This is a technical specification document (Section 10 51 16) detailing requirements for cell phone lockers as part of Building 1040 repair/renovation at the 137th SOW Oklahoma Air National Guard Base.

The specification calls for heavy-duty aluminum cell phone lockers with durable powder-coated finish, requiring one recessed unit and two surface-mounted units with front access panels. Each unit must be 5 doors high, 24 inches wide, 29-3/4 inches tall, with an overall depth of 8-3/4 inches and compartment depth of 8 inches. Units must feature resettable combination locks with master control key, aluminum finish, clear plastic card holders (2 x 5/8 inches), and built-in continuous hinges. The manufacturer must be ISO 9001:2015 certified and provide a 3-year warranty. Installation requirements include proper surface preparation, anchoring to wall studs, and protection of units until project completion.

View the file

Other files

File Type Posted
Abstract (Final).pdf PDF
Amendment 3 Attachment 1 - Bldg 1040 Reno Questions and Answers.docx DOCX document
Solicitation Amendment 3 W50S8T25BA0110003.pdf PDF
NEW 6 Mar 25 Oklahoma NGB-WRWA - 100 CD Set Part 1.pdf PDF
NEW 6 Mar 25 Oklahoma NGB-WRWA - 100 CD Set Part 2.pdf PDF
Amendment 2 Attachment 2 - 09 72 00.pdf PDF
Amendment 2 Attachment 5 - IN600 - INTERIORS MATERIALS LEGEND.pdf PDF
Amendment 2 Attachment 3 - A-002 - PARTITION TYPES.pdf PDF
Amendment 2 Attachment 6 - Bldg 1040 Reno Questions and Answers.xlsx XLSX spreadsheet
Amendment 2 Attachment 1 - Addendum 02 Narrative.docx DOCX document
Solicitation Amendment 2 W50S8T25BA0110002.pdf PDF
Amendment 2 Attachment 4 - 08 11 16.pdf PDF
06 20 00.pdf PDF
21 13 13.pdf PDF
IN101 - FLOOR FINISH PLAN - SECTOR A.pdf PDF
Bldg 1040 Reno Questions and Answers - FSB and GOV Reponses.xlsx XLSX spreadsheet
EL101 - ELECTRICAL INTERIOR LIGHTING PLAN - SECTOR A.pdf PDF
AE102 - FLOOR PLAN - SECTOR A.pdf PDF
AE502 - DETAILS.pdf PDF
AE403 - ENLARGED PLANS.pdf PDF
10 21 13.pdf PDF
10 51 13.pdf PDF
08 41 13.pdf PDF
AE103 - FLOOR PLAN - SECTOR B.pdf PDF
08 81 00.pdf PDF
AE411 - INTERIOR ELEVATIONS.pdf PDF
AE402 - ENLARGED PLANS.pdf PDF
AE601 - DOOR SCHEDULE AND DETAILS.pdf PDF
26 05 73.pdf PDF
08 11 16.pdf PDF
AE602 - OLI 1 - EXTERIOR WINDOW FRAMES.pdf PDF
Addendum 01 Narrative.docx DOCX document
08 71 00.pdf PDF
IN102 - FLOOR FINISH PLAN - SECTOR B.pdf PDF
Solicitation Amendment 1 W50S8T25BA0110001 SF 30.pdf PDF
06 41 16.00 10.pdf PDF
AE201 - BUILDING ELEVATIONS.pdf PDF
TABLE OF CONTENTS.pdf PDF
A-002 - PARTITION TYPES.pdf PDF
01 45 35.pdf PDF
FA601 - FIRE ALARM - MASS NOTIFICATION RISER DIAGRAM.pdf PDF
AE151 - REFLECTED CEILING PLAN - SECTOR A.pdf PDF
AE600 - ROOM FINISH SCHEDULE.pdf PDF
30 Jan 25 Site Visit Sign In Sheet.pdf PDF
BLDG 1040 Renovation Site Visit Slides 30 January 25.pptx PPTX presentation
ATTACHMENT 3 - 2024.09.12_OK-ANG_SQUADOPS B1040_TYPE B3_SPECIFICATIONS VOL. 2.pdf PDF
Solicitation - W50S8T25BA011.pdf PDF
ATTACHMENT 2 - 2024.09.12_OK-ANG_SQUADOPS B1040_TYPE B3_SPECIFICATIONS VOL. 1.pdf PDF
Bidders Checklist.docx DOCX document
ATTACHMENT 1 - 2024.09.12_OK-ANG_SQUADOPS B1040_TYPE B3_DRAWINGS.pdf PDF
Show all 50

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

137TH SOW OKLAHOMA ANG B- 3 100% REPAI R BUI LDI NG 1040

OKLAHOMA CI TY, OK 12 SEPTEMBER, 2024

SECTI ON 10 51 16

CELL PHONE LOCKERS

03/ 22

PART 1 GENERAL

1. 1 REFERENCES

The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o wi t hi n t he t ext by t he basi c desi gnat i on onl y.

