/ F1642M
1. 3 SUBMI TTALS
Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" c l assi f i cat i on.
Submi t t al s not havi ng a " G" c l assi f i cat i on ar e f or Cont r act or Qual i t y Cont r ol appr oval . Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00
SUBMI TTAL PROCEDURES:
SD- 01 Pr econst r uct i on Submi t t al s
Sampl e War r ant y; G
Li st of Pr oduct I nst al l at i ons; G
SD- 02 Shop Dr awi ngs
I nst al l at i on Dr awi ngs; GFabr i cat i on Dr awi ngs; G SD- 03 Pr oduct Dat a
Manuf act ur er ' s Cat al og Dat a; G
Fi ni sh; G
Recycl ed Cont ent of Al umi num Mat er i al ; S
SD- 04 Sampl es
Fi ni sh and Col or Sampl es; G
SD- 06 Test Repor t s
Cer t i f i ed Test Repor t s; G
Def l ect i on
SECTI ON 08 41 13 Page 3
Ai r I nf i l t r at i on
Condensat i on Resi st ance and Ther mal Tr ansmi t t ance
Wat er I nf i l t r at i on
SD- 08 Manuf act ur er ' s I nst r uct i ons
Manuf act ur er ' s I nst r uct i ons
SD- 11 Cl oseout Submi t t al s
Manuf act ur er ' s Pr oduct War r ant y
1. 4 QUALI TY CONTROL
1. 4. 1 Qual i f i cat i ons
1. 4. 1. 1 I nst al l er Qual i f i cat i ons
Pr ovi de document at i on of t he i nst al l er ' s exper i ence as det er mi ned by t he Cont r act or i n per f or mi ng t he wor k speci f i ed i n t hi s sect i on.
Ensur e t hat t he i nst al l er s ar e speci al i zed i n wor k s i mi l ar t o t hat r equi r ed f or t hi s pr oj ect , and t hat t hey ar e accept abl e t o pr oduct manuf act ur er .
1. 4. 1. 2 Manuf act ur er Qual i f i cat i ons
Ensur e t hat manuf act ur er s meet t he r equi r ement s speci f i ed i n t hi s sect i on and pr oj ect dr awi ngs.
Ensur e t hat t he manuf act ur er i s capabl e of pr ovi di ng f i el d ser vi ce r epr esent at i on dur i ng const r uct i on, appr ovi ng accept abl e i nst al l er s and appr ovi ng appl i cat i on met hods.
1. 4. 2 Si ngl e- Sour ce Responsi bi l i t y
When al umi num ent r ances ar e par t of a bui l di ng encl osur e syst em, t hat i ncl udes st or ef r ont f r ami ng, wi ndows, a cur t ai n wal l syst em, and r el at ed pr oduct s, pr ovi de bui l di ng encl osur e syst em pr oduct s f r om a si ngl e- sour ce manuf act ur er .
Use a s i ngl e sour ce manuf act ur er wi t h sol e r esponsi bi l i t y f or pr ovi di ng desi gn, st r uct ur al engi neer i ng, and cust om f abr i cat i on f or door por t al syst ems and f or suppl y i ng component s, mat er i al s, and pr oduct s. Do not use pr oduct s pr ovi ded f r om numer ous sour ces f or assembl y at t he s i t e. Ensur e t hat t he f ol l owi ng wor k i t ems and component s ar e f abr i cat ed or suppl i ed by a s i ngl e sour ce ar e:
a. Door assembl i es t o be i nst al l ed i n door por t al s as speci f i ed i n Sect i on 08 11 16 ALUMI NUM DOORS AND FRAMES.
b. Gl azed wal l s t o be const r uct ed ar ound door por t al s as speci f i ed i n .
c. Door oper at i ng har dwar e t o be i nst al l ed on or wi t hi n door por t al s as speci f i ed i n Sect i on 08 71 00 DOOR HARDWARE.
SECTI ON 08 41 13 Page 4
d. Gl ass as speci f i ed i n Sect i on 08 81 00 GLAZI NG.
1. 5 DELI VERY, STORAGE, AND HANDLI NG
1. 5. 1 Or der i ng
To avoi d const r uct i on del ays, compl y wi t h t he manuf act ur er ' s l ead- t i me r equi r ement s and i nst r uct i ons f or or der i ng.
1. 5. 2 Packi ng, Shi ppi ng, Handl i ng and Unl oadi ng
Del i ver mat er i al s i n t he manuf act ur er ' s or i gi nal , unopened, undamaged cont ai ner s wi t h i dent i f i cat i on l abel s i nt act .
