This is a reflected ceiling plan document prepared by the Commonwealth of Kentucky, Finance and Administration Cabinet, Department for Facilities Management, Division of Engineering for the Gateway Urban Campus Classroom Center renovation project located at 438-440 Scott Street in Covington, Kentucky. The document provides detailed architectural specifications for second and third floor ceiling installations, including ceiling heights ranging from 7 feet to 10 feet, material specifications such as gypsum board, acoustical ceiling panels, and metal stud framing at 24-inch on-center spacing. The plans identify multiple room types including classrooms, offices, massage clinical labs, dispensary areas, and support spaces, with specific ceiling treatment requirements and MEP (mechanical, electrical, plumbing) coordination details. The document includes general notes requiring control joints per industry standards, sound attenuation batt insulation between third floor wood joists, firestopping around ductwork penetrations, and crown molding installations to match existing conditions. Record drawings were marked as-built on December 18, 2015, with the original drawing dated September 25, 2014.
The architectural specifications indicate a comprehensive renovation project involving rated ceiling assemblies constructed of 5/8-inch Type X gypsum board with 2.5-inch metal C-H studs, along with both 2-by-2-foot acoustical ceiling panels in two colors and recessed fluorescent lighting fixtures. The document references structural drawings for lintel specifications, MEP drawings for ductwork sizing and locations, and detail sheets for soffit construction and bulkhead installations. This reflects ceiling plan serves as a coordinating document between architectural and building systems trades, with the architect assuming no responsibility for verification of information provided by others regarding accuracy or completeness.
View the file
Other files
Show 40 more
Latest 50 of 80 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A4.0
A4.0
A4.1
A4.1
CLASSROOM
OFFICE 1
FRESHMAN CLINIC
OFFICE 2
DISPENSARY
CLOSET
CORRIDOR
200A
FACIAL / COUPLE
MASSAGE
9' - 2"
ACT-1
9' - 2"
ACT-1
9' - 2"
ACT-1
9' - 6"
ACT-1
9' - 2"
ACT-1
9' - 6"
ACT-2
WOMEN
CUST.
206A
MEN
9' - 0"
ACT-1
A4.0
A4.0
7' - 6"
GCB
STAIR
D2 1
OPEN TO
STAIR
LANDINGS
ABOVE
EXISTING STAIR
C2
OPEN TO ABOVE
8' - 0"
GCB
EXISTING
ELEVATOR
E
A4.1
A4.1
10' - 0"
GCB
9' - 6"
GCB
BULKHEAD 9' - 0" A.F.F.
9' - 2"
ACT-1
10' - 0"
GCB
9' - 2"
ACT-1
9' - 2"
ACT-1
EXISTING STAIR
B2
E2
A2.0
A2.0
8 8
EXISTNG
GYP.BD.
CEILING EXISTNG
GYP.BD.
CEILING
NEW CEILING TO
MATCH EXISTING
HEIGHT
PATCH / REPAIR EXISTING GYP.BD.
CEILING TO ALIGN WITH NEW
CEILING FOR A SMOOTH NEAT FLAT
PAINTABLE SURFACE
8' - 2"
GCB
BULKHEAD 8' - 0" A.F.F.
A2.1
A2.1
A2.1
A2.1
A2.1
TYP.
A2.1
TYP.
A2.1
TYP.
TYP. TYP. 8
A2.1
A2.1
A2.1
TYP.
A2.1
TYP.
TYP.
