AE601 - DOOR SCHEDULE AND DETAILS.pdf
PDF 91 KB Posted
- Solicitation number
- W50S8T25BA011
- Issued by
-
Department of the Army National Guard
About this file
This is a detailed door schedule and architectural details drawing showing specifications for doors, frames, and interior windows for a building renovation project at Will Rogers Air National Guard Base in Oklahoma City. The drawing includes a comprehensive door schedule listing over 50 doors with specifications for size, type (wood, steel, aluminum), fire ratings, STC ratings, frame types, and hardware requirements.
Key technical details include specifications for multiple door types including wood interior (WFI), wood fire-rated (WFR), steel interior (SFI), steel fire-rated (SFR), steel exterior (SFX), and aluminum exterior/interior (AFGX/AFGI) doors. The drawing provides detailed frame types (S2 and S4 steel frames), architectural door types, interior window types, and typical drywall expansion joint details. Notable specialized requirements include STC-55 rated doors, 45-minute fire rated doors, and doors with Cypher X-10 locks for secured areas. The drawing is dated September 12, 2024 and was prepared by Frankfurt-Short-Bruza Associates for project number 2020-484-00.
View the file
Other files
Show all 50
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S2 STEEL
D O
O R
H
EI
G H
T 2"
2" 2"DOOR WIDTH
GWB CONTROL JOINS
CENTERED ON DOOR
FRAME ON BOTH SIDES
OF ALL INT DOORS TO
TRUE TOP OF WALL
S4 STEEL
D O
O R
H
EI
G H
T
2" 2"DOOR WIDTH
D O
O R
H
EI
G H
T
DOOR WIDTH
WFI WOOD, INT
WFR WOOD, INT, FIRE RTD
SFI STEEL, INT
SFR STEEL, INT, FIRE RTD
SFX STEEL, EXTERIOR
D O
O R
H
EI
G H
T
DOOR WIDTH
AFGX ALUM, EXT
AFGI ALUM, INT
GLAZING
REF DOOR
SCHEDULE
FOR TYPE
IN2
• HOLLOW METAL (HM)
• STC-50 WELDED FRAME
IN1
• HOLLOW METAL (HM)
• STC-50 WELDED FRAME
2"
3' -8
2"
3' -0
2"
17'-8"
2"
18'-0"
2"
3' -4
2"
3' -6
4' -0
3' -8
2"
2'-10"
2"
3'-2"
EQ EQ EQ EQ EQ
2"
3' -1
0"
2"
2' -1
0"
4' -2
2"
3'-8"
2"
4'-0"
IN3
EQ 2" EQ
IN4
ABA COMPLIANT
SOLID SURFACE SILL
EX4
NOTES:
1. HIGH-PERFORMANCE ONE-WAY VISION GLASS
2. 1/4" TEMPERED GLASS
3. 1" INSULATION GLASS PER SPECIFICATION
SECTION 08 81 00
FIELD VERIFY
2" F.V. 2" 6'-0" 2" F.V. 2"
F.
V.
6' -8
4"
1/2"AIR GAP COLD-FORMED
METAL
FRAMING
5/8" TYPE-X
GYP BD.
2-LAYERS 5/8"
TYPE-X GYP BD.
MTL CONTROL
JOINT - BOTH SIDES
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
Frankfurt-Short-Bruza Associates,P.C.