1. 5. 3 St or age and Pr ot ect i on
St or e mat er i al s i n a way t hat pr ot ect s t hem f r om exposur e t o har mf ul weat her condi t i ons. Avoi d damagi ng t he st or ef r ont mat er i al and component s dur i ng handl i ng. Pr ot ect st or ef r ont mat er i al agai nst damage f r om el ement s, const r uct i on act i v i t i es, and ot her hazar ds bef or e, dur i ng, and af t er st or ef r ont i nst al l at i on.
Do not use adhesi ve paper s or spr ayed coat i ngs t hat become f i r ml y bonded when exposed t o sunl i ght . Do not l eave coat i ng r esi due on sur f aces.
1. 6 PROJECT / SI TE CONDI TI ONS
1. 6. 1 Fi el d Measur ement s
Ver i f y act ual measur ement s or openi ngs by t aki ng f i el d measur ement s bef or e f abr i cat i on; r ecor d t hese measur ement s on shop dr awi ngs. To avoi d const r uct i on del ays, coor di nat e f i el d measur ement s, and f abr i cat i on schedul e wi t h const r uct i on pr ogr ess.
1. 7 WARRANTY
Pr ovi de a wr i t t en manuf act ur er ' s war r ant y, execut ed by a company of f i c i al , war r ant i ng agai nst def ect s i n mat er i al s and pr oduct s f or 2 year s f r om t he dat e of shi pment . War r ant t hat t he door cor ner const r uct i on i s f or t he l i f e of t he pr oj ect . Pr ovi de a wr i t t en i nst al l er ' s war r ant y, war r ant i ng wor k t o be wat er t i ght and f r ee f r om def ect i ve mat er i al s, def ect i ve wor kmanshi p, and gl ass br eakage as a r esul t of def ect i ve desi gn, and agr eei ng t o r epl ace component s t hat f ai l wi t hi n 2 year s.
The war r ant y st at es t he f ol l owi ng:
a. Wat er t i ght and ai r t i ght syst em i nst al l at i on i s compl et ed wi t hi n speci f i ed t ol er ances.
b. The compl et ed i nst al l at i on r emai ns f r ee of r at t l es, wi nd whi st l es and noi se caused by t her mal movement and wi nd pr essur e.
c. Syst em i s st r uct ur al l y sound and f r ee f r om di st or t i on.
d. Gl ass and gl azi ng gasket s wi l l not br eak or " pop" f r om f r ames as a r esul t of desi gn, wi nd l oad pr essur e, movement caused by expansi on or cont r act i on, or st r uct ur al l oadi ng.
e. Gl azi ng seal ant s and gasket s r emai n f r ee of abnor mal det er i or at i on or
SECTI ON 08 41 13 Page 5 di s l ocat i on as a r esul t of sunl i ght , weat her , or oxi dat i on.
Pr ovi de wr i t t en war r ant y st at i ng t hat t he or gani c coat i ng f i ni sh wi l l not f ade mor e t han 10 per cent or show chal k i ng, yel l owi ng, peel i ng, cr acki ng, pi t t i ng, cor r odi ng or var i at i ons i n col or , or gl oss det er i or at i on beyond t he manuf act ur er ' s descr i pt i ve st andar ds f or 20 year s f r om t he shi pment dat e and agr eei ng t o pr ompt l y cor r ect def ect s.
Pr ovi de a wr i t t en t her mal i nt egr i t y war r ant y f or 5 year s f r om shi p dat e agai nst t her mal bar r i er syst em f ai l ur e r esul t i ng f r om t he f ol l owi ng:
a. Longi t udi nal and t r ansver se t her mal bar r i er shr i nkage.
b. Ther mal bar r i er cr acki ng.
c. St r uct ur al f ai l ur e of t he t her mal bar r i er mat er i al .
d. Loss of adhesi on or l oss of pr escr i bed edge pr essur e on gl azi ng mat er i al , r esul t i ng i n excessi ve ai r and wat er i nf i l t r at i on.
PART 2 PRODUCTS
2. 1 SYSTEM DESCRI PTI ON
Pr ovi de al umi num ent r ances, wi t h gl ass and gl azi ng, door har dwar e, and component s.
Al umi num ent r ances i ncl ude i mpact r esi st ance ent r ances; medi um st i l e, 4 1/ 2 i nch ver t i cal f ace di mensi on, 2 i nch dept h, f or i nt er i or st r uct ur al s i l i cone gl aze, f or hi gh- t r af f i c / i mpact - r esi st ant appl i cat i ons.
