This is a set of record framing detail drawings prepared by Brown & Kubican, PSC for the Commonwealth of Kentucky Finance and Administration Cabinet, Department for Facilities Management, Division of Engineering. The drawings document structural framing specifications for the Gateway Urban Campus located at 438-440 Scott Street in Covington, Kentucky. The document contains thirteen detailed sections (S4.2 A through S4.2 N) at a scale of 3/4" = 1'-0", illustrating connections and construction methodologies for floor joists, steel beam installations, temporary shoring requirements, firestop construction, and stair framing systems. Key construction elements include the protection of existing hardwood flooring during construction, the installation of steel beams with wood shims and adhesive anchors, the use of Simpson LUS310 metal connectors for joist fastening, and coordination requirements with stair framing systems designed by the stair supplier. The drawings reference architectural drawings for rated shaft wall construction, fire-rated landing closures, and mechanical unit installations. All sections specify field verification of elevations and provide detailed notes regarding material specifications, fastening methods using A307 and A325-N bolts, and blocking requirements spaced at 8-foot on-center maximum intervals.

The record drawings were approved for program concept only and dated January 6, 2014, with engineering division review and authorization documented as of December 18, 2015. The drawings acknowledge that the record documents were prepared in part on information compiled and furnished by others, with the engineers noting non-responsibility for errors or omissions resulting from erroneous information provided by third parties. No pricing, funding sources, or contractual terms are specified within the technical framing details document.

View the file

Other files

File Type Posted
66-67 - CT0.0.pdf PDF
51-49 - HV1.3.pdf PDF
8-13 - A1-1 - FIRST FLOOR DEMOLITION AND NEW WORK PLANS.pdf PDF
34-35 - PD1.1.pdf PDF
30-30 - A8-2 - Basement - FINISHES.pdf PDF
29-29 - A8-1 - ROOM FINISH PLANS (N-I-C- FURNITURE LAYOUT).pdf PDF
15-8 - S2-5 - ROOF FRAMING PLAN.pdf PDF
73-19 - A3-0 - BUILDING ELEVATIONS.pdf PDF
49-51 - HV2.0.pdf PDF
72-72 - CT5.2.pdf PDF
67-69 - CT1.2.pdf PDF
62-63 - EP4.0.pdf PDF
3-6 - S2-3 - SECOND FLOOR FRAMING PLAN.pdf PDF
23-24 - A5-2 - MISCELLANEOUS DETAILS.pdf PDF
43-46 - HV1.0.pdf PDF
17-3 - S1-1 - GENERAL NOTES.pdf PDF
13-18 - A2-1 - 2ND 3RD FLR REFLECTED CLG PLANS.pdf PDF
28-31 - A8-3 - 1st FLOOR - FINISHES.pdf PDF
21-23 - A5-1 - MISCELLANEOUS STAIR DETAILS.pdf PDF
70-71 - CT5.1.pdf PDF
36-37 - PL1.1.pdf PDF
42-44 - FP1.1.pdf PDF
31-32 - A8-4 - 2nd Floor - FINISHES.pdf PDF
32-33 - A8-5 - 3rd Floor - FINISHES.pdf PDF
50-52 - HV2.1.pdf PDF
38-40 - PL1.4.pdf PDF
35-34 - PD1.0.pdf PDF
69-70 - CT4.1.pdf PDF
39-39 - PL1.3.pdf PDF
11-12 - A1-0 - BASEMENT DEMOLITION AND NEW WORK PLANS.pdf PDF
68-68 - CT1.0.pdf PDF
25-26 - A6-1 - ENLARGED PLANS AND INTERIOR ELEVATIONS.pdf PDF
63-64 - EL1.0.pdf PDF
19-10 - S4-1 - FRAMING DETAILS.pdf PDF
65-66 - EL2.0.pdf PDF
2-2 - A0-1 - CODE INFO AND WALL TYPES.pdf PDF
9-14 - A1-2 - SECOND FLOOR DEMOLITION AND NEW WORK PLANS.pdf PDF
76-Elevator Inspection 2026-03-25-12-13-48.pdf PDF
58-59 - EP1.3.pdf PDF
46-47 - HV1.1.pdf PDF
57-58 - EP1.2.pdf PDF
61-62 - EP3.0.pdf PDF
80-438 Scott Full Inspection Report (PDF).pdf PDF
7-5 - S2-2 - FIRST FLOOR FRAMING PLAN.pdf PDF
53-54 - HV3.1.pdf PDF
4-9 - S3-1 - TYPICAL DETAILS.pdf PDF
1-4 - S2-1 - FOUNDATION PLAN.pdf PDF
24-25 - A6-0 - ENLARGED PLANS AND INTERIOR ELEVATIONS.pdf PDF
48-50 - HV1.4.pdf PDF
20-21 - A4-1 - BUILDING SECTIONS.pdf PDF
Show 40 more