A2.1
A4.0
A4.0
A4.1
A4.1
A4.0
A4.0
CLIENT MASSAGE
301D
CLIENT MASSAGE
301E
LINENS
301F
CORRIDOR
CLIENT MASSAGE
301A
CLIENT MASSAGE
301B
CLIENT MASSAGE
301C
MASSAGE
CLINICAL LAB
EXISTING
ELEVATOR
E
OFFICE
302C
STAIR
D3
CORRIDOR
300A
LOBBY
EXISTING STAIR
C3
MEN
WOMEN
STORAGE
CLOSET
10' - 0"
ACT-2
10' - 0"
ACT-2
10' - 0"
ACT-2
10' - 0"
ACT-2
9' - 6"
ACT-2
9' - 6"
ACT-2
9' - 6"
ACT-1
9' - 8"
ACT-1
8' - 8"
GCB
8' - 0"
GCB
8' - 8"
GCB
8' - 0"
GCB
9' - 6"
GCB
8' - 6"
ACT-2
8' - 0"
GCB
10' - 0"
GCB
A4.1
A4.1
8' - 0"
GCB
BULKHEAD 7' - 0" A.F.F.
8' - 0"
GCB BULKHEAD 7' - 6" A.F.F.
HVAC
302A
ROOF ACCESS
302B
9' - 6"
ACT-1
E2
6 6 6
A2.0
A2.0
A2.0
PAINT
OPEN
PAINT
OPEN
3 3 3 3 3 3
333333
3' - 6" 3' - 6" EQ
EQ EQ
3' - 8"
2' - 6" 5' - 0" 5' - 0" 5' - 0" 3' - 8" 3' - 0"
"2
2' - 6"2' - 6"
8"
1' - 0" 1' - 0"
EQ 7' - 0" EQ
EQ EQ
E Q
E Q
EQ EQ
E Q
E Q
6"
EXISTNG
GYP.BD.
CEILING
PATCH / REPAIR EXISTING GYP.BD.
CEILING TO ALIGN WITH NEW
CEILING FOR A SMOOTH NEAT FLAT
PAINTABLE SURFACE
A2.1
SIM.
8' - 0"
GCB
A2.0
SIM.
8' - 0"
GCB
8' - 10"
GCB
REFLECTED CEILING
PLAN LEGEND
X'-XX"
GWB
X'-XX"
ACT-2
OPEN
AP
TRACK LIGHTING WITH PIVOTAL HEAD
LARGE DECORATIVE PENDANT MOUNT FIXTURE
WALL MOUNTED FIXTURE
2' x 2' RECESSED FLOURESCENT FIXTURE
PENDANT MOUNT INDIRECT/DIRECT
FLOURESCENT FIXTURE
RECESSED LINEAR SLOT FIXTURE
RECESSED DOWNLIGHT
RECESSED DIRECTIONAL DOWNLIGHT
PAINTED GYP. BOARD & METAL STUD STRUCTURE
RATED CEILING: 5/8" TYPE "X" GYPSUM BOARD,
2 1/2" METAL C-H STUDS @ 24" O.C., 1" GYPSUM
SHAFT LINER PANEL, TEST USG-040901
2' x 2' NON-SAG ACOUSTICAL CEILING PANEL, COLOR #1
2' x 2" NON-SAG ACOUSTICAL CEILING PANEL, COLOR #2
OPEN TO STRUCTURE ABOVE. PAINT ALL EXPOSED
STEEL DECK, STRUCTURE, DUCTWORK & MEP
ITEMS
ACCESS PANEL 36" x 36"(AP1), or 24" x 24" (AP2)
X'-XX"
ACT-1
X'-XX"
RATED
REFLECTED CEILING
GENERAL NOTES
A. CEILING RELATED MEP ITEMS ARE SHOWN ON
REFLECTED CEILING PLAN FOR THE SOLE PURPOSE OF
INDICATING THEIR RESPECTIVE LOCATIONS AND
COORDINATION WITH CEILING FINISH LAYOUT. REFER
TO MEP DRAWINGS FOR TYPE, SIZE AND OTHER
REQUIREMENTS.
B. U.N.O. PROVIDE GYP. BD. CONTROL JOINTS AS
REQUIRED BY INDUSTRY STANDARDS OR
SPECIFICATIONS, WHICHEVER IS MORE RESTRICTIVE.
CONFIRM LOCATIONS WITH ARCHITECT.
REFLECTED CEILING
CODED NOTES
1. DASHED LINES REPRESENT WALLS BELOW.
2. WALLS NOT FULL HEIGHT, NEW CEILING EXTENDS
OVER.
