This is a plumbing demolition drawing prepared by the Commonwealth of Kentucky Department for Facilities & Support Services, Division of Engineering, in coordination with KLH Engineers for the Gateway Urban Campus project located at 438-440 Scott Street, Covington, Kentucky. The project encompasses plumbing demolition work on the basement and first floors of the facility and includes detailed specifications for removal and reuse of existing plumbing systems. The scope of work includes demolition of gas piping after the meter, sanitary piping, water supply piping, and a gas meter labeled AC-250, with provisions to reuse an existing 2-inch water service line and gas meter labeled AL-425. Additionally, the project requires verification of existing piping conditions prior to bidding, replacement of a sump pump with a similar model, and rerouting of piping systems where existing walls are removed or fixtures are relocated. The drawing was prepared on December 18, 2015, with professional services provided by KLH Engineers, PSC, based in Lexington, Kentucky.
The plumbing demolition specifications require coordination between the general contractor and plumbing subcontractor to maintain integrity of systems serving fixtures designated to remain, remove all orphaned piping capped beyond finish surfaces, and coordinate removed fixtures with the general contractor for relocation or future use. The project prioritizes preservation of existing plumbing infrastructure where feasible while systematically removing non-functional systems and fixtures, with all work subject to the architectural demolition plan designations for existing conditions to remain. No pricing, contract term, or award information is provided in this drawing document.
View the file
Other files
Show 40 more
Latest 50 of 80 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T
T
B C D EA G
F
252522
B C D EA G
F
S S
S
S
S
C W
EXISTING GAS METERS
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DATE
DATE
ENGINEERING
DIVISION OF
AGENCY
AUTHORIZED AGENT
FOR INTENT ONLY
DIV. OF ENGR.
REVIEWED
ENGR. ACCT NO.
DRAWING NO.
DATE
A&E FILE NO.
CHECKED BY
SHEET DRAWN BY
RECORD DATE
DATEREVISIONS
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING
FRANKFORT, KENTUCKY
WWW.KLHENGRS.COM
ENGINEERS, PSC
MECHANICAL/ELECTRICAL ENGINEERS
KOHRS LONNEMANN HEIL
LEXINGTON, KENTUCKY
COLUMBUS, OHIO
DAYTON, OHIO
NEW YORK, NEW YORK
1538 ALEXANDRIA PIKE, SUITE
11 FT. THOMAS, KENTUCKY
41075 800-354-9783 859-442-8050
859-442-8058 FAX
KLH PRO. NO.
11369.04
PROFESSIONAL SERVICES CLASSROOM CENTER
/1
/2
:3 :1
A
M
PD1.0
PLUMBING - DEMOLITION -
BASEMENT AND 1ST FLOORS
C5N5-NC11-01
GATEWAY URBAN CAMPUS
438-440 Scott St., Covington, KY 41011
12/18/15
201114.02
FAC
KPO
SCALE: 1/4" = 1'-0"PD1.0
1 PLUMBING - DEMOLITION - 1ST FLOOR
SCALE: 1/4" = 1'-0"PD1.0
2 PLUMBING - DEMOLITION - BASEMENT FLOOR
KEYED NOTES
21 DEMO ALL GAS PIPING AFTER METER.
22 DEMO SANITARY PIPING.
23 VERIFY CONDITION OF EXISTING SANITARY PIPE. REUSE PIPE THAT
HAS BEEN IDENTIFIED AS EXISTING TO REMAIN AND REPLACE PIPE
THAT IS DEEMED TO BE DAMAGED OR UNUSABLE.
25 DEMO WATER SUPPLY PIPING.
26 VERIFY LOCATION, SIZE, AND CONDITION OF WATER PIPING PRIOR
TO BID. EXISTING 2" SERVICE TO BE REUSED FOR DOMESTIC
WATER SERVICE ONLY. DEMO WATER PIPING INSIDE BUILDING.
27 DEMO GAS METER LABELED AC-250. REUSE GAS METER LABELED
AL-425 FOR SERVICE TO THIS BUILDING.
33 DEMO SUMP PUMP, REPLACE WITH SIMILAR MODEL. REFER TO
EQUIPMENT SCHEDULE.
GENERAL PLUMBING DEMOLITION NOTES
A. PLUMBING SYSTEMS SERVING EXISTING TO REMAIN PLUMBING
FIXTURES AS IDENTIFIED ON ARCHITECTURAL DEMOLITION SHEET
SHALL REMAIN INTACT AND IN GOOD WORKING ORDER.
B. AT ALL LOCATIONS WHERE PLUMBING FIXTURES ARE TO BE
REMOVED, PLUMBING SUBCONTRACTOR SHALL REMOVE PIPING
(WATER, WASTE, VENT) TO A POINT BEYOND FINISH SURFACE AND
CAP OFF. WHERE PIPING SERVING EXISTING FIXTURE TO BE
REMOVED ALSO SERVES FIXTURES THAT ARE TO REMAIN, PIPING
SHALL BE REROUTED AND RECONNECTED AS REQUIRED TO
ACCOMMODATE REMODELED AREAS AS REQUIRED.
C. WHERE EXISTING WALLS ARE REMOVED AND PIPING IS FOUND THAT
MUST REMAIN, PLUMBING SUBCONTRACTOR SHALL REROUTE AND
RECONNECT PIPING AS REQUIRED, E.G. DOMESTIC WATER PIPING,
GAS, SOIL, WASTE, VENT, AND ROOF LEADER PIPING.
D. ALL PLUMBING PIPING THAT IS FOUND TO NO LONGER SERVE ANY
PURPOSE SHALL BE REMOVED AND CAPPED OFF BEYOND FINISH
SURFACE.
E. COORDINATE ALL REMOVED PLUMBING FIXTURES WITH G.C FOR
RELOCATION OR FUTURE USE.