19-10 - S4-1 - FRAMING DETAILS.pdf

PDF 136 KB Posted

Attached to
Surplus Real Property Sale For Economic Development; 438 Scott Boulevard
Solicitation number
RFP260305
Issued by
Hart County, Kentucky

About this file

This record drawing document details framing specifications for the Gateway Urban Campus project located at 438-440 Scott Street in Covington, Kentucky, prepared by the Commonwealth of Kentucky Finance and Administration Cabinet, Department for Facilities and Administration, Division of Engineering, in conjunction with the architectural and engineering firm Brown & Kubican, PSC. The drawing sheet S4.1, dated December 18, 2015, provides comprehensive framing details including floor and roof construction systems, structural connections, and reinforcement specifications for a renovation or construction project. The document includes multiple detailed sections (labeled A through S) drawn at 3/4" = 1'-0" scale, illustrating the integration of existing structural elements such as masonry walls, wood floor joists, wood rafters, and wood girders with new construction components including concrete beams, steel beams, steel columns, and wood headers. Key construction elements specified include concrete beam reinforcement with continuous ledger boards, installation of wood sleepers for hardwood flooring support, steel girder reinforcement channels, A307 and A325-N bolt connections, metal joist hangers, and temporary shoring requirements during construction.

The specifications emphasize critical construction quality standards, including proper concrete consolidation to prevent voids and honeycombs in exposed concrete faces, smooth formed and grout-cleaned finishes on all exposed concrete surfaces, and precise installation of hardwood shims to create proper bearing conditions where existing conditions prevent structural members from bearing directly on new steel. The document references multiple related detail drawings and specifications across various sheets, including architectural drawings for floor patches, roof construction, mechanical units, curbs, and chases. Additional notes address field verification requirements, temporary shoring adjustments limited to three inches maximum to ensure levelness between joists, and procedures for managing conflicts between new and existing through-bolts, with notification to the engineer required if conflicts cannot be avoided. The record drawings bear the notation that they were prepared based on information compiled by others and that the engineer is not responsible for errors or omissions resulting from erroneous information provided by third parties.

View the file

Other files

File Type Posted
66-67 - CT0.0.pdf PDF
51-49 - HV1.3.pdf PDF
8-13 - A1-1 - FIRST FLOOR DEMOLITION AND NEW WORK PLANS.pdf PDF
34-35 - PD1.1.pdf PDF
30-30 - A8-2 - Basement - FINISHES.pdf PDF
29-29 - A8-1 - ROOM FINISH PLANS (N-I-C- FURNITURE LAYOUT).pdf PDF
12-11 - S4-2 - FRAMING DETAILS.pdf PDF
15-8 - S2-5 - ROOF FRAMING PLAN.pdf PDF
73-19 - A3-0 - BUILDING ELEVATIONS.pdf PDF
49-51 - HV2.0.pdf PDF
72-72 - CT5.2.pdf PDF
67-69 - CT1.2.pdf PDF
62-63 - EP4.0.pdf PDF
3-6 - S2-3 - SECOND FLOOR FRAMING PLAN.pdf PDF
23-24 - A5-2 - MISCELLANEOUS DETAILS.pdf PDF
43-46 - HV1.0.pdf PDF
17-3 - S1-1 - GENERAL NOTES.pdf PDF
13-18 - A2-1 - 2ND 3RD FLR REFLECTED CLG PLANS.pdf PDF
28-31 - A8-3 - 1st FLOOR - FINISHES.pdf PDF
21-23 - A5-1 - MISCELLANEOUS STAIR DETAILS.pdf PDF
70-71 - CT5.1.pdf PDF
36-37 - PL1.1.pdf PDF
42-44 - FP1.1.pdf PDF
31-32 - A8-4 - 2nd Floor - FINISHES.pdf PDF
32-33 - A8-5 - 3rd Floor - FINISHES.pdf PDF
50-52 - HV2.1.pdf PDF
38-40 - PL1.4.pdf PDF
35-34 - PD1.0.pdf PDF
69-70 - CT4.1.pdf PDF
39-39 - PL1.3.pdf PDF
11-12 - A1-0 - BASEMENT DEMOLITION AND NEW WORK PLANS.pdf PDF
68-68 - CT1.0.pdf PDF
25-26 - A6-1 - ENLARGED PLANS AND INTERIOR ELEVATIONS.pdf PDF
63-64 - EL1.0.pdf PDF
65-66 - EL2.0.pdf PDF
2-2 - A0-1 - CODE INFO AND WALL TYPES.pdf PDF
9-14 - A1-2 - SECOND FLOOR DEMOLITION AND NEW WORK PLANS.pdf PDF
76-Elevator Inspection 2026-03-25-12-13-48.pdf PDF
58-59 - EP1.3.pdf PDF
46-47 - HV1.1.pdf PDF
57-58 - EP1.2.pdf PDF
61-62 - EP3.0.pdf PDF
80-438 Scott Full Inspection Report (PDF).pdf PDF
7-5 - S2-2 - FIRST FLOOR FRAMING PLAN.pdf PDF
53-54 - HV3.1.pdf PDF
4-9 - S3-1 - TYPICAL DETAILS.pdf PDF
1-4 - S2-1 - FOUNDATION PLAN.pdf PDF
24-25 - A6-0 - ENLARGED PLANS AND INTERIOR ELEVATIONS.pdf PDF
48-50 - HV1.4.pdf PDF
20-21 - A4-1 - BUILDING SECTIONS.pdf PDF
Show 40 more