2. 1. 1 Desi gn Requi r ement s f or Al umi num ( Ent r ances and Component s)
Pr ovi de a door por t al syst em desi gned t o wi t hst and t he f ol l owi ng l oads wi t hout br eakage, l oss, f ai l ur e of seal s, pr oduct det er i or at i on, or ot her def ect s.
a. Dead and Li ve Loads: Det er mi ned by ASCE 7- 16 and cal cul at ed i n accor dance wi t h appl i cabl e codes.
b. Sei smi c Loads: Desi gn and i nst al l t he syst em t o compl y wi t h t he sei smi c r equi r ement s f or t he pr oj ect l ocat i on i n accor dance wi t h Sect i on 1613 of t he I nt er nat i onal Bui l di ng Code, I CC I BC.
c. Wi nd Loads: Desi gn and i nst al l t he syst em so t hat t he ef f ect s of wi nd l oad act i ng i nwar d and out war d nor mal t o t he pl ane of t he wal l ar e i n accor dance wi t h ASTM E330/ E330M.
d. Ther mal Loads And Movement :
( 1) Ambi ent Temper at ur e Range: 120 degr ees F
( 2) Mat er i al Sur f aces Range: 180 degr ees F
e. Wat er and Ai r Resi st ance: Pr ovi de weat her st r i ppi ng, ext er i or gasket s, seal ant s, and ot her accessor i es t o r esi st wat er and ai r penet r at i on.
f . I mpact - Pr ot ect i ve Syst ems Pr ovi de an i mpact - pr ot ect i ve syst em i n
SECTI ON 08 41 13 Page 6
Gallagher, Brad K.
Text Box
ADDENDUM #1 - 02/17/2025
Gallagher, Brad K.
Cloud
Gallagher, Brad K.
Cloud accor dance wi t h ASTM E1886.
2. 1. 1. 1 Mat er i al St andar d
ASTM B221; 6063- T5 al l oy and t emper ed.
Pr ovi de door st i l e and r ai l f ace di mensi ons of t he ent r ance door s as f ol l ows:
Ver t i cal St i l e Top Rai l Bot t om Rai l
3- 1/ 2 i nches 3- 1/ 2 i nches 6- 1/ 2 i nches
Pr ovi de maj or por t i ons of t he door member s at 0. 125 i nches nomi nal i n t hi ckness and gl azi ng mol di ng at 0. 050 i nches t hi ck.
2. 1. 1. 2 Recycl ed Cont ent
Pr ovi de al umi num f r amed ent r ances and st or ef r ont s t hat have a mi ni mum of 20 per cent r ecycl ed cont ent based upon t he al umi num bi l l et used i n t he or i gi nal mat er i al . Pr ovi de dat a i ndi cat i ng per cent age of r ecycl ed cont ent of al umi num mat er i al .
2. 1. 1. 3 Seal ant s
Pr ovi de ei t her et hyl ene pr opyl ene di ene monomer ( EPDM) el ast omer i c ext r usi ons or t her mopl ast i c el ast omer gl azi ng gasket s. St r uct ur al s i l i cone seal ant i s r equi r ed.
I nt er nal Seal ant s: Pr ovi de seal ant s t hat accor di ng t o t he manuf act ur er wi l l r emai n per manent l y el ast i c, t acky, non- dr yi ng, non- mi gr at i ng, and weat her t i ght .
2. 1. 1. 4 Ther mal Bar r i er
Use a r i gi d, st r uct ur al t her mal bar r i er t o separ at e al l ext er i or al umi num f r om i nt er i or al umi num. For pur poses of t hi s speci f i cat i on, a st r uct ur al t her mal bar r i er i s def i ned as a syst em t hat t r ansf er s shear dur i ng bendi ng and, t her ef or e, pr omot es composi t e act i on bet ween t he ext er i or and i nt er i or ext r usi ons. Do not use a nonst r uct ur al t her mal bar r i er . Ensur e t hat t he t her mal bar r i er pr ovi des a st r uct ur al connect i on bet ween t he t wo si des of t he door .
2. 2 FABRI CATI ON
Pr ovi de t he f ol l owi ng i nf or mat i on when submi t t i ng f abr i cat i on dr awi ngs f or cust om f abr i cat i ons:
a. I ndi cat e el evat i ons, det ai l ed desi gn, di mensi ons, member pr of i l es, j oi nt l ocat i ons, ar r angement of uni t s, and member connect i ons.
b. Show t he f ol l owi ng i t ems:
( 1) Det ai l s of speci al shapes.
