This is a technical specification (Section 08 81 00) for glazing work as part of the Building 1040 renovation project at the 137th SOW Oklahoma Air National Guard Base. The specification details requirements for various types of glass and glazing materials including clear glass, laminated glass, tempered glass, insulating glass units, and fire/safety rated glass, along with associated setting materials, sealants, and accessories.

The document provides comprehensive installation requirements, including environmental conditions (work must occur above 40°F), warranty terms (10-year warranty required for insulating glass units), and specific performance criteria such as Solar Heat Gain Coefficient maximum of 0.32 and Winter Nighttime U-factor maximum of 0.29 Btu/sq ft/hr/°F. Notable requirements include providing watertight and airtight glazing systems that can withstand thermal movement and wind loading, compliance with ANSI Z97.1 safety standards, and special provisions for one-way vision glazing using dual reflective high performance window film in certain areas. The specification includes detailed requirements for product submittals, quality control measures, cleaning procedures, and protection of installed glazing.

View the file

Other files

File Type Posted
Abstract (Final).pdf PDF
Amendment 3 Attachment 1 - Bldg 1040 Reno Questions and Answers.docx DOCX document
Solicitation Amendment 3 W50S8T25BA0110003.pdf PDF
NEW 6 Mar 25 Oklahoma NGB-WRWA - 100 CD Set Part 1.pdf PDF
NEW 6 Mar 25 Oklahoma NGB-WRWA - 100 CD Set Part 2.pdf PDF
Amendment 2 Attachment 2 - 09 72 00.pdf PDF
Amendment 2 Attachment 5 - IN600 - INTERIORS MATERIALS LEGEND.pdf PDF
Amendment 2 Attachment 3 - A-002 - PARTITION TYPES.pdf PDF
Amendment 2 Attachment 6 - Bldg 1040 Reno Questions and Answers.xlsx XLSX spreadsheet
Amendment 2 Attachment 1 - Addendum 02 Narrative.docx DOCX document
Solicitation Amendment 2 W50S8T25BA0110002.pdf PDF
Amendment 2 Attachment 4 - 08 11 16.pdf PDF
06 20 00.pdf PDF
21 13 13.pdf PDF
IN101 - FLOOR FINISH PLAN - SECTOR A.pdf PDF
Bldg 1040 Reno Questions and Answers - FSB and GOV Reponses.xlsx XLSX spreadsheet
EL101 - ELECTRICAL INTERIOR LIGHTING PLAN - SECTOR A.pdf PDF
AE102 - FLOOR PLAN - SECTOR A.pdf PDF
AE502 - DETAILS.pdf PDF
AE403 - ENLARGED PLANS.pdf PDF
10 21 13.pdf PDF
10 51 13.pdf PDF
08 41 13.pdf PDF
AE103 - FLOOR PLAN - SECTOR B.pdf PDF
AE411 - INTERIOR ELEVATIONS.pdf PDF
AE402 - ENLARGED PLANS.pdf PDF
AE601 - DOOR SCHEDULE AND DETAILS.pdf PDF
26 05 73.pdf PDF
08 11 16.pdf PDF
AE602 - OLI 1 - EXTERIOR WINDOW FRAMES.pdf PDF
Addendum 01 Narrative.docx DOCX document
08 71 00.pdf PDF
IN102 - FLOOR FINISH PLAN - SECTOR B.pdf PDF
Solicitation Amendment 1 W50S8T25BA0110001 SF 30.pdf PDF
06 41 16.00 10.pdf PDF
AE201 - BUILDING ELEVATIONS.pdf PDF
TABLE OF CONTENTS.pdf PDF
A-002 - PARTITION TYPES.pdf PDF
01 45 35.pdf PDF
FA601 - FIRE ALARM - MASS NOTIFICATION RISER DIAGRAM.pdf PDF
AE151 - REFLECTED CEILING PLAN - SECTOR A.pdf PDF
AE600 - ROOM FINISH SCHEDULE.pdf PDF
10 51 16.pdf PDF
30 Jan 25 Site Visit Sign In Sheet.pdf PDF
BLDG 1040 Renovation Site Visit Slides 30 January 25.pptx PPTX presentation
ATTACHMENT 3 - 2024.09.12_OK-ANG_SQUADOPS B1040_TYPE B3_SPECIFICATIONS VOL. 2.pdf PDF
Solicitation - W50S8T25BA011.pdf PDF
ATTACHMENT 2 - 2024.09.12_OK-ANG_SQUADOPS B1040_TYPE B3_SPECIFICATIONS VOL. 1.pdf PDF
Bidders Checklist.docx DOCX document
ATTACHMENT 1 - 2024.09.12_OK-ANG_SQUADOPS B1040_TYPE B3_DRAWINGS.pdf PDF
Show all 50

