This document is a culvert inspection report for Structure No. 5570-314P located on the Natchez Trace Parkway in Mississippi. The triple-barrel concrete culvert is in fair condition overall, with the main issues being heavy accumulation of silt and debris in the channel at the ends of the barrels, moderate to severe cracking of the top of the wingwalls and headwalls, minor to moderate cracking of the asphalt pavement, minor deterioration of the barrel concrete, and moderate erosion of the upstream channel banks.
The report provides recommendations and estimated costs for maintenance, rehabilitation, and reconstruction work, including removing silt and debris from the channel, cleaning and sealing cracks in the pavement and concrete structures, and monitoring the condition of the channel banks. The total estimated cost for the recommended work is $35,000. The culvert has a satisfactory load rating and is open to normal traffic.
View the file
Other files
Show 40 more
Latest 50 of 53 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CULVERT INSPECTION REPORT
CULVERT AT MP 128.30
NATCHEZ TRACE PARKWAY OVER STREAM
NATCHEZ TRACE PARKWAY
LN
STRUCTURE NO. 5570-314P
INSPECTION TYPE: ROUTINE
INSPECTION DATE: 3/15/2022
ED
Report prepared by:
Federal Highway Administration Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 https://bridge.flhd.fhwa.dot.gov
MILE POINT: 128.30
KILOMETER POINT: 206.43
https://bridge.flhd.fhwa.dot.gov
STRUCTURE SUMMARY STRUCTURE NO. 5570-314P
CULVERT AT MP 128.30 INSPECTION DATE: 03/15/2022
CULVERT IDENTIFICATION AND DESCRIPTION
MAIN SPAN MATERIAL: ..... 1 - CONCRETE NO. OF BARRELS:
FOUNDATION: .................... 2 - SPREAD FTG ON BEARING BARREL LENGTH: ............. 55 FT (16.76 M)
STRUCT. TOTAL LENGTH: 26.0 FT (7.9 M) SKEW ANGLE: ................... 0 °
MAX. SPAN LENGTH: ........ 9.0 FT (2.7 M) YEAR BUILT:
PROJ./PLAN REF. NO: ....... 3N1 YEAR RECONSTRUCTED:
NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD
STRUCTURE HISTORY:
LOCATION
NATCHEZ TRACE PARKWAY MILE POINT: .. 128.30 (KM PT 206.43)
STATE: ................................ 284 - MISSISSIPPI LOCATION: .... 6.8 MILES TO MS ROUTE 16
FACILITY CARRIED: .......... NATCHEZ TRACE PARKWAY
FEATURE INTERSECTED: STREAM
INSPECTION TEAM: N. Brown, D. Martin
CONDITION ASSESSMENT:
David Martin
REPORT REVIEW:
Marcus Miller
REPORT APPROVAL: Date: 07/13/2022
Jorgomai Ceesay
STRUCTURE EVALUATION SUMMARY
This triple barrel concrete culvert is in fair condition overall. The main problem is heavy accumulation of silt and debris in the channel at the ends of the barrels. Up to 50% of south and center barrels are currently blocked at the upstream end.
Other problems include moderate to severe cracking of the top of the wingwalls and headwalls; minor to moderate cracking of asphalt pavement; minor deterioration of the barrel concrete, with rebar exposed in some locations; missing headwall markers; and moderate erosion of the upstream channel banks. The erosion of the channel banks will continue to be monitored during future inspections.
Corrective action should be taken as outlined in this report to prevent the possible development of more serious or costly problems in the future.
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5570-314P
CULVERT AT MP 128.30 INSPECTION DATE : 03/15/2022
PRIORITY OF IMPROVEMENT226
A (Critical) - Structure is closed, in immediate damage of collapse, or presents a critical safety danger.
B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain open at reduced loads or with frequent inspections.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventive maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
C
Item No.
Maintenance Recommendations
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT UNIT
COST
PRELIM.
COST
ESTIMATE
222.7
INSTALL ADDITIONAL HEADWALL MARKERS AS
NECESSARY. 1 LS 1000 1000
PRELIM. MAINTENANCE TOTAL : 1000
Item No.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS)
QTY. UNIT
UNIT
COST
PRELIM. COST ESTIMATES
REHAB RECONSTR
61.4,62.5 REMOVE SILT AND DEBRIS FROM CHANNEL AT
ENDS OF BARRELS. 1 LS 10000 10000
62.10, 222.4
CLEAN AND SEAL CRACKING OF PAVEMENT.