( 2) Rei nf or ci ng.
( 3) Anchor age syst em.
SECTI ON 08 41 13 Page 7
( 4) I nt er f aci ng wi t h bui l di ng const r uct i on.
( 5) Pr ovi s i ons f or expansi on and cont r act i on.
( 6) Ther mal br eaks.
c. I ndi cat e t ypi cal gl azi ng det ai l s, l ocat i ons of var i ous t ypes and t hi ckness of gl ass and i nt er nal seal ant r equi r ement s as r ecommended by t he seal ant manuf act ur er .
d. Cl ear l y i ndi cat e l ocat i ons of exposed f ast ener s and j oi nt s.
e. Cl ear l y show wher e and how t he manuf act ur er ' s syst em devi at es f r om Cont r act dr awi ngs and t hese speci f i cat i ons.
2. 2. 1 Ent r ance Syst em Fabr i cat i on
Pr ovi de door cor ner const r uct i on consi st i ng of mechani cal c l i p f ast eni ng, SI GMA deep penet r at i on pl ug wel ds and 1- 1/ 8 i nch l ong f i l l et wel ds i nsi de and out si de al l f our cor ner s. Pr ovi de a hook- i n t ype ext er i or gl azi ng st op wi t h EPDM gl azi ng gasket s r ei nf or ced wi t h non- st r et chabl e cor d.
Pr ovi de an i nt er i or gl azi ng st op t hat i s mechani cal l y f ast ened t o t he door member and t hat i ncor por at es a s i l i cone- compat i bl e spacer used wi t h s i l i cone seal ant .
Accur at el y f i t and secur e j oi nt s and cor ner s. Make j oi nt s hai r l i ne i n appear ance. Remove bur r s and smoot h edges. Pr epar e component s wi t h i nt er nal r ei nf or cement f or door har dwar e. Ar r ange f ast ener s and at t achment s so t hat t hey ar e conceal ed f r om vi ew.
Separ at e di ssi mi l ar met al s wi t h pr ot ect i ve coat i ng or pr e- f or med separ at or s t o pr event cont act and cor r osi on.
2. 2. 2 Shop Assembl y
Fabr i cat e and assembl e uni t s wi t h j oi nt s onl y at t he i nt er sect i on of al umi num member s wi t h hai r l i ne j oi nt s; r i gi dl y secur e t hese uni t s, and seal t hem i n accor dance wi t h t he manuf act ur er ' s r ecommendat i ons.
2. 2. 2. 1 Wel di ng
Conceal wel ds on al umi num member s i n accor dance wi t h AWS r ecommendat i ons or met hods r ecommended by t he manuf act ur er . Member s showi ng wel di ng bl oom or di scol or at i on on f i ni sh or mat er i al di st or t i on wi l l be r ej ect ed by t he Cont act i ng Of f i cer .
2. 2. 3 Fi ni sh
Bef or e f abr i cat i on, c l ean t he uni t s and gi ve t hem a AA- M- 10- C22- A42 speci f i ed ( col or ) anodi zed f i ni sh i n accor dance wi t h t he r equi r ement s of t he AA DAF45. The f i ni sh t hi ckness i s A41, 0. 4 mi l or gr eat er .
a. Or gani c Coat i ng ( hi gh- per f or mance ext er i or coat i ng) :
( 1) Compl y wi t h r equi r ement s of AAMA 2605.
( 2) Cl ean sur f aces and pr et r eat t hem wi t h a conver si on coat i ng bef or e appl y i ng 0. 3 mi l dr y- f i l m t hi ckness of epoxy or acr yl i c pr i mer
SECTI ON 08 41 13 Page 8 accor di ng t o t he r ecommendat i ons of t he f i ni sh coat manuf act ur er .
( 3) Appl y a f i ni sh coat of 70 per cent mi ni mum f l uor opol ymer r esi n f used t o pr i med sur f aces at t he t emper at ur e r ecommended by t he manuf act ur er and at a mi ni mum dr y f i l m t hi ckness of 1. 0 mi l .
( 4) Use a 2- , 3- , or 4- coat syst em as r equi r ed f or t he col or sel ect ed.
2. 2. 4 Fabr i cat i on Tol er ance
Fabr i cat e and assembl e uni t s wi t h j oi nt s onl y at i nt er sect i on of al umi num member s wi t h hai r l i ne j oi nt s; r i gi dl y secur e t hese uni t s, and seal t hem i n accor dance wi t h t he manuf act ur er ' s r ecommendat i ons.
