11-12 - A1-0 - BASEMENT DEMOLITION AND NEW WORK PLANS.pdf
PDF 200 KB Posted
- Solicitation number
- RFP260305
- Issued by
- Hart County, Kentucky
About this file
This document is a Basement Demolition and New Work Plans sheet prepared by the Commonwealth of Kentucky Finance and Administration Cabinet, Department for Facilities Management, Division of Engineering for the Gateway Urban Campus Professional Services Classroom Center located at 438-440 Scott Street, Covington, Kentucky. The project scope encompasses comprehensive basement-level renovation work including selective demolition of existing structural elements, wall modifications, and new construction. Demolition activities include removal of an existing column and beam, portions of existing stone walls with steel lintels, wood base trim, existing VCT flooring, and carpet from stair treads and risers. New work comprises installation of twelve-inch CMU wall infill in multiple locations, spray-applied waterproofing membranes, moisture and mold-resistant gypsum board, epoxy floor finishes with slip-resistant surfaces, new double-tiered metal lockers, casework with solid surface countertops, tack surface wall coverings, and filling of an existing coal shoot access door at the sidewalk with concrete. The plan was dated September 25, 2014, with record drawings updated as of December 18, 2015, and is drawn at a scale of one-quarter inch equals one foot.
The demolition and new work general notes establish that the contractor is responsible for all means and methods, utility coordination and disconnection, obtaining all required permits and inspections, and ensuring compliance with applicable federal, state, and local codes and regulations. The contractor must maintain access to adjacent property, remove all demolished material from the site in accordance with municipal, state, and federal regulations, and complete all infill or replacement work to match existing conditions in materials, construction, and finish. All work performed in excess of the plans or any damage to existing construction-to-remain shall be repaired at the contractor's expense, with a one-year warranty on workmanship, materials, and performance from date of acceptance. The contractor must notify the architect and structural engineer of any pre-existing or concurrent compromised conditions observed in the existing structure-to-remain, including corrosion, warping, or deflection.
View the file
Other files
Show 40 more
Latest 50 of 80 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXISTING
ELEVATOR
EXISTING
ELEVATOR
MACHINE
ROOM
EXISTING
MECHANICAL ROOM
EXISTING
STORAGE
EXISTING STAIRS EXISTING COLUMNS AND BEAM ABOVE - TO REMAIN
EXISTING COLUMNS AND BEAM ABOVE - TO REMAIN
EXISTING FLOOR
DRAIN TO REMAIN
REMOVE EXISTING
COLUMN AND
BEAM ABOVE IN
THEIR ENTIRETY
REMOVE EXISTING
WALL IN ITS ENTIRITY
REMOVE CARPET FROM
STAIR TREADS & RISERS
EXISTING
HVAC
REMOVE EXISTING VCT
AND PREP EXISTING
CONCRETE FLOOR TO
RECEIVE NEW FINISH
PREP EXISTING FLOOR
JOISTS ABOVE AND ALL
REMAINING PIPES/HVAC
EQUIPMENT TO REMAIN TO
RECEIVE NEW FINISH
DEMOLITION LIMITS
D E
M O
L
IT
IO
N
L
IM
IT
S
D E
M O
L
IT
IO
N
L
IM
IT
S
PREP EXISTING STONE
WALL SURFACE TO
RECEIVE NEW PAINT FINISH
PREP EXISTING
STONE WALL
SURFACE TO
RECEIVE NEW
PAINT FINISH
REMOVE PORTION OF
EXISTING WOOD BASE
APPROX.