Latest 50 of 80 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIELD VERIFY

1' - 7" ±

EX STONE MASONRY WALL

EX WOOD

FLOOR JOIST

TYP

EX HARDWOOD FLOORING

PROTECT FROM DAMAGE DURING

CONSTRUCTION

TYP

INSTALL WOOD SLEEPERS BETWEEN EX JOISTS

AT NEW FLOORING EDGES AND AS REQUIRED TO

ENSURE ALL HARDWOOD FLOORING PIECES ARE

SUPPORTED

SEE ARCH DWGS FOR

FLOOR PATCH CONSTRUCTION

ALONG TOP OF NEW CONC BEAM

CONT CONC BEAM

REINFORCE PER

DET R/S4.1

TEMPORARY SHORING BY CONTRACTOR

SEE NOTES ON S1.1 FOR REQUIREMENTS

TYP

CONC BEAM WIDTH SHALL

MATCH EX WALL WIDTH

NOTES:

1. PROPER CONSOLIDATION OF CONCRETE IS CRITICAL TO ENSURE

HONEYCOMBS, VOIDS, ETC. DO NOT OCCUR IN EXPOSED

CONCRETE FACES.

2. PROVIDE SMOOTH FORMED / GROUT CLEANED FINISH TO ALL

EXPOSED FACE OF CONCRETE BEAM.

3"

2" CLR 2" CLR

2" C

LR

NO CHAMFER

TYP

CONT 1 3/4x14 LVL W/ 5/8"øx4" EMBED EXP

(WEDGE) BOLTS @ 12" O.C. (MAX)

STAGGER TOP & BOT

TYP EA SIDE OF CONC BEAM

CUT EX JOIST CONNECT CUT

JOIST TO LEDGER W/ SIMPSON

U210R METAL CONNECTOR

(USING 10d NAILS)

TYP EA JOIST, EA SIDE OF CONC BEAM

PROVIDE CONT PLASTIC BARRIER

(4 MIL MIN) BETWEEN LVL FACE AND

CONCRETE SURFACE

TRIM TIGHT TO LVL

TYP

NOTE:

AFTER REMOVAL OF UPPER SHORING AND PRIOR

TO FASTENING THE JOIST HANGERS ADJUST

HIEGHT OF TEMPORARY SHORING IN BASEMENT TO

MAXIMIZE LEVELNESS BETWEEN JOISTS ON EACH

SIDE OF CONC BEAM. DO NOT ADJUST ELEVATION

BY MORE THAN 3".