3. SURFACE MOUNTED CEILING TRACK FOR MOVEABLE
PRIVACY CURTAINS.
4. NOT USED.
5. METAL SHIPS LADDER TO ROOF HATCH, REFER TO
DETAILS.
6. "SOLATUBE" SKYLIGHTS, REFER TO DETAIL 4/A4.0.
7. EXISTING BULKHEAD ABOVE TO REMAIN.
8. PROVIDE 3 1/2" KRAFT FACED SOUND ATTENUATION
BATT INSULATION BETWEEN THIRD FLOOR WOOD
JOISTS, SECURE TIGHT TO UNDERSIDE EXISTING
3RD FLOOR DECK WITH INSULATION HANGERS @
24" O.C. BASIS OF DESIGN: OWENS CORNING,
QUIETZONE ACOUSTIC BATTS.
X
T.O.S. 13' - 3"
T.O.S. 11' - 0"
EXISTING CROWN MOULDING
BOTH SIDES OF WALL
PATCH AND REPAIR OPENING
PROVIDE SKIM-COAT OF PLASTER
TO MATCH EXISTING, PROVIDE A
SMOOTH NEAT APPEARANCE
(BOTH SIDES OF WALL)
PRE-FINISHED S.M. ROUND
SLEEVE WITH 1" WIDE BAND
ADHERE TO WALL (BOTH
SIDES OF WALL)
STEEL LINTEL, REFER
TO STRUCTURAL DRAWINGS
20" DIA. DUCT - THRU WALL
STEEL LINTEL & BEAM, REFER
TO STRUCTURAL DRAWINGS
PATCH AND REPAIR OPENING
PROVIDE SKIM-COAT OF PLASTER
TO MATCH EXISTING, PROVIDE A
SMOOTH NEAT APPEARANCE
(BOTH SIDES OF WALL)
9' - 0"
GCB
906A
T.O.W. 9' - 11"
PROVIDE 1/2" PLYWOOD
AROUND PERIMETER OF
OPENING, SECURE
PROVIDE WOOD BLOCKING
AS REQUIRED TO FORM
OPENING FOR DUCTWORK
AND METAL SLEEVE
EXIST. WALL (F.V.)
C E
N T
E R
L
IN
E O
F D
U C
T
/4
2ND FLOOR
16' - 2"
A2.1
PROVIDE FIRESTOPPING
AROUND ENTIRE
PERIMETER
REFER TO MEP DRAWINGS FOR
DUCTWORK SIZES AND LOCATION
11' - 0"
12' - 4 1/4" APPROX.
DUCT CENTERLINE
PROVIDE CROSS BRACING
BETWEEN DUCT FOR
SECURE STABLE SOFFIT
11' - 0"
GCB
964R
964R
964R
PROVIDE NEW CROWN
MOULDING TO MATCH
EXISTING , AROUND
PERIMETER OF SOFFIT
2ND FLOOR
16' - 2"
F
A2.1
11' - 0"
GCB
964R
REFER TO
STRUCT. DWGS.
FOR LINTEL SIZE
AND DETAIL
REFER TO MEP
DWGS. FOR DUCT
SIZES AND LOCATION
PROVIDE FIRESTOPPING
AT ENTIRE PERIMETER
DUCT WORK
PROVIDE FIRESTOPPING
AT ENTIRE PERIMETER
DUCT WORK
PROVIDE FIRESTOPPING
AT ENTIRE PERIMETER
DUCT WORK
PROVIDE FIRESTOPPING
AT ENTIRE PERIMETER
DUCT WORK
PROVIDE STUD
X-BRACING OR
KICKERS BETWEEN
DUCTWORK AS
REQUIRED TO SURE
AND STABILIZE
RATED SOFFIT
964R
964R
8' - 2"
GCB
9' - 2"
ACT-1
10' - 0"
GCB
EXISTING
SECURE EXISTING
CEILING TO NEW
BULKHEAD
3 5/8" METAL STUDS @
16" O.C., SECURED TO
STRUCTURE ABOVE
1' - 0"
9' - 2"
ACT-1
2"x2" ANGLE MOLDING
INSTALL FLUSH WITH FACE
OF WINDOW TRIM
2"
PAINT GRADE WOOD BLOCKING,
CUT FLUSH WITH DEPTH OF WINDOW TRIM,
SECURED TO WALL FLUSH WITH BOTTOM OF
2"x2" ANGLE MOLDING, PAINT TO MATCH
CEILING GRID
9' - 2"
ACT-1
2"x2" ANGLE MOLDING
INSTALL FLUSH WITH FACE
OF WINDOW TRIM
2"
C
COMMONWEALTH
T
R E
R
A
H C
I
N K E
UT
OF
B
3 87
I
R E G
No.