Latest 50 of 80 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EX WOOD

FLOOR JOIST

EX HARDWOOD FLOORING

PROTECT FROM DAMAGE DURING

CONSTRUCTION

2x12 BLOCKING BETWEEN

EACH CUT FLOOR JOIST

STEEL BEAM

SEE PLAN

CUT EX JOISTS TO BE FLUSH

W/ EDGE OF CONT 2x PLATE

CONT 2x6 WOOD PLATE

FASTEN TO BEAM PER DET G/S3.1

SEE ARCH DWGS FOR

RATED SHAFT WALL CONSTRUCTION

TYP

SEE ARCH DWGS FOR REQUIRED

FIRESTOP CONSTRUCTION AT EACH SPACE

STAIR FRAMING SYSTEM &

SUPPORT CONNECTIONS

TO BE DESIGNED BY STAIR SUPPLIER

STEEL BEAM

SEE PLAN

PROVIDE WOOD SHIM AS

REQUIRED TO CREATE

BEARING

FINISHED THIRD FLOOR

FIELD VERIFY ELEV

F.

V.

F.

V.

C O

O R

D

IN

AT

E

W / S

TA

IR

F R

AM

IN

G C

O N

ST

R

U C

TI

O

N

FASTEN JOIST TO CONT WOOD PL

W/ (3) 8d TOE NAILS

EX WOOD

FLOOR JOIST

EX HARDWOOD FLOORING

PROTECT FROM DAMAGE DURING

CONSTRUCTION

STEEL BEAM

SEE PLAN

SEE ARCH DWGS FOR

RATED SHAFT WALL CONSTRUCTION

TYP

SEE ARCH DWGS FOR REQUIRED

FIRESTOP CONSTRUCTION AT EACH SPACE

SHORE & CUT EX WOOD JOIST

FASTEN TO NEW SUPPORT W/

SIMPSON LUS310 METAL CONNECTOR

ADD SHIMS TO SIDE OF JOIST AT

CONNECTOR TO CREATE TIGHT FIT

N O

TC

H

2" M

AX

S-3.0 SLAB

CONSTRUCTION

3" E.O.S.

CONT L3x3x1/4

FINISHED THIRD FLOOR

FIELD VERIFY ELEV

CONT (2) 2x12

BEAR ON BOT BEAM FLANGE

BEVEL BOT OF INSIDE MEMBER

TO AVOID CONFLICT W/ STEEL

BEAM RADIUS

1/2"ø A307 THRU BOLTS

(W/ WASHERS) @ 12" O.C.

STAGGER TOP & BOT

3/16 2-16 6"

1/

2"

TEMPORARY SHORING

BY CONTRACTOR

SEE NOTES ON S1.1

FOR REQUIREMENTS

EX WOOD FLOOR JOIST

TYP

EX HARDWOOD FLOORING

PROTECT FROM DAMAGE DURING

CONSTRUCTION

SEE ARCH DWGS FOR

RATED SHAFT WALL CONSTRUCTION

TYP

SEE ARCH DWGS FOR REQUIRED

FIRESTOP CONSTRUCTION AT BEAM FACE

CONT L3x3x1/4

(FOR EXTENT OF LANDING)

STEEL BEAM

SEE PLAN

TYP

S-3.0 SLAB

CONSTRUCTION

FINISHED THIRD FLOOR

FIELD VERIFY ELEV

3/16 2-12

3" E.O.S.

