68-68 - CT1.0.pdf
PDF 423 KB Posted
- Solicitation number
- RFP260305
- Issued by
- Hart County, Kentucky
About this file
This is an architectural floor plan and communication technology infrastructure drawing prepared by the Commonwealth of Kentucky's Finance and Administration Cabinet, Department for Facilities & Support Services, Division of Engineering, in collaboration with KLH Engineers, PSC. The project involves the Gateway Urban Campus located at 438-440 Scott Street in Covington, Kentucky, and details communication technology infrastructure for new basement and first floor installations. The plan specifies the layout of multiple functional spaces including a student lounge, cosmetology salon, reception area, waiting area, consultation room, manicure/pedicure area, dispensary, corridors, restrooms, storage, and custodial areas across the basement and first floors.
The drawing indicates specific infrastructure requirements including a communications room (noted as item 50), equipment swing cabinet (item 51), and dedicated power provisions for future cabinet and equipment (item 52). Critical coordination notes require integration with Cincinnati Bell for a 4-inch communication utility service entrance conduit from an existing manhole, with pathways designed to accommodate both fiber optic and copper service entrance to the backboard demarcation location. The plan also specifies 4-inch vertical conduit sleeves from floor to floor for horizontal and backbone cabling pathways, with minimum quantities shown but additional quantities to be provided as required to maintain 40-percent maximum fill capacity and ensure proper cable separation. The document was approved for program concept only as of December 18, 2015, with professional services coordination managed by KLH Engineers under project number 11369.04.
View the file
Other files
Show 40 more
Latest 50 of 80 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C
C
C
C
C C
C
C
C
C
C
C
C
KP
KP
B C D EA G
F
STUDENT LOUNGE
EF / ER
EXISTING STORAGE
EXISTING MECHANICAL
ROOM
EXISTING ELEVATOR
MACHINE ROOM
EXISTING STAIR
A
EXISTING ELEVATOR
E
WAP
ELEV
B C D EA G
F
HVAC
DISPENSARY
CORRIDOR
100B
COSMETOLOGY SALON
WAITING AREA
RECEPTION
100A
CONSULTATION
100C
MANICURE/PEDICURE
AREA
100D
EXISTING STAIR
B
STAIR
D1
MEN
WOMEN
STORAGE
CORRIDOR
100E
CUSTODIAL
WAP
WAP
84" AFF
1D
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DATE
DATE
ENGINEERING
DIVISION OF
AGENCY
AUTHORIZED AGENT
FOR INTENT ONLY
DIV. OF ENGR.
REVIEWED
ENGR. ACCT NO.
DRAWING NO.
DATE
A&E FILE NO.
CHECKED BY
SHEET DRAWN BY
RECORD DATE
DATEREVISIONS
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING
FRANKFORT, KENTUCKY
WWW.KLHENGRS.COM
ENGINEERS, PSC
MECHANICAL/ELECTRICAL ENGINEERS
KOHRS LONNEMANN HEIL
LEXINGTON, KENTUCKY
COLUMBUS, OHIO
DAYTON, OHIO
NEW YORK, NEW YORK
1538 ALEXANDRIA PIKE, SUITE
11 FT. THOMAS, KENTUCKY
41075 800-354-9783 859-442-8050
859-442-8058 FAX
KLH PRO. NO.
11369.04
PROFESSIONAL SERVICES CLASSROOM CENTER
/1
/2
:4 :4
A
M
CT1.0
COMMUNICATION TECH. - NEW -
BASEMENT AND 1ST FLOORS
470-C5N5-NC11-01
GATEWAY URBAN CAMPUS
438-440 Scott St., Covington, KY 41011
12/18/15
201114.02
Author
Checker
KEYED NOTES
50 COMMUNICATIONS ROOM. SEE ENLARGED FLOOR PLAN FOR
ADDITIONAL INFORMATION AND REQUIREMENTS.
51 EQUIPMENT SWING CABINET. SEE ENLARGED FLOOR PLAN FOR
ADDITIONAL INFORMATION.
52 PROVIDE DEDICATED POWER FOR FUTURE CABINET AND
EQUIPMENT.
53 COORDINATE WITH CINCINNATI BELL FOR 4-INCH COMMUNICATION
UTILITY SERVICE ENTRANCE CONDUIT(S) FROM EXISTING
MANHOLE. COORDINATE WITH ALL TRADES. PATHWAYS SHALL
ACCOMMODATE FIBER OPTIC AND COPPER SERVICE ENTRANCE
TO BACKBOARD DEMARCATION LOCATION. SEE ENLARGED PLAN
AND DETAILS.
54 4-INCH VERTICAL CONDUIT SLEEVES (FROM FLOOR BELOW TO
ABOVE ACCESSIBLE CEILING) FOR HORIZONTAL AND BACKBONE
CABLING PATHWAYS. MINIMUM QUANTITIES SHOWN. PROVIDE
ADDITIONAL QUANTITIES AS REQUIRED FOR CABLE SEPARATION
AND 40-PERCENT MAXIMUM FILL CAPACITY. COORDINATE WITH ALL
TRADES.
SCALE: 1/4" = 1'-0"CT1.0
1 COMMUNICATION TECHNOLOGY - NEW - BASEMENT FLOOR
SCALE: 1/4" = 1'-0"CT1.0
2 COMMUNICATION TECHNOLOGY - NEW - 1ST FLOOR
NORTH
PLAN
6 PR-027 - Classroom
201 Power and Data
12/09/2014
File details come from the government source that posted it. Updated .