1 LS 5000 5000
62.3,62.4 CLEAN AND SEAL CRACKING OF WINGWALLS
AND HEADWALLS WITH APPROVED SEALANT. 1 LS 5000 5000
CONTRACT COSTS FOR MOBILIZATION,
TRAFFIC CONTROL, DESIGN, AND
CONSTRUCTION ENGINEERING.
1 LS 14000 14000
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL : 34000
COST ESTIMATE SUMMARY
PRELIM. MAINTENANCE TOTAL :
PRELIM. REHABILITATION TOTAL :
PRELIM. RECONSTRUCTION TOTAL : .. 0
TOTAL ITEMIZED COSTS:
PRELIMINARY ESTIMATE TOTAL * :
(*Includes typical contract costs for mobilization, traffic control and design/construction engineering: but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for planning purposes only; they should not be used as a complete or final engineers estimate.)
Remarks : Cost estimates assume that recommended actions will be combined with similar work being performed on other structures.
Condition of channel banks will continue to be monitored.
FIELD INSPECTION REPORT STRUCTURE NO. 5570-314P
CULVERT AT MP 128 30 INSPECTION DATE: 03/14/2022
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
N NOT APPLICABLE 3 SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible. Fatigue cracks in steel or 9 EXCELLENT CONDITION shear cracks in concrete may be present.
8 VERY GOOD CONDITION - no problems noted. 2 CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed
7 GOOD CONDITION - some minor problems. substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
6 SATISFACTORY CONDITION - structural elements show some minor deterioration.
1 “IMM NENT” FAILURE CONDITION - major deterioration or section loss present in critical
5 FA R CONDITION - all primary structural elements are sound but may have minor structural components or obvious vertical or horizontal movement affecting structure stability.
section loss, cracking, spalling, or scour. Structure is closed to
4 POOR CONDITION - advanced section loss, deterioration, spalling, or scour. 0 FA LED CONDITION - out of service; beyond corrective action.
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
61. CHANNEL 5 222. APPROACHES 6
1. ALIGNMENT: G 1. APPROACH SLABS: N
2. EROSION AND/OR SCOUR: F 2. RELIEF JOINTS: N
3. CHANNEL PROTECTION: N 3. APPROACH GUARDRAIL: N
4. WATERWAY OBSTRUCTIONS: P 4. SURFACING: F
5. OTHER: N 5. EROSION: G
6. ADEQUACY OF OPENING: 1- SUFF 6. SETTLEMENT: G
7. NORMAL VELOCITY: 3 - LOW 7. SIGNS: F
8. AVERAGE CLEAR OPENING: 5 FT 8. ALIGNMENT: G
9. STREAM BED COMPOSITION: 9. OTHER: N
SAND, SILT 223. RETAINING WALL N
62. CULVERT 6
1. BARREL(S): F
2. FOOTINGS: N
3. HEADWALLS: F
4. WINGWALLS: F
5. DEBRIS AND/OR SLIT: F
6. EROSION AND/OR SCOUR: F
7. SETTLEMENT AND/OR DEFLECTION: G
8. ADEQUACY OF COVER: G
9. PARAPETS AND/OR RAILINGS: N
10. ROADWAY SURFACE: F
11. RIDEABILITY: G
12. OTHER: N
1. WALL:
2. WEEP HOLES:
3. FOUNDATION:
4. EROSION AND/OR SCOUR:
5. SETTLEMENT OR DEFLECTION:
6. OTHER
36. TRAFFIC AND SAFETY FEATURES
A. BRIDGE RAILINGS: N
B. TRANSITIONS: N
C. APPROACH GUARDRAILS: N
D. APPROACH GUARDRAIL ENDS: N
TRAFFIC SAFETY RATING CODES
0 - Does not meet standards or a safety features is required and none is provided.
1 - Meets currently acceptable standards.
N - Not applicable or a safety features is not required.
