AE403 - ENLARGED PLANS.pdf
PDF 447 KB Posted
- Solicitation number
- W50S8T25BA011
- Issued by
-
Department of the Army National Guard
About this file
This is an architectural drawing (sheet AE403) showing enlarged floor plans for three break rooms (103, 134, and 145) in Building 1040 at Will Rogers Air National Guard Base. The drawing includes detailed dimensions, fixtures, and equipment placement for each break room, with common elements including manual paper towel dispensers, soap dispensers, sinks, countertops, and acoustical wall panels.
The plans specify Government Furnished/Government Installed (GF/GI) items and Contractor Furnished/Contractor Installed elements. Key specifications include centering TV mounts and acoustical wall panels, requirements for tile edge treatments using satin anodized aluminum finish trim, and installation of corner guards at outside corners of gypboard walls. The drawing is dated September 12, 2024 and includes a February 17, 2025 addendum, and was prepared by Frankfurt-Short-Bruza Associates for the Oklahoma Air National Guard Joint Base renovation project.
View the file
Other files
Show all 50
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W M
D
CR
SC
C
D M
STANDARD PARTITION - NEW WALL
BATT INSULATION - NEW WALL
EXISTING PARTITION (NOT DEMO'D)
FLOOR PLAN LEGEND
CJ DENOTES LOCATION OF DRYWALL
CONTROL JOINT
EXISTING ACCESS FLOOR SYSTEM
SECURE BOUNDARY
AE411
A3
A2
B3
BREAK RM
MC1
14 24
REF1
IM1
CM1
FIRE
EXTINGUISHER
AWP1: REFER
B3/AE411
3' -9
/2
9'-3 3/8"5'-7 1/2"
2' -0
12'-0"
2'-0"
TV2
6a
7a
AE411 C3
B2
BREAK RM
MC1
AWP1
CM1
REF1
IM1
C3C3
C3
C3
C3
5'-6 3/8"
6' -6
/2
5' -6
/8
F
AE411
C2
MC1
24 14
AWP1
REF1
CM1
3'-7" 11'-4 7/8"
GENERAL NOTES
A. ALL INTERIOR DIMENSIONS ARE FROM FACE OF
WALL FINISH TO FACE OF WALL FINISH - U.N.O.
B. REFER TO SHEETS AE600 ROOM FINISH
SCHEDULE AND IN600 INTERIOR MATERIALS
LEGEND FOR BASIS OF DESIGN INTERIOR
FINISHES, MATERIALS, PATTERNS AND COLORS.
C. THERE SHALL BE NO EXPOSED TILE EDGES.
EXPOSED TILE EDGES SHALL HAVE A SATIN
ANODIZED ALUMINUM FINISH TRIM.
D. USE GRIDS PROVIDED FOR BASIS OF WALL TILE
INSTALLATION.
E. CONTRACTOR IS RESPONSIBLE FOR FIELD
VERIFICATION OF ALL DIMENSIONS AND MUST
NOTIFY ARCHITECT IMMEDIATELY OF ANY
DISCREPANCIES BETWEEN FIELD CONDITIONS
AND THESE DRAWINGS.
F. REFER TO MECHANICAL, ELECTRICAL, AND
PLUMBING DRAWINGS FOR INFORMATION
RELATING TO DEVICES AND FIXTURES.
G. CORNER GUARDS ARE NOT SHOWN IN INTERIOR
ELEVATIONS FOR GRAPHIC CLARITY, PROVIDE AT
OUTSIDE CORNERS OF GYPBOARD WALLS.
H. CONTRACTOR SHALL VERIFY ALL REQUIRED
CLEARANCES FOR FIXTURES AND/OR EQUIPMENT
SHOWN AND ENSURE CORRECT FIT.
I. GF/GI = GOVERNMENT FURNISHED /
GOVERNMENT INSTALLED. REFER TO SHEET IF
101 AND IF102 FURNITURE PLANS WHERE THE
FURNITURE SCHEDULE INDICATES ITEMS THAT
ARE GF/GI.