1. 2 SUBMI TTALS

Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;

submi t t al s not havi ng a " G" desi gnat i on ar e f or Cont r act or Qual i t y Cont r ol appr oval . Submi t t al s wi t h an " S" ar e f or i ncl usi on i nt he Sust ai nabi l i t y eNot ebook, i n cof or mance wi t h Sect i on 01 33 29 SUSTAI NABI LI TY REPORTI NG.

Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00 SUBMI TTAL

PROCEDURES:

SD- 02 Shop Dr awi ngs

Mat er i al s; G

SD- 03 Pr oduct Dat a

Manuf act ur ed Uni t s; G

1. 3 QUALI TY ASSURANCE

Manuf act ur er Qual i f i cat i ons: Manuf act ur er shal l have a Qual i t y Syst em i n pl ace t o ensur e and be abl e t o subst ant i at e t hat manuf act ur ed uni t s conf or m t o r equi r ement s and mat ch t he appr oved desi gn and must be I SO 9001: 2015 cer t i f i ed.

1. 4 DELI VERY, STORAGE, AND HANDLI NG

a. St or e pr oduct s i n manuf act ur er ' s unopened packagi ng unt i l r eady f or i nst al l at i on.

b. Cel l phone l ocker component s ar e shi pped assembl ed. Al l f i ni shes shal l be pr ot ect ed f r om soi l i ng and damage dur i ng handl i ng.

1. 5 WARRANTY

Manuf act ur er ' s st andar d war r ant y t o r epai r or r epl ace component s of cel l phone l ocker pr oduct s t hat f ai l i n mat er i al s or wor kmanshi p wi t hi n 3 year s f r om dat e of subst ant i al compl et i on.

PART 2 PRODUCTS

2. 1 SYSTEM DESCRI PTI ON

Cel l phone l ocker s wi t h f r ont access panel .

SECTI ON 10 51 16 Page 1

Gallagher, Brad K.

Text Box

ADDENDUM #1 02-17-2025

Gallagher, Brad K.

Cloud

2. 2 MATERI ALS

Const r uct ed ent i r el y of heavy dut y al umi num; dur abl e powder coat ed f i ni sh.

2. 3 MANUFACTURED UNI TS

Recessed uni t s ( quant i t y 1) or Sur f ace Mount ed uni t s ( quant i t y 2) per dr awi ngs. Cel l Phone Locker s wi t h Fr ont Access Panel s.

1. 5 door hi gh uni t s.

b. Uni t Wi dt h: 24 i nches.

1. .

c. Uni t Hei ght : 29- 3/ 4 i nches.

d. Uni t Dept h

1. Over al l Dept h: 8- 3/ 4 i nches.

2. Compar t ment Dept h: 8 i nches.

e. Lock Type: Reset t abl e combi nat i on l ocks wi t h Mast er cont r ol key.

f . Uni t Col or : Al umi num.

g. Car d Hol der : Cl ear pl ast i c, 2 x 5/ 8 i nches.

h. Hi nges: Bui l t - i n cont i nuous.

PART 3 EXECUTI ON

3. 1 EXAMI NATI ON

a. Do not begi n i nst al l at i on unt i l subst r at es have been pr oper l y pr epar ed.

b. I f subst r at e pr epar at i on i s t he r esponsi bi l i t y of anot her i nst al l er , not i f y Ar chi t ect of unsat i sf act or y pr epar at i on bef or e pr oceedi ng.

3. 2 PREPARATI ON

Cl ean sur f aces t hor oughl y pr i or t o i nst al l at i on. Cl ean sur f aces wi t h mi l d di sh det er gent . Do not use har sh abr asi ve c l eaner s. Lubr i cat e l ocks wi t h gr aphi t e t ype l ubr i cant s onl y.

3. 3 I NSTALLATI ON

a. I nst al l i n accor dance wi t h manuf act ur er ' s i nst al l at i on i nst r uct i ons.

b. Anchor t he uni t s t o t he wal l st uds t hr ough t he l ocker back.

3. 4 PROTECTI ON

a. Pr ot ect i nst al l ed pr oduct s unt i l compl et i on of pr oj ect .

SECTI ON 10 51 16 Page 2

Gallagher, Brad K.

Rectangle

Gallagher, Brad K.

Cloud

Gallagher, Brad K.

Text Box

ADDENDUM #1 02-17-2025

b. Touch- up, r epai r or r epl ace damaged pr oduct s bef or e subst ant i al compl et i on.

- - End of Sect i on - -

SECTI ON 10 51 16 Page 3

10 51 16 - CELL PHONE LOCKERS
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 QUALITY ASSURANCE
1.4 DELIVERY, STORAGE, AND HANDLING
1.5 WARRANTY
PART 2 PRODUCTS
2.1 SYSTEM DESCRIPTION
2.2 MATERIALS
2.3 MANUFACTURED UNITS
PART 3 EXECUTION
3.1 EXAMINATION
3.2 PREPARATION
3.3 INSTALLATION
3.4 PROTECTION