9-14 - A1-2 - SECOND FLOOR DEMOLITION AND NEW WORK PLANS.pdf
PDF 317 KB Posted
- Solicitation number
- RFP260305
- Issued by
- Hart County, Kentucky
About this file
This is an architectural drawing set for second floor demolition and new work plans prepared by the Commonwealth of Kentucky's Department for Facilities Management, Division of Engineering, for the Gateway Urban Campus Classroom Center located at 438-440 Scott Street, Covington, Kentucky. The project involves comprehensive demolition and renovation of the second floor, including careful removal of wall partitions, doors, and frames while preserving existing hardwood floors and salvaging wood baseboards and shoe molding for reuse. Specific demolition tasks include removal of one existing stairwell and its components, selective demolition of walls around existing stairs to remain, removal of existing ceiling systems including bulkheads and fixtures, elimination of a faux fireplace mantel and surround, removal of fire escapes with masonry repair, removal of all window treatments, removal of existing plumbing fixtures, and removal of existing carpet and vinyl flooring. The new work includes construction of new partition walls at full height, installation of gypsum wall board with metal hat channel furring, provision of custom wood shelves, installation of manual window shades and blackout shades, application of light diffusing vinyl film to windows, repair and painting of existing windows and wood elements, installation of a smartboard, provision of fire extinguisher cabinets, installation of polycarbonate corner guards, and infill of existing masonry openings with matching brick.
All demolition work must be executed in compliance with applicable federal, state, and local codes and regulations, with the contractor responsible for coordinating utility disconnections, obtaining permits, inspections, and tests. The contractor bears sole responsibility for means and methods of demolition, provision of temporary protection for existing elements, and maintenance of adjacent property access during the construction process. All demolished materials and equipment become contractor property and must be removed from the site in compliance with municipal, state, and federal regulations. Any demolition work performed in excess of contract documents or damage to existing-to-remain construction shall be repaired to like-new condition at the contractor's expense, with all infill or replacement work matching existing conditions in materials, construction, and finish. The contractor must guarantee all workmanship, material, and performance for one year from the date of acceptance. The drawing is dated January 5, 2016, with record drawings noted as prepared as-built on December 18, 2015, and references multiple related sheets for wall types, enlarged plans, interior elevations, door and window schedules, floor finish plans, and construction details.
View the file
Other files
Show 40 more
Latest 50 of 80 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D W
CAREFULLY REMOVE WALL
PARTITIONS, DOORS & FRAMES
FULL HEIGHT, DO NOT DAMAGE
EXISTING HARDWOOD
FLOOR TO REMAIN (TYPICAL)
SALVAGE ALL WOOD
BASEBOARDS AND SHOE
MOLDING FOR REUSE
CAREFULLY REMOVE WALL
PARTITIONS, DOORS &
FRAMESFULL HEIGHT, DO
NOT DAMAGE EXISTING
HARDWOOD FLOOR TO
REMAIN (TYPICAL),
SALVAGE ALL WOOD BASE
BOARDS AND SHOE
MOLDING FOR REUSE
CAREFULLY REMOVE WALL
PARTITIONS, DOORS & FRAMES
FULL HEIGHT, DO NOT DAMAGE
EXISTING HARDWOOD
FLOOR TO REMAIN (TYPICAL)
SALVAGE ALL WOOD BASE
BOARDS AND SHOE MOLDING
FOR REUSE
CAREFULLY REMOVE WALL PARTITIONS,
DOORS & FRAMES FULL HEIGHT, DO NOT
DAMAGE EXISTING HARDWOOD
FLOOR BENEATH TO REMAIN (TYPICAL)
SALVAGE ALL WOOD BASEBOARDS AND
SHOE MOLDING FOR REUSE
CAREFULLY REMOVE WALL PARTITIONS, DOORS
& FRAMES FULL HEIGHT, DO NOT DAMAGE
EXISTING HARDWOOD FLOOR TO REMAIN
(TYPICAL), SALVAGE ALL WOOD BASE BOARDS
AND SHOE MOLDING FOR REUSE
REMOVE EXISTING
STAIRWELL AND ALL
ITS COMPONENTS IN
ITS ENTIRETY
EXISTING
ELEVATOR
FIELD VERIFY EXISTING STAIR B
TO REMAIN, CAREFULLY
DEMOLISH WALL AROUND
AS INDICATED.
EXISTING STAIR A
TO REMAIN, CAREFULLY
DEMOLISH WALLS AROUND
AS INDICATED.
