IN101 - FLOOR FINISH PLAN - SECTOR A.pdf
PDF 954 KB Posted
- Solicitation number
- W50S8T25BA011
- Issued by
-
Department of the Army National Guard
About this file
This is a floor finish plan drawing (IN101) showing sector A of a building renovation project, which includes detailed flooring specifications and room layouts. The plan depicts various rooms including a data center, crypto vault, mission team areas, offices, and support spaces, with specific flooring material designations such as carpet tiles (CPT1, CPT2), ESD carpet tile, porcelain tile (PRC1, PRC2), and raised access flooring (RAF).
The drawing includes comprehensive general notes covering installation requirements, quality standards, and contractor responsibilities. Key specifications include Class A flame spread rating requirements for all interior finishes, transition requirements between different flooring materials, and detailed installation guidelines for tile placement. The plan also indicates a concrete stage area that requires new carpet tile (CPT2) installation at 106'-0" elevation. The drawing is part of a larger renovation project (PN: YZEU142025) for the National Guard Bureau/Oklahoma Air National Guard, dated September 12, 2024, with an addendum issued February 17, 2025.
View the file
Other files
Show all 50
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FINISH LEGEND
ETR: EXISTING FLOORING TO REMAIN
CPT1: CARPET TILE, 24" X 24"
CPT2: ESD CARPET TILE, 24" X 24"
CPT3: CARPET PLANKS, 24" X 36", HALF
OFFSET
ESD1: ELECTROSTATIC DISSIPATIVE
RESILIENT TILE
PRC2: PORCELAIN TILE - UNPOLISHED,
12" X 24", 1/3 OFFSET
PRC1: ACCENT PORCELAIN FLOOR TILE
RAF: RAISED ACCESS FLOOR WITH CARPET.
CPT2 ON RAISED ACCESS FLOOR, REFER
SECTION 09 69 00 ACCESS FLOORING FOR
ADDITIONAL REQUIREMENTS
RAF: RAISED ACCESS FLOOR WITH ETR
CONC1: PENETRATING LIQUID FLOOR
TREATMENT
CONC2: ELECTROSTATIC DISSIPATIVE
CONCRETE TREATMENT OR EPOXY.
WOC1: WALK OFF CARPET TILE
A B C
D
E
F G
4a
5a
6a
7a
8a
9a
10a
11a
A'
B'
C'
D'
OFF/TRAIN.
OPS CHF.
FRAME
CP MGR.
CORR.
WOMEN
VEST.
BREAK RM
OPER TEAM
CLIENT SVC
CTR.
BREAK RM
T&T
CMDR
DATA CENTER
CRYPTO VAULT
VAULT
TEL/SWITCH
MISSION DEF
TEAM (S.O.S.)
P&R CHIEF
PRINT SUPPLY
117 CORR
VEST
UNISEX
MECH
FIRE
RISER/FACP
ELEC
VEST
RADIO SHOP
ITE
CORR
CORR
VEST
VEST
OFFICE
DATA
1ST SGT
M
AT
C H
LI
N
E
SE
E A
/ I
N
M
AT
C
H
LI
N E
SE
E
A
/ I N
A/V ROOM
MULTI-USE
174B
EXTENT OF
CONCRETE STAGE
STAGE ACCESS STAIRS
THIS AREA TO BE FILLED
IN TO ACCOMODATE THE
NEW CARPET TILE (CPT2)
FLOOR AT 106'-0"
ELEC.
126.1
EXISTING TO REMAIN -
REPAIR RAISED
ACCESS FLOOR AS
NECESSARY
RAMP
P&R
CORR.
CORR.
OPEN OFFICE
C.A.T.
AWP V
UPPT3
PT3
SHOWER
120.1
WWC1
12" ACCENT TILE BAND
(ONE FULL TILE OF PRC1)
START FIRST TWO TILES
AT THE CENTERLINE
OF THE ENTRY DOOR
CENTER FIRST
CARPET PLANK ON
THIS DOOR
AWP1
W T1
W T1
W T1
W T1
W T1
WT1
O N
IN
TE
R
IIO
R
SI
D E
O F
W
IN
D O
W
O N
IN
TE
R
IIO
R
SI
D E
O F
W
IN
D O
W
O N
IN
TE
R
IIO
R
SI
D E
O F
W
IN
D O
W
ON INTERIIOR
SIDE OF WINDOW
GENERAL NOTES
A. ALL INTERIOR FINISHES SHALL HAVE CLASS A
FLAME SPREAD RATING.
B. ALL FLOORING IS NEW UNLESS NOTED
OTHERWISE.
C. FLOORING TRANSITION TO BE LOCATED UNDER
DOOR IN CLOSED POSITION.