2" 4"

EX HARDWOOD FLOORING

PROTECT FROM DAMAGE DURING

CONSTRUCTION

EX WOOD

FLOOR JOIST

TYP

CONT PRESERVATIVE

TREATED WOOD GIRDER

SEE PLAN FOR MEMBER SIZE

& SPLICE REQUIREMENTS

SIMPSON LCC4.5-3.5

METAL CONNECTOR AT

EACH COLUMN

STEEL COLUMN

SEE SCHEDULE

PROVIDE HARDWOOD

SHIM AS REQUIRED TO

CREATE BEARING

1/8

ATTACH BEAM TO EACH

EX JOIST W/ (2) DIAGONAL

SCREWS AS SHOWN

FIELD VERIFY

1' - 7" ±

EX HARDWOOD FLOORING

PROTECT FROM DAMAGE DURING

CONSTRUCTION

TYP

3"

POCKET CONT CONC BEAM AT COLUMN BASE

FILL POCKET WITH NON-METALLIC, NON-SHRINK

GROUT TO UNDERSIDE OF FLOOR CONSTRUCTION

AFTER STEEL COLUMN INSTALLATION

(AT COLUMN LOCATIONS ONLY)

SEE ARCH DWGS FOR

FLOOR PATCH CONSTRUCTION

ALONG TOP OF NEW CONC BEAM

SEE COLUMN SCHEDULE

FOR BASE PLATE

NOTE:

SEE DET A/S4.1 & B/S3.1 FOR

INFORMATION NOT SHOWN.

EM

BE

D M

EN

T

1'

6" M

IN

A

N C

H O

R

FIELD VERIFY

1' - 7" ±

EX MASONRY WALL

EX WOOD

FLOOR JOIST

TYP

EX HARDWOOD FLOORING

PROTECT FROM DAMAGE DURING

CONSTRUCTION

TYP

TEMPORARY SHORING

BY CONTRACTOR

SEE NOTES ON S1.1

FOR REQUIREMENTS

CONT PL 1/2 x

WALL THICKNESS

(MATCH OUT-TO-OUT

WIDTH OF WALL

INCLUDING FINISH)

3/16 2-16

3/16 2-16

STEEL BEAM

SEE PLAN

TOP OF STEEL

ELEV = +11'-0"

WALL FINISH

TYP

EX WOOD

FLOOR JOIST

TYP

EX HARDWOOD FLOORING

PROTECT FROM DAMAGE DURING

CONSTRUCTION

5"

1"ø A307 THRU BOLT

@ 3'-6" O.C. (MAX)

EX WOOD GIRDER

INSTALL STEEL TIGHT TO

UNDERSIDE OF EX JOISTS

WHERE EX CONDITIONS PREVENT

JOISTS FROM BEARING ON STEEL

(SUCH AS NOTCHES OR UNEVEN

JOISTS) INSTALL HARDWOOD SHIMS

TO CREATE BEARING CONDITION.

STEEL GIRDER REINFORCEMENT CHANNEL

SEE PLAN, TYP

NOTE:

SEE DET G/S4.1 FOR CHANNEL TO

EX WOOD GIRDER BOLTS AT BEAM ENDS.

EX WOOD FLOOR JOIST

TYP

EX HARDWOOD FLOORING

PROTECT FROM DAMAGE DURING

CONSTRUCTION

1" ± 3/4" 1" ± 3/4"

EX WOOD COLUMN

EX WOOD COLUMN CAP

(6) 1"ø A307 THRU BOLTS

EA END OF BEAM

(SEE DETAIL GG FOR SPACING)

TYP

FIELD ADJUST DIM SUCH THAT NEW THRU BOLTS

DO NOT CONFLICT W/ EX VERT THRU BOLTS

SEE NOTE 2. FOR ADDITIONAL INFORMATION

STEEL GIRDER REINFORCEMENT CHANNEL

EACH SIDE OF EX WOOD GIRDER

SEE PLAN, TYP

SEE DET F/S4.1 FOR ADDITIONAL INFORMATION.