Fabr i cat e al umi num ent r ances i n accor dance wi t h t he ent r ance manuf act ur er ' s pr escr i bed t ol er ances.
2. 2. 4. 1 Mat er i al Cut s
Squar e t o 1/ 32 i nch of f squar e, over l ar gest di mensi on; pr opor t i onat e amount of 1/ 32 i nch on t he t wo di mensi ons.
2. 2. 4. 2 Maxi mum Of f set at Consecut i ve Member s
1/ 64 i nch i n al i gnment bet ween t wo consecut i ve member s i n l i ne, end t o end.
2. 2. 4. 3 Joi nt s
Bet ween adj acent member s i n same assembl y: Joi nt s ar e hai r l i ne and squar e t o t he adj acent member .
2. 2. 4. 4 Var i at i on
I n squar i ng di agonal s f or door s and f abr i cat ed assembl i es: 1/ 16 i nch.
2. 2. 4. 5 Fl at ness
For door s and f abr i cat ed assembl i es: pl us/ mi nus 1/ 16 i nch of neut r al pl ane.
2. 3 MATERI ALS
2. 3. 1 Seal ant s
Ref er t o Sect i on 07 92 00 JOI NT SEALANTS. Ensur e t hat al l seal ant s conf or m t o AAMA 800.
2. 3. 2 Gl ass
Ref er t o Sect i on 08 81 00 GLAZI NG.
2. 4 ACCESSORI ES
2. 4. 1 Fast ener s
Pr ovi de st ai nl ess st eel f ast ener s i n ar eas wher e t he f ast ener s ar e exposed.
Use non- cor r osi ve and compat i bl e f ast ener s wi t h component s bei ng f ast ened. Do not use exposed f ast ener s, except wher e unavoi dabl e f or
SECTI ON 08 41 13 Page 9 appl i cat i on of har dwar e.
I n ar eas wher e f ast ener s ar e not exposed, use al umi num, non- magnet i c st ai nl ess st eel , or ot her mat er i al s war r ant ed by t he manuf act ur er .
For exposed l ocat i ons, pr ovi de count er sunk Phi l l i ps head scr ews when i t ems wi t h a mat chi ng f i ni sh ar e f ast ened. For conceal ed l ocat i ons, pr ovi de t he manuf act ur er ' s st andar d f ast ener s.
Pr ovi de nut s or washer s t hat have been desi gned wi t h a means t o pr event di sengagement ; do not def or m f ast ener t hr eads.
2. 4. 2 Per i met er Anchor s
When st eel anchor s ar e used, pr ovi de i nsul at i on bet ween st eel mat er i al and al umi num mat er i al t o pr event gal vani c act i on.
2. 4. 2. 1 I nser t s and Anchor age Devi ces
Pr ovi de manuf act ur er ' s st andar d f or med or f abr i cat ed assembl i es, st eel or al umi num, of shapes, pl at es, bar s, or t ubes. Shop- coat st eel assembl i es af t er f abr i cat i on wi t h an al kyd zi nc chr omat e pr i mer compl yi ng wi t h
FS TT- P- 645.
2. 4. 3 St andar d Ent r ance Har dwar e
2. 4. 3. 1 Weat her st r i ppi ng
Equi p meet i ng st i l es on pai r s of door s wi t h an adj ust abl e ast r agal usi ng wool pi l e wi t h a pol ymer i c f i n.
Pr ovi de door weat her st r i ppi ng on a s i ngl e- act i ng of f set pi vot or but t - hung door and f r ame ( s i ngl e or pai r s) consi st i ng of a t her mopl ast i c el ast omer weat her st r i ppi ng on a t ubul ar shape wi t h a semi - r i gi d pol ymer i c backi ng.
Pr ovi de si l l - sweep st r i ps: Pr ovi de an EPDM bl ade gasket sweep st r i p i n an al umi num ext r usi on appl i ed t o t he i nt er i or exposed sur f ace of t he bot t om r ai l wi t h conceal ed f ast ener s. ( Pr ovi de as necessar y t o meet speci f i ed per f or mance t est s. )
2. 4. 3. 2 Thr eshol d
Pr ovi de an ext r uded al umi num t hr eshol d, per Sect i on 08 71 00 HARDWARE SCHEDULE one pi ece per door openi ng, wi t h r i bbed sur f ace.
2. 4. 3. 3 Pani c Devi ce
Pr ovi de t he manuf act ur er ' s r ecommended st andar d pani c har dwar e per Sect i on
08 71 00 HARDWARE SCHEDULE.