D. EXTEND FLOORING MATERIALS INTO ALL
KNEESPACES, TOE SPACES, ETC.
E. PROVIDE SMOOTH TRANSITION BETWEEN
DIFFERENT FLOORING MATERIALS.
F. THERE SHALL BE NO FLOOR TILE PIECES
INSTALLED LESS THAN 3”. COORDINATE WITH
ARCHITECT PRIOR TO INSTALLATION.
G. ALL TILED FLOORING INSTALLATIONS SHALL
BEGIN WITH A FULL TILE CENTERED IN ROOM,
UNLESS NOTED OTHERWISE. IF CENTERING FULL
TILE RESULTS IN LESS THAN 6” WIDE AT THE
PERIMETER OF THE ROOM, ADJUST START POINT
BY HALF TILE WIDTH IN BOTH DIRECTIONS.
H. VARIATIONS IN FLOOR LEVEL IN EXCESS OF 1/2"
FOR EVERY 10'-0" SHALL BE LEVELED BY
CONSTRACTOR. LEVELING SHALL BE
COMPLETED WITH FLOOR READY TO RECEIVE
NEW FINISHES AS SPECIFIED. CONTRACTOR
SHALL VERIFY SLAB CONDITION PRIOR TO BID
SUBMISSION.
I. ALL MISCELLANEOUS GRILLES, PLATES OR
OTHER DEVICES SHALL BE PAINTED TO MATCH
THE WALL OR CEILING IN WHICH THEY ARE
INSTALLED.
J. G.C. SHALL BE RESPONSIBLE FOR PROVIDING
BLOCKING AS RQUIRED FOR ALL ITEMS
INCLUDING BUT NOT LIMITED TO CABINETS,
TOILET ACCESSORIES AND FF&E.
K. ALL NEW WALL CONSTRUCTION AND/OR WALL,
CEILING AND FLOOR INFILL THAT TIES INTO
EXISTING CONSTRUCTION SHALL BE FURRED OUT
AS REQUIRED TO ALIGN WITH EXISTING
ADJACENT OR ABUTTING. ALL SEAMS AND
JOINTS SHALL BE FULLY CONCEALED, TYPICAL
THROUGHOUT.
L. G.C. IS RESPONSIBLE FOR REPAIRS FOR ANY
DAMAGE TO NEW OR EXISTING ITEMS DUE TO
CONSTRUCTION WORK, TYPICAL. FULLY
PROTECT ALL FINISHES DUE TO CONSTRUCTION
WORK. CONTRACTOR IS FULLY RESPONSIBLE
FOR REPAIRING ANY DAMAGES, NICKS,
SCRATCHES.
M. PATCH AND SAND ALL EXISTING WALLS THAT
WERE DAMAGED OR HAD ITEMS REMOVED.
WALLS, COLUMNS, SOFFITS, ETC. TO BE READY
FOR PAINT.
N. INTERIOR PAINTING SHALL INCLUDE ALL PREP
WORK, ONE COAT PRIMER AND TWO COATS
FINISH. REFER TO SECTION 09 90 00 PAINTS AND
COATINGS.
O. FLOORING AND BASE: ALL FLOORING SHALL BE
INSTALLED PER MANUFACTURER'S
RECOMMENDATIONS REGARDING ADHESIVES,
SEAMING, DIRECTION, ETC. AND SHALL BE
COMPLIANT WITH SPECIFICATIONS.
DISCREPANCIES ARE TO BE BROUGHT TO THE
ATTENTION OF THE INTERIOR DESIGNER.
P. ALL PAINT COLORS SHALL BE REVIEWED WITH
THE INTERIOR DESIGNER AND GOVERNMENT
PRIOR TO PAINTING.
Q. PROVIDE 1" ALUMINUM MINI-BLINDS AT ALL
EXTERIOR WINDOWS.
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
Frankfurt-Short-Bruza Associates,P.C.
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
2020-484-00
NDM
Re pa ir/ Co nv er t S qu ad O ps Ok lah om a C ity
, O K
NG
BJ
V/
OK
A
NG
PN: YZEU142025
C :\U sers\tw ood\ O neD rive - FS
B Architects + Engineers\D ocu m ents\048400_A
R C
H _tw oodD
XX
EM
.rvt
2/14/2025 3:20: 16 PM
12 SEPTEMBER 2024
FLOOR FINISH PLAN - SECTOR
A
IN101
TLW
KD
KD
0 4' 8' 16'
1/8" = 1'-0"
N
PROJECT
KEYPLANN
A B
SCALE: 1/8" = 1'-0"
FLOOR FINISH PLAN - SECTOR 'A'A3
C
2 ADDENDUM 01 02/17/2025
File details come from the government source that posted it. Updated .