IF BOLT CONFLICT CANNOT BE AVOIDED AT BOTH ENDS OF

BEAM, NOTIFY ENGINEER, REMOVE EX VERT THRU BOLT AND

RE-INSTALL AT LOCATION DIRECTED BY ENGINEER. PROVIDE

NEW BOLT TO MATCH EX IF EX BOLT CANNOT BE REUSED.

EX WOOD GIRDER

9 1/2"±W x 11"±D + 1x CONT WOOD TOP PL

EX WOOD COLUMN

EX THRU BOLT

TYP

5" 4" 4" 4" 4" 4"

5" 3"

DETAIL GG

NOTE:

1.

2.

EX WOOD RAFTER

EX ROOF SHEATHING

NEW 15/32" APA OVERLAY

SHEATHING

SEE MEP & ARCH DWGS FOR

MECHANICAL UNIT, CURB, &

CHASE CONSTRUCTION

SEE ARCH DWGS FOR

NEW ROOF CONSTRUCTION

CONT 2x6 PLATE

ATTACH TO STEEL BEAM

PER DET G/S3.1

STEEL BEAM

SEE PLAN

(BEAM SLOPES TO

MATCH ROOF SLOPE)

CONT BAND BOARD

CONSTRUCT FROM (2) LAYERS 3/4"

APA SHEATHING CUT TO FIT

TIGHT BETWEEN ROOF SHEATHING

& CONT 2x PLATE

EX WOOD RAFTER

TYP

EX ROOF SHEATHING

NEW 15/32" APA OVERLAY

SHEATHING

SEE ARCH DWGS FOR

NEW ROOF CONSTRUCTION

CONT 2x6 PLATE

ATTACH TO STEEL BEAM

PER DET G/S3.1

STEEL BEAM

SEE PLAN

2x12 BLOCKING @ 48" O.C.

ALIGN ONE SIDE OF

MECH UNIT SUPPORT W/

EX RAFTER LOCATION

SEE PLAN

(OTHERWISE INSTALL

CONTINUOUS BAND

BOARD AND BLOCKING

AS SHOWN IN DET P/S4.1)

3"

1/2" GAP

1 1/2"

7"

(3) 3/4"ø A325-N BOLTS

PL 3/8x7x9

CANTILEVER WHERE

SHOWN IN PLAN

CAP PL 1/2x9x11

(4) 3/4"ø A325-N BOLTS @ 5 1/2"x5 1/2" GAGE

1/4

STEEL COLUMN

SEE SCHEDULE

STEEL BEAM

SEE PLAN

TYP

3/8" STIFF PLATE

EA SIDE OF BEAM WEB

CENTERED OVER COLUMN WEB

(4) 1/2"øx12" EMBED

ADHESIVE ANCHORS

@ 14"x18" GAGE

(OVER COLUMNS ONLY)

SLANT TO WALL INTERIOR

W/ TAPERED WASHERS

5/16

NOTE:

SEE DET D/S4.1 FOR

INFORMATION NOT SHOWN.