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

137TH SOW OKLAHOMA ANG B- 3 100% REPAI R BUI LDI NG 1040

OKLAHOMA CI TY, OK 12 SEPTEMBER, 2024

SECTI ON 08 81 00

GLAZI NG

05/ 19

PART 1 GENERAL

1. 1 REFERENCES

The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.

AMERI CAN NATI ONAL STANDARDS I NSTI TUTE ( ANSI )

ANSI Z97. 1 ( 2015) Saf et y Gl azi ng Mat er i al s Used i n Bui l di ngs - Saf et y Per f or mance Speci f i cat i ons and Met hods of Test

ASTM I NTERNATI ONAL ( ASTM)

ASTM C509 ( 2006; R 2021) St andar d Speci f i cat i on f or El ast omer i c Cel l ul ar Pr ef or med Gasket and Seal i ng Mat er i al

ASTM C864 ( 2005; R 2015) Dense El ast omer i c Compr essi on Seal Gasket s, Set t i ng Bl ocks, and Spacer s

ASTM C920 ( 2018) St andar d Speci f i cat i on f or El ast omer i c Joi nt Seal ant s

ASTM C1021 ( 2008; R 2014) St andar d Pr act i ce f or Labor at or i es Engaged i n Test i ng of Bui l di ng Seal ant s

ASTM C1036 ( 2021) St andar d Speci f i cat i on f or Fl at Gl ass

ASTM C1048 ( 2018) St andar d Speci f i cat i on f or Heat - St r engt hened and Ful l y Temper ed Fl at Gl ass

ASTM C1087 ( 2016) St andar d Test Met hod f or Det er mi ni ng Compat i bi l i t y of Li qui d- Appl i ed Seal ant s wi t h Accessor i es Used i n St r uct ur al Gl azi ng Syst ems

ASTM C1172 ( 2019) St andar d Speci f i cat i on f or Lami nat ed Ar chi t ect ur al Fl at Gl ass

ASTM C1184 ( 2014) St andar d Speci f i cat i on f or St r uct ur al Si l i cone Seal ant s

ASTM D395 ( 2016; E 2017) St andar d Test Met hods f or Rubber Pr oper t y - Compr essi on Set

ASTM D2287 ( 2019) Nonr i gi d Vi nyl Chl or i de Pol ymer and

SECTI ON 08 81 00 Page 1

Gallagher, Brad K.

Cloud

Gallagher, Brad K.

Text Box

ADDENDUM #1 02-17-2025

Copol ymer Mol di ng and Ext r usi on Compounds

ASTM E1300 ( 2016) St andar d Pr act i ce f or Det er mi ni ng Load Resi st ance of Gl ass i n Bui l di ngs

ASTM E2190 ( 2010) St andar d Speci f i cat i on f or I nsul at i ng Gl ass Uni t Per f or mance and Eval uat i on

GLASS ASSOCI ATI ON OF NORTH AMERI CA ( GANA)

GANA Gl azi ng Manual ( 2008) Gl azi ng Manual

GANA Seal ant Manual ( 2008) Seal ant Manual

GANA St andar ds Manual ( 2008) Engi neer i ng St andar ds Manual

I NSULATI NG GLASS MANUFACTURERS ALLI ANCE ( I GMA)

