AE102 - FLOOR PLAN - SECTOR A.pdf

PDF 497 KB Posted

Attached to
137th SOW - Building 1040 Repair / Renovation Project
Solicitation number
W50S8T25BA011
Issued by

About this file

This file is an architectural floor plan drawing (Sheet AE102) showing the layout and design details for Sector A of Building 1040 at Will Rogers Air National Guard Base. The drawing depicts various rooms and spaces including a data center, operations areas, offices, corridors, break rooms, and utility spaces like mechanical and electrical rooms.

The floor plan includes detailed dimensions, wall types, door locations, and construction notes. Key features shown include new exterior wall framing with brick veneer, secure boundary demarcations, access floor systems, and specific requirements for secure areas such as the data center. The drawing contains extensive general notes and keynotes covering construction requirements, including specifications for drywall control joints, interior partitions, and secure area requirements such as floor-to-deck walls, hard ceilings, X10 locks, and penetration protection. This drawing is part of a larger renovation project (YZEU142025) dated September 12, 2024, with Addendum 01 issued February 17, 2025, prepared by Frankfurt-Short-Bruza Associates for the Oklahoma Air National Guard.

View the file

Other files

File Type Posted
Abstract (Final).pdf PDF
Amendment 3 Attachment 1 - Bldg 1040 Reno Questions and Answers.docx DOCX document
Solicitation Amendment 3 W50S8T25BA0110003.pdf PDF
NEW 6 Mar 25 Oklahoma NGB-WRWA - 100 CD Set Part 1.pdf PDF
NEW 6 Mar 25 Oklahoma NGB-WRWA - 100 CD Set Part 2.pdf PDF
Amendment 2 Attachment 2 - 09 72 00.pdf PDF
Amendment 2 Attachment 5 - IN600 - INTERIORS MATERIALS LEGEND.pdf PDF
Amendment 2 Attachment 3 - A-002 - PARTITION TYPES.pdf PDF
Amendment 2 Attachment 6 - Bldg 1040 Reno Questions and Answers.xlsx XLSX spreadsheet
Amendment 2 Attachment 1 - Addendum 02 Narrative.docx DOCX document
Solicitation Amendment 2 W50S8T25BA0110002.pdf PDF
Amendment 2 Attachment 4 - 08 11 16.pdf PDF
06 20 00.pdf PDF
21 13 13.pdf PDF
IN101 - FLOOR FINISH PLAN - SECTOR A.pdf PDF
Bldg 1040 Reno Questions and Answers - FSB and GOV Reponses.xlsx XLSX spreadsheet
EL101 - ELECTRICAL INTERIOR LIGHTING PLAN - SECTOR A.pdf PDF
AE502 - DETAILS.pdf PDF
AE403 - ENLARGED PLANS.pdf PDF
10 21 13.pdf PDF
10 51 13.pdf PDF
08 41 13.pdf PDF
AE103 - FLOOR PLAN - SECTOR B.pdf PDF
08 81 00.pdf PDF
AE411 - INTERIOR ELEVATIONS.pdf PDF
AE402 - ENLARGED PLANS.pdf PDF
AE601 - DOOR SCHEDULE AND DETAILS.pdf PDF
26 05 73.pdf PDF
08 11 16.pdf PDF
AE602 - OLI 1 - EXTERIOR WINDOW FRAMES.pdf PDF
Addendum 01 Narrative.docx DOCX document
08 71 00.pdf PDF
IN102 - FLOOR FINISH PLAN - SECTOR B.pdf PDF
Solicitation Amendment 1 W50S8T25BA0110001 SF 30.pdf PDF
06 41 16.00 10.pdf PDF
AE201 - BUILDING ELEVATIONS.pdf PDF
TABLE OF CONTENTS.pdf PDF
A-002 - PARTITION TYPES.pdf PDF
01 45 35.pdf PDF
FA601 - FIRE ALARM - MASS NOTIFICATION RISER DIAGRAM.pdf PDF
AE151 - REFLECTED CEILING PLAN - SECTOR A.pdf PDF
AE600 - ROOM FINISH SCHEDULE.pdf PDF
10 51 16.pdf PDF
30 Jan 25 Site Visit Sign In Sheet.pdf PDF
BLDG 1040 Renovation Site Visit Slides 30 January 25.pptx PPTX presentation
ATTACHMENT 3 - 2024.09.12_OK-ANG_SQUADOPS B1040_TYPE B3_SPECIFICATIONS VOL. 2.pdf PDF
Solicitation - W50S8T25BA011.pdf PDF
ATTACHMENT 2 - 2024.09.12_OK-ANG_SQUADOPS B1040_TYPE B3_SPECIFICATIONS VOL. 1.pdf PDF
Bidders Checklist.docx DOCX document
ATTACHMENT 1 - 2024.09.12_OK-ANG_SQUADOPS B1040_TYPE B3_DRAWINGS.pdf PDF
Show all 50

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SD

AE201

D1

AE201

C1

AE201

B1

A B C

D

D

E

E

F

F

G

G

4a

5a

6a

7a

8a

9a

10a

11a

A'

B'

C'

D'

AE301

D1

AE301

D1

OFF/TRAIN.