9" 9"

EX WOOD

ROOF RAFTER

TYP

STEEL GIRDER REINFORCEMENT CHANNEL

SEE PLAN, TYP

EX ROOF SHEATHING

NEW 15/32" APA OVERLAY

SHEATHING

SEE ARCH DWGS FOR

NEW ROOF CONSTRUCTION

SEE DET P/S3.1

STEEL BEAM

SEE PLAN

STEEL GIRDER REINFORCEMENT CHANNEL

SEE PLAN, TYP

EX ROOF SHEATHING

NEW 15/32" APA OVERLAY

SHEATHING

SEE ARCH DWGS FOR

NEW ROOF CONSTRUCTION

EX WOOD ROOF RAFTER

TYP

1"ø A307 THRU BOLT

@ 3'-6" O.C. (MAX)

EX WOOD GIRDER

INSTALL STEEL TIGHT TO

UNDERSIDE OF EX RAFTERS

WHERE EX CONDITIONS PREVENT

RAFTERS FROM BEARING ON STEEL

(SUCH AS NOTCHES OR UNEVEN

RAFTERS) INSTALL HARDWOOD SHIMS

TO CREATE BEARING CONDITION.

4"

NOTE:

SEE DET M/S4.1 FOR CHANNEL TO

EX WOOD GIRDER BOLTS AT BEAM ENDS.

EX WOOD ROOF RAFTER

TYP

EX WOOD COLUMN

EX WOOD COLUMN CAP

(4) 1"ø A307 THRU BOLTS

EA END OF BEAM

(SEE DETAIL MM FOR SPACING)

TYP

STEEL GIRDER REINFORCEMENT CHANNEL

EACH SIDE OF EX WOOD GIRDER

SEE PLAN, TYP

EX WOOD GIRDER

8"±W x 11"±D

EX THRU BOLT

TYP

5" 4" 4" 4"

4" 3"

DETAIL MM

FIELD ADJUST DIM SUCH THAT NEW THRU BOLTS

DO NOT CONFLICT W/ EX VERT THRU BOLTS

SEE NOTE 2. FOR ADDITIONAL INFORMATION

SEE DET L/S4.1 FOR ADDITIONAL INFORMATION.

IF BOLT CONFLICT CANNOT BE AVOIDED AT BOTH ENDS OF

BEAM, NOTIFY ENGINEER, REMOVE EX VERT THRU BOLT AND

RE-INSTALL AT LOCATION DIRECTED BY ENGINEER. PROVIDE

NEW BOLT TO MATCH EX IF EX BOLT CANNOT BE REUSED.

NOTE:

1.

2.

EX ROOF SHEATHING

NEW 15/32" APA OVERLAY

SHEATHING

SEE ARCH DWGS FOR

NEW ROOF CONSTRUCTION

1" ± 3/4" 1" ± 3/4"

EX WOOD

ROOF RAFTER

STEEL GIRDER REINFORCEMENT CHANNEL

SEE PLAN, TYP

EX ROOF SHEATHING

NEW 15/32" APA OVERLAY

SHEATHING

SEE ARCH DWGS FOR

NEW ROOF CONSTRUCTION

EX WOOD

ROOF GIRDER

CONT WOOD PLATE

SIZE TO FIT TIGHT

SEE ARCH DWGS FOR

ROOF HATCH CONSTRUCTION

EX WOOD ROOF RAFTER

SEE PLAN FOR SIMPSON

METAL CONNECTOR

(FOR SUPPORT OF EX RAFTER)

CONT (2) 2x12

CONNECT TO NEW LVL AT EACH

END W/ SIMPSON LUS210-2 METAL

CONNECTOR

NEW HEADER

SEE PLAN

EX WOOD RAFTER

TYP

EX ROOF SHEATHING

NEW 15/32" APA OVERLAY

SHEATHING

SEE ARCH DWGS FOR

NEW ROOF CONSTRUCTION

CONT 2x6 PLATE

ATTACH TO STEEL BEAM

PER DET G/S3.1

STEEL BEAM

SEE PLAN

SEE MEP & ARCH DWGS FOR

MECHANICAL UNIT, CURB, &

CHASE CONSTRUCTION

2x12 BLOCKING @ 48" O.C.

