AE602 - OLI 1 - EXTERIOR WINDOW FRAMES.pdf

PDF 58 KB Posted

Attached to
137th SOW - Building 1040 Repair / Renovation Project
Solicitation number
W50S8T25BA011
Issued by

About this file

This is an architectural drawing showing specifications for exterior window frames (labeled as OLI #1) for a building renovation project at Will Rogers Air National Guard Base. The drawing details five aluminum storefront window configurations (labeled A through E) with precise measurements and dimensions.

The frames are labeled as "ALUMINUM STOREFRONT SYSTEM" with varying widths ranging from 10'-8" to 16'-0" and consistent heights of approximately 5'-0". The specifications include 1" insulation glass per specification section 08 81 00, and one-way window film requirements as referenced on architectural drawing AE201. The document includes a note requiring field verification of existing frame sizes and contractor verification of anchor/support locations prior to installation. The drawing is dated September 12, 2024, with Addendum 01 issued on February 17, 2025, and was prepared by Frankfurt-Short-Bruza Associates, P.C. for the National Guard Bureau Joint/Oklahoma Air National Guard project number YZEU142025.

View the file

Other files

File Type Posted
Abstract (Final).pdf PDF
Amendment 3 Attachment 1 - Bldg 1040 Reno Questions and Answers.docx DOCX document
Solicitation Amendment 3 W50S8T25BA0110003.pdf PDF
NEW 6 Mar 25 Oklahoma NGB-WRWA - 100 CD Set Part 1.pdf PDF
NEW 6 Mar 25 Oklahoma NGB-WRWA - 100 CD Set Part 2.pdf PDF
Amendment 2 Attachment 2 - 09 72 00.pdf PDF
Amendment 2 Attachment 5 - IN600 - INTERIORS MATERIALS LEGEND.pdf PDF
Amendment 2 Attachment 3 - A-002 - PARTITION TYPES.pdf PDF
Amendment 2 Attachment 6 - Bldg 1040 Reno Questions and Answers.xlsx XLSX spreadsheet
Amendment 2 Attachment 1 - Addendum 02 Narrative.docx DOCX document
Solicitation Amendment 2 W50S8T25BA0110002.pdf PDF
Amendment 2 Attachment 4 - 08 11 16.pdf PDF
06 20 00.pdf PDF
21 13 13.pdf PDF
IN101 - FLOOR FINISH PLAN - SECTOR A.pdf PDF
Bldg 1040 Reno Questions and Answers - FSB and GOV Reponses.xlsx XLSX spreadsheet
EL101 - ELECTRICAL INTERIOR LIGHTING PLAN - SECTOR A.pdf PDF
AE102 - FLOOR PLAN - SECTOR A.pdf PDF
AE502 - DETAILS.pdf PDF
AE403 - ENLARGED PLANS.pdf PDF
10 21 13.pdf PDF
10 51 13.pdf PDF
08 41 13.pdf PDF
AE103 - FLOOR PLAN - SECTOR B.pdf PDF
08 81 00.pdf PDF
AE411 - INTERIOR ELEVATIONS.pdf PDF
AE402 - ENLARGED PLANS.pdf PDF
AE601 - DOOR SCHEDULE AND DETAILS.pdf PDF
26 05 73.pdf PDF
08 11 16.pdf PDF
Addendum 01 Narrative.docx DOCX document
08 71 00.pdf PDF
IN102 - FLOOR FINISH PLAN - SECTOR B.pdf PDF
Solicitation Amendment 1 W50S8T25BA0110001 SF 30.pdf PDF
06 41 16.00 10.pdf PDF
AE201 - BUILDING ELEVATIONS.pdf PDF
TABLE OF CONTENTS.pdf PDF
A-002 - PARTITION TYPES.pdf PDF
01 45 35.pdf PDF
FA601 - FIRE ALARM - MASS NOTIFICATION RISER DIAGRAM.pdf PDF
AE151 - REFLECTED CEILING PLAN - SECTOR A.pdf PDF
AE600 - ROOM FINISH SCHEDULE.pdf PDF
10 51 16.pdf PDF
30 Jan 25 Site Visit Sign In Sheet.pdf PDF
BLDG 1040 Renovation Site Visit Slides 30 January 25.pptx PPTX presentation
ATTACHMENT 3 - 2024.09.12_OK-ANG_SQUADOPS B1040_TYPE B3_SPECIFICATIONS VOL. 2.pdf PDF
Solicitation - W50S8T25BA011.pdf PDF
ATTACHMENT 2 - 2024.09.12_OK-ANG_SQUADOPS B1040_TYPE B3_SPECIFICATIONS VOL. 1.pdf PDF
Bidders Checklist.docx DOCX document
ATTACHMENT 1 - 2024.09.12_OK-ANG_SQUADOPS B1040_TYPE B3_DRAWINGS.pdf PDF
Show all 50