10' - 7 7/8"
4' - 0 1/4" +/-
REMOVE PORTION OF EXISTING STONE WALL
COMPLETELY, REMOVE EXISTING STEEL
LINTEL, SHORE OPENING IN PREPARATION
FOR NEW WORK, SAW CUT EDGES FOR A
SMOOTH NEAT APPEARANCE
NO WORK THIS AREA
REMOVE PORTION OF
EXISTING STONE WALL
COMPLETELY, SHORE
OPENING IN PREPARATION
FOR NEW WORK, SAW CUT
EDGES FOR A SMOOTH
NEAT APPEARANCE
PREP EXISTING
STONE WALL
SURFACE TO
RECEIVE NEW
PAINT FINISH
26' - 7" +/- 14' - 0" +/-
/2
9' - 7" +/-
EXISTING
SLAB/FOUNDATION
WALL ABOVE
EXISTING
SLAB/FOUNDATION
WALL ABOVE
STUDENT LOUNGE
EXISTING STORAGE
EXISTING
MECHANICAL
ROOM
A4.0
A4.0
A4.1
A4.1
B C D EA G
E Q
E Q
1' - 8"
9' - 0" 14' - 0"
5' - 0" M.O. 9' - 0"
3' - 4" 8"
6' - 6"
6"
EXISTING
ELEVATOR
MACHINE ROOM
A4.0
A4.0
EXISTING STAIR
A
EXISTING
ELEVATOR
E
A4.1
A4.1
923A
906A906A
906A
906A
906A
906A
3 2
5 5 5
S0
S0
A6.0
A6.0
E2
E2
F
1' - 0"
12" CMU
WALL INFILL
12" CMU
WALL INFILL
12" CMU
WALL INFILL
12" CMU WALL INFILL, REFER TO
STRUCTURAL DRAWINGS
SEE STRUCTURAL DETAIL FOR
WALL ALIGNMENT WITH EXISTING
STRUCTURE
SPRAY APPLIED WATERPROOFING MEMBRANE:
OVERSPRAY AT EXISTING WALLS, ADJACENT
TO CMU, TYPICAL
SPRAY APPLIED WATERPROOFING
MEMBRANE:
EXTEND TO MID-RISE PORTION OF
CMU WALL THIS AREA, FULL HEIGHT
EACH END OF NEW WALL
SPRAY APPLIED WATERPROOFING
MEMBRANE:
EXTEND FULL HEIGHT OF NEW WALL
AND OVERSPRAY @ EACH ENDS
MOISTURE & MOLD
RESISTANT
GYPSUM BOARD
MOISTURE & MOLD
RESISTANT
GYPSUM BOARD
PROVIDE INFILL AT EXISTING COAL SHOOT.
REMOVE EXISTING STEEL ACCESS DOOR
AT SIDEWALK, FILL HOLE WITH LEANCRETE
CONCRETE AND TOP WITH 4" THICK SIDEWALK
GRADE CONFRETE AND EXPANSION JOINT
MATERIAL.
DEMOLITION PLAN LEGEND
OBJECT TO BE DEMOLISHED
EXISTING OBJECT TO REMAIN
EXISTING WALLS TO REMAIN
DEMOLITION GENERAL NOTES
A. ALL DEMOLITION WORK SHALL BE EXECUTED IN COMPLIANCE WITH ALL
APPLICABLE FEDERAL, STATE, AND LOCAL CODES, LAWS, AND
REGULATIONS.
B. CONTRACTOR IS TO COORDINATE ALL UTILITY DISCONNECTION WORK
PRIOR TO START OF DEMOLITION WORK.
C. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND PAYING
FOR ALL PERMITS, INSPECTIONS, TESTS, ETC. THAT MAY BE REQUIRED
FOR ALL DEMOLITION WORK.
D. CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL MEANS AND METHODS
OF ALL DEMOLITION WORK AND FOR PROVIDING ALL NECESSARY
TEMPORARY PROTECTION AS NECESSARY FOR THE SAFETY AND
STABILITY OF ALL EXISTING ELEMENTS AND STRUCTURE TO REMAIN.
E. CONTRACTOR SHALL MAINTAIN EXISTING ACCESS TO ADJACENT
PROPERTY DURING DEMOLITION/CONSTRUCTION.