OPS CHF.

FRAME

CP MGR.

CORR.

WOMEN

VEST.

BREAK RM

OPER TEAM

CLIENT SVC

CTR.

BREAK RM

T&T

CMDR

DATA CENTER

CRYPTO VAULT

VAULT

TEL/SWITCH

MISSION DEF

TEAM (S.O.S.)

P&R CHIEF

PRINT SUPPLY

CORR

VEST

UNISEX

MECH

FIRE

RISER/FACP

ELEC

VEST

RADIO SHOP

ITE

CORR

VEST

VEST

17'-4 1/4" 6'-4 1/4"

5' -7

/2

8'

-5

'-7

/4

5'

-0

/2

9' -5

/2

9'

-0

8' -6

3/ 4"

OFFICE

CORR

M

AT

C H

LI

N

E

SE

E A

AE

M

AT

C H

LI

N

E

SE

E A

AE

DATA

1ST SGT

3A

137A

136A 132A

135A

9B

9A

173A

4A

4B

122A

3A

1A

8A

8B

6A

2A

127A

112A

111A

4A

107A

105A

104A

125A

0A

4B

128A

8A

0B

0A

141A

A1

AE402

'-1

/2

11'-11"

5'-6 1/2"

14'-10" 3'-7 1/2"

IN1

5'-11" 3'-1 1/4"

7' -6

9'

-5

/4

C1

AE402

OH

SHOWER

120.1

117A

5B

10 11 10 11

12 12

D

IS

PL

AY

C

AS

E

I3I3

*A3

*A3

*A3

*A3

*B1 *B1 *B1

*A3

*A3

I3

F3F3

*A3 *A3

*A3

*B1

*B1

*B1 *A3

*A3

*A3

*A3

*A3*A3

*R3

*A3

C3

C3

*A3

*A3

*A3

*A3

*A3

*A3 5

*A3 *A6

*A3*A6

*A3

CJ

CJ

CJ

5A

106A

C3

AE401

IN3

AE301

A2

0B

A1

AE401

116A

1'-6"

UP

'-5

/2

9'-9" 3'-7"

VE

R

IF

Y

'-3

/8

ALIGN

2'-3"

ALIGN

*R3

*R3 ELEC.

126.1 126.1A

OPEN OFFICE

AE301

A4

MULTI-USE

174B

CORR.

P&R

A/V ROOM

C3

C3

ALIGN

A3

AE403

C3

AE403

NEW EXTERIOR WALL

FRAMING AND BRICK

VENEER

A4

AE102

AC

C

ES

S

FL

O

O R

A4

AE501

A

D

A

A

A

D

IN4

EX4

C

STAGE ACCESS STAIRS

THIS AREA TO BE FILLED

IN TO ACCOMODATE THE

NEW CARPET TILE FLOOR

AT 100'-6". REFER SHEET

IN101 FLOOR FINISH PLAN.

EXTENT OF CONCRETE

STAGE JOINING TO NEW

ACCESS PANEL FLOOR

SYSTEM

NEW EXTERIOR

DOUBLE DOOR

0B

R6

R6R6R6

R6

R6R6

R6

F2W 12 '-0

107B

7'-0 5/8" *A3

A

A

STANDARD PARTITION - NEW WALL

BATT INSULATION - NEW WALL

EXISTING PARTITION (NOT DEMO'D)

FLOOR PLAN LEGEND

CJ DENOTES LOCATION OF DRYWALL

CONTROL JOINT

EXISTING ACCESS FLOOR SYSTEM

SECURE BOUNDARY

GENERAL NOTES

A. ALL DIMENSIONS ARE FROM FACE OF STUD TO

FACE OF STUD, OR FROM FACE OF CMU, OR FACE

OF CONCRETE AS INDICATED - UNO (IF NO GWB IS

PART OF THE PARTITION ASSEMBLY).

B. MATERIALS AND PRODUCTS SHALL MEET ALL

CRITERIA IN DRAWINGS AND SPECIFICATIONS.

DUE TO THE VARIATION OF PROPRIETARY

PRODUCTS BETWEEN MANUFACTUERS, THE

CONTRACTOR SHALL FULLY COORDINATE AND

MAKE NECESSARY ADJUSTEMENTS TO MEET THE

DESIGN INTENT.

C. DRYWALL CONTROL JOINT LOCATIONS ARE

MARKED WITH A 'CJ' ON THE PLAN. DRYWALL

CONTROL JOINTS ARE TO BE PLACED A MINIMUM

OF 30'-0" ON CENTERS AT ALL UNINTERRUPTED

LENGTHS OF DRYWALL AND CENTERED ON BOTH

SIDES OF DOOR FRAMES AT ALL INTERIOR

DOORS TO TRUE TOP OF WALL.

D. INTERIOR PARTITIONS AT CORRIDORS ARE TO

USE ABUSE-RESISTANT GYP BD TO 8'-0" AFF.