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EX1

• ALUMINUM

STOREFRONT

SYSTEM

2"

4' -8

2"

3' -6

5' -0

2"

EQ. EQ. EQ. EQ.

2"

14'-8"

3 3 3 3

2"

4' -8

2"

3' -6

5' -0

2"

EQ. EQ. EQ.

2"

11'-0 1/2"

3 3 3

2"

4' -8

2"

3' -6

5' -0

2"

EQ. EQ. EQ.

2"

12'-8"

3 3 3

EX1

• ALUMINUM

STOREFRONT

SYSTEM

2"

4' -8

2"

3' -6

5' -0

2"

EQ. EQ. EQ. EQ. EQ.

2"

16'-0"

4 4 4 4

2"

4' -8

2"

3' -6

5' -0

2"

EQ. EQ. EQ.

2"

10'-8"

3 3 3 4

A

• ALUM STOREFRONT

B C

D E

• ALUM STOREFRONT • ALUM STOREFRONT

• ALUM STOREFRONT • ALUM STOREFRONT

NOTE: FIELD VERIFY THE SIZES OF EXISTING FRAMES TO BE

REPLACED. CONTRACTOR IS TO VERIFY CONDITIONS AT

ANCHOR AND SUPPORT LOCATION POINTS FOR NEW

STOREFRONT FRAMES PRIOR TO INSTALLATION. IF

CONDITIONS ARE NOT SUITABLE FOR THE NEW FRAMES, THE

CONTRACTOR IS TO NOTIFY THE BASE CONTACT OFFICER OR

THE ARCHITECT OF THE NATURE OF THE DEFICIENCY.

NOT USED

2 2 2

NOTES:

3. 1" INSULATION GLASS PER

SPECIFICATION SECTION 08 81 00.

NOTE: REFER ARCHITECTURAL

DRAWINGS SHEET AE201 FOR

ONE-WAY WINDOW FILM. WINDOW

FILM IS NOT CONTINGENT ON OLI

#1 AND IS A REQUIREMENT ON

THE PROJECT AT LOCATIONS

INDICATED.

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

Frankfurt-Short-Bruza Associates,P.C.

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

C

B

A

D

C

B

A

54321

2020-484-00

NDM

Re pa ir/ Co nv er t S qu ad O ps Ok lah om a C ity

, O K

NG

BJ

V/

OK

A

NG

PN: YZEU142025

C :\U sers\bkg\D o cum ents\M y R evit\048400_AR C

H

_BG

allagher5SB23.rvt

2/17/2025 3:47: 41 PM

12 SEPTEMBER 2024

OLI #1 - EXTERIOR WINDOW

FRAMES

AE602

MJT

BKG

JO

SCALE: 1/2" = 1'-0"

OLI #1 - EXTERIOR WINDOW TYPES

0 1' 2' 4'

1/2" = 1'-0"

B1

2 ADDENDUM 01 02/17/2025

File details come from the government source that posted it. Updated .