I GMA TB- 1200 ( 1983; R 2016) Gui del i nes f or I nsul at i ng Gl ass Di mensi onal Tol er ances

I GMA TB- 3001 ( 2001) Gui del i nes f or Sl oped Gl azi ng

I GMA TM- 3000 ( 1990; R 2016) Nor t h Amer i can Gl azi ng Gui del i nes f or Seal ed I nsul at i ng Gl ass Uni t s f or Commer ci al & Resi dent i al Use

NATI ONAL FENESTRATI ON RATI NG COUNCI L ( NFRC)

NFRC 100 ( 2020) Pr ocedur e f or Det er mi ni ng Fenest r at i on Pr oduct U- Fact or s

NFRC 200 ( 2020) Pr ocedur e f or Det er mi ni ng Fenest r at i on Pr oduct Sol ar Heat Gai n Coef f i c i ent and Vi s i bl e Tr ansmi t t ance at Nor mal I nci dence

NATI ONAL FI RE PROTECTI ON ASSOCI ATI ON ( NFPA)

NFPA 252 ( 2022) St andar d Met hods of Fi r e Test s of Door Assembl i es

NFPA 257 ( 2022) St andar d on Fi r e Test f or Wi ndow and Gl ass Bl ock Assembl i es

U. S. NATI ONAL ARCHI VES AND RECORDS ADMI NI STRATI ON ( NARA)

16 CFR 1201 Saf et y St andar d f or Ar chi t ect ur al Gl azi ng Mat er i al s

1. 2 SUBMI TTALS

Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" or " S" c l assi f i cat i on. Submi t t al s not havi ng a " G" or " S" c l assi f i cat i on ar e f or Cont r act or Qual i t y Cont r ol appr oval . Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00 SUBMI TTAL PROCEDURES:

SECTI ON 08 81 00 Page 2

SD- 03 Pr oduct Dat a

I nsul at i ng Gl ass

Gl azi ng Accessor i es

Seal ant s

SD- 04 Sampl es

I nsul at i ng Gl ass

Gl azi ng Compound

Gl azi ng Tape

Seal i ng Tapes

SD- 07 Cer t i f i cat es

I nsul at i ng Gl ass

SD- 08 Manuf act ur er ' s I nst r uct i ons

Set t i ng and Seal i ng Mat er i al s

Gl ass Set t i ng

SD- 11 Cl oseout Submi t t al s

War r ant y f or I nsul at ed Gl ass Uni t s

1. 3 SYSTEM DESCRI PTI ON

Fabr i cat e and i nst al l wat er t i ght and ai r t i ght gl azi ng syst ems t o wi t hst and t her mal movement and wi nd l oadi ng wi t hout gl ass br eakage, gasket f ai l ur e, det er i or at i on of gl azi ng accessor i es, or def ect s i n t he wor k. Gl azed panel s must compl y wi t h t he saf et y st andar ds, i n accor dance wi t h ANSI Z97. 1, and compl y wi t h i ndi cat ed wi nd/ snow l oadi ng i n accor dance wi t h ASTM E1300.

1. 4 QUALI TY CONTROL

Submi t t wo 8 by 10 i nch sampl es of each of t he f ol l owi ng: t i nt ed gl ass, pat t er ned gl ass, heat - absor bi ng gl ass, and i nsul at i ng gl ass uni t s.

Submi t t hr ee sampl es of each ot her mat er i al . Sampl es of pl ast i c sheet s must be mi ni mum 5 by 7 i nches.

1. 5 DELI VERY, STORAGE, AND HANDLI NG

Del i ver pr oduct s t o t he s i t e i n unopened cont ai ner s, l abel ed pl ai nl y wi t h manuf act ur er s ' names and br ands. St or e gl ass and set t i ng mat er i al s i n saf e, encl osed dr y l ocat i ons and do not unpack unt i l needed f or i nst al l at i on. Handl e and i nst al l mat er i al s i n a manner t hat wi l l pr ot ect

SECTI ON 08 81 00 Page 3 t hem f r om damage.