(cont'd)FIELD INSPECTION REPORT - CULVERT STRUCTURE NO. 5570-314P
ITEM REFERENCE AND REMARKS
61.2 MODERATE EROSION OF UPSTREAM CHANNEL BANKS AND ALONG SOUTHWEST AND NORTHWEST WINGWALLS.
SEE BRIDGE FILE FOR SCOUR EVALUATION.
61.4
62.5
HEAVY ACCUMULATION OF DEBRIS IN CHANNEL AT UPSTREAM END OF SOUTH BARREL AND CENTER BARREL. HEAVY ACCUMULATION OF SILT AND DEBRIS IN CHANNEL AT DOWNSTREAM END OF CENTER AND NORTH BARRELS. MINOR ACCUMULATION SILT IN NORTH BARREL, UP TO 1-1/2'H (COULD NOT VERIFY DUE TO HIGH WATER).
62.1 COULD NOT PASS THROUGH CULVERT DUE TO HIGH WATER. MINOR SCALING OF BARREL WALLS AT WATERLINE (COULD NOT VERIFY DUE TO HIGH WATER). MINOR CRACKING OF TOP SLAB UNDERSIDE WITH EFFLORESCENCE AND WATER LEAKAGE AT ENDS. MINOR CRACKING AND DELAMINATION OF SOUTH WALL OF SOUTH BARREL AT EAST END. MINOR SPALLING OF TOP SLAB UNDERSIDE WITH EXPOSED REBAR AT EAST END OF CENTER BARREL. MINOR HONEYCOMBING OF TOP SLAB UNDERSIDE WITH
EXPOSED REBAR AT WEST END OF NORTH BARREL.
62.3
62.4
MODERATE TO SEVERE LONGITUDINAL CRACKING OF TOP OF WINGWALLS AND HEADWALLS; SOME AREAS ARE PATCHED.
62.6
62.4
MINOR EROSION AT WINGWALL ENDS. MINOR SCOUR AT DOWNSTREAM END OF SOUTH BARREL, WITH FLOOR SLAB EXPOSURE, UP TO 4"H.
62.10
222.4
MINOR TO MODERATE RANDOM, TRANSVERSE, AND LONGITUDINAL CRACKING OF ASPHALT PAVEMENT OVER STRUCTURE AND
AT APPROACHES.
222.7 ONE HEADWALL MARKER PRESENT ON EAST AND WEST SIDES.
STRUCTURE LOAD RATING STRUCTURE NO. 5570-314P
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H 39 35 66 60
HS 82 74 136 123
TYPE 3 63 57 105 95
TYPE 3S2 95 86 159 144
TYPE 3-3 105 95 175 159
DESIGN LOADING: 4 - H 20
X CAPACITY MEETS OR EXCEEDS DESIGN LOAD
CAPACITY IS LESS THAN DESIGN LOAD
ORIGINAL LOAD RATING CALCULATION APPLICABLE
ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION: 03/14/2016
LOAD RATING CONTROLLED BY: TOP SLAB - POSITIVE MOMENT
REMARKS: SEE STRUCTURE FILE FOR LOAD RATING CALCULATIONS.