NEW LVL SUPPORT

ALONG FLOOR EDGE

SEE PLAN

2x12 BLOCKING SPACED

TO MATCH EX JOIST

BRIDGING LOCATIONS

(8' O.C. MAX)

EX HARDWOOD FLOORING

PROTECT FROM DAMAGE DURING

CONSTRUCTION

SEE ARCH DWGS FOR

RATED SHAFT WALL

CONSTRUCTION

TYP

STEEL BEAM

SEE PLAN

FINISHED THIRD FLOOR

FIELD VERIFY ELEV3"

EX WOOD FLOOR JOIST

TYP

SEE ARCH DWGS FOR REQUIRED

FIRESTOP CONSTRUCTION AT BEAM FACE

NEW LVL SUPPORT

ALONG FLOOR EDGE

SEE PLAN

2x12 BLOCKING SPACED

TO MATCH EX JOIST

BRIDGING LOCATIONS

(8' O.C. MAX)

1/2"øx6" EMBED

ADHESIVE ANCHORS

@ 24" O.C.

STAGGER TOP & BOT

2" 3"

S-3.0 SLAB

CONSTRUCTION

MATCH EX FINISHED FLOOR

FIELD VERIFY ELEV

SEE DET

L/S3.1

STEEL BEAM

SEE PLAN

TYP

EX LOAD BEARING

MASONRY WALL

2"

1/2"øx6" EMBED

ADHESIVE ANCHORS

@ 16" O.C. (MAX)

MIN (3) PER MEMBER

S-3.0 SLAB

CONSTRUCTION

MATCH EX FINISHED FLOOR

FIELD VERIFY ELEV

STEEL BEAM

SEE PLAN

TYP

EX LOAD BEARING

MASONRY WALL

EX WOOD

FLOOR JOIST

TYP

EX HARDWOOD FLOORING

PROTECT FROM DAMAGE DURING

CONSTRUCTION

STEEL BEAM

SEE PLAN

SEE ARCH DWGS FOR

RATED SHAFT WALL CONSTRUCTION

TYP

SEE ARCH DWGS FOR REQUIRED

FIRESTOP CONSTRUCTION AT BEAM FACE

TYP

STEEL BEAM

SEE PLAN

SEE ARCH DWGS FOR

FIRE RATED LANDING CLOSURE

(RESTROOM CEILING)

EX SUB-FLOOR

WOOD SHEATHING

NEW CONT 2x

RIP TO FIT TIGHT BETWEEN

FLOORING LAYERS

(WHERE / IF APPLICABLE)

3"

STAIR FRAMING SYSTEM &

SUPPORT CONNECTIONS

TO BE DESIGNED BY STAIR SUPPLIER

FINISHED SECOND FLOOR

FIELD VERIFY ELEV

F.

V.

C O

O R

D

IN

AT

E

W / S

TA

IR

F R

AM

IN

G C

O N

ST

R

U C

TI

O

N

NEW 2x SUPPORT

ALONG FLOOR EDGE

SEE PLAN

2x12 BLOCKING SPACED

TO MATCH EX JOIST

BRIDGING LOCATIONS

(8' O.C. MAX)