1. 6 ENVI RONMENTAL REQUI REMENTS

Do not st ar t gl azi ng wor k unt i l t he out door t emper at ur e i s above 40 degr ees F and r i s i ng, unl ess pr ocedur es r ecommended by t he gl ass manuf act ur er and appr oved by t he Cont r act i ng Of f i cer ar e made t o war m t he gl ass and r abbet sur f aces. Pr ovi de vent i l at i on t o pr event condensat i on of moi st ur e on gl azi ng wor k dur i ng i nst al l at i on. Do not per f or m gl azi ng wor k dur i ng damp or r ai ny weat her .

1. 7 WARRANTY

1. 7. 1 War r ant y f or I nsul at ed Gl ass Uni t s

War r ant y i nsul at i ng gl ass uni t s agai nst devel opment of mat er i al obst r uct i on t o v i s i on ( such as dust , f oggi ng, or f i l m f or mat i on on t he i nner gl ass sur f aces) caused by f ai l ur e of t he her met i c seal , ot her t han t hr ough gl ass br eakage, f or a 10- year per i od f ol l owi ng accept ance of t he wor k. Pr ovi de new uni t s f or any uni t s f ai l i ng t o compl y wi t h t er ms of t hi s war r ant y wi t hi n 45 wor ki ng days af t er r ecei pt of not i ce f r om t he Gover nment .

PART 2 PRODUCTS

2. 1 GLASS

ASTM C1036, unl ess speci f i ed ot her wi se. I n door s and si del i ght s, pr ovi de saf et y gl azi ng mat er i al conf or mi ng t o 16 CFR 1201.

2. 1. 1 Cl ear Gl ass

For i nt er i or gl azi ng ( i . e. , pass and obser vat i on wi ndows) , 1/ 4 i nch t hi ck gl ass shoul d be used.

Type I , Cl ass 1 ( c l ear ) , Qual i t y q3 ( A) . Pr ovi de f or gl azi ng openi ngs not i ndi cat ed or speci f i ed ot her wi se. Use doubl e- st r engt h sheet gl ass or 1/ 8 i nch f l oat gl ass f or openi ngs up t o and i ncl udi ng 15 squar e f eet , 3/ 16 i nch f or gl azi ng openi ngs over 15 squar e f eet but not over 30 squar e f eet , and 1/ 4 i nch f or gl azi ng openi ngs over 30 squar e f eet but not over 45 squar e f eet .

For i nt er i or one- way vi s i on gl azi ng use a dual r ef l ect i ve hi gh per f or mance one- way mi r r or r ef l ect i ve wi ndow f i l m. Fi l m shoul d gi ve a t r ue one- way ef f ect wi t h no si l ver r ef l ect i on f r om t he i nsi de ( CAT Room 132) and no i nt er nal r ef l ect i on.

2. 1. 2 Anneal ed Gl ass

Anneal ed gl ass must be Type I t r anspar ent f l at t ype, Cl ass 1 - c l ear , Qual i t y q3 - gl azi ng sel ect , per cent l i ght t r ansmi t t ance, per cent shadi ng coef f i c i ent , conf or mi ng t o ASTM C1036.

2. 1. 3 Lami nat ed Gl ass

ASTM C1172, Lami nat ed gl ass f abr i cat ed f r om t wo nomi nal 1/ 8 i nch pi eces of Type I , Cl ass 1, Qual i t y Q3. c l ear gl ass conf or mi ng t o ASTM C1036. Fl at gl ass t o be l ami nat ed t oget her wi t h a mi ni mum of 0. 060 i nch t hi ck, c l ear pol yvi nyl but yr al l ami nat e, conf or mi ng t o r equi r ement s of 16 CFR 1201 and

SECTI ON 08 81 00 Page 4

Gallagher, Brad K.

Text Box

ADDENDUM #1 02-17-2025

Gallagher, Brad K.

Cloud

Gallagher, Brad K.

Cloud

ASTM C1172. The t ot al t hi ckness of nomi nal l y 1/ 4 i nches. Col or t o be cl ear .

