23-24 - A5-2 - MISCELLANEOUS DETAILS.pdf
PDF 401 KB Posted
- Solicitation number
- RFP260305
- Issued by
- Hart County, Kentucky
About this file
This architectural drawing document, prepared by the Commonwealth of Kentucky Department for Facilities Management Division of Engineering, presents miscellaneous construction details for the Gateway Urban Campus Classroom Center renovation project located at 438-440 Scott Street in Covington, Kentucky. The drawings, dated September 25, 2014 and approved for program concept on January 5, 2016, provide enlarged detail specifications and plans at scales of 1½" = 1'-0" and 3/8" = 1'-0", detailing interior and exterior wall construction, finishes, and fixtures for the renovation work.
The specifications include construction details for existing plaster surfaced masonry wall repairs, 8-inch concrete masonry unit (CMU) infill work with a 2-hour fire rating, exterior face brick infill in running bond pattern, metal stud framing with gypsum board installation, moisture-resistant gypsum board applications over existing brick shafts, clear polycarbonate corner guards, wood plinth and header details, drapery and hardware specifications (Smith+Noble basis of design with grommet drapery and stainless steel rods), and electric water cooler placement. The document includes 17 detailed sections addressing wall infill dimensions, material specifications, existing conditions, interior finishes for dispensary casework areas, office spaces, and shaft wrap treatments on the second and third floors. Record drawings marked as "as-built" indicate modifications documented through December 18, 2015, with notation that these drawings were prepared based on information compiled by others and the architect/engineer assumes no responsibility for errors or omissions in provided information.
View the file
Other files
Show 40 more
Latest 50 of 80 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
1' - 0"
E Q
E Q
EXISTING
PLASTER
SURFACED
MASONRY
WALL
FEATHER A LAYER
OF SKIM-COAT
PLASTER OVER
EXISTING PLASTER
LEAVE BRICK EXPOSED,
END OF WALL
STEEL MEMBER
REFER TO STRUCT.
DWGS.
WOOD PLINTH
(STAIN TO
MATCH WOOD
FLOOR)
1' - 9"
1' - 2 1/2" +/-
ELECTRIC WATER
COOLER, REFER TO
PLUMBING DRAWINGS
5/8" GWB OVER 7/8"
METAL HAT CHANNEL
FURRING @ 16" O.C.
5/8" GWB OVER 7/8"
METAL HAT CHANNEL
FURRING @ 16" O.C.
CLEAR LEXAN
(POLYCARBONATE)
CORNER GUARDS, 1 1/8" x 1 1/8" x 48" MOUNTED
ABOVE WOOD BASE
(TYPICALL ALL CORNERS
THIS VIEW)
E2
EXISTING
ELEVATOR
E
EXISTING PLASTER
SURFACED 8" CMU
(2 HOUR RATED)
INFILL MASONRY
OPENING WITH 8" CMU
(2 HOUR RATED)
TO MATCH EXISTING
5/8" GWB OVER 3
5/8" METAL STUDS
W A
L L (F
.V
E X
IS
T
IN
G
E X
T E
R
IO
R
FACE BRICK (RUNNING
BONG PATTERN) INFILL
TO MATCH EXISTING
NEW TO EXISTING
GALVANIZED METAL
TIES @ 16" O.C. HORIZ.
AND VERT.
BUILDING WRAP
APPLIED
TO EXISTING
SHEATHING
/8
/2
/8
/8
"WALL INFILL
4" NOM. RUNNING BOND FACE BRICK (MATCH
EXISTING / AIR SPACE / BUILDING WRAP / 1/2"
EXT. GRADE GYPSUM SHEATHING / 6" METAL
STUDS @ 16" O.C. / 5 1/2" FSK-24 BATT INSUL. /
5/8" GYPSUM BOARD
5/8" GWB OVER
7/8" METAL HAT
CHANNEL FURRING
@ 16" O.C.
W A
L L
F .V
E X
IS
T
IN
G
E X
T E
R
IO
R
GALVANIZED
METAL TIES
@ 16" O.C.
HORIZ. AND
VERT.
