67-69 - CT1.2.pdf
PDF 395 KB Posted
- Solicitation number
- RFP260305
- Issued by
- Hart County, Kentucky
About this file
This is an architectural floor plan and communication technology infrastructure drawing prepared by the Commonwealth of Kentucky Finance and Administration Cabinet, Department for Facilities & Support Services, Division of Engineering, in conjunction with Kohrs Lonnemann Heil Engineers for the Gateway Urban Campus located at 438-440 Scott Street in Covington, Kentucky. The drawing specifications detail the installation of new communication technology systems on the second and third floors of the facility, including classroom and massage therapy spaces. The project encompasses the rough-in installation of four-inch vertical conduit sleeves for horizontal and backbone cabling pathways with a maximum fill capacity of forty percent, audio-visual equipment mounting and connections, data outlet installations, and interactive projector integration. Specific technical notes indicate device mounting requirements at ninety inches above finished floor, coordination points with owner-provided equipment, and the provision of audio-visual input and output plates with designated box specifications and conduit requirements. The drawing was approved for program concept on December 18, 2015, with the professional services designation dated January 12, 2016.
The project is associated with a Surplus Real Property Sale for Economic Development involving 438 Scott Boulevard in Covington, Kentucky. The communication technology infrastructure improvements are designed to support classroom and clinical laboratory operations within the facility. The drawings bear multiple approval and review stamps from the Engineering Division, indicating standard review and authorization procedures for state facility projects. The document references coordination requirements with all trades and the need to provide additional conduit quantities beyond minimum quantities shown, suggesting a scalable infrastructure approach designed to accommodate future expansion and equipment modifications.
View the file
Other files
Show 40 more
Latest 50 of 80 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C
C
C
C
S
LILO
S SS
SS
S S S S
C
C
C
MC
S
S S S S
S S S
CLASSROOM
W
FACIAL / COUPLE
MASSAGE
STAIR
D2
DISPENSARY
MEN
WOMEN
CUST.
206A
EXISTING STAIR
C2
OFFICE 2
OFFICE 1
CORRIDOR
CORRIDOR
200A
CLOSET
EXISTING STAIR
B2
WAP
WAP
BGM
2D
5557 56
B C D EA G
F
CLIENT MASSAGE
301D
CLIENT MASSAGE
301E
CLIENT MASSAGE
301C
CLIENT MASSAGE
301B
CLIENT MASSAGE
301A
OFFICE
302C
STORAGE
STAIR
D3
MASSAGE CLINICAL
LAB
WOMEN
CORRIDOR
LOBBY
MEN
EXISTING STAIR
C3
LINENS
301F
CORRIDOR
300A
CLOSET
CL.
HVAC
302A ROOF ACCESS
302B
WAP WAP
BGMBGMBGMBGM
BGM
BGM
BGM
BGM BGM
BGM
BGMBGM
BGMBGM
BGMBGM
BGM
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DATE
DATE
ENGINEERING
DIVISION OF
AGENCY
AUTHORIZED AGENT
FOR INTENT ONLY
DIV. OF ENGR.
REVIEWED
ENGR. ACCT NO.
DRAWING NO.
DATE
A&E FILE NO.
CHECKED BY
SHEET DRAWN BY
RECORD DATE
DATEREVISIONS
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING
FRANKFORT, KENTUCKY
WWW.KLHENGRS.COM
ENGINEERS, PSC
MECHANICAL/ELECTRICAL ENGINEERS
KOHRS LONNEMANN HEIL
LEXINGTON, KENTUCKY
COLUMBUS, OHIO
DAYTON, OHIO
NEW YORK, NEW YORK
1538 ALEXANDRIA PIKE, SUITE
11 FT. THOMAS, KENTUCKY
41075 800-354-9783 859-442-8050
859-442-8058 FAX
KLH PRO. NO.
11369.04
PROFESSIONAL SERVICES CLASSROOM CENTER
/1
/2
:4 :5
A
M
CT1.2
COMMUNICATION TECHNOLOGY -
NEW - 2ND AND 3RD FLOORS
470-C5N5-NC11-01
GATEWAY URBAN CAMPUS
438-440 Scott St., Covington, KY 41011
12/18/15
201114.02
Author
Checker
KEYED NOTES
54 4-INCH VERTICAL CONDUIT SLEEVES (FROM FLOOR BELOW TO
ABOVE ACCESSIBLE CEILING) FOR HORIZONTAL AND BACKBONE
CABLING PATHWAYS. MINIMUM QUANTITIES SHOWN. PROVIDE
ADDITIONAL QUANTITIES AS REQUIRED FOR CABLE SEPARATION
AND 40-PERCENT MAXIMUM FILL CAPACITY. COORDINATE WITH ALL
TRADES.
55 MOUNT DEVICE 90" AFF. COORDINATE WITH OWNER PROVIDED
INTERACTIVE PROJECTOR AND POWER RECEPTACLE.
56 ROUGH-IN FOR OWNER PROVIDED AUDIO VISUAL LOCAL INPUT
PLATE. PROVIDE 3-1/2" DEEP, 4" SQUARE BOX WITH 2-GANG
PLASTER RING AND (2) 1-1/4" CONDUITS TAAC AT 18" AFF.
COORDINATE WITH DATA OUTLET AND POWER RECEPTACLE.
57 ROUGH-IN FOR OWNER PROVIDED AUDIO VISUAL LOCAL OUTPUT
PLATE. PROVIDE 3-1/2" DEEP, 4" SQUARE BOX WITH 2-GANG
PLASTER RING AND (2) 1-1/4" CONDUITS TAAC AT 90" AFF.
COORDINATE WITH OWNER PROVIDED INTERACTIVE PROJECTOR,
DATA OUTLET AND POWER RECEPTACLE.
SCALE: 1/4" = 1'-0"CT1.2
1 COMMUNICATION TECHNOLOGY - NEW - 2ND FLOOR
SCALE: 1/4" = 1'-0"CT1.2
2 COMMUNICATION TECHNOLOGY - NEW - 3RD FLOOR
NORTH
PLAN
5 PR-22 - Third Floor
Electric
10/14/2014
File details come from the government source that posted it. Updated .