42-44 - FP1.1.pdf

PDF 841 KB Posted

Attached to
Surplus Real Property Sale For Economic Development; 438 Scott Boulevard
Solicitation number
RFP260305
Issued by
Hart County, Kentucky

About this file

This is a Fire Protection System design plan prepared by the Commonwealth of Kentucky Finance and Administration Cabinet, Department for Facilities & Support Services, Division of Engineering, in collaboration with Kohrs Lonnemann Heil Engineers, PSC. The document depicts fire protection specifications for the second and third floors of the Gateway Urban Campus located at 438-440 Scott Street, Covington, Kentucky 41011, a facility associated with a Classroom Center. The technical drawings (sheets FP1.1-1 and FP1.1-2) illustrate the layout of new sprinkler systems, including new white recessed pendent sprinkler heads, new brass upright sprinkler heads, and new extended coverage sidewall sprinkler heads, along with associated fire department connections and electric alarm bells. The plan identifies specific areas requiring fire protection coverage, including classroom spaces, massage therapy rooms, dispensaries, offices, corridors, storage areas, and related facilities. The drawings are dated December 18, 2015, and are marked as approved for program concept only, indicating this represents preliminary design documentation rather than final construction specifications.

The document contains no information regarding pricing terms, contract awards, funding sources, set-asides, or renewal options. This appears to be architectural and engineering documentation prepared as part of the planning phase for the Gateway Urban Campus economic development project. The professional services were provided by KLH Engineers with multiple office locations, and the work was conducted under project number 11369.04 with file reference number C5N5-NC11-01. The drawing was prepared at a scale of 1/4 inch equals 1 foot and includes a complete legend identifying all fire protection symbols and system components.

View the file

Other files

File Type Posted
66-67 - CT0.0.pdf PDF
51-49 - HV1.3.pdf PDF
8-13 - A1-1 - FIRST FLOOR DEMOLITION AND NEW WORK PLANS.pdf PDF
34-35 - PD1.1.pdf PDF
30-30 - A8-2 - Basement - FINISHES.pdf PDF
29-29 - A8-1 - ROOM FINISH PLANS (N-I-C- FURNITURE LAYOUT).pdf PDF
12-11 - S4-2 - FRAMING DETAILS.pdf PDF
15-8 - S2-5 - ROOF FRAMING PLAN.pdf PDF
73-19 - A3-0 - BUILDING ELEVATIONS.pdf PDF
49-51 - HV2.0.pdf PDF
72-72 - CT5.2.pdf PDF
67-69 - CT1.2.pdf PDF
62-63 - EP4.0.pdf PDF
3-6 - S2-3 - SECOND FLOOR FRAMING PLAN.pdf PDF
23-24 - A5-2 - MISCELLANEOUS DETAILS.pdf PDF
43-46 - HV1.0.pdf PDF
17-3 - S1-1 - GENERAL NOTES.pdf PDF
13-18 - A2-1 - 2ND 3RD FLR REFLECTED CLG PLANS.pdf PDF
28-31 - A8-3 - 1st FLOOR - FINISHES.pdf PDF
21-23 - A5-1 - MISCELLANEOUS STAIR DETAILS.pdf PDF
70-71 - CT5.1.pdf PDF
36-37 - PL1.1.pdf PDF
31-32 - A8-4 - 2nd Floor - FINISHES.pdf PDF
32-33 - A8-5 - 3rd Floor - FINISHES.pdf PDF
50-52 - HV2.1.pdf PDF
38-40 - PL1.4.pdf PDF
35-34 - PD1.0.pdf PDF
69-70 - CT4.1.pdf PDF
39-39 - PL1.3.pdf PDF
11-12 - A1-0 - BASEMENT DEMOLITION AND NEW WORK PLANS.pdf PDF
68-68 - CT1.0.pdf PDF
25-26 - A6-1 - ENLARGED PLANS AND INTERIOR ELEVATIONS.pdf PDF
63-64 - EL1.0.pdf PDF
19-10 - S4-1 - FRAMING DETAILS.pdf PDF
65-66 - EL2.0.pdf PDF
2-2 - A0-1 - CODE INFO AND WALL TYPES.pdf PDF
9-14 - A1-2 - SECOND FLOOR DEMOLITION AND NEW WORK PLANS.pdf PDF
76-Elevator Inspection 2026-03-25-12-13-48.pdf PDF
58-59 - EP1.3.pdf PDF
46-47 - HV1.1.pdf PDF
57-58 - EP1.2.pdf PDF
61-62 - EP3.0.pdf PDF
80-438 Scott Full Inspection Report (PDF).pdf PDF
7-5 - S2-2 - FIRST FLOOR FRAMING PLAN.pdf PDF
53-54 - HV3.1.pdf PDF
4-9 - S3-1 - TYPICAL DETAILS.pdf PDF
1-4 - S2-1 - FOUNDATION PLAN.pdf PDF
24-25 - A6-0 - ENLARGED PLANS AND INTERIOR ELEVATIONS.pdf PDF
48-50 - HV1.4.pdf PDF
20-21 - A4-1 - BUILDING SECTIONS.pdf PDF
Show 40 more