PATCH AND REPAIR
END OF WALL WITH LIKE
MATERIALS AFTER REMOVEAL
OF EXISTING DOOR AND FRAME,
REPLACE WOOD STUDS AS
REQUIRED FOR END WALL
STABILITY ALIGN NEW AND
EXISTING MATERIAL FOR A
SMOOTH NEAT APPEARANCE
WOOD HEADER TO REMAIN,
PATCH AND REPAIR HEAD
OF OPENING SIMILAR TO
NOTE BELOW, PROVIDE
NEW FINISH TO UNDERSIDE
OF WOOD HEADER, GYPSUM
BOARD OR PLASTER, MATCH
EXISTING
/8
1' - 0"
923 923
/8
1' - 0"
906A906A
906A
906A
906A
W A
L L
F .V
E X
IS
T
IN
G
I N
T E
R
IO
R
5/8" GWB ADHERED TO
EXISTING WALL - FULL
HEIGHT
5/8" GWB ADHERED TO
EXISTING WALL - FULL
HEIGHT
BULK HEAD ABOVE
CLEAR LEXAN
(POLYCARBONATE)
CORNER GUARDS,
1 1/8" x 1 1/8" x 48"
MOUNTED ABOVE
WOOD BASE
(TYPICALL ALL
CORNERS THIS
VIEW)
/4
1' - 2"
8"8"
2x WOOD SHIMS
/4
1' - 3 1/4" +/-
REFER TO
SHEET A7.0
FOR DOOR
JAMB DETAIL
2x WOOD
SHIM1
9 5/8" +/-
1' - 5 1/2"
2' - 0 1/2" 2' - 4"
EXISTING
COLUMN
EXISTING
ELEVATOR
SHAFT
906 906
CLEAR LEXAN
(POLYCARBONATE)
CORNER GUARDS, 1 1/8" x 1 1/8" x 48" MOUNTED
ABOVE WOOD BASE
(TYPICALL ALL CORNERS
THIS VIEW)
5/8" GWB
OVER
7/8" METAL
HAT CHANNEL
FURRING @
16" O.C.
ELECTRIC
WATER
COOLER
REFER TO
PLUMBING
DRAWINGS
1' - 6"
2' - 4"
906 906
5/8" GWB OVER
7/8" METAL HAT
CHANNEL FURRING
@ 16" O.C.
EXISTING
ELEVATOR
SHAFT
5/8" GWB OVER
7/8" METAL HAT
CHANNEL
FURRING
@ 16" O.C.
ELECTRIC
WATER
COOLER,
REFER TO
PLUMBING
DRAWINGS
CLEAR LEXAN
(POLYCARBONATE)
CORNER GUARDS, 1 1/8"
x 1 1/8" x 48" MOUNTED
ABOVE WOOD BASE
(TYPICALL ALL CORNERS
THIS VIEW)
EXISTING COLUMN
906A
906A
5/8" GWB OVER
7/8" METAL HAT CHANNEL
FURRING @ 16" O.C.
/2
8".
CLEAR LEXAN
(POLYCARBONATE)
CORNER GUARDS, 1 1/8" x 1 1/8" x 48" MOUNTED
ABOVE WOOD BASE
(TYPICALL ALL CORNERS
THIS VIEW)
EXISTING COLUMN
906A906A
923A
EXISTING COLUMN
923A
923A
ADHERE 5/8" GWB
TO EXISTING WALL
BOTH SIDES
1ST FLOOR
0' - 0"
7' - 6" A.F.F.
4"
9' - 0" A.F.F.