2. 1. 4 Temper ed Gl ass

ASTM C1048, Ki nd FT ( f ul l y t emper ed) , Condi t i on A ( uncoat ed) , Type I , Cl ass 1 ( t r anspar ent ) , Qual i t y q3, 1/ 4" i nch t hi ck, conf or mi ng t o ASTM C1048 and GANA St andar ds Manual . Col or must be cl ear . Pr ovi de at ext er i or st or ef r ont syst em, and wher ever saf et y gl azi ng mat er i al i s i ndi cat ed or speci f i ed.

2. 1. 5 Fi r e/ Saf et y Rat ed Gl ass

2. 1. 5. 1 Fi r e Pr ot ect i on Rat ed Gl ass

Cl ear t emper ed and meet 16 CFR 1201 Cat egor y I ( under 9 squar e f eet ) or I I ( over 9 squar e f eet ) i mpact saf et y st andar d. Gl ass t o make 45 mi nut e r at i ng when t est ed i n accor dance wi t h NFPA 257 and NFPA 252. Gl ass t o be per manent l y l abel ed wi t h appr opr i at e mar ki ngs.

2. 2 I NSULATI NG GLASS UNI TS

Two panes of gl ass separ at ed by a dehydr at ed ai r space and her met i cal l y seal ed, conf or mi ng t o ASTM E2190. Submi t per f or mance and compl i ance document at i on f or each t ype of i nsul at i ng gl ass.

I nsul at ed gl ass uni t s must have a Sol ar Heat Gai n Coef f i c i ent ( SHGC) maxi mum of 0. 32 det er mi ned accor di ng t o NFRC 200, a 61 vi s i abl e l i ght t r ansmi t t ance, and a Wi nt er Ni ght t i me U- f act or maxi mum of 0. 29 Bt u per squar e f oot by hr by degr ee F i n accor dance wi t h NFRC 100.

Di mensi onal t ol er ances must be as speci f i ed i n I GMA TB- 1200. Spacer must be bl ack, r ol l - f or med, t her mal l y br oken al umi num , wi t h bent or t i ght l y wel ded or keyed and seal ed j oi nt s t o compl et el y seal t he spacer per i pher y and el i mi nat e moi st ur e and hydr ocar bon vapor t r ansmi ssi on i nt o ai r space t hr ough t he cor ner s. Pr i mar y seal must be compr essed pol y i sobut yl ene and t he secondar y seal must be a speci al l y f or mul at ed si l i cone.

The i nner pane must be l ami nat ed gl assASTM C1172. The out er pane must be t emper ed gl ass.

For ext er i or one- way vi s i on gl azi ng use a dual r ef l ect i ve hi gh per f or mance one- way mi r r or r ef l ect i ve wi ndow f i l m. Fi l m shoul d gi ve a t r ue one- way ef f ect wi t h no si l ver r ef l ect i on f r om t he i nsi de and no i nt er nal r ef l ect i on. Fi l m shoul d al l ow 10% vi s i bl e l i ght .

2. 3 SETTI NG AND SEALI NG MATERI ALS

Pr ovi de as speci f i ed i n t he GANA Gl azi ng Manual , I GMA TM- 3000, I GMA TB- 3001, and manuf act ur er ' s r ecommendat i ons, unl ess speci f i ed ot her wi se her ei n. Do not use met al sash put t y, nonski nni ng compounds, nonr esi l i ent pr ef or med seal er s, or i mpr egnat ed pr ef or med gasket s. Mat er i al s exposed t o v i ew and unpai nt ed must be gr ay or neut r al col or . Seal ant t est i ng must be per f or med by a t est i ng agency qual i f i ed accor di ng t o ASTM C1021.

Submi t gl ass manuf act ur er ' s r ecommendat i ons f or set t i ng and seal i ng mat er i al s and f or i nst al l at i on of each t ype of gl azi ng mat er i al speci f i ed.

2. 3. 1 Put t y and Gl azi ng Compound

Pr ovi de gl azi ng compound as r ecommended by manuf act ur er f or f ace- gl azi ng

SECTI ON 08 81 00 Page 5

Gallagher, Brad K.