CAREFULLY REMOVE WALL
PARTITIONS, DOORS & FRAMES
FULL HEIGHT, DO NOT DAMAGE
EXISTING HARDWOOD
FLOOR TO REMAIN (TYPICAL)
SALVAGE ALL WOOD
BASEBOARDS AND SHOE
MOLDING FOR REUSE
CAREFULLY REMOVE PORTION OF
EXISTING WALL TO REMAIN, TO
ACCOMMODATE NEW DOOR AND
FRAME
REMOVE PORTION OF
FLOOR AND JOISTS FOR
NEW HVAC CHASE,
COORDINATE WITH
STRUCTURAL DRAWINGS
SHORE OPENING
REMOVE EXISTING
VINYL FLOOR AND
ASSOCIATED WALL
BASE (WOOD FLOOR
BENEATH TO REMAIN)
REMOVED RAISED
FLOOR FINISH,
WOOD FLOOR
BENEATH TO
REMAIN
DAMAGED
WINDOW &
TRIM, TO BE
REPAIRED
REMOVED WATER DAMAGED
PORTION OF WALL AND BASE,
PATCH/REPAIR AND PREP FOR
NEW FINISH
REMOVE
EXISTINGCARPET
(WOOD WALL BASE
AND WOOD FLOOR
BENEATH TO REMAIN)
UPPER SASH GLAZING FAILURE
REMOVE SASH TO REPAIR
REPAIR WOOD
FLOOR WITH
LIKE MATERIALS
REMOVE MISMATCH
PORTION OF WOOD BASE,
REPLACE WITH MATCHING
SALVAGED WOOD BASE,
PATCH AND REPAIR FOR
SMOOTH NEAT
APPEARANCE
DEMOLISH EXISTING CEILING IN ITS
ENTIRETY INCLUDING BULKHEADS,
CEILING FANS AND LIGHT FIXTURES,
UP TO EXISTING FLOOR JOISTS ABOVE
TYPICAL ENTIRE FLOOR
(DO NOT REMOVE STRUCTURAL
MEMBERS SUPPORTING FLOOR ABOVE
INFORM ARCHITECT OF CONDITION
FOUND AFTER REMOVAL OF CEILING)
REMOVE FAUX FIREPLACE
MANTEL AND SURROUND
IN ITS ENTIRETY, PATCH /
REPAIR AND PREP SURFACE
TO RECEIVE NEW FINISH
REMOVE ALL WINDOW
TREATMENTS AND
ASSOCIATED ATTACHMENTS
IN THEIR ENTIRETY, TYPICAL
REPAIR WOOD
FLOOR WITH
LIKE MATERIALS
EXISTING FIRE ESCAPE TO BE REMOVED IN
IT'S ENTIRETY, PATCH AND REPAIR HOLES
IN MASONRY WALL WITH LIKE MATERIALS
EXISTING FIRE ESCAPE TO BE REMOVED IN
IT'S ENTIRETY, PATCH AND REPAIR HOLES
IN MASONRY WALL WITH LIKE MATERIALS
REMOVE WOOD BASE
AROUND WALL
REMOVE WOOD BASE
AROUND COLUMNS
REMOVE WOOD BASE
AROUND COLUMNS
REMOVE EXISTING
PLUMBING FIXTURES
IN THEIR ENTIRETY
THESE ROOMS
REPAIR WALL TO LIKE
NEW CONDITION
WITH LIKE MATERIALS
WHERE EXISTING
WALL WAS REMOVED,
REPAIR WALL TO LIKE
NEW CONDITION
WITH LIKE MATERIALS
WHERE EXISTING
WALL WAS REMOVED,
REPAIR WALL TO LIKE
NEW CONDITION
WITH LIKE MATERIALS
WHERE EXISTING
WALL WAS REMOVED,
REPAIR WALL TO LIKE
NEW CONDITION
WITH LIKE MATERIALS
WHERE EXISTING
WALL WAS REMOVED,
REPAIR WALL TO LIKE
NEW CONDITION
WITH LIKE MATERIALS
WHERE EXISTING
WALL WAS REMOVED,
REPAIR WALL TO LIKE
NEW CONDITION
WITH LIKE MATERIALS
WHERE EXISTING
WALL WAS REMOVED,
REPAIR WALL TO LIKE
NEW CONDITION
WITH LIKE MATERIALS
WHERE EXISTING
WALL WAS REMOVED,
REPAIR WALL TO LIKE NEW CONDITION
WITH LIKE MATERIALS WHERE EXISTING
WALL WAS REMOVED,
REPAIR WALL TO LIKE
NEW CONDITION
WITH LIKE MATERIALS
WHERE EXISTING
WALL WAS REMOVED,
REPAIR WALL TO LIKE
NEW CONDITION
WITH LIKE MATERIALS
WHERE EXISTING
WALL WAS REMOVED,
REPAIR WALL TO LIKE
NEW CONDITION
WITH LIKE MATERIALS
WHERE EXISTING
WALL WAS REMOVED,
REMOVE EXISTING
WALLPAPER FULL
HEIGHT
A4.0
A4.0
A4.1
A4.1
B C D EA G
FACIAL / COUPLE
MASSAGE
STAIR
D2
DISPENSARY
MEN
WOMEN
CUST.