906.1
CURTAIN AND ROD
BASIS OF DESIGN: SMITH+NOBLE
1. GROMMET DRAPERY: PATTERNED
DRAPERY W/ 200% FULLNESS
TWO PANELS, NO TRIM,
NO COLOR BLOCKING,
PRIVACY LINING, BRUSHED
NICHOL GROMMENTS
2. COSMOPOLITAN GRAND
HARDWARE ROD SET: STAINLESS
STEEL, METAL FLUTE FINIALS,
4 INCH EXTENSION BRACKETS (3).
6" METAL STUD
BOX HEADER
906RA
ADHERE 5/8" MOISTURE
RESISTANT GYPSUM
BOARD DIRECTLY TO
BRICK FACE
DISPENSARY
CASEWORK
5/8" MOISTURE
RESISTANT GYPSUM
BOARD OVER METAL
FURRING, (SIZE FURRING
AS REQUIRED TO CLEAR
EXISTING STEEL TIE
AROUND BRICK SHAFT)
EXISTING
BRICK
SHAFT
ADHERE 5/8"
MOISTURE
RESISTANT
GYPSUM BOARD
DIRECTLY TO
BRICK FACE
5/8" MOISTURE
RESISTANT GYPSUM
BOARD OVER METAL
FURRING, (SIZE FURRING
AS REQUIRED TO CLEAR
EXISTING STEEL TIE
AROUND BRICK SHAFT)
EXISTING
BRICK
SHAFT
906RA
C
COMMONWEALTH
T
R E
R
A
H C
I
N K E
UT
OF
B
3 87
I
R E G
No.
TS E
NT U
C E
YK T
N E R
D
ER
RB
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DATE
DATE
ENGINEERING
DIVISION OF
AGENCY
AUTHORIZED AGENT
FOR INTENT ONLY
DIV. OF ENGR.
REVIEWED
ENGR. ACCT. NO.
DRAWING NO.
DATE
A&E FILE NO.
CHECKED BY
SHEET DRAWN BY
RECORD DATE
DATEREVISIONS
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES MANAGEMENT
DIVISION OF ENGINEERING
FRANKFORT, KENTUCKY
/5
/2
:5 :1
P
M C
U s e rs
\R H in s o n \D o c u m e n ts
\1
G
C T
C
A b o d e B u il d in g R e n o v a ti o n rh in s o n .r v t
A5.2
MISCELLANEOUS DETAILS
470-C5N5-NC11-01
GATEWAY URBAN CAMPUS
09/25/14
201114.02
BB
REH
PROFESSIONAL SERVICES CLASSROOM CENTER
438-440 Scott St., Covington, KY 41011
SCALE: 1 1/2" = 1'-0"A5.2
1 ENLARGED DETAIL
SCALE: 1 1/2" = 1'-0"A5.2
13 ENLARGED DETAIL
SCALE: 1 1/2" = 1'-0"A5.2
3 ENLARGED DETAIL
SCALE: 1 1/2" = 1'-0"A5.2
4 ENLARGED DETAIL
SCALE: 1 1/2" = 1'-0"A5.2
5 ENLARGED DETAIL
SCALE: 1 1/2" = 1'-0"A5.2
7 ENLARGED DETAIL
SCALE: 1 1/2" = 1'-0"A5.2
8 ENLARGED DETAIL
SCALE: 1 1/2" = 1'-0"A5.2
6 ENLARGED DETAIL
SCALE: 1 1/2" = 1'-0"A5.2
14 ENLARGED PLAN
SCALE: 1 1/2" = 1'-0"A5.2
15 ENLARGED PLAN
SCALE: 1 1/2" = 1'-0"A5.2
9 ENLARGED DETAIL
SCALE: 1 1/2" = 1'-0"A5.2
10 ENLARGED DETAIL
SCALE: 1 1/2" = 1'-0"A5.2
11 ENLARGED DETAIL
SCALE: 1 1/2" = 1'-0"A5.2
12 ENLARGED DETAIL
SCALE: 1 1/2" = 1'-0"A5.2
2 ENLARGED DETAIL
AS-BUILT
12-18-15
SCALE: 3/8" = 1'-0"A5.2
SHAFT WRAP @ 2nd Flr - Dispensary
SCALE: 3/8" = 1'-0"A5.2
17 SHAFT WRAP @ 3rd Flr - Office
RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED IN PART, ON THE BASIS OF INFORMATION COMPILED BY OTHERS. THE ARCHITECT/ENGINEER HAS NOT VERIFIED THE ACCURACY OR COMPLETENESS OF THE INFORMATION, AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS THAT MAY BE
INCORPORATED AS A RESULT OF ERRONEOUS INFORMATION PROVIDED BY OTHERS.