Latest 50 of 80 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D W

D W

F S

T S

B C D EA G

F

CLASSROOM

FACIAL / COUPLE

MASSAGE

STAIR

D2

DISPENSARY

MEN

WOMEN

CUST.

206A

EXISTING STAIR

C2

OFFICE 2

OFFICE 1

CORRIDOR

200A

CLOSET

EXISTING STAIR

B2

N

N

A.F.F.10' - 0"

A.F.F.10' - 0"

A.F.F.10' - 0"

A.F.F.10' - 0"

A.F.F.9' - 6"

A.F.F.9' - 0"

A.F.F.10' - 0"

N

N

N

N

N

N N

N

N

N

N

NN

N N

N

NN

N N

N N

N N

N N

N

N

N

N

N

N

N N

N

NN

B C D EA G

F

CORRIDOR

LH

SPRINKLERS AT TOP OF

ELEVATOR SHAFT

CLIENT MASSAGE

301D

CLIENT MASSAGE

301E

CLIENT MASSAGE

301C

CLIENT MASSAGE

301A

OFFICE

302C

STORAGE

MEN

STAIR

D3

EXISTING STAIR

C3

MASSAGE CLINICAL

LAB

WOMEN

LOBBY

CLIENT MASSAGE

301B

LINENS

301F

CORRIDOR

300A

CLOSET

HVAC

302A

ROOF ACCESS

302B

N

N N N N N N

N N N N N N

N

N

N N N N

NN

N

N

N

N

N

N

N N

N

N N

N

N N

N

N

N

N

N N

N

N N

N NN

N

N

DESCRIPTIONSYMBOL

SPRINKLER LEGEND

NEW SIDEWALL SPRINKLER HEAD

N

FLOW SWITCH

TAMPER SWITCH

N

NEW WHITE RECESSED PENDENT SPRINKLER HEAD

N

NEW BRASS UPRIGHT SPRINKLER HEAD

FIRE DEPARTMENT CONNECTION

ELECTRIC ALARM BELL

FDC

EB

NEW EXTENDED COVERAGE SIDEWALL SPRINKLER HEAD

N

APPROVED FOR PROGRAM CONCEPT ONLY

APPROVED FOR PROGRAM CONCEPT ONLY

DATE

DATE

ENGINEERING

DIVISION OF

AGENCY

AUTHORIZED AGENT

FOR INTENT ONLY

DIV. OF ENGR.

REVIEWED

ENGR. ACCT NO.

DRAWING NO.

DATE

A&E FILE NO.

CHECKED BY

SHEET DRAWN BY

RECORD DATE

DATEREVISIONS

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES & SUPPORT SERVICES

DIVISION OF ENGINEERING

FRANKFORT, KENTUCKY

WWW.KLHENGRS.COM

ENGINEERS, PSC

MECHANICAL/ELECTRICAL ENGINEERS

KOHRS LONNEMANN HEIL

LEXINGTON, KENTUCKY

COLUMBUS, OHIO

DAYTON, OHIO

NEW YORK, NEW YORK

1538 ALEXANDRIA PIKE, SUITE

11 FT. THOMAS, KENTUCKY

41075 800-354-9783

859-442-8050

859-442-8058 FAX

KLH PRO. NO.

11369.04

PROFESSIONAL SERVICES CLASSROOM CENTER

/1

/2

:3 :0

A

M

FP1.1

FIRE PROTECTION - 2ND AND 3RD

FLOORS

C5N5-NC11-01

GATEWAY URBAN CAMPUS

438-440 Scott St., Covington, KY 41011

12/18/15

201114.02

JCJ

KPO

SCALE: 1/4" = 1'-0"FP1.1

1 FIRE PROTECTION - NEW - 2ND FLOOR

SCALE: 1/4" = 1'-0"FP1.1

2 FIRE PROTECTION - NEW - 3RD FLOOR