TS E
NT U
C E
YK T
N E R
D
ER
RB
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DATE
DATE
ENGINEERING
DIVISION OF
AGENCY
AUTHORIZED AGENT
FOR INTENT ONLY
DIV. OF ENGR.
REVIEWED
ENGR. ACCT. NO.
DRAWING NO.
DATE
A&E FILE NO.
CHECKED BY
SHEET DRAWN BY
RECORD DATE
DATEREVISIONS
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES MANAGEMENT
DIVISION OF ENGINEERING
FRANKFORT, KENTUCKY
/5
/2
:5 :0
P
M C
U s e rs
\R H in s o n \D o c u m e n ts
\1
G
C T
C
A b o d e B u il d in g R e n o v a ti o n rh in s o n .r v t
A2.1
2ND & 3RD FLR REFLECTED CLG
PLANS
470-C5N5-NC11-01
GATEWAY URBAN CAMPUS
09/25/14
201114.02
BB
REH
PROFESSIONAL SERVICES CLASSROOM CENTER
438-440 Scott St., Covington, KY 41011
SCALE: 1/4" = 1'-0"A2.1
SECOND FLOOR REFLECTED
CEILING PLAN
SCALE: 1/4" = 1'-0"A2.1
THIRD FLOOR REFLECTED
CEILING PLAN
1 Revision 1 Date 1
SCALE: 1 1/2" = 1'-0"A2.1
3 ENLARGED DETAIL
SCALE: 3/4" = 1'-0"A2.1
5 RATED SOFFIT DETAIL #2
SCALE: 3/4" = 1'-0"A2.1
4 RATED SOFFIT DETAIL #1
SCALE: 3/4" = 1'-0"A2.1
6 PR-012 - BULKHEAD @ STAIR B2
SCALE: 3/4" = 1'-0"A2.1
7 ENLARGED DETAIL
SCALE: 3/4" = 1'-0"A2.1
CLG GRID MOLDING @
EXTERIOR WINDOWS
AS-BUILT
12-18-15
RE
C
O
RD
D
RA
W
IN
G S
TH
ES
E
RE
C O
RD
D
RA
W
IN
G
S
HA
V E
BE
EN
P
RE
PA
RE
D
IN
P A
RT
, O
N T
HE
B
A
SI
S O
F
IN
FO
RM
A
TIO
N C
O M
PI
LE
D B
Y O
TH
ER
S.
T
HE
A
RC
HI
TE
C
T/
EN
G
IN
EE
R
HA
S
N O
T V
ER
IF
IE
D
T
HE
A C
C
UR
A C
Y O
R C
O M
PL
ET
EN
ES
S O
F
TH
E
IN
FO
RM
A
TIO
N , A
N D
S
HA
LL
N
O T
BE
R
ES
PO
N
SI
BL
E
FO
R
A N
Y
ER
RO
RS
O R
O M
IS
SI
O N
S
TH
A T
M A
Y
BE
IN
C
O
RP
O
RA
TE
D
A S
A R
ES
UL
T O
F
ER
RO
N
EO
US
IN
FO
RM
A
TIO
N
P
RO
V
ID
ED
B
Y O
TH
ER
S.
File details come from the government source that posted it. Updated .