2. 4. 3. 4 Cl oser
Pr ovi de a sur f ace cl oser i n accor dance wi t h ANSI / BHMA A156. 4 and per sect i on 08 70 00 DOOR HARDWARE.
2. 4. 3. 5 Secur i t y Lock or Dead Lock
Pr ovi de l ocks per Sect i on 08 71 00 - DOOR HARDWARE .
SECTI ON 08 41 13 Page 10
2. 4. 3. 6 Cyl i nder ( s) / Thumb- t ur n
Pr ovi de cyl i nder s per Sect i on 08 71 00 - DOOR HARDWARE.
2. 4. 3. 7 Cyl i nder Guar d
Pr ovi de t he manuf act ur er ' s r ecommended st andar d.
PART 3 EXECUTI ON
3. 1 EXAMI NATI ON
3. 1. 1 Si t e Ver i f i cat i on of Condi t i ons
Ver i f y t hat t he condi t i on of subst r at e pr evi ousl y i nst al l ed under ot her sect i ons i s accept abl e f or pr oduct i nst al l at i on i n accor dance wi t h t he manuf act ur er ' s i nst r uct i ons.
Ver i f y t hat openi ngs ar e s i zed t o r ecei ve t he st or ef r ont syst em and t hat t he s i l l pl at e i s l evel i n accor dance wi t h t he manuf act ur er ' s accept abl e t ol er ances.
3. 2 PREPARATI ON
Fi el d- ver i f y di mensi ons bef or e f abr i cat i ng component s f or t he door por t al assembl y.
Coor di nat e r equi r ement s f or l ocat i ons of bl ockout s f or anchor age of door por t al col umns and ot her embedded component s wi t h Sect i on 03 30 00
CAST- I N- PLACE CONCRETE.
Coor di nat e t he er ect i on of door por t al wi t h i nst al l at i on of sur r oundi ng gl ass wal l and door assembl i es. Ensur e t hat t he door por t al s can pr ovi de suppor t and anchor age f or assembl y component s.
Coor di nat e el ect r i cal r equi r ement s f or el ect r i f i ed door har dwar e t o ensur e pr oper power sour ce, condui t , wi r i ng, and boxes.
3. 2. 1 Adj acent Sur f aces Pr ot ect i on
Pr ot ect adj acent wor k ar eas and f i ni sh sur f aces f r om damage dur i ng pr oduct i nst al l at i on.
3. 2. 2 Al umi num Sur f ace Pr ot ect i on
Pr ot ect al umi num sur f aces f r om cont act wi t h l i me, mor t ar , cement , aci ds, and ot her har mf ul cont ami nant s.
3. 3 I NSTALLATI ON
Wi ndows must conf or m t o AAMA/ WDMA/ CSA 101
I nst al l wi ndows/ st or ef r ont s accor di ng t o ASTM E2112.
Submi t i nst al l at i on dr awi ngs f or r evi ew and appr oval .
I nst al l t he ent r ance syst em i n accor dance wi t h t he manuf act ur er ' s i nst r uct i ons and t he AAMA st or ef r ont and ent r ance gui de speci f i cat i ons manual . At t ach t he ent r ance syst em t o t he st r uct ur e, al l owi ng i t t o be
SECTI ON 08 41 13 Page 11 adj ust ed t o accommodat e const r uct i on t ol er ances and ot her i r r egul ar i t i es.
Pr ovi de al i gnment at t achment s and shi ms t o per manent l y f ast en t he syst em t o t he bui l di ng st r uct ur e. Al i gn t he assembl y so t hat i t i s pl umb and l evel , and f r ee of war p and t wi st . Mai nt ai n assembl y di mensi onal t ol er ances al i gni ng wi t h adj acent wor k.
Set t hr eshol ds i n a bed of mast i c and secur e t he t hr eshol ds. Pr ot ect al umi num member s i n cont act wi t h masonr y, st eel , concr et e, or di ssi mi l ar mat er i al s usi ng nyl on pads or a bi t umi nous coat i ng. Shi m and br ace t he al umi num syst em bef or e anchor i ng t he syst em t o t he st r uct ur e. Ver i f y t hat weep hol es ar e open, and t he met al j oi nt s ar e seal ed i n accor dance wi t h t he manuf act ur er ' s i nst al l at i on i nst r uct i ons. Seal met al - t o- met al j oi nt s usi ng a seal ant r ecommended by t he syst em manuf act ur er .