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
2020-484-00
NDM
Re pa ir/ Co nv er t S qu ad O ps Ok lah om a C ity
, O K
NG
BJ
V/
OK
A
NG
PN: YZEU142025
C :\U sers\bkg\D o cum ents\M y R evit\048400_AR C
H
_BG
allagher5SB23.rvt
2/17/2025 3:47: 40 PM
12 SEPTEMBER 2024
DOOR SCHEDULE AND DETAILS
AE601
MJT
BKG
JO
DOOR SCHEDULE
MARK
DOOR
FIRE
RATING STC
FRAME
HARDWARE
# NOTES
SIZE DOOR
TYPE TYPE
DETAIL
WD HGT THK HEAD JAMB SILL
100A 5'-0" 7'-10 3/4" 2" (2) AFGX -- EXISTING
COND
B3 &
B4/AE501
A1/AE502 1.0 NEW ALUM
STOREFRONT
100B 5'-0" 7'-10 3/4" 2" (2)AFGI -- -- EXISTING
COND
A1 &
B2/AE501
2.0 NEW ALUM
STOREFRONT
102A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
104A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
105A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
106A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
107A 3'-0" 7'-10 3/4" 1 3/4" -- -- -- 13.0 EXISTING TO
REMAIN
107B 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 14.0
110A 3'-10" 7'-2" 1 3/4" SFR 45 MIN 55
STC
S4 D4/AE502
SIM
C3/AE502
SIM
B3/AE502 15.0 NOTE 1; CYPHER
X-10 LOCK;
REUSE DOOR AS
DOOR 110B
110B 3'-10" 7'-2" 1 3/4" SFR 45 MIN 55
STC
S4 D3/AE502
SIM
C2/AE502
SIM
B3/AE502 15.0 PREVIOUSLY
DOOR 110A;
CYPHER X-10
LOCK
111A 3'-6" 6'-6" 2" -- 45 MIN 55
STC
-- 14.0 EXISTING TO
REMAIN; NOTE 2
112A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
114A 3'-0" 7'-2" 1 3/4" SFR 45 MIN 55
STC
-- 14.0 EXISTING TO
REMAIN; NOTE 2
115A 3'-0" 7'-0" 1 3/4" WFR 45 MIN S2 D2/AE502 C1/AE502 14.0
116A 3'-0" 7'-0" 1 3/4" WFR 45 MIN S2 D2/AE502 C1/AE502 14.0
117A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 11.0
118A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
118B 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
120A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 8.0
121A 5'-0" 7'-0" 1 3/4" -- -- 10.0 EXISTING TO
REMAIN
122A 3'-0" 7'-0" 1 3/4" -- 45 MIN 11.0 EXISTING TO
REMAIN
123A 3'-0" 7'-0" 1 3/4" -- -- 9.0 EXISTING TO
REMAIN
124A 3'-6" 7'-0" 1 3/4" -- -- 13.0 EXISTING TO
REMAIN
124B 3'-6" 7'-0" 1 3/4" -- -- 14.0 EXISTING TO
REMAIN
125A 11'-0" 12'-0" 1 3/4" -- -- 19.0 EXISTING TO
REMAIN
125B 4'-0" 7'-2" 1 3/4" SFX -- S4 C5/AE502 C4/AE502 5.0
126.1A 3'-0" 7'-0" 1 3/4" WFR 45 MIN S2 D2/AE502 C1/AE502 11.0
126A 3'-0" 7'-0" 1 3/4" SFI -- 5.0
127A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 14.0
SCALE: NTS
FRAME TYPES
SCALE: NTS
ARCHITECTURAL DOOR TYPES
DOOR SCHEDULE
MARK
DOOR
FIRE
RATING STC
FRAME
HARDWARE
# NOTES
SIZE DOOR
TYPE TYPE
DETAIL
WD HGT THK HEAD JAMB SILL
128A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 7.0
129A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 15.0
129B 3'-0" 7'-0" 1 3/4" WFI -- 55
STC
S2 D4/AE502 C3/AE502 B3/AE502 16.0 CYPER X-10
LOCK
130A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 7.0
132A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
133A 3'-0" 7'-0" 1 3/4" WFI -- 55
STC
S2 D4/AE502 C3/AE502 B3/AE502 18.0 EGRESS ONLY
135A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
136A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
137A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
138A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 14.0