206A
EXISTING STAIR
C2
OFFICE 2
OFFICE 1
CLASSROOM
DOWN TO
1ST FLOOR
UP TO
3RD FLOOR
U P
T O
R
D F
L O
O R
D O
W N
T O
S
T F
L O
O R
FRESHMAN CLINIC
FULL HEIGHT
WALL
T.O.W.
6'-0" A.F.F.
CORRIDOR
200A
CLOSET
A4.0
A4.0
EXISTING STAIR
B2
EXISTING
ELEVATOR
E
A4.1
A4.1
4 4 4 4 4 4 4 4 4 4
206A
D2
3' - 10" 17' - 6 3/8"
11 10 11 12
A L
IG
N
A L
IG
N
906A
906A
906A
906A
906A
906A
906.1
A5.2
A5.2
A7.0
A5.2
A7.0
R
R
' - 0
A7.0
R
25' - 5 107/256"
5' - 8"
9' - 0"
16' - 0"
31' - 4"
30' - 2 3/4"
/2
/2
A6.1
4' - 11 1/4" 8' - 7 7/8"
10 5/8"
A L
IG
N A
L
IG
N
ALIGN1
1' - 9" 3' - 0" 5' - 6 1/4" 11' - 6 3/4"
A6.0
906A
906A
906A
906A
A6.0
A6.1
A5.0
A5.2
A6.0
A6.0
B
C
B
SIM
D
E
B
SIM
1' - 4"
/2
/4
/4
F
/8
/4
/4 "7
A2.1
CORRIDOR
SIM.
A5.2
DEMOLITION PLAN LEGEND
OBJECT TO BE DEMOLISHED
EXISTING OBJECT TO REMAIN
EXISTING WALLS TO REMAIN
DEMOLITION GENERAL NOTES
A. ALL DEMOLITION WORK SHALL BE EXECUTED IN COMPLIANCE WITH ALL
APPLICABLE FEDERAL, STATE, AND LOCAL CODES, LAWS, AND
REGULATIONS.
B. CONTRACTOR IS TO COORDINATE ALL UTILITY DISCONNECTION WORK
PRIOR TO START OF DEMOLITION WORK.
C. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND PAYING
FOR ALL PERMITS, INSPECTIONS, TESTS, ETC. THAT MAY BE REQUIRED
FOR ALL DEMOLITION WORK.
D. CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL MEANS AND METHODS
OF ALL DEMOLITION WORK AND FOR PROVIDING ALL NECESSARY
TEMPORARY PROTECTION AS NECESSARY FOR THE SAFETY AND
STABILITY OF ALL EXISTING ELEMENTS AND STRUCTURE TO REMAIN.
E. CONTRACTOR SHALL MAINTAIN EXISTING ACCESS TO ADJACENT
PROPERTY DURING DEMOLITION/CONSTRUCTION.
F. CONTRACTOR SHALL VISIT THE SITE AND FACILITY TO VERIFY ALL
EXISTING CONDITIONS AND VERIFY THE SCOPE OF WORK INDICATED
BY ALL CONTRACT DOCUMENTS; FAILURE TO REASONABLY
DETERMINE AND/OR ANTICIPATE THE IMPACT OF THE SCOPE OF
WORK ON EXISTING CONDITIONS SHALL NOT BE JUSTIFICATION
FOR ADDITIONAL COMPENSATION; ANY DISCREPANCIES DISCOVERED
IN THE CONTRACT DOCUMENTS SHALL BE IMMEDIATELY REPORTED
TO ARCHITECT PRIOR TO SUBMISSION OF BID.
G. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL EXISTING
FIXTURES AND EQUIPMENT THAT REMAINS WITHIN BUILDING OR ON
SITE, UNLESS NOTED OTHERWISE.
H. UNLESS NOTED OTHERWISE, ALL DEMOLISHED MATERIAL AND
EQUIPMENT IS TO BECOME THE PROPERTY OF THE CONTRACTOR
AND SHALL BE REMOVED FROM THE SITE IN A MANNER THAT IS SAFE
AND COMPLIANT WITH MUNICIPAL, STATE, AND FEDERAL
REGULATIONS; NO ON-SITE SALE OF MATERIALS IS ALLOWED.
I. CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION AGAINST
WEATHER INFILTRATION AND CONSTRUCTION ACTIVITIES FOR ALL
EXISTING CONSTRUCTION TO REMAIN DURING THE DEMOLITION AND
CONSTRUCTION PROCESS TO PREVENT DAMAGE TO EXISTING
FINISHES OR MATERIALS THAT ARE TO REMAIN.
J. ALL DEMOLITION WORK PERFORMED IN EXCESS OF THAT INDICATED
ON PLANS AND ANY DAMAGE TO EXISTING-TO-REMAIN
CONSTRUCTION SHALL BE PATCHED, REPAIRED, AND/OR REPLACED
TO "LIKE-NEW" CONDITION AT CONTRACTOR'S EXPENSE.
K. ALL INFILL OR REPLACEMENT WORK SHALL MATCH EXISTING
CONDITIONS IN MATERIALS, CONSTRUCTION, AND FINISH, UNLESS
SPECIFICALLY NOTED ELSEWHERE IN THE DEMOLITION
DOCUMENTS; MATERIAL NOT SPECIFICALLY SPECIFIED SHALL BE
EQUAL IN QUALITY TO EXISTING MATERIAL OR LIKE KIND;
GUARANTEE ALL WORKMANSHIP, MATERIAL, AND PERFORMANCE FOR
A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE (UNLESS
OTHERWISE NOTED).
L. CONTRACTOR IS RESPONSIBLE FOR DEMOLITION AND REMOVAL OF ALL
COMPONENTS IN SUCH A WAY AS TO NOT DAMAGE OR OTHERWISE
COMPROMISE EXISTING STRUCTURE-TO-REMAIN.
M. NOTIFY ARCHITECT AND STRUCTURAL ENGINEER REGARDING
PRE-EXISTING OR CONCURRENT COMPROMISED CONDITIONS
(INCLUDING EXCESSIVE CORROSION, WARPING, OR DEFLECTION)
THAT IS OBSERVED IN EXISTING STRUCTURE-TO-REMAIN (INCLUDING,
BUT NOT LIMITED TO, STEEL DECK, JOISTS, BEAMS, AND COLUMNS).
NEW WORK GENERAL NOTES
A. ALL WALLS ARE FULL HEIGHT, U.N.O. (REFER TO WALL TAG WITH
HEIGHT INDICATED OR TOP OF WALL DELINEATION.
B. PROVIDE GYPSUM BOARD CONTROL JOINTS EVERY 30 FEET MINIMUM.
C. REFER TO ENLARGED PLANS FOR ADDITIONAL DETAILING OR
DIMENSIONING NOT SHOWN THIS SHEET. REFER TO SHEET A0.1 FOR
WALL TYPES.
D. REFER TO A6 SERIES SHEETS FOR ENLARGED PLANS AND
CORRESPONDING INTERIOR ELEVATIONS.
E. REFER TO A7 SERIES SHEETS FOR DOOR AND WINDOW SCHEDULES,
ELEVATIONS AND DETAILS.
F. REFER TO A8 SERIES SHEETS FOR FLOOR FINISH PLANS, SCHEDULES
AND DETAILS.
G. ALL DIMENSIONS ARE FROM EXISTING FACE OF WALL TO FACE OF
STUD, OR FROM OUTSIDE FACE OF STUD TO OUTSIDE FACE OF STUD,
U.N.O.
H. PATCH EXISTING WOOD FLOOR WITH LIKE MATERIALS WHERE
DAMAGED BY DEMOLITION APPROX. 15% OF ENTIRE FLOOR SQUARE
FOOTAGE.
J. ALL EXISTING WOOD BASE BOARDS TO REMAIN, U.N.O.
K. SALVAGE ALL DEMOLISHED WOOD BASE BOARDS FOR REUSE IN THIS
PROJECT.
