20-21 - A4-1 - BUILDING SECTIONS.pdf
PDF 444 KB Posted
- Solicitation number
- RFP260305
- Issued by
- Hart County, Kentucky
About this file
This file is a set of building section drawings for the Gateway Urban Campus professional services classroom center located at 438-440 Scott Street in Covington, Kentucky, prepared by the Commonwealth of Kentucky Finance and Administration Cabinet, Department for Facilities Management, Division of Engineering. The document contains schematic architectural drawings approved for program concept only, dated September 25, 2014, with record drawings updated as of December 18, 2015. The building sections illustrate a multi-story structure with basement, first, second, and third floors, plus roof level, with detailed floor plans identifying various functional spaces including massage clinical labs, cosmetology salon, freshman clinic, dispensary, manicure/pedicure areas, corridors, and mechanical rooms distributed across the levels. The drawings reference structural components, existing conditions, and stairs located at multiple points throughout the building.
The technical sections of the drawings provide detailed specifications for roof construction, including SBS modified bitumen membranes, polyisocyanurate insulation, roof curbs, plumbing vent stacks, roof drains, and parapet cap details at the existing masonry wall interfaces. The construction specifications reference structural drawings for roof sheathing and wood joist framing, with materials including galvanized steel components, pre-finished aluminum parapet caps, exterior grade plywood substrates, and pressure-treated wood nailers. The document notes that building sections are for schematic representation only and includes a disclaimer that record drawings were prepared in part on the basis of information compiled by others, with no verification of accuracy or completeness provided by the architect/engineer.
View the file
Other files
Show 40 more
Latest 50 of 80 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A4.0
A4.0
B C D EA G
A4.1
A4.1
MASSAGE
CLINICAL LAB
OFFICE
302C
STAIR
D3
STAIR
D2
STAIR
D1
DISPENSARY
COSMETOLOGY
SALON
FRESHMAN CLINIC
DISPENSARY
EXISTING
MECHANICAL
ROOM
F
A5.0
ACOUSTICAL BATT INSULATION,
REFER TO NOTE # 8 ON SHEET A2.1
BUILDING SECTIONS ARE FOR
SCHEMATIC REPRESENTATION ONLY
A2.1
1ST FLOOR
0' - 0"
2ND FLOOR
16' - 2"
0 basement -10' - 8"
3RD FLOOR
29' - 5" roof 42' - 3"
1ST FLOOR REAR
0' - 10"
A4.1
A4.1
A4.0
A4.0
1 3
CLIENT MASSAGE
301A
CORRIDOR
ROOF ACCESS
302B
MASSAGE
CLINICAL LAB
EXISTING STAIR
C2
FRESHMAN CLINIC
MANICURE/PEDICURE
AREA
100D
CORRIDOR
100B
COSMETOLOGY
SALON
EXISTING
MECHANICAL
ROOM
EXISTING STORAGE
ACOUSTICAL BATT INSULATION
REFER TO NOTE # 8 ON SHEET A2.1
A2.1
TOP OF FLANGE CAPPED OR ROLLED
ONTO PIPE 1"
6" MINIMUM FLANGE SET IN MULTI-
PURPOSE MB FLASHING CEMENT
OVER FIELD PLIES- PRIME
FLANGE BEFORE STRIPPING
GRANULE SURFACE SBS
MODIFIED BITUMEN CAP
SHEET
BASE AND INTERPLY SHEETS AS
REQUIRED PER SPECIFICATIONS
FOR WARRANTY
SOFT METAL PIPE FLASHING
PLUMBING VENT STACK
MULTI-PURPOSE MB
FLASHING CEMENT