F. CONTRACTOR SHALL VISIT THE SITE AND FACILITY TO VERIFY ALL
EXISTING CONDITIONS AND VERIFY THE SCOPE OF WORK INDICATED
BY ALL CONTRACT DOCUMENTS; FAILURE TO REASONABLY
DETERMINE AND/OR ANTICIPATE THE IMPACT OF THE SCOPE OF
WORK ON EXISTING CONDITIONS SHALL NOT BE JUSTIFICATION
FOR ADDITIONAL COMPENSATION; ANY DISCREPANCIES DISCOVERED
IN THE CONTRACT DOCUMENTS SHALL BE IMMEDIATELY REPORTED
TO ARCHITECT PRIOR TO SUBMISSION OF BID.
G. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL EXISTING
FIXTURES AND EQUIPMENT THAT REMAINS WITHIN BUILDING OR ON
SITE, UNLESS NOTED OTHERWISE.
H. UNLESS NOTED OTHERWISE, ALL DEMOLISHED MATERIAL AND
EQUIPMENT IS TO BECOME THE PROPERTY OF THE CONTRACTOR
AND SHALL BE REMOVED FROM THE SITE IN A MANNER THAT IS SAFE
AND COMPLIANT WITH MUNICIPAL, STATE, AND FEDERAL
REGULATIONS; NO ON-SITE SALE OF MATERIALS IS ALLOWED.
I. CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION AGAINST
WEATHER INFILTRATION AND CONSTRUCTION ACTIVITIES FOR ALL
EXISTING CONSTRUCTION TO REMAIN DURING THE DEMOLITION AND
CONSTRUCTION PROCESS TO PREVENT DAMAGE TO EXISTING
FINISHES OR MATERIALS THAT ARE TO REMAIN.
J. ALL DEMOLITION WORK PERFORMED IN EXCESS OF THAT INDICATED
ON PLANS AND ANY DAMAGE TO EXISTING-TO-REMAIN
CONSTRUCTION SHALL BE PATCHED, REPAIRED, AND/OR REPLACED
TO "LIKE-NEW" CONDITION AT CONTRACTOR'S EXPENSE.
K. ALL INFILL OR REPLACEMENT WORK SHALL MATCH EXISTING
CONDITIONS IN MATERIALS, CONSTRUCTION, AND FINISH, UNLESS
SPECIFICALLY NOTED ELSEWHERE IN THE DEMOLITION
DOCUMENTS; MATERIAL NOT SPECIFICALLY SPECIFIED SHALL BE
EQUAL IN QUALITY TO EXISTING MATERIAL OR LIKE KIND;
GUARANTEE ALL WORKMANSHIP, MATERIAL, AND PERFORMANCE FOR
A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE (UNLESS
OTHERWISE NOTED).
L. CONTRACTOR IS RESPONSIBLE FOR DEMOLITION AND REMOVAL OF ALL
COMPONENTS IN SUCH A WAY AS TO NOT DAMAGE OR OTHERWISE
COMPROMISE EXISTING STRUCTURE-TO-REMAIN.
M. NOTIFY ARCHITECT AND STRUCTURAL ENGINEER REGARDING
PRE-EXISTING OR CONCURRENT COMPROMISED CONDITIONS
(INCLUDING EXCESSIVE CORROSION, WARPING, OR DEFLECTION)
THAT IS OBSERVED IN EXISTING STRUCTURE-TO-REMAIN (INCLUDING,
BUT NOT LIMITED TO, STEEL DECK, JOISTS, BEAMS, AND COLUMNS).
NEW WORK GENERAL NOTES
A. ALL WALLS ARE FULL HEIGHT, U.N.O. (REFER TO WALL TAG WITH
HEIGHT INDICATED OR TOP OF WALL DELINEATION.
B. PROVIDE GYPSUM BOARD CONTROL JOINTS EVERY 30 FEET MINIMUM.
C. REFER TO ENLARGED PLANS FOR ADDITIONAL DETAILING OR
DIMENSIONING NOT SHOWN THIS SHEET. REFER TO SHEET A0.1 FOR
WALL TYPES.
