AE103 - FLOOR PLAN - SECTOR B.pdf
PDF 573 KB Posted
- Solicitation number
- W50S8T25BA011
- Issued by
-
Department of the Army National Guard
About this file
This is a floor plan drawing (Sheet AE103) showing the detailed layout of Sector B for Building 1040 renovation at Will Rogers Air National Guard Base. The drawing depicts various rooms and spaces including offices, corridors, vestibules, mission planning areas, briefing rooms, shower facilities, and specialized military spaces like SERE, HARM, Special Ops, and Security Communications rooms.
The floor plan includes detailed construction notes regarding secure boundary requirements, wall specifications, and finish details. Key features include new storefront frame and glazing systems, vision obscuring film requirements, and specific security measures like X10 locks and IDS installation requirements. The drawing provides precise measurements, door locations, and partition types, with special attention to secure area requirements including walls extending floor to deck and protection requirements for windows below 18" AFF. The drawing was issued on September 12, 2024 with an addendum dated February 17, 2025, and was prepared by Frankfurt-Short-Bruza Associates for the NGBJV/OK ANG project number YZEU142025.
View the file
Other files
Show all 50
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AE201
A1
AE201
D1
AE201
B1
G
G
H
H
K
K
NMLJ
J
4b
5b
6b
7b
8b
9b
10b
11b
N'
M'
L' k'
AE301
D1
AE301
D1
AE301
B1
AE301
B1
CORR.
VEST.
CORR
EA/ADMIN
C.A.T.
MEN
CMNDR.
CHF.
1ST SGT.
OFFICE
OFFICE
MECH
ELEC
UNISEX
CORR
MISSION
PLANNING
AFM
VEST
VEST
8' -5
/4
'-5
/2
'-0
5'
-6
/2
6'-1"
17'-0"
10 1/2"
SEC COMM
SPECIAL OPS
(S.O.S.)
VEST.
6' -3
/4
'-2
M
AT
C H
LI
N
E
SE
E A
AE
M
AT
C H
LI
N
E
SE
E A
AE
SERE
HARM
BRIEFING
BRIEFING
OFFICE
OFFICE
WX
SHOWER
JANITOR
A/V ROOM
1C
4A
130A
146A
148A
152A
160A
161A
162A
163A
164A
170A
167A
165A
4A
172A
0A
1A
149A
3B
3A
4A
155A
1A
1B
A1
AE402
C3
AE402
OH
IN2
IN1
157A
5'-11" 3'-1 1/4" 23'-8 1/2" 3 1/2"
7' -6
9'
-5
/4
14'-10 3/4"
9'-10 1/4"
13'-6"
14'-0"
14'-10" 11'-9 1/2"*A3
*A3
*A3
*A3
*B1
*B1
*B1
*A3
*A3
*A3
*A3
*A3
*A6
*A3
*A3
*A3
*A3
*A3
*A3
*A3
*B1
*A3*A3
*A3
*B1
*B1
*A3
*A3
*B1
*B1
*B1*B1
*A3 *A3*A3
*A3
*A6
CJ
CJ
CJ
CJ
CJ
1B
B2
AE501
B1
AE501
ELEC.
147A
*R3 105°
7' -7
/2
6'
-3
/4
'-2
5' -7
/2
'-0
1'-6"
25'-4 3/8"
UP
*R3
*R3
*R3 F1
VEST.
168A
159A
*A3
*A3
SHOP
OPEN OFFICE
OPEN OFFICE
BREAK RM
MULTI-USE
174A
MULTI-USE
174B
145A
148B
*A3
*B1
*B1
ALIGN ALIGN
ALIGN
ALIGN
A1
AE403
AC
C
ES
S
FL
O
O R
14 14 14
*A3
3A
B BC
A
A
D
D
D
D
D
IN4
EX4
STAGE ACCESS STAIRS
THIS AREA TO BE FILLED
IN TO ACCOMODATE THE
NEW CARPET TILE FLOOR
AT 100'-6". REFER SHEET
IN102 FLOOR FINISH PLAN.
EXTENT OF CONCRETE
STAGE JOINING TO NEW
ACCESS PANEL FLOOR
SYSTEM - ALIGN TO SAME
ELEVATION.
*B1
*B1
169A
R6R6
R6 R6
R6 R6
CJ
F3
F3
F3
F3
*A3
F3
F3
F3
166A
167B
7'-0 5/8" *A3
STANDARD PARTITION - NEW WALL
BATT INSULATION - NEW WALL
EXISTING PARTITION (NOT DEMO'D)
FLOOR PLAN LEGEND
CJ DENOTES LOCATION OF DRYWALL
CONTROL JOINT
EXISTING ACCESS FLOOR SYSTEM
SECURE BOUNDARY
GENERAL NOTES
A. ALL DIMENSIONS ARE FROM FACE OF STUD TO
FACE OF STUD, OR FROM FACE OF CMU, OR FACE
OF CONCRETE AS INDICATED - UNO (IF NO GWB IS
PART OF THE PARTITION ASSEMBLY).
B. MATERIALS AND PRODUCTS SHALL MEET ALL
CRITERIA IN DRAWINGS AND SPECIFICATIONS.
