PDX 2026-513 (06) A0.01.pdf
PDF 354 KB Posted
- Solicitation number
- 145968
- Issued by
- Multnomah County, Oregon
About this file
This is an architectural drawing legend and symbols sheet for the Portland International Airport Customs and Border Protection Improvements - Phase 2 project located in Oregon. The document serves as a reference guide for interpreting construction drawings and specifications, providing standardized architectural symbols, abbreviations, and notations used throughout the project documentation. The sheet includes comprehensive listings of common architectural abbreviations (such as A.C. for air conditioning, CMU for concrete masonry unit, and HVAC for heating, ventilation and air conditioning), material symbols depicting elements like slab on grade, steel panels, insulation, and gypsum board, and graphic representations for detail references, section/elevation markers, door tags, and HVAC unit identifications. The legend also contains a floor-ceiling-structure designation key that defines fire-rating and partition configurations, including non-rated wall specifications and framing size designations ranging from 1 5/8 inches to 8 inches. The drawing was prepared in September 2026 and designed by Jay Ostlund, with drawings by D. Calem and checked by A. Laskey.
The document is fundamentally a reference tool rather than a procurement instrument and contains no pricing information, contract terms, bid due dates, or award details. The sheet explicitly notes that some abbreviations and symbols included may not appear in all project drawings, and it is intended for reference only with drawings scaled at 50 percent reduction when printed on 11" x 17" sheets. The document serves as standard documentation for the Portland International Airport construction project and does not contain financial obligations, funding sources, or contracting requirements beyond its function as a technical reference guide for construction professionals interpreting project drawings.
View the file
Other files
Show 40 more
Latest 50 of 88 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ARCHITECTURAL DRAWING SYMBOLS:
SYMBOL DESCRIPTION
X'-X"
A
MATERIAL SYMBOLS:
D0000
A-0
3A-01
A-0
AA 000
ARCHITECTURAL ABBREVIATIONS:
ABBR. ABBREVIATION
A.C. AIR CONDITIONING
A.C.T. ACOUSTICAL CEILING TILE
ADJ. ADJUSTABLE
ALT. ALTERNATE
A..T. ACOUSTICAL CEILING TILE
A.F.F. ABOVE FINISHED FLOOR
B.O. BOTTOM
BD. BOARD
BLDG. BUILDING
BLKG. BLOCKING
B.O. BOTTOM OF
CLG. CEILING
CMU CONCRETE MASONRY UNIT
CNTRL CONTROL
CONC. CONCRETE
CLG. CONTINUOUS
CPT. CARPET
C.T. CERAMIC TILE
DBL. DOUBLE
DET. DETAIL
DIAG. DIAGONAL
DIA. DIAMETER
DIM. DIMENSION
DR. DOOR
DWG. DRAWING
(E) EXISTING
E. EAST
EA. EACH
ELEC. ELECTRICAL
EQ. EQUAL
EQUIP. EQUIPMENT
EXIST. EXISTING
EXT. EXTERIOR
F.D. FLOOR DRAIN
F.E.C. FIRE EXTINGUISHER CABINET
FF&E FURNITURE, FIXTURES,
& EQUIPMENT
FIN. FINISH
F.O.B. FACE OF BRICK
F.O.C. FACE OF CONCRETE
F.O.F. FACE OF FINISH
F.O.I.O. FURNISHED BY OWNER,
INSTALLED BY OWNER
F.O.I.C. FURNISHED BY OWNER
INSTALLED BY CONTRACTOR
F.O.S. FACE OF STUD
FRP FIBERGLASS REINFORCED PANEL
FT. FOOT OR FEET
GA. GAUGE
GALV. GALVANIZED
GL. GLASS
GYP. GYPSUM
G.W.B. GYPSUM WALL BOARD
H.B. HOSE BIB
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
HT. HEIGHT
HVAC HEATING, VENTILATION
AND AIR CONDITIONING
I.D. INSIDE DIAMETER
INFO. INFORMATION
INT. INTERIOR
JAN. JANITOR
LAV. LAVATORY
LT. LIGHT
MANF. MANUFACTURER
MATL MATERIAL
MAX. MAXIMUM
MDF MEDIUM DENSITY FIBERBOARD
MAY. MECHANICAL
MIN. MINIMUM
MTL. METAL
(N) NEW
N. NORTH
N.I.C. NOT IN CONTRACT
N.T.S. NOT TO SCALE
OA. OVERALL
O.C. ON CENTER
OPG. OPENING
OPP. OPPOSITE
P. PAINT
PL. PLASTIC LAMINATE
PWD. PLYWOOD
PT. POINT
P.T. PRESSURE TREATED
R.B. RUBBER BASE
RD. ROOF DRAIN
REF. REFERENCE
REQ. REQUIRED
REQS. REQUIREMENTS
REV. REVISED
R.O. ROUGH OPENING
RM. ROOM
S. SOUTH
SECT. SECTION
S.E.G. SILICONE EDGE GRAPHICS
SHT. SHEET
SIM. SIMILAR
SPEC. SPECIFICATION
SQ. SQUARE
S.S. STAINLESS STEEL
STD. STANDARD
STL. STEEL
STRUCT. STRUCTURAL
T.G. TEMPERED GLASS
T.O.S. TOP OF SLAB
T.O.W. TOP OF WALL
T.P. TOILET PAPER
TYP. TYPICAL
U.O.N. UNLESS OTHERWISE NOTED
V.B. VAPOR BARRIER
V.C.T. VINYL COMPOSITION TILE
VERT. VERTICAL
V.I.F. VERIFY IN FIELD
W. WEST
WD. WOOD
W/ WITH
W/O WITHOUT
W.R.G.B. WATER RESISTANT
GYPSUM BOARD
WT. WEIGHT
(X) DEMOLISH
DESCRIPTIONSYMBOL
SLAB ON GRADE SUBFILL
CONCRETE
STAINLESS STEEL WALL PANELS
STEEL / METAL
ROUGH CARPENTRY (CONTINUOUS)
ROUGH CARPENTRY (BLOCKING)
FINISH CARPENTRY
PLYWOOD
BATT INSULATION
RIGID INSULATION
GYPSUM BOARD
MORTAR - GROUT
DETAIL REFERENCE
SECTION/ELEVATION REFERENCE
INTERIOR ELEVATION REFERENCE
DOOR
DIMENSION LINE - FACE OF FINISH -
U.O.N.