D. REFER TO A6 SERIES SHEETS FOR ENLARGED PLANS AND
CORRESPONDING INTERIOR ELEVATIONS.
E. REFER TO A7 SERIES SHEETS FOR DOOR AND WINDOW SCHEDULES,
ELEVATIONS AND DETAILS.
F. REFER TO A8 SERIES SHEETS FOR FLOOR FINISH PLANS, SCHEDULES
AND DETAILS.
G. ALL DIMENSIONS ARE FROM EXISTING FACE OF WALL TO FACE OF
STUD, OR FROM OUTSIDE FACE OF STUD TO OUTSIDE FACE OF STUD,
U.N.O.
NEW WORK CODED NOTES
1. PROVIDE EPOXY FLOOR FINISH, WITH SLIP RESISTANT SURFACE..
2. TUCKPOINT MISSING SECTIONS OF EXISTING STONE WALL.
3. EXISTING MASONRY WALL TO REMAIN EXPOSED, PAINT.
4. NEW DOUBLE TIERED METAL LOCKERS (12X18), REFER TO
SPECIFICATIONS.
5. VENDING MACHINES, N.I.C.
6. CASEWORK: SOLID SURFACE COUNTERTOP/ SIDE/BACKSPLASH,
PLASTIC LAMINATE BASE CABINET. REFER TO INTERIOR ELEVATIONS
FOR FINISHES, PROVIDE POWER FOR MICROWAVE.
7. TACK SURFACE COVERING WALL TO WALL, BASEBOARD TO CEILING.
BASIS OF DESIGN: TAC-WALL by WALLTALKERS.
8. NEW CONCRETE BEAM ABOVE, REFER TO STRUCTURAL DRAWINGS.
9. EXISTING HVAC EQUIPMENT, REFER TO MEP DRAWINGS.
10. NOT USED.
11. APPLY MORTAR TO FACE OF SAWCUT JAMBS, INFILL ALL VOIDS, FINISH
TO BE ROUGH, MATCH EXISTING INTERIOR ROOM WALL SURFACE,
PAINT.
12. WALL MOUNTED FIRE EXTINGUISHER.
X
C
COMMONWEALTH
T
R E
R
A
H C
I
N K
E
UT
OF
B
3 87
I
R E
G
No.
TS E
NT U
C E
YK T
N E R
D
ER
RB
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DATE
DATE
ENGINEERING
DIVISION OF
AGENCY
AUTHORIZED AGENT
FOR INTENT ONLY
DIV. OF ENGR.
REVIEWED
ENGR. ACCT. NO.
DRAWING NO.
DATE
A&E FILE NO.
CHECKED BY
SHEET DRAWN BY
RECORD DATE
DATEREVISIONS
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES MANAGEMENT
DIVISION OF ENGINEERING
FRANKFORT, KENTUCKY
/5
/2
:5 :5
P
M C
U s e rs
\R H in s o n \D o c u m e n ts
\1
G
C T
C
A b o d e B u il d in g R e n o v a ti o n rh in s o n .r v t
A1.0
BASEMENT DEMOLITION AND NEW
WORK PLANS
470-C5N5-NC11-01
GATEWAY URBAN CAMPUS
09/25/14
201114.02
BB
REH
PROFESSIONAL SERVICES CLASSROOM CENTER
438-440 Scott St., Covington, KY 41011
SCALE: 1/4" = 1'-0"A1.0
1 BASEMENT - DEMOLITION PLAN
SCALE: 1/4" = 1'-0"A1.0
2 BASEMENT - NEW WORK
NORTH
PLAN
NORTH
PLAN
AS-BUILT
12-18-15
RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED IN PART, ON THE BASIS OF INFORMATION COMPILED BY OTHERS. THE ARCHITECT/ENGINEER HAS NOT VERIFIED THE ACCURACY OR COMPLETENESS OF THE INFORMATION, AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS THAT MAY BE
INCORPORATED AS A RESULT OF ERRONEOUS INFORMATION PROVIDED BY OTHERS.
File details come from the government source that posted it. Updated .