AE151 - REFLECTED CEILING PLAN - SECTOR A.pdf
PDF 602 KB Posted
- Solicitation number
- W50S8T25BA011
- Issued by
-
Department of the Army National Guard
About this file
This is a reflected ceiling plan drawing (Sheet AE151) for Sector A of Building 1040 at Will Rogers Air National Guard Base in Oklahoma City. The drawing shows a detailed layout of ceiling elements including 2'x2' ceiling grid, gypsum board ceiling, lighting fixtures (2'x4', 2'x2', emergency fixtures, exit signs), supply air diffusers, return air grilles, and access doors.
The plan indicates ceiling heights of 8'-0" throughout unless otherwise noted, with specific details for mechanical equipment areas and exterior soffit systems. Key features include demolition of existing soffit panels for new exterior wall construction, coordination requirements for mechanical/electrical/communications systems above the ceiling, and specific notes regarding shower ceiling materials and access panel locations. The drawing includes both a main floor plan at 1/8"=1'-0" scale and a detail drawing at 3/4"=1'-0" scale showing furr-down construction at exterior walls. This drawing is part of a larger renovation project dated September 12, 2024, with an addendum issued February 17, 2025.
View the file
Other files
Show all 50
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T
T
T
T
A B C
D
D
E
E
F
F
G
4a
5a
6a
7a
8a
9a
10a
11a
A'
B'
C'
D'
AE301
D1
AE301
D1
OPS CHF.
FRAME
CP MGR.
OFF/TRAIN.
CORR.
WOMEN
VEST.
BREAK RM
OPER TEAM
CLIENT SVC
CTR.
BREAK RM
T&T
CMDR
DATA CENTER
VAULT
TEL/SWITCH
MISSION DEF
TEAM (S.O.S.)
P&R CHIEF
PRINT SUPPLY
CORR
VEST
MECH
FIRE
RISER/FACP
123 VEST
RADIO SHOP
ITE
CORR
VEST
VEST
OFFICE
DATA
1ST SGT
M
AT
C H
LI
N
E
SE
E A
AE
M
AT
C H
LI
N
E
SE
E A
AE
10'-0"
AE152
D4
AE301
A2
AE151
A4
5 1/8" 2'-2"
3' -0
2' -2
SHOWER
120.1
ELEC
MULTI-USE
174B
UNISEX
ELEC.
126.1
AE301
A4
4 4
DEMO EXISTING SOFFIT PANELS AS
REQUIRED FOR NEW EXTERIOR WALL.
CONTRACTOR TO INSPECT AND
COORDINATE SUPPORTS FOR EXISTING
SOFFIT OR THEIR REMOVAL. SEE DETAIL
A4/AE301
P&R
OPEN OFFICE
GENERAL NOTES
A. ALL CEILINGS ARE 8'-0" A.F.F. UNLESS
OTHERWISE NOTED.
B. CONTRACTOR IS RESPONSIBLE FOR THE
COORDINATION OF MECHANICAL, FIRE
SUPPRESSION, ELECTRICAL, COMMUNICATIONS,
AND OTHER SYSTEMS ABOVE THE CEILING AND
SHALL VERIFY THE ACCOMMODATION OF THESE
SYSTEM WITHIN THE SPACE INDICATED ON THE
DRAWINGS BEFORE PROCEEDING WITH THE
WORK. NOTIFY THE CONTRACTING OFFICER
IMMEDIATELY IF ANY DISCREPANCIES OR
CONFLICTS ARE DISCOVERED WHERE INDICATED
CEILING HEIGHTS CANNOT BE MAINTAINED.
C. CENTER ALL LIGHTS FIXTURES, SPRINKLER
HEADS, SPEAKERS, AND DETECTORS WITHIN
CEILING ELEMENTS UNLESS INDICATED
OTHERWISE.
D. COORDINATE ACCESS PANEL LOCATIONS WITH
OTHER CEILING MOUNTED ACCESSORIES.
E. PROVIDE HOLD DOWN CLIPS IN A 100 SF AREA AT
ACOUSTICAL PANEL CEILINGS ADJACENT TO
EXTERIOR DOORS.
F. REFER ROOM FINISH SCHEDULE FOR CEILING
HEIGHTS IF NOT SHOWN ON PLAN AND SPECIFICS
ON MATERIALS NOTED IN THE REFLECTED
CEILING PLAN LEGEND.
G. REFER ELECTRICAL FOR LIGHTING FIXTURE
SCHEDULE.
H. SHOWER CEILINGS TO BE GLAS-MAT GYP. BD.
FINISH WITH EPOXY PAINT. - VERIFY CEILING
HEIGHT WITH SHOWER INSERT MANUFACTURER
PRIOR TO FRAMING AND FINISH.
STANDARD PARTITION - NEW WALL
BATT INSULATION - NEW WALL
EXISTING PARTITION (NOT DEMO'D)
FLOOR PLAN LEGEND
CJ DENOTES LOCATION OF DRYWALL
CONTROL JOINT
EXISTING ACCESS FLOOR SYSTEM
SECURE BOUNDARY
TYPICAL CEILING LEGEND
2' x 2' CEILING GRID
GYP BD CEILING
2' x 4' FIXTURE - EMERGENCY
EXIT SIGNS
SUPPLY AIR DIFFUSERS
RETURN AIR GRILLES
ACCESS DOORS
2' x 4' FIXTURE
2' x 2' FIXTURE
2' x 2' FIXTURE - EMERGENCY
1' x 4' SUSPENDED FIXTURE
RECESSED CAN LIGHT AND EMER FIXTURE
SHEET KEYNOTES
1. OPEN TO STRUCTURE
2. MECHANICAL EQUIPMENT
3. EXISTING EXTERIOR SOFFIT SYSTEM TO REMAIN
4. REPLACE EXTERIOR RECESSED CANNED DOWN
LIGHT - RE: ELECTRICAL
5. 8"x8" CEILING ACCESS PANEL
6. CEILING AND LIGHT FIXTURES TO BE REPLACED
CONCURRENT WITH WORK ON FIRE SUPPRESSION
SYSTEM IN THIS AREA.
6a
8'-0"
BRACE TO
STRUCTURE AS
REQUIRED
EXISTING STEEL
BEAM - VERIFY
LOCATION
CEILING AS
SCHEDULED
5/8" GYP BD -
BOTH SIDES
6"
3-5/8" CFMF @
16" OC
EXISTING ROOF
CONSTRUCTION
2"
CONTINUE
FRAMING TO DECK
IF NO STRUCTURE
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
Frankfurt-Short-Bruza Associates,P.C.
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
2020-484-00
NDM
Re pa ir/ Co nv er t S qu ad O ps Ok lah om a C ity
, O K
NG
BJ
V/
OK
A
NG
PN: YZEU142025
C :\U sers\bkg\D o cum ents\M y R evit\048400_AR C
H
_BG
allagher5SB23.rvt
2/14/2025 8:31: 07 AM
12 SEPTEMBER 2024
REFLECTED CEILING PLAN -
SECTOR A
AE151
MJT
MRT
JO
SCALE: 1/8" = 1'-0"
REFLECTED CEILING PLAN - SECTOR AA1
0 4' 8' 16'
1/8" = 1'-0"
N
PROJECT
KEYPLANN
A B
SCALE: 3/4" = 1'-0"
DETAIL @ FURR-DOWNA4
1' 3'2'0
3/4" = 1'-0"
2 ADDENDUM 01 02/17/2025
File details come from the government source that posted it. Updated .