NEW WORK CODED NOTES
1. CUSTOM WOOD SHELVES, REFER TO DETAILS.
2. WASHER AND DRYER, N.I.C.
3. EXISTING STIAR ENCLOSURE TO REMAIN, PAINT.
4. PROVIDE MANUAL WINDOW SHADES, REFER TO SPECIFICATIONS.
5. PROVIDE MANUAL BLACKOUT SHADES, REFER TO SPECIFICATIONS.
6. LIGHT DIFFUSING VINYL FILM APPLIED TO ENTIRE GLASS SURFACE OF
WINDOW. BASIS OF DESIGN: SOLYX SX-1405-49.
7. EXISTING WINDOW AND WOOD TO BE REPAIRED AND SANDED, PAINT.
8. SMARTBOARD, N.I.C.
9. 5/8" GYPSUM WALL BOARD FURRING OVER EXISTING COLUMN, TO
ALIGN WITH WALL.
10. NEW BULKHEAD ABOVE REFER TO REFLECTED CEILING PLANS.
11. ADHERE 5/8" GYPSUM WALL BOARD TO EXISTING WALL/COLUMN
SURFACE.
12. ALIGN FACE OF PARTITION WITH FACE OF EXISTING COLUMN.
13. TACK SURFACE COVERING WALL TO WALL, BASEBOARD TO CEILING.
BASIS OF DESIGN: TAC-WALL by WALL TALKERS.
14. REPAIR SURFACE WITH LIKE MATERIALS, PREP FOR SMOOTH NEAT
APPEARANCE, PAINT.
15. 5/8" GYPSUM WALL BOARD OVER 7/8" METAL HAT CHANNEL FURRING
AT 16" O.C..
16. SEMI-RECESSED FIRE EXTINGUISHER CABINET AND FIRE
EXTINGUISHER.
X
17. CLEAR LEXAN (POLYCARBONATE CORNER GUARD, 1 1/8" x 1 1/8"x 48"
MOUNTED ABOVE WOOD BASEBOARD.
18. EXTEND 5/8" GWB UP AND OVER WALL.
19. REMOVED EXISTING PLYWOOD INFILL. INFILL EXISTING MASONRY
OPENING WITH BRICK TO MATCH EXISTING, SIMILAR TO DETAIL 5/A5.2.
20. PROVIDE RAMPED WOOD THRESHOLD (STAIN TO MATCH WOOD FLOOR)
C
COMMONWEALTH
T
R E
R
A
H C
I
N K
E
UT
OF
B
3 87
I
R E
G
No.
TS E
NT U
C E
YK T
N E R
D
ER
RB
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DATE
DATE
ENGINEERING
DIVISION OF
AGENCY
AUTHORIZED AGENT
FOR INTENT ONLY
DIV. OF ENGR.
REVIEWED
ENGR. ACCT. NO.
DRAWING NO.
DATE
A&E FILE NO.
CHECKED BY
SHEET DRAWN BY
RECORD DATE
DATEREVISIONS
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES MANAGEMENT
DIVISION OF ENGINEERING
FRANKFORT, KENTUCKY
/5
/2
:5 :5
P
M C
U s e rs
\R H in s o n \D o c u m e n ts
\1
G
C T
C
A b o d e B u il d in g R e n o v a ti o n rh in s o n .r v t
A1.2
SECOND FLOOR DEMOLITION AND
NEW WORK PLANS
470-C5N5-NC11-01
GATEWAY URBAN CAMPUS
09/25/14
201114.02
BB
REH
PROFESSIONAL SERVICES CLASSROOM CENTER
438-440 Scott St., Covington, KY 41011
SCALE: 1/4" = 1'-0"A1.2
1 SECOND FLOOR - DEMOLITION
SCALE: 1/4" = 1'-0"A1.2
2 SECOND FLOOR - NEW WORK
NORTH
PLAN
NORTH
PLAN
AS-BUILT
12-18-15
RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED IN PART, ON THE BASIS OF INFORMATION COMPILED BY OTHERS. THE ARCHITECT/ENGINEER HAS NOT VERIFIED THE ACCURACY OR COMPLETENESS OF THE INFORMATION, AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS THAT MAY BE
INCORPORATED AS A RESULT OF ERRONEOUS INFORMATION PROVIDED BY OTHERS.
File details come from the government source that posted it. Updated .