EX WOOD

FLOOR JOIST

TYP

EX HARDWOOD FLOORING

PROTECT FROM DAMAGE DURING

CONSTRUCTION

STEEL BEAM

SEE PLAN

SEE ARCH DWGS FOR

RATED SHAFT WALL CONSTRUCTION

TYP

SEE ARCH DWGS FOR REQUIRED

FIRESTOP CONSTRUCTION AT EACH SPACE

SHORE & CUT EX WOOD JOIST

FASTEN TO NEW SUPPORT W/

SIMPSON LUS310 METAL CONNECTOR

ADD SHIMS TO SIDE OF JOIST AT

CONNECTOR TO CREATE TIGHT FIT

CONT (2) 2x12

BEAR ON BOT BEAM FLANGE

BEVEL BOT OF INSIDE MEMBER

TO AVOID CONFLICT W/ STEEL

BEAM RADIUS

1/2"ø A307 THRU BOLTS

(W/ WASHERS) @ 12" O.C.

STAGGER TOP & BOT

6" 2 1/

2"

FINISHED SECOND FLOOR

FIELD VERIFY ELEV3"

TEMPORARY SHORING

BY CONTRACTOR

SEE NOTES ON S1.1

FOR REQUIREMENTS

EX WOOD FLOOR JOIST

TYP

EX HARDWOOD FLOORING

PROTECT FROM DAMAGE DURING

CONSTRUCTION

SEE ARCH DWGS FOR

RATED SHAFT WALL CONSTRUCTION

TYP

SEE ARCH DWGS FOR REQUIRED

FIRESTOP CONSTRUCTION AT BEAM FACE

CONT L3x3x1/4

FINISHED SECOND FLOOR

FIELD VERIFY ELEV

S-3.0 SLAB

CONSTRUCTION

SEE DET

L/S3.1

STEEL BEAM

SEE PLAN

TYP

3/16 2-16

NEW 2x SUPPORT

ALONG FLOOR EDGE

SEE PLAN

2x12 BLOCKING SPACED

TO MATCH EX JOIST

BRIDGING LOCATIONS

(8' O.C. MAX)

3"

1'

4"

(4) #5 CONT

ADHESIVE DOWEL 6" INTO

EX MASONRY WALL

(2) DOWELS INTO FAR FACE

(2) DOWELS INTO NEAR FACE

TYPICAL, TOP & BOT

#3 ERECTION BARS

@ 24" O.C.

TOP & BOT

EX MASONRY BEARING WALL

(POCKET WALL FOR CONC BEAM

AND W10 BEAM INSTALLATION)

CONCRETE BEAM 3'-2" LONG

SEE PLAN FOR POSITIONING

5"

F.V.

1' - 0" ±

#3 TIES @ 12" O.C. (3 TIES MIN)

ADHESIVE EMBED EA LEG

8" INTO EX WALL

POSITION TIES TO AVOID CONFLICT

W/ COLUMN ANCHORS

MATCH EX FINISHED SECOND FLOOR

FIELD VERIFY ELEV

BEAM BEYOND NOT SHOWN

FOR CLARITY

STEEL BEAM

SEE PLAN

TYP

S-3.0 SLAB CONSTRUCTION

EX HARDWOOD FLOORING

PROTECT FROM DAMAGE DURING

CONSTRUCTION

CONT WT3x7.5

3/16 2-16

3" E.O.S.

CONT WOOD SHIM

SIZE TO FILL GAP

EX FLOOR JOIST

TYP

TACK WELD BOLT HEADS

TO PREVENT ROTATION

SEE ARCH DWGS FOR REQUIRED

FIRESTOP CONSTRUCTION

EX MASONRY BEARING WALL

(BEYOND)

STEEL COLUMN

SEE PLAN

BOTTOM OF BEAM

ELEV = (+10'-4")

5/16" WEB STIFFNER

EA SIDE OF WEB

STEEL BEAM

SEE PLAN

STEEL CHANNEL REINFORCEMENT

FOR EX WOOD GIRDER

EXTEND 1 1/2" BEYOND CENTERLINE

OF W BEAM MEMBER ABOVE

SEE PLAN, TYP

HANGER PL 5/16x4x1'-3"