1/2" HIGH DENSITY POLYISO-
CYANURATE COVERBOARD
OVER 3" MIN. THICKNESS
POLYISOCYANURATE
CL
1' - 0" +/- 1' - 0" +/-
NEW ROOF SHEATHING
REFER TO STRUCTURAL
DRAWINGS
EXISTING ROOF WOOD
JOISTS AND SHEATHING
PT WOOD NAILER
REMOVABLE SHEET METAL
COUNTERFLASHING WITH
DRIP EDGE
MULTIPLE-PLY
MEMBRANE BASE
FLASHING
SBS MODIFIED BITUMEN
ROOF MEMBRANE
1/2" HIGH DENSITY
POLYISOCYANURATE
COVERBOARD OVER
3" MIN. THICK POLYISO-
CYANURATE
FRT WOOD
NAILERS
RAISED CURB
SEALING MATERIAL
CANT
NEW ROOF SHEATHING
REFER TO STRUCTURAL
DRAWINGS
EXISTING ROOF WOOD
JOIST AND SHEATHING
EXISTING ROOF WOOD
JOIST AND SHEATHING
NEW ROOF SHEATHING
REFER TO STRUCTURAL
DRAWINGS
NEW 2X12 WOOD JOIST
FRAMING, REFER TO
STRUCTURAL DWGS
STRAINER BASKET
COMPRESSION RING
30" SQUARE MINIMUM SOFT
METAL FLASHING (PRIME TOP
SURFACE BEFORE STRIPPING)
MULTI-PURPOSE FLASHING CEMENT
POLYISO TAPERED EDGE, 1" PER
FOOT MAX. SLOPE
INTERPLY LAYERS AS
REQUIRED BY
SPECIFICATIONS
SBS MODIFIED BITUMEN
GRANULE SURFACED
CAP SHEET
POLYISOCYANURATE - MINIMUM
THICKNESS 3"
NEW ROOF SHEATHING REFER
TO STRUCTURAL DRAWINGS
1/2" HIGH DENSITY
POLYISO-CYANURATE
COVERBOARD
EXTEND ALL PLIES,
FLASHING AND CAP
SHEET INTO
COMPRESSION
RING FOR A
MINIMUM OF 1/2"
PROVIDE STEEL
ANGLE AT DECK FOR
COMPRESSION RING
ATTACHMENT
CL
1' - 0" +/-
CENTER ROOF DRAIN
BETWEEN EXISTNG
ROOF JOISTS
EXISTING ROOF WOOD
JOISTS AND SHEATHING
WALL (F.V.)
EXISTING MASONRY
/2
/2
SLOPE TO ROOF
PRE-FINISHED
ALUMINUM PARAPET
CAP, WITH DRIP EDGE
CONT. SEALANT
EXTEND ROOFING
MEMBRANE UP WALL
ROOFING MEMBRANE
TO EXTEND OVER
BOTH FACES OF WALL
GALV. STEEL
ANCHOR PLATE
SECURED TO
WOOD NAILERS
CONT. SEALANT
3/4" EXT. GRADE
PLYWOOD SUBSTRATE
SECURE TO EXISTING
WALL
2x P.T. WOOD NAILERS
SECURED TO PLYWOOD
SUBSTRATE
C
COMMONWEALTH
T
R E
R
A
H C
I
N K E
UT
OF
B
3 87
I
R E G
No.
TS E
NT U
C E
YK T
N E R
D
ER
RB
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DATE
DATE
ENGINEERING
DIVISION OF
AGENCY
AUTHORIZED AGENT
FOR INTENT ONLY
DIV. OF ENGR.
REVIEWED
ENGR. ACCT. NO.
DRAWING NO.
DATE
A&E FILE NO.
CHECKED BY
SHEET DRAWN BY
RECORD DATE
DATEREVISIONS
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES MANAGEMENT
DIVISION OF ENGINEERING
FRANKFORT, KENTUCKY
/5
/2
:5 :0
P
M C
U s e rs
\R H in s o n \D o c u m e n ts
\1
G
C T
C
A b o d e B u il d in g R e n o v a ti o n rh in s o n .r v t
A4.1
BUILDING SECTIONS
470-C5N5-NC11-01
GATEWAY URBAN CAMPUS
09/25/14
201114.02
BB
REH
PROFESSIONAL SERVICES CLASSROOM CENTER
438-440 Scott St., Covington, KY 41011
SCALE: 1/4" = 1'-0"A4.1
1 BUILDING SECTION 3
SCALE: 1/4" = 1'-0"A4.1
2 BUILDING SECTION 4
SCALE: 3" = 1'-0"A4.1
3 PLUMBING VENT - TYPICAL
SCALE: 3" = 1'-0"A4.1
4 ROOF CURB - TYPICAL
SCALE: 3" = 1'-0"A4.1
5 ROOF DRAIN
SCALE: 3" = 1'-0"A4.1
6 PARAPET CAP @ EXISTING WALL
AS-BUILT
12-18-15
RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED IN PART, ON THE BASIS OF INFORMATION COMPILED BY OTHERS. THE ARCHITECT/ENGINEER HAS NOT VERIFIED THE ACCURACY OR COMPLETENESS OF THE INFORMATION, AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS THAT MAY BE
INCORPORATED AS A RESULT OF ERRONEOUS INFORMATION PROVIDED BY OTHERS.