57-58 - EP1.2.pdf
PDF 1 MB Posted
- Solicitation number
- RFP260305
- Issued by
- Hart County, Kentucky
About this file
This is an electrical power design plan prepared by the Commonwealth of Kentucky's Department for Facilities & Support Services, Division of Engineering, in collaboration with KLH Engineers for the Gateway Urban Campus located at 438-440 Scott Street in Covington, Kentucky. The document provides detailed electrical power specifications for the second floor of a classroom center, including new installations and demolition requirements. The plan specifies power distribution to multiple spaces including a classroom (201), facial/couple massage room (207), dispensary (204), restrooms (208 and women's facilities), offices (203 and 205), corridors, and a closet. The design incorporates various circuit capacities ranging from 12 amps to 35.37 amps, specialized receptacles including recessed activation floor boxes with single and double duplex configurations, GFCI protection for specific areas, lighting provisions with candela ratings of 15 to 75 cd, and an exhaust fan controlled with room lighting via occupancy sensors.
The electrical plan was approved for program concept as of December 18, 2015, with professional services coordination between the Division of Engineering, authorized agents, and KLH Engineers. The design emphasizes coordination with architectural furniture drawings prior to rough-in work and specifies that existing pathways and backboxes may be reused on existing walls where possible, with new conduit concealed within walls rather than surface-mounted. All electrical devices, panels, power, lighting, fire alarm, and communication equipment designated for demolition shall be removed entirely unless specifically marked as existing or to remain, with protection required during demolition. The plan mandates that wall receptacles be centered in 8-inch baseboards horizontally and that no damage occur to existing first-floor tin ceilings, with East/West dimensional allowances of plus or minus 6 inches pending floor joist locations.
View the file
Other files
Show 40 more
Latest 50 of 80 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T
T
T
T
T
T
T
S
J
J
T
T
SS
S
S
S S
S
B C D EA G
F
2A
EWC
CLASSROOM
FACIAL / COUPLE
MASSAGE
STAIR
D2DISPENSARY
MEN
WOMEN
CUST.
206A
EXISTING STAIR
C2
OFFICE 2
OFFICE 1
CORRIDOR
WASHER
DRYER
PROJ.
GFCI
- 22A
- 3,52A
- 42A
- 62A
- 72A
- 82A
- 92A
- 102A
- 142A
- 112A
- 122A
75 cd
75 cd 30 cd
30 cd
75 cd 75 cd
75 cd
75 cd
CORRIDOR
200A
CLOSET
EXISTING STAIR
B2
ACU-2-04
HRB-04
ACU-2-05
ACU-2-03
HRB-03
HRB-05
HRB-19
ACU-2-01DACU-2-01CACU-2-01BACU-2-01A
HRB-01
HRB-18
HRB-17
HRB-06
ACU-2-06B
ACU-2-06A
ACU-2-07
HRB-07
HRB-16
ACU-2-08
EF-2
P-3- 212A
GFCI
GFCI
- 31,332A
- 31,332A
- 31,332A
- 35,372A
- 35,372A
- 35,372A
- 35,372A
- 322A
GFCI GFCI
30 cd
15 cd
- 132A
- 12A
FUTURE
HAND
DRYER
- 342A
FUTURE
HAND
DRYER
- 362A
2C
- 22C
- 12C
- 42C
- 32C
- 82C
- 72C
- 62C
- 52C
- 122C
- 112C
- 102C
- 92C
- 162C
- 152C
- 142C
- 132C
- 202C
- 192C
- 182C
- 172C
- 242C
- 232C
- 222C
- 212C
- 282C
- 272C
- 262C
- 252C
- 322C
- 312C
- 302C
- 292C
- 352C
- 332C
- 362C
- 342C
- 382C
- 372C
- 402C
- 392C
RECOMMENDED MC PATH
FISHED BETWEEN JOISTS
(TYPICAL)
TYPE MC SHALL ONLY BE
ALLOWED FROM A JUNCTION
BOX ABOVE THE ACCESSIBLE
CEILING, TO THE FLOORBOX.
SECURE PER NEC 330.30.
UP UP UP
UP
RUN IN WALL
BELOW WINDOW
1' - 8"
8' - 1"
0' - 6"
5' - 2"5' - 6" 5' - 4"
0' - 7"
5' - 6" 5' - 5" 5' - 7" 2' - 2"
B C D EA G
F
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DATE
DATE
ENGINEERING
DIVISION OF
AGENCY
AUTHORIZED AGENT
FOR INTENT ONLY
DIV. OF ENGR.