CENTERED ABOUT W BEAM

W/ (3) 3/4"ø A325-N BOLTS

TYP AT EA CHANNEL

STIFF PL 5/16x2

ALIGN W/ W BEAM WEB

3/16

TYP

EX WOOD GIRDER NOT SHOWN

CUT GIRDER SHORT OF CHANNEL

SUPPORT CONNECTION

SUPPORT (BOLT) END OF WOOD GIRDER AS IF

IT WAS AT A COLUMN LOCATION

SEE DET G/S4.1

S-3.0 SLAB

CONSTRUCTION

MATCH EX FINISHED THIRD FLOOR

FIELD VERIFY ELEV

CONT HSS5x2x1/4

AT FREE LANDING EDGE

RAILING SYSTEM

BY OTHERS

STEEL BEAM

SEE PLAN

2-12

2-12

PROVIDE PLASTIC BODY FILLER OVER

JOINT ON EXPOSED FACE AND SAND

TO CREATE SMOOTH FACE

G

EX WOOD RAFTER

TO REMAIN CONTINUOUS OVER

STEEL BEAM SUPPORT

EX ROOF SHEATHING

NEW 15/32" APA OVERLAY

SHEATHING

SEE MEP & ARCH DWGS FOR

MECHANICAL UNIT, CURB, &

CHASE CONSTRUCTION

SEE ARCH DWGS FOR

NEW ROOF CONSTRUCTION

CONT 2x6 PLATE

ATTACH TO STEEL BEAM

PER DET G/S3.1

STEEL BEAM

SEE PLAN

(BEAM SLOPES TO

MATCH ROOF SLOPE)

2x12 BLOCKING BELOW UNIT

PERIMETER

PROVIDE HARD WOOD SHIMS

AS REQUIRED TO CREATE EX JOIST

BEARING CONDITION

APPROVED FOR PROGRAM CONCEPT ONLY

APPROVED FOR PROGRAM CONCEPT ONLY

DATE

DATE

ENGINEERING

DIVISION OF

AGENCY

AUTHORIZED AGENT

FOR INTENT ONLY

DIV. OF ENGR.

REVIEWED

ENGR. ACCT. NO.

DRAWING NO.

DATE

A&E FILE NO.

CHECKED BY

SHEET DRAWN BY

RECORD DATE

DATEREVISIONS

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES MANAGEMENT

DIVISION OF ENGINEERING

FRANKFORT, KENTUCKYDK

BSM

470-C5N5-NC11-01

PROFESSIONAL SERVICES CLASSROOM CENTER

RECORD DRAWINGS DATE: 12/18/2015

BROWN & KUBICAN, PSC.

These record drawings have been prepared, in part, on the basis of information compiled and furnished by others. The Engineers has not verified the accuracy and/or completeness of this information and shall not be responsible for any errors or omissions that may be incorporated as a result of erroneous information provided by others.

/3

/2

:3 5:

A

M C

:\U se rs \b m cm ill an

\D es kt op

\L oc al F ile s\

\ 1

_0

G C

T C

A bo de

B K

L

O C

A L

B

S M

S

3.

rv t

S4.2

FRAMING DETAILS

GATEWAY URBAN CAMPUS

438-440 Scott St., Covington, KY 41011

01/06/14

201114.02

SECTION

3/4" = 1'-0"S4.2

A SECTION

3/4" = 1'-0"S4.2

B SECTION

3/4" = 1'-0"S4.2

C SECTION

3/4" = 1'-0"S4.2

D

SECTION

3/4" = 1'-0"S4.2

E SECTION

3/4" = 1'-0"S4.2

F SECTION

3/4" = 1'-0"S4.2

G SECTION

3/4" = 1'-0"S4.2

H

SECTION

3/4" = 1'-0"S4.2

J SECTION

3/4" = 1'-0"S4.2

K

SECTION

3/4" = 1'-0"S4.2

L

SECTION

3/4" = 1'-0"S4.2

N

SECTION

3/4" = 1'-0"S4.2

M

File details come from the government source that posted it. Updated .