3. 3. 1 Tol er ances
Ensur e t hat t ol er ances f or wal l t hi ckness and ot her cr oss- sect i onal di mensi ons of ent r ance member s ar e nomi nal and i n compl i ance wi t h Al umi num St andar ds and Dat a, publ i shed by t he Al umi num Associ at i on.
3. 3. 2 Adj ust i ng
Adj ust oper at i ng har dwar e f or smoot h oper at i on, and as r ecommended by t he manuf act ur er .
3. 3. 3 Rel at ed Pr oduct s I nst al l at i on Requi r ement s
3. 3. 3. 1 Seal ant s ( Per i met er )
Ref er t o Sect i on 07 92 00 JOI NT SEALANTS.
3. 3. 3. 2 Gl ass
Ref er t o Sect i on 08 81 00 GLAZI NG.
3. 4 FI ELD QUALI TY CONTROL
3. 4. 1 Ai r I nf i l t r at i on
Test ai r i nf i l t r at i on i n accor dance wi t h ASTM E783
Submi t cer t i f i ed t est r epor t s showi ng compl i ance wi t h speci f i ed per f or mance char act er i st i cs as f ol l ows:
a. For s i ngl e- act i ng of f set pi vot , but t hung, or cont i nuous gear ed hi nge ent r ances i n t he c l osed and l ocked posi t i on, t est t he speci men i n accor dance wi t h ANSI / BHMA A156. 10, and ASTM E283 at a pr essur e di f f er ent i al of 1. 57 psf f or pai r s of door s; ensur e t hat maxi mum i nf i l t r at i on f or a pai r of 7 f oot by 8 f oot ent r ance door s and f r ame i s
1. 2 cf m/ squar e f oot .
b. Ensur e t he maxi mum al l owabl e i nf i l t r at i on f or a compl et ed st or ef r ont syst em does not exceed 0. 06 cf m/ squar e f oot when t est ed i n accor dance wi t h ASTM E1424 at a di f f er ent i al st at i c pr essur e of 6. 24 psf .
3. 4. 2 Wi nd Loads
Pr ovi de a compl et ed st or ef r ont syst em capabl e of wi t hst andi ng wi nd pr essur e l oads, nor mal t o t he wal l pl ane i ndi cat ed, as f ol l ows:
SECTI ON 08 41 13 Page 12
a. Ext er i or Wal l s
( 1) Posi t i ve Pr essur e: psf
( 2) Negat i ve Pr essur e: psf
b. I nt er i or Wal l s: ( pr essur e act i ng i n ei t her di r ect i on) 5 psf
3. 4. 3 Def l ect i on
Submi t cer t i f i ed t est r epor t s showi ng t hat t he maxi mum al l owabl e def l ect i on i n a member when t est ed i n accor dance wi t h ASTM E330/ E330M wi t h al l owabl e st r ess i s L/ 175 or 3/ 4 i nches maxi mum.
3. 4. 4 Condensat i on Resi st ance and Ther mal Tr ansmi t t ance
Submi t cer t i f i ed t est r epor t s showi ng compl i ance wi t h speci f i ed per f or mance char act er i st i cs as f ol l ows:
a. U- Val ue Requi r ement s:
( 1) Per f or m t est i n accor dance wi t h t he AAMA 1503 pr ocedur e and on t he conf i gur at i on speci f i ed t her ei n.
( 2) Ther mal Tr ansmi t t ance ( " U" Val ue) maxi mum 0. 65 ( 6250) BTU/ hr / sf / deg F at 15 mph ext er i or wi nd.
b. CRF Cl ass Requi r ement s:
( 1) Per f or m a t est i n accor dance wi t h AAMA 1503.
3. 4. 5 Wat er I nf i l t r at i on
Submi t cer t i f i ed t est r epor t s showi ng t hat t he syst em i s desi gned t o pr ovi de no uncont r ol l ed wat er when t est ed i n accor dance wi t h ASTM E1105 at a st at i c pr essur e of 8 psf .
3. 5 ADJUSTI NG AND CLEANI NG
3. 5. 1 Pr ot ect i on
Pr ot ect t he i nst al l ed pr oduct ' s f i ni sh sur f aces f r om damage dur i ng const r uct i on. Pr ot ect t he al umi num st or ef r ont syst em f r om damage f r om gr i ndi ng and pol i shi ng compounds, pl ast er , l i me, aci d, cement , or ot her har mf ul cont ami nant s.