DUE TO THE VARIATION OF PROPRIETARY
PRODUCTS BETWEEN MANUFACTUERS, THE
CONTRACTOR SHALL FULLY COORDINATE AND
MAKE NECESSARY ADJUSTEMENTS TO MEET THE
DESIGN INTENT.
C. DRYWALL CONTROL JOINT LOCATIONS ARE
MARKED WITH A 'CJ' ON THE PLAN. DRYWALL
CONTROL JOINTS ARE TO BE PLACED A MINIMUM
OF 30'-0" ON CENTERS AT ALL UNINTERRUPTED
LENGTHS OF DRYWALL AND CENTERED ON BOTH
SIDES OF DOOR FRAMES AT ALL INTERIOR
DOORS TO TRUE TOP OF WALL.
D. INTERIOR PARTITIONS AT CORRIDORS ARE TO
USE ABUSE-RESISTANT GYP BD TO 8'-0" AFF.
E. INTERIOR PARTITIONS AT WET WALLS,
RESTROOMS, KITCHENS, JANITOR CLOSETS, AND
LOADING DOCK AREAS ARE TO USE GLAS-MAT
BACKED GYP BD.
SHEET KEYNOTES
1. UTILITY SINK
2. FIRE EXTINGUISHER CABINET OR BRACKET
3. FOLDING PARTITION DOOR
4. NOT USED
5. INFILL OPENING TO MATCH EXISTING
6. EXISTING STORAGE FENCE SYSTEM TO REMAIN
7. EXISTING O.H. DOOR TO REMAIN
8. EXISTING ACCESS LADDER TO REMAIN
9. CELL PHONE LOCKERS
10. PATCH AND REPAIR EXISTING FLOORING SYSTEM.
VACUUM AND CLEAN DEBRIS, DUST FROM UNDER
EXISTING TILE. VERIFY THAT EXISTING STATIC
ELECTRICAL GROUNDS ARE WORKING. CONTRACTOR
IS TO INSPECT EXISTING SLAB AND WALLS FOR
LEAKS AND/OR DAMAGE BEFORE REPAIRING AS
NEEDED. THESE OR ANY OTHER ISSUES ARE TO BE
BROUGHT TO THE ATTENTION OF THE OWNER'S
REPRESENTATIVE FOR THE PROJECT.
11. CEILING AND LIGHT FIXTURES TO BE REPLACED
CONCURRENT WITH WORK ON FIRE SUPPRESSION
EQUIPMENT IN THIS AREA
12. CONTRACTOR TO INSPECT AND VERIFY EXISTING
CONDITIONS OF WALL CONSTRUCTION AND HEAD OF
WALL CONDITION CONCURRENT WITH WORK ON FIRE
SUPPRESSION SYSTEM, THIS AREA ONLY. HEAD OF
WALL TO BE REPAIRED WHERE NECESSARY AND
CONFIGURED FOR A 1-HR RATED PARTITION. REFER
TO WALLTYPE DETAILS SHEET A-002.
13. NEW CONCRETE RAMP CONSTRUCTION AND
GUARDRAILS
14. OLI #1 - NEW STOREFRONT FRAME AND GLAZING
SYSTEM. VERIFY CONDITIONS AND CLEARANCES.
FIELD VERIFY ANCHORING CONDITIONS TO EXISTING
CONSTRUCTION.
15. VISION OBSCURING FILM TO BE ADDED TO THE
INTERIOR SIDE OF THE EXTERIOR GLAZING.
16. IN THESE AREAS WHERE SECURE PERIMETER IS
LOCATED THE WALLS ARE TO MEET THE FOLLOWING
REQUIREMENTS:
1. THEY SHALL EXTEND FROM FLOOR TO DECK.
2. THEY SHALL HAVE A HARD CEILING OR GO TO
DECK.
3. ENTRY TO TEH SECURE AREA SHALL HAVE X10
LOCKS.
4. WINDOWS LESS THAN 18" A.F.F. SHALL HAVE
PROTECTION FROM FORCED ENTRY OR IDS AND
NOT ALLOW VISUAL OBSERVATION.
5. PENETRATIONS INTO THE SECURE AREA THAT
ARE GREATER THAN 96" SQUARED MUST HAVE
MAN-BARS.
6. IDS SHALL BE INSTALLED PER ELECTRICAL
DRAWINGS.
7. ACCESS CONTROL SHALL BE INSTALLED PER
ELECTRICAL DRAWINGS.
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
Frankfurt-Short-Bruza Associates,P.C.
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
2020-484-00
NDM
Re pa ir/ Co nv er t S qu ad O ps Ok lah om a C ity
, O K
NG
BJ
V/
OK
A
NG
PN: YZEU142025
C :\U sers\bkg\D o cum ents\M y R evit\048400_AR C
H
_BG
allagher5SB23.rvt
2/14/2025 8:31: 03 AM
12 SEPTEMBER 2024
FLOOR PLAN - SECTOR B
AE103
MJT
MRT
JO
0 4' 8' 16'
1/8" = 1'-0"
N
PROJECT
KEYPLANN
A B
SCALE: 1/8" = 1'-0"
FLOOR PLAN - SECTOR BA2
2 ADDENDUM 01 02/17/2025
File details come from the government source that posted it. Updated .