Text Box

ADDENDUM #1 02-17-2025

Gallagher, Brad K.

Cloud

Gallagher, Brad K.

Cloud met al sash. Put t y must be l i nseed oi l t ype. Do not use put t y and gl azi ng compounds wi t h i nsul at i ng gl ass or l ami nat ed gl ass.

2. 3. 2 Gl azi ng Compound

Use f or f ace gl azi ng met al sash. Do not use wi t h i nsul at i ng gl ass uni t s or l ami nat ed gl ass.

2. 3. 3 Seal ant s

Pr ovi de el ast omer i c seal ant s.

2. 3. 3. 1 El ast omer i c Seal ant

ASTM C920, Type S, Gr ade NS, Cl ass 12. 5, Use G. Use f or channel or st op gl azi ng met al sash. Seal ant s must be chemi cal l y compat i bl e wi t h set t i ng bl ocks, edge bl ocks, and seal i ng t apes. Col or of seal ant must be whi t e.

2. 3. 3. 2 St r uct ur al Seal ant

ASTM C1184, Type S.

2. 3. 4 Seal i ng Tapes

Pr ef or med, semi sol i d, PVC- based mat er i al of pr oper s i ze and compr essi bi l i t y f or t he par t i cul ar condi t i on, compl yi ng wi t h ASTM D2287.

Use onl y wher e gl azi ng r abbet i s desi gned f or t ape and t ape i s r ecommended by t he gl ass or seal ant manuf act ur er . Pr ovi de spacer shi ms f or use wi t h compr essi bl e t apes. Tapes must be chemi cal l y compat i bl e wi t h t he pr oduct bei ng set .

2. 3. 5 Set t i ng Bl ocks and Edge Bl ocks

Cl osed- cel l neopr ene set t i ng bl ocks must be dense ext r uded t ype conf or mi ng t o ASTM C509 and ASTM D395, Met hod B, Shor e A dur omet er bet ween 70 and

90. Edge bl ocki ng must be Shor e A dur omet er of 50 ( pl us or mi nus 5) .

Pr ovi de si l i cone set t i ng bl ocks when bl ocks ar e i n cont act wi t h s i l i cone seal ant . Pr of i l es, l engt hs and l ocat i ons must be as r equi r ed and r ecommended i n wr i t i ng by gl ass manuf act ur er . Bl ock col or must be bl ack.

2. 3. 6 Gl azi ng Gasket s

Gl azi ng gasket s must be ext r uded wi t h cont i nuous i nt egr al l ocki ng pr oj ect i on desi gned t o engage i nt o met al gl ass hol di ng member s t o pr ovi de a wat er t i ght seal dur i ng dynami c l oadi ng, bui l di ng movement s and t her mal movement s. Gl azi ng gasket s f or a s i ngl e gl azed openi ng must be cont i nuous one- pi ece uni t s wi t h f act or y- f abr i cat ed i nj ect i on- mol ded cor ner s f r ee of f l ashi ng and bur r s. Gl azi ng gasket s must be i n l engt hs or uni t s r ecommended by manuf act ur er t o ensur e agai nst pul l - back at cor ner s.

Pr ovi de gl azi ng gasket pr of i l es as r ecommended by t he manuf act ur er f or t he i nt ended appl i cat i on.

2. 3. 6. 1 Fi xed Gl azi ng Gasket s

Fi xed gl azi ng gasket s must be cl osed- cel l ( sponge) smoot h ext r uded compr essi on gasket s of cur ed el ast omer i c v i r gi n neopr ene compounds conf or mi ng t o ASTM C509, Type 2, Opt i on 1.

SECTI ON 08 81 00 Page 6

2. 3. 6. 2 Wedge Gl azi ng Gasket s

Wedge gl azi ng gasket s must be hi gh- qual i t y ext r usi ons of cur ed el ast omer i c v i r gi n neopr ene compounds, ozone r esi st ant , conf or mi ng t o ASTM C864, Opt i on 1, Shor e A dur omet er bet ween 65 and 75.