3. 5. 2 Cl eani ng
Repai r or r epl ace damaged i nst al l ed pr oduct s. Cl ean i nst al l ed pr oduct s i n accor dance wi t h manuf act ur er ' s i nst r uct i ons bef or e accept ance r emove excess mast i c, mast i c smear s, and ot her f or ei gn mat er i al s. Remove const r uct i on debr i s f r om t he pr oj ect s i t e and l egal l y di spose of t hi s debr i s.
SECTI ON 08 41 13 Page 13
3. 6 WARRANTY
Submi t t hr ee si gned copi es of t he manuf act ur er ' s pr oduct war r ant y f or t he ent r ance syst em as f ol l ows:
a. War r ant y Per i od: Fi ve year s f r om Dat e of Subst ant i al Compl et i on of t he pr oj ect , pr ovi ded t hat t he Li mi t ed War r ant y begi ns no l at er t han si x mont hs f r om t he dat e of shi pment by t he manuf act ur er . I n addi t i on, suppor t wel ded door cor ner const r uct i on wi t h a l i mi t ed l i f et i me war r ant y f or t he l i f e of t he door under nor mal use.
Ensur e t hat t he War r ant y ' s l anguage i s i dent i cal t o t he " As Appr oved" ver si on of t he sampl e war r ant y submi t t ed t o and r et ur ned f r om t he Cont r act i ng Of f i cer .
- - End of Sect i on - -
SECTI ON 08 41 13 Page 14
| 08 41 13 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 ADMINISTRATIVE REQUIREMENTS |
| 1.2.1 Pre-Installation Meetings |
| 1.3 SUBMITTALS |
| 1.4 QUALITY CONTROL |
| 1.4.1 Qualifications |
| 1.4.1.1 Installer Qualifications |
| 1.4.1.2 Manufacturer Qualifications |
1.4.2 Single-Source Responsibility
| 1.5 DELIVERY, STORAGE, AND HANDLING |
| 1.5.1 Ordering |
| 1.5.2 Packing, Shipping, Handling and Unloading |
| 1.5.3 Storage and Protection |
| 1.6 PROJECT / SITE CONDITIONS |
| 1.6.1 Field Measurements |
1.7 WARRANTY
| PART 2 PRODUCTS |
| 2.1 SYSTEM DESCRIPTION |
| 2.1.1 Design Requirements for Aluminum Entrances and Components |
| 2.1.1.1 Material Standard |
| 2.1.1.2 Recycled Content |
| 2.1.1.3 Sealants |
| 2.1.1.4 Thermal Barrier |
| 2.2 FABRICATION |
| 2.2.1 Entrance System Fabrication |
| 2.2.2 Shop Assembly |
| 2.2.2.1 Welding |
| 2.2.3 Finish |
| 2.2.4 Fabrication Tolerance |
| 2.2.4.1 Material Cuts |
| 2.2.4.2 Maximum Offset at Consecutive Members |
| 2.2.4.3 Joints |
| 2.2.4.4 Variation |
| 2.2.4.5 Flatness |
| 2.3 MATERIALS |
| 2.3.1 Sealants |
| 2.3.2 Glass |
| 2.4 ACCESSORIES |
| 2.4.1 Fasteners |
| 2.4.2 Perimeter Anchors |
| 2.4.2.1 Inserts and Anchorage Devices |
| 2.4.3 Standard Entrance Hardware |
| 2.4.3.1 Weatherstripping |
| 2.4.3.2 Threshold |
| 2.4.3.3 Panic Device |
| 2.4.3.4 Closer |
| 2.4.3.5 Security Lock or Dead Lock |
| 2.4.3.6 CylindersThumb-turn |
| 2.4.3.7 Cylinder Guard |
| PART 3 EXECUTION |
| 3.1 EXAMINATION |
| 3.1.1 Site Verification of Conditions |
| 3.2 PREPARATION |
| 3.2.1 Adjacent Surfaces Protection |
| 3.2.2 Aluminum Surface Protection |
| 3.3 INSTALLATION |
| 3.3.1 Tolerances |
| 3.3.2 Adjusting |
| 3.3.3 Related Products Installation Requirements |
| 3.3.3.1 Sealants Perimeter |
| 3.3.3.2 Glass |
| 3.4 FIELD QUALITY CONTROL |
| 3.4.1 Air Infiltration |
| 3.4.2 Wind Loads |
| 3.4.3 Deflection |
| 3.4.4 Condensation Resistance and Thermal Transmittance |
| 3.4.5 Water Infiltration |
| 3.5 ADJUSTING AND CLEANING |
| 3.5.1 Protection |
| 3.5.2 Cleaning |
3.6 WARRANTY
File details come from the government source that posted it. Updated .