E. INTERIOR PARTITIONS AT WET WALLS,

RESTROOMS, KITCHENS, JANITOR CLOSETS, AND

LOADING DOCK AREAS ARE TO USE GLAS-MAT

BACKED GYP BD.

SHEET KEYNOTES

1. UTILITY SINK

2. FIRE EXTINGUISHER CABINET OR BRACKET

3. FOLDING PARTITION DOOR

4. NOT USED

5. INFILL OPENING TO MATCH EXISTING

6. EXISTING STORAGE FENCE SYSTEM TO REMAIN

7. EXISTING O.H. DOOR TO REMAIN

8. EXISTING ACCESS LADDER TO REMAIN

9. CELL PHONE LOCKERS

10. PATCH AND REPAIR EXISTING FLOORING SYSTEM.

VACUUM AND CLEAN DEBRIS, DUST FROM UNDER

EXISTING TILE. VERIFY THAT EXISTING STATIC

ELECTRICAL GROUNDS ARE WORKING. CONTRACTOR

IS TO INSPECT EXISTING SLAB AND WALLS FOR

LEAKS AND/OR DAMAGE BEFORE REPAIRING AS

NEEDED. THESE OR ANY OTHER ISSUES ARE TO BE

BROUGHT TO THE ATTENTION OF THE OWNER'S

REPRESENTATIVE FOR THE PROJECT.

11. CEILING AND LIGHT FIXTURES TO BE REPLACED

CONCURRENT WITH WORK ON FIRE SUPPRESSION

EQUIPMENT IN THIS AREA

12. CONTRACTOR TO INSPECT AND VERIFY EXISTING

CONDITIONS OF WALL CONSTRUCTION AND HEAD OF

WALL CONDITION CONCURRENT WITH WORK ON FIRE

SUPPRESSION SYSTEM, THIS AREA ONLY. HEAD OF

WALL TO BE REPAIRED WHERE NECESSARY AND

CONFIGURED FOR A 1-HR RATED PARTITION. REFER

TO WALLTYPE DETAILS SHEET A-002.

13. NEW CONCRETE RAMP CONSTRUCTION AND

GUARDRAILS

14. OLI #1 - NEW STOREFRONT FRAME AND GLAZING

SYSTEM. VERIFY CONDITIONS AND CLEARANCES.

FIELD VERIFY ANCHORING CONDITIONS TO EXISTING

CONSTRUCTION.

15. VISION OBSCURING FILM TO BE ADDED TO THE

INTERIOR SIDE OF THE EXTERIOR GLAZING.

16. IN THESE AREAS WHERE SECURE PERIMETER IS

LOCATED THE WALLS ARE TO MEET THE FOLLOWING

REQUIREMENTS:

1. THEY SHALL EXTEND FROM FLOOR TO DECK.

2. THEY SHALL HAVE A HARD CEILING OR GO TO

DECK.

3. ENTRY TO TEH SECURE AREA SHALL HAVE X10

LOCKS.

4. WINDOWS LESS THAN 18" A.F.F. SHALL HAVE

PROTECTION FROM FORCED ENTRY OR IDS AND

NOT ALLOW VISUAL OBSERVATION.

5. PENETRATIONS INTO THE SECURE AREA THAT

ARE GREATER THAN 96" SQUARED MUST HAVE

MAN-BARS.

6. IDS SHALL BE INSTALLED PER ELECTRICAL

DRAWINGS.

7. ACCESS CONTROL SHALL BE INSTALLED PER

ELECTRICAL DRAWINGS.

10a

B'

OFFICE

P&R CHIEF

DATA CENTER

*A3 *A3

*A3

NEW WALL TO REMAIN

AFTER DATA CENTER

CONST.

NEW WALL TO REMAIN

AFTER DATA CENTER

CONST.

WALL TO BE REMOVED

AND DOOR TO BE

RELOCATED TO '110B'

AFTER DATA CENTER

CONST.

5'-2 3/4"

112A

0A

0B

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

Frankfurt-Short-Bruza Associates,P.C.

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

C

B

A

D

C

B

A

54321

2020-484-00

NDM

Re pa ir/ Co nv er t S qu ad O ps Ok lah om a C ity

, O K

NG

BJ

V/

OK

A

NG

PN: YZEU142025

C :\U sers\bkg\D o cum ents\M y R evit\048400_AR C

H

_BG

allagher5SB23.rvt

2/14/2025 8:31: 00 AM

12 SEPTEMBER 2024

FLOOR PLAN - SECTOR A

AE102

MJT

MRT

JO

0 4' 8' 16'

1/8" = 1'-0"

N

PROJECT

KEYPLANN

A B

SCALE: 1/8" = 1'-0"

FLOOR PLAN - SECTOR AA1 SCALE: 1/4" = 1'-0"

TEMPORARY BARRIER PLANA4

N

0 2' 4' 8'

1/4" = 1'-0"

2 ADDENDUM 01 02/17/2025