2. 3. 6. 3 Al umi num Fr ami ng Gl azi ng Gasket s

Gl azi ng gasket s f or al umi num f r ami ng must be per manent , el ast i c, non- shr i nki ng, non- mi gr at i ng, wat er t i ght and weat her t i ght .

2. 3. 7 Accessor i es

Pr ovi de as r equi r ed f or a compl et e i nst al l at i on, i ncl udi ng gl azi ng poi nt s, c l i ps, shi ms, angl es, beads, and spacer st r i ps. Pr ovi de noncor r odi ng met al accessor i es. Pr ovi de pr i mer - seal er s and cl eaner s as r ecommended by t he gl ass and seal ant manuf act ur er s. Use ASTM C1087 t o det er mi ne whet her pr i mi ng and ot her speci f i c j oi nt pr epar at i on t echni ques ar e r equi r ed t o obt ai n r api d, opt i mum adhesi on of gl azi ng seal ant s t o sur f ace.

2. 4 ALUMI NUM PASS- THRU WI NDOWS

2. 4. 1 Bal l Bear i ng Tr ack Assembl y

Pr ovi de compl et e assembl y f or pass- t hr ough wi ndows, i ncl udi ng upper channel , shoes, car r i er s and l ower t r ack, z i nc- pl at ed. Assembl y shal l be f or 1/ 4 i nch t emper ed cl ear gl ass.

2. 4. 2 Lock pr ovi de adj ust abl e l ock f or 1/ 4 i nch sl i di ng gl ass door s wi t h di sc t umbl er , ni ckel pl at ed.

PART 3 EXECUTI ON

Any mat er i al s t hat show vi sual evi dence of bi ol ogi cal gr owt h due t o t he pr esence of moi st ur e must not be i nst al l ed on t he bui l di ng pr oj ect .

3. 1 PREPARATI ON

Pr epar at i on, unl ess ot her wi se speci f i ed or appr oved, must conf or m t o appl i cabl e r ecommendat i ons i n t he GANA Gl azi ng Manual , GANA Seal ant Manual , I GMA TB- 3001, I GMA TM- 3000, and manuf act ur er ' s r ecommendat i ons. Det er mi ne t he si zes t o pr ovi de t he r equi r ed edge cl ear ances by measur i ng t he act ual openi ng t o r ecei ve t he gl ass. Gr i nd smoot h i n t he shop gl ass edges t hat wi l l be exposed i n f i ni sh wor k. Leave l abel s i n pl ace unt i l t he i nst al l at i on i s appr oved, except r emove appl i ed l abel s on heat - absor bi ng gl ass and on i nsul at i ng gl ass uni t s as soon as gl ass i s i nst al l ed.

Secur el y f i x movabl e i t ems or keep i n a c l osed and l ocked posi t i on unt i l gl azi ng compound has t hor oughl y set .

3. 2 GLASS SETTI NG

Shop gl aze or f i el d gl aze i t ems t o be gl azed usi ng gl ass of t he qual i t y and t hi ckness speci f i ed or i ndi cat ed. Gl azi ng, unl ess ot her wi se speci f i ed or appr oved, must conf or m t o appl i cabl e r ecommendat i ons i n t he GANA Gl azi ng Manual , GANA Seal ant Manual , I GMA TB- 3001, I GMA TM- 3000, and manuf act ur er ' s r ecommendat i ons. Al umi num wi ndows, wood door s, and wood wi ndows may be gl azed i n conf or mance wi t h one of t he gl azi ng met hods

SECTI ON 08 81 00 Page 7 descr i bed i n t he st andar ds under whi ch t hey ar e pr oduced, except t hat f ace put t y i ng wi t h no beddi ng wi l l not be per mi t t ed. Handl e and i nst al l gl azi ng mat er i al s i n accor dance wi t h manuf act ur er ' s i nst r uct i ons. Use beads or st ops whi ch ar e f ur ni shed wi t h i t ems t o be gl azed t o secur e t he gl ass i n pl ace. Ver i f y pr oduct s ar e pr oper l y i nst al l ed, connect ed, and adj ust ed.