GRID IDENTIFICATION
WALL TYPE REFERENCE
CEILING TYPE REFERENCE
HANDRAIL BRACKET TYPE REFERENCE
KEY NOTE
REVISION REFERENCE
DOOR TAG
SIGN TAG
HVAC UNIT TAG
FIRE EXTINGUISHER
NOTE(S):
1. THIS IS A STANDARD LEGEND SHEET. SOME ABBREVIATIONS AND SYMBOLS
APPEAR ON THIS SHEET THAT DO NOT APPEAR IN THE DRAWINGS.
VVR-T-000
XX
8/27/2026 lig ht da rk gr ay bl ac k
DESIGN NUMBER PROJECT NUMBER
2"
G R
AP
H
IC
S
C
AL
E-
FO
R R
EF
ER
EN
C
E O
N
LY
gr ay
2:25:28 PM x:\pdx cbp 2026\d-drawings\00 current\a0.01.dwg DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 11" x 17"
DESIGNED BY
DRAWN BY
CHECKED BY
DATE
SHEET NO.
SUBMITTED BY
DRAWING NO.
1/ 4"
1/
2" 1"
BY REVISIONS APP
IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING
NO.DATE BY REVISIONS APPNO.
TYPE:
DISC. SHT. NO.
C
AN
Y O
U S
EE
T
H E
AI
R
PL
AN
ES
T H
E
AD
JA
C
EN
T
SA
M
PL
ES
S H
O W
T H
R
EE
D
IF
FE
R
EN
T
LE
VE
LS
O
F
SH
AD
IN
G
SE
TT
IN
G
S
FO
R V
IE
W
IN
G
A N
D P
R
IN
TI
N
G D
R
AW
IN
G
C O
N
TE
N T
AR
E
O
PT
IM
IZ
ED
W
H
EN
A
LL
T H
R
EE
P
LA
N
ES
A R
E
VI
SI
BL
E.
T
H
IS
G U
ID
AN
C E
IS
P
R O
VI
D
ED
F
O R
R
EF
ER
EN
C E
O N
LY
D R
AW
IN
G S
C
AL
E
IS
R E
D U
C E
D
0% W
H
EN
S H
EE
T
SI
ZE
IS
1" x
7"
DATE
PORTLAND INTERNATIONAL AIRPORT
CUSTOMS AND BORDER PROTECTION IMPROVEMENTS - PHASE 2
ABBREVIATIONS, SYMBOLS, AND NOTES
JAY OSTLUND
D. CALEM
A. LASKEY
D. CALEM
SEPTEMBER 2026
6 CD
PDX 2026-513 A0.012025D042 103146
D/FCBA
FLOOR
CEILING
STRUCTURE
A NON-RATED - TO UNDERSIDE OF EXISTING DUCT WORK.
PROVIDE BRACING TO STRUCTURE.
B NON-RATED - TO UNDERSIDE OF FINISHED CEILING.
C NON-RATED - EXTEND FRAMING AND FINISH TO 6 INCHES ABOVE
CEILING. BRACE FRAMING TO ADJACENT CMU OR CONCRETE
WALLS OR TO STRUCTURE ABOVE.
D NON-RATED, UNLESS NOTED OTHERWISE - TO UNDERSIDE OF
STRUCTURE ABOVE. PROVIDE DEFLECTION HEADS PER DETAILS.
E NON-RATED - PARTIAL HEIGHT WALL.
F FIRE-RATED - TO UNDERSIDE OF FINISHED CEILING.
FIRE-RATING/PARTITION DESIGNATION:
E
2 1 5/8" 3 2 1/2" 4 3 5/8" 6 6" 8 8"
M MATCH EXISTING
FRAMING SIZE
DESIGNATIONFIRE-RATING/
PARTITION HEIGHT
DESIGNATION
PARTITION
CONFIGURATION
PARTITION TYPE PLAN SYMBOL:
FRAMING SIZE DESIGNATION:
USE MOISTURE
RESISTANT GYP. BD.
MR
A 4 P1
FLOOR PLAN SERIES NAMING KEY:
A1.11
SECTOR DESIGNATION
PLAN TYPE DESIGNATION
DRAWING TYPE: E.G., DEMO/PLAN/WASTE/UTILITIES
DISCIPLINE: ARCHITECTURAL, MECHANICAL,
PLUMBING, ELECTRICAL, TECHNOLOGY, SIGNAGE
A 4 P1
G
X
| Sheets and Views |
| A0.01 |
| 2026-08-27T14:27:12-0700 | |
| Dave Calem |
File details come from the government source that posted it. Updated .