140A 3'-0" 7'-0" 1 3/4" -- -- 13.0 EXISTING TO
REMAIN
140B 3'-0" 7'-0" 1 3/4" -- -- 14.0 EXISTING TO
REMAIN
141A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 14.0
141B 3'-0" 7'-0" 1 3/4" -- 14.0 EXISTING TO
REMAIN
141C 3'-0" 7'-0" 1 3/4" -- -- 13.0 EXISTING TO
REMAIN
143A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
144A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 14.0
145A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 6.0
146A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 11.0
147A 3'-0" 7'-0" 1 3/4" WFR 45 MIN S2 D2/AE502
SIM
C1/AE502
SIM
11.0
148A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
148B 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
149A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
150A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
151A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
152A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
153A 3'-0" 7'-0" 1 3/4" -- -- 13.0 EXISTING TO
REMAIN
153B 3'-0" 7'-0" 1 3/4" -- -- 14.0 EXISTING TO
REMAIN
154A 5'-0" 7'-0" 1 3/4" -- -- 10.0 EXISTING TO
REMAIN
155A 3'-0" 7'-0" 1 3/4" -- -- 11.0 EXISTING TO
REMAIN
157A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 8.0
159A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
160A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
161A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
162A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 5.0
163A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 14.0
164A 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 14.0
165A 3'-0" 7'-0" 1 3/4" WFI -- 55
STC
S2 D4/AE502 C3/AE502 B3/AE502 15.0 CYPHER X-10
LOCK
166A 3'-5" 7'-2" 1 3/4" SFR 55
STC
14.0
167A 3'-0" 7'-10 3/4" 1 3/4" -- -- 17.0 EXISTING TO
REMAIN
167B 3'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 17.0
168A 3'-0" 7'-0" 1 3/4" WFI -- 55
STC
D4/AE502 C3/AE502 5.0
169A 3'-0" 7'-0" 1 3/4" WFI -- 55
STC
D4/AE502 C3/AE502 14.0 CYPHER X-10
LOCK
170A 3'-0" 7'-0" 1 3/4" WFR 45 MIN 14.0 EXISTING TO
REMAIN; NOTE 2
171A 5'-0" 7'-10 3/4" 2" (2) AFGX -- -- EXISTING
COND
B3 &
B4/AE501
A1/AE502 3.0 NEW ALUM
STOREFRONT
171B 5'-0" 7'-10 3/4" 2" (2)AFGI -- -- EXISTING
COND
B1 &
B2/AE501
4.0 NEW ALUM
STOREFRONT
172A 6'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 12.0
173A 6'-0" 7'-0" 1 3/4" WFI -- S2 D2/AE502 C1/AE502 12.0
174A 3'-0" 7'-0" 1 3/4" WFI 45 MIN 55
STC
S2 D3/AE502 C2/AE502 B3/AE502 5.0
174B 3'-0" 7'-0" 1 3/4" WFI 45 MIN 55
STC
S2 D3/AE502 C2/AE502 B3/AE502 5.0
175 6'-0" 7'-0" 1 3/4" (2)SFX -- S4 B5/AE502 B4/AE502 A2/AE502 10.0
SCALE: NTS
INTERIOR WINDOW TYPES
DOOR NOTES:
1. DOOR IS TO BE LOCATED OUTSIDE OF WORK AREA DURING WORK IN COMMS AREA
(ROOMS 110, 111, AND 114) RELOCATE INTO POSITION OF DOOR 110B WHEN WORK IN
THESE AREAS IS COMPLETED. SEE ENLARGED PLAN DETAIL A4/AE102.
2. EXISTING DOOR IS TO REMAIN, UNLESS IT DOES NOT MEET A 45 MIN RATING.
CONTRACTOR IS TO CHECK AND VERIFY DOOR RATING. IF DOOR DOES NOT MEET 45 MIN
CRITERIA A NEW STC-55 45 MINUTE RATED DOOR MUST BE PROVIDED.
SCALE: 6" = 1'-0"
TYP. DRYWALL EXP. JOINTB2
0 1" 2" 4"
6" = 1'-0"
D1
C1
A1
2 ADDENDUM 01 02/17/2025
File details come from the government source that posted it. Updated .