INSTALL ON BOTH SIDES OF

BAND BOARD OUTSIDE OF

AREA BELOW MECH UNIT

CONT BAND BOARD

CONSTRUCT FROM

(2) LAYERS 3/4" APA

SHEATHING CUT TO

MATCH ADJACENT

EX RAFTERS DEPTH

CENTERED BETWEEN GRIDS

5' - 2" LAP

5' - 2" LAP 5' - 2" LAP

5' - 2" LAP

CENTERED BETEWEEN GRIDS

5' - 2" LAP

5' - 2" LAP

CENTERED BETWEEN GRIDS

5' - 2" LAP

3" MAX

3" MAX

STD 90° HOOK

STD 90° HOOK

18" O.C. (MAX)

A B C D E

18" O.C. (MAX) 18" O.C. (MAX) 18" O.C. (MAX)

(4) #8 CONT

TOP & BOT

TYP

#3 CLOSED TIES

SPACED AS SHOWN

TYP

6" 6" 1' - 0" 1' - 0" 6" 6"1' - 0" 6" 6" 6" 6" 1' - 0" 1' - 0" 6" 6" 6" 6" 1' - 0"6" 6" 1' - 0" 1' - 0" 6" 6" 4"

ADHESIVE DOWELS

INTO EX WALL

SEE PLAN

ADHESIVE DOWELS

INTO EX WALL

SEE PLAN

12"ø BLOCKOUT FOR DUCT PENETRATION

SEE DET S/S4.1

2' - 7"

6" 1'

0"

12"ø BLOCKOUT IN

CONCRETE BEAM

W/ 1" COMPRESSIBLE

FILLER MATERIAL

APPROVED FOR PROGRAM CONCEPT ONLY

APPROVED FOR PROGRAM CONCEPT ONLY

DATE

DATE

ENGINEERING

DIVISION OF

AGENCY

AUTHORIZED AGENT

FOR INTENT ONLY

DIV. OF ENGR.

REVIEWED

ENGR. ACCT. NO.

DRAWING NO.

DATE

A&E FILE NO.

CHECKED BY

SHEET DRAWN BY

RECORD DATE

DATEREVISIONS

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES MANAGEMENT

DIVISION OF ENGINEERING

FRANKFORT, KENTUCKYDK

BSM

470-C5N5-NC11-01

PROFESSIONAL SERVICES CLASSROOM CENTER

RECORD DRAWINGS DATE: 12/18/2015

BROWN & KUBICAN, PSC.

These record drawings have been prepared, in part, on the basis of information compiled and furnished by others. The Engineers has not verified the accuracy and/or completeness of this information and shall not be responsible for any errors or omissions that may be incorporated as a result of erroneous information provided by others.

/3

/2

:3 5:

A

M C

:\U se rs \b m cm ill an

\D es kt op

\L oc al F ile s\

\ 1

_0

G C

T C

A bo de

B K

L

O C

A L

B

S M

S

3.

rv t

S4.1

FRAMING DETAILS

GATEWAY URBAN CAMPUS

438-440 Scott St., Covington, KY 41011

01/06/14

201114.02

SECTION

3/4" = 1'-0"S4.1

A SECTION

3/4" = 1'-0"S4.1

CSECTION

3/4" = 1'-0"S4.1

B SECTION

3/4" = 1'-0"S4.1

D

SECTION

3/4" = 1'-0"S4.1

F SECTION

3/4" = 1'-0"S4.1

G SECTION

3/4" = 1'-0"S4.1

H

SECTION

3/4" = 1'-0"S4.1

N

SECTION

3/4" = 1'-0"S4.1

E

SECTION

3/4" = 1'-0"S4.1

K SECTION

3/4" = 1'-0"S4.1

L SECTION

3/4" = 1'-0"S4.1

MSECTION

3/4" = 1'-0"S4.1

J

SECTION

3/4" = 1'-0"S4.1

P

1/4" = 1'-0"S4.1

R CONCRETE BEAM REINFORCING

NOT TO SCALES4.1

S DUCT PENETRATION THRU CONCRETE BEAM

File details come from the government source that posted it. Updated .