REVIEWED
ENGR. ACCT NO.
DRAWING NO.
DATE
A&E FILE NO.
CHECKED BY
SHEET DRAWN BY
RECORD DATE
DATEREVISIONS
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING
FRANKFORT, KENTUCKY
WWW.KLHENGRS.COM
ENGINEERS, PSC
MECHANICAL/ELECTRICAL ENGINEERS
KOHRS LONNEMANN HEIL
LEXINGTON, KENTUCKY
COLUMBUS, OHIO
DAYTON, OHIO
NEW YORK, NEW YORK
1538 ALEXANDRIA PIKE, SUITE
11 FT. THOMAS, KENTUCKY
41075 800-354-9783 859-442-8050
859-442-8058 FAX
KLH PRO. NO.
11369.04
PROFESSIONAL SERVICES CLASSROOM CENTER
/1
/2
:1 :1
P
M
EP1.2
ELECTRIC POWER - NEW AND
DEMOLITION - 2ND FLOOR
470-C5N5-NC11-01
GATEWAY URBAN CAMPUS
438-440 Scott St., Covington, KY 41011
12/18/15
201114.02
DTJ
SNF
SCALE: 1/4" = 1'-0"EP1.2
1 ELECTRIC POWER - NEW - 2ND FLOOR
SCALE: 1/4" = 1'-0"EP1.2
2 ELECTRIC - DEMOLITION - 2ND FLOOR
KEYED NOTES
3 PROVIDE POWER ONLY (SINGLE DUPLEX RECEPTACLE) RECESSED
ACTIVATION FLOOR BOX. COORDINATE EXACT LOCATION WITH
ARCHITECTURAL FURNITURE DRAWINGS PRIOR TO ROUGH IN.
7 EXHAUST FAN TO BE CONTROLLED ALONG WITH ROOM LIGHTING.
TIE INTO LIGHTING CONTROL CIRCUIT. PROVIDE ADDITIONAL
OCCUPANCY SENSOR RELAY PACKS AS REQUIRED.
14 PROVIDE POWER ONLY (DOUBLE DUPLEX RECEPTACLE)
RECESSED ACTIVATION FLOOR BOX. PROVIDE A SINGLE 20A
CIRCUIT TO EACH DUPLEX. COORDINATE EXACT LOCATION WITH
ARCHITECTURAL FURNITURE DRAWINGS PRIOR TO ROUGH IN.
DEMOLITION GENERAL NOTES
A. ALL ELECTRICAL (POWER, LIGHTING, FIRE ALARM, AND COMMUNICATION)
DEVICES, PANELS, ETC. SHALL BE DEMOLISHED IN THEIR ENTIRETY
UNLESS OTHERWISE INDICATED TO BE RELOCATED OR TO REMAIN
(INDICATED AS EXISTING). ALL DEVICES NOTED TO REMAIN SHALL BE
PROTECTED DURING DEMOLITION. SEE SPECIFICATIONS FOR ADDITIONAL
DEMOLITION NOTES.
GENERAL NOTES
A. EXISTING PATHWAYS AND BACKBOXES MAY BE RE-USED ON EXISTING
WALLS TO REMAIN WHERE POSSIBLE. WHERE NOT POSSIBLE, NEW
BOXES AND CONDUIT SHALL BE CONCEALED WITHIN WALLS. SURFACE
MOUNTING SHALL NOT BE USED. COORDINATE WITH GENERAL
CONTRACTOR AND PATCH / REPAIR WALLS AS NEEDED TO RECESS
PATHWAYS AND BOXES.
B. ALL WALL RECEPTACLES TO BE INSTALLED CENTERED IN 8"
BASEBOARDS (HORIZONTALLY) UNLESS SHOWN AS ABOVE COUNTER
OR NOTED OTHERWISE.
C. DO NO DAMAGE EXISTING FIRST FLOOR TIN CEILING.
NORTH
PLAN
EAST / WEST DIMENSIONS MAY SHIFT +/- 6 INCHES
DEPENDING ON FLOOR JOIST LOCATIONS
3 PR-016 - Styling Stations
8/8/2014
4 Electrical Dimensions 9/18/2014
6 PR-027 - Classroom 201 Power and Data
12/09/2014