3. 2. 1 Sheet Gl ass

Cut and set wi t h t he v i s i bl e l i nes or waves hor i zont al .

3. 2. 2 I nsul at i ng Gl ass Uni t s

Do not gr i nd, ni p, or cut edges or cor ner s of uni t s af t er t he uni t s have l ef t t he f act or y. Spr i ngi ng, f or c i ng, or t wi st i ng of uni t s dur i ng set t i ng wi l l not be per mi t t ed. Handl e uni t s so as not t o st r i ke f r ames or ot her obj ect s. I nst al l at i on must conf or m t o appl i cabl e r ecommendat i ons of I GMA TB- 3001 and I GMA TM- 3000.

3. 2. 3 I nst al l at i on of Lami nat ed Gl ass

Sashes whi ch ar e t o r ecei ve l ami nat ed gl ass must be weeped t o t he out si de t o al l ow wat er dr ai nage i nt o t he channel .

3. 3 CLEANI NG

Cl ean gl ass sur f aces and r emove l abel s, pai nt spot s, put t y, and ot her def acement as r equi r ed t o pr event st ai ni ng. Gl ass must be cl ean at t he t i me t he wor k i s accept ed.

3. 4 PROTECTI ON

Pr ot ect gl ass wor k i mmedi at el y af t er i nst al l at i on. I dent i f y gl azed openi ngs wi t h sui t abl e war ni ng t apes, c l ot h or paper f l ags, at t ached wi t h non- st ai ni ng adhesi ves. Pr ot ect r ef l ect i ve gl ass wi t h a pr ot ect i ve mat er i al t o el i mi nat e any cont ami nat i on of t he r ef l ect i ve coat i ng. Pl ace pr ot ect i ve mat er i al f ar enough away f r om t he coat ed gl ass t o al l ow ai r t o c i r cul at e t o r educe heat bui l dup and moi st ur e accumul at i on on t he gl ass.

Upon r emoval , separ at e pr ot ect i ve mat er i al s f or r euse or r ecycl i ng.

Remove and r epl ace gl ass uni t s whi ch ar e br oken, chi pped, cr acked, abr aded, or ot her wi se damaged dur i ng const r uct i on act i v i t i es wi t h new uni t s.

- - End of Sect i on - -

SECTI ON 08 81 00 Page 8

08 81 00 - GLAZING
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 SYSTEM DESCRIPTION
1.4 QUALITY CONTROL
1.5 DELIVERY, STORAGE, AND HANDLING
1.6 ENVIRONMENTAL REQUIREMENTS
1.7 WARRANTY
1.7.1 Warranty for Insulated Glass Units
PART 2 PRODUCTS
2.1 GLASS
2.1.1 Clear Glass
2.1.2 Annealed Glass
2.1.3 Laminated Glass
2.1.4 Tempered Glass
2.1.5 Fire/Safety Rated Glass
2.1.5.1 Fire Protection Rated Glass
2.2 INSULATING GLASS UNITS
2.3 SETTING AND SEALING MATERIALS
2.3.1 Putty and Glazing Compound
2.3.2 Glazing Compound
2.3.3 Sealants
2.3.3.1 Elastomeric Sealant
2.3.3.2 Structural Sealant
2.3.4 Sealing Tapes
2.3.5 Setting Blocks and Edge Blocks
2.3.6 Glazing Gaskets
2.3.6.1 Fixed Glazing Gaskets
2.3.6.2 Wedge Glazing Gaskets
2.3.6.3 Aluminum Framing Glazing Gaskets

2.3.7 Accessories

2.4 ALUMINUM PASS-THRU WINDOWS
2.4.1 Ball Bearing Track Assembly
2.4.2 Lock
PART 3 EXECUTION
3.1 PREPARATION
3.2 GLASS SETTING
3.2.1 Sheet Glass
3.2.2 Insulating Glass Units
3.2.3 Installation of Laminated Glass
3.3 CLEANING
3.4 PROTECTION

File details come from the government source that posted it. Updated .