J. TOILET ACCESSORIES ARE CONTRACTOR
FURNISHED / CONTRACTOR INSTALLED, EXCEPT
FOR GOVERNMENT PROVIDED DISPENSERS,
INCLUDING PAPER TOWEL DISPENSERS, SOAP
DISPENSERS AND TOILET PAPER DISPENSERS.
THESE WILL BE INSTALLED BY THE CONTRACTOR.
COORDINATE INSTALLATION OF THESE WITH THE
GOVERNMENT.
K. CENTER FIRST ACOUSTICAL WALL PANEL ON
WALL. CUT SUBSEQUENT PANELS TO FIT.
L. CENTER TV MOUNT ON WALL IN BREAK ROOM.
CUT ACOUSTICAL PANELS TO FIT TV MOUNT
BRACKET. ENSURE DATA AND POWER ARE
INSTALLED WITHIN CUTOUT.
M. IN BREAK ROOM 103, INSTALL AWP1 FROM
FLOOR TO CELING..
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
Frankfurt-Short-Bruza Associates,P.C.
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
2020-484-00
NDM
Re pa ir/ Co nv er t S qu ad O ps Ok lah om a C ity
, O K
NG
BJ
V/
OK
A
NG
PN: YZEU142025
C :\U sers\bkg\D o cum ents\M y R evit\048400_AR C
H
_BG
allagher5SB23.rvt
2/14/2025 8:31: 13 AM
12 SEPTEMBER 2024
ENLARGED PLANS
AE403
MJT
KD
JO
N
0 1' 2' 4'
1/2" = 1'-0"
SCALE: 1/2" = 1'-0"
ENLARGED PLAN - BREAKROOM 145A1 SCALE: 1/2" = 1'-0"
ENLARGED PLAN - BREAKROOM 103A3
SCALE: 1/2" = 1'-0"
ENLARGED PLAN - BREAKROOM 134C3
1. TOILET PARTITION, TYP.
2. GRAB BARS - 36" BACK WALL, 42" SIDE WALL
3. TOILET PAPER DISPENSER, GFCI
4. TOILET SEAT COVER DISPENSER
5. SANITARY NAPKIN DISPOSAL
6. ADA URINAL
7. URINAL SCREEN
8. PLASTIC LOCKERS (HPDE) - 2 TIER Z-STYLE, SLOPED
TOP
9. ADA WATER CLOSET, WALL MOUNTED
10. ADA SHOWER W/GRAB BAR AND SHOWER SEAT
11. ADA DRINKING FOUNTAIN WITH BOTTLE FILLER
12. CELL PHONE LOCKER
13. SINK AND FAUCET
14. MANUAL PAPER TOWEL DISPENSER, GF/CI
15. UTILITY SHELF
16. MOP SINK (NOT SHOWN)
17. MIRROR (18" X 30")
18. WATER HEATER
19. SHOWER CURTAIN AND ROD
20. SHOWER INSERT, SOLID SURFACE WALLS AND
PREFORMED TERRAZZO BASE. REFER SHEET I600
FOR MATERIALS.
21. 30" X 48" ADA CLEARANCE
22. 5'-0" ADA CLEARANCE
23. URINAL (NON-ADA)
24. SOAP DISPENSER, GF/CI
25. SOLID SURFACE COUNTERTOP
26. WALL MTD TOILET, NON-ADA
27. LOCKER BENCH, 72" W X 19" D
28. CLEAN OUT
29. PORCELAIN WALL TILE
30. HIGH PRESSURE LAMINATE
31. PAINT
32. CEILING AS SCHEDULED
33. WALL BASE AS SCHEDULED
34. PANELBOARD
SHEET KEYNOTES
2 ADDENDUM 01 02/17/2025
File details come from the government source that posted it. Updated .