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5570-314P
STRUCTURE IDENTIFICATION
(201) PARK: NATCHEZ TRACE PARKWAY
(202) STRUCTURE NAME:..............CULVERT AT MP 128.30
(203) STRUCTURE KIND:............... 2 - CULVERT
(204) STRUCTURE NUMBER:.........5570-314 P
4 - SOUTHEAST(205) NPS REGION:
(206) ROUTE CODE NUMBER:
(207) ROAD SECTION NO:............. 314P
(208) NPS ROAD CLASS:............... 1 - PRINCIPAL PARK ROAD
(209) WITHIN NPS BNDRY?:.......... Yes
(210) OPERATING UNIT:.................RIDGELND
(211) PROJECT NO(S):................... 3N1
(212) DRAWING NUMBERS:
(21) MAINTAINED BY:......................66 - NATIONAL PARK SERVICE
(22) OWNER:................................... 66 - NATIONAL PARK SERVICE
(1) STATE:
(2) STATE HWY. AGENCY DIST:
(3) COUNTY CODE:
(4) CITY / PLACE CODE:
(5) INVENTORY ROUTE:
(6) FEATURES INTERSECTED:
(7) FACILITY CARRIED:
(8) STATE STRUCTURE NO:
(9) LOCATION:
(10) INV. RTE. - MIN. VERT. CLR:
(11) MILE POINT:
(27) YEAR BUILT:
(106) YEAR RECONSTRUCTED:
(20) TOLL:
(37) HISTORIC DESIGNATION:
284 - MISSISSIPPI
28079 LEAKE
00000
1 6 1 00001 0
STREAM
NATCHEZ TRACE PARKWAY
5570314P0000000
6 8 MILES TO MS ROUTE 16
99.99 FT ( 99.99 M)
128.3 (KM PT: 206.4)
0 3
3 - ON FREE ROAD
5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL:..........1 - CONCRETE (44A) APPR. STR. MATERIAL:............ 0 - Other
(43B) MAIN STR. TYPE:.................. 19 - CULVERT (INCLUDES FRAME (44B) APPR. STR. TYPE:.................... 00 - OTHER
CULVERTS)
(45) NO. OF MAIN SPANS:..............3 (46) NO OF APPROACH SPANS:
(48) MAX. SPAN LENGTH:..............9.0 FT ( 2.7 M)
(49) STRUCTURE LENGTH:........... 26.0 FT ( 7.9 M) (108) WEAR SURFACE/PROTECT SYSTEM:
(216A) ABUTMENT #1 FDN:........... 2 - SPREAD FTG ON BEARING MAT'L A) TYPE WEARING SURFACE:.. N - NA
(216B) ABUTMENT #2 FDN:........... 2 - SPREAD FTG ON BEARING MAT'L B) TYPE MEMBRANE:................. N - NA
(217A) PREDOM. PIER FDN:.......... 2 - SPREAD FTG ON BEARING MAT'L C) TYPE PROTECTION:.............. N - NA
(217B) SECOND. PIER FDN:.......... 2 - SPREAD FTG ON BEARING MAT'L (218) IS SALT USED?.......................... NO
(107) DECK TYPE:.......................... N - NOT APPLICABLE
LOAD RATING AND POSTING
(31) DESIGN LOAD:.........................4 - H 20 (41) LOAD RESTRICTION:.................. A - OPEN
(66) INVENTORY RATING:..............82.0 METRIC TONS) (70) BRIDGE POSTING:...................... 5 - EQUAL TO OR ABOVE LEGALTONS ( 74.4
LOADS
(64) OPERATING RATING:..............99.9 TONS ( 90.6 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 03/15/2022 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL:.......... N
(220) SPECIAL STUDY TYPE: 0 - NONE INSP. EVERY MONTHS - LAST INSP:
(221) SPECIAL STUDY DATE: (B) UNDERWATER:..................... N
INSP. EVERY MONTHS - LAST INSP:
(C) SPECIAL INSPECTION:........ N
INSP. EVERY MONTHS - LAST INSP:
https://RATING:
https://RATING:
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5570-314P
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(16) LATITUDE:................................ 32° 38'30.10" (51) CURB TO CURB WIDTH:............ 0 0 FT ( 0 M)
(17) LONGITUDE:............................ 89°47 '54 00" (52) DECK WIDTH:.......................... 0 0 FT ( 0 M)
(19) DETOUR LENGTH:.................. 24 MI ( 39 KM) (32) APPR. ROADWAY WIDTH:...... 34.0 FT ( 10.4 M)
(28A) LANES ON STRUCT:.............02 (213) APPR. PAVEMENT WIDTH:... 22.0 FT ( 6.7 M)
(28B) LANES UNDER STRUCT:......00 LEFT SHOULDER:............... 6 0 FT ( 1.8 M)
(42A) SERVICE ON:.........................1 - HIGHWAY RIGHT SHOULDER:.......... 6 0 FT ( 1.8 M)
(42B) SERVICE UNDER:................. 5 - WATERWAY (33) BRIDGE MEDIAN:.................... 0 - NO MEDIAN
(29) AVG DAILY TRAFFIC:..............2080 (34) SKEW ANGLE:......................... 0 °
(30) YEAR OF ADT:......................... 2012 (35) STRUCTURE FLARED:............ 0 - NO FLARE
(114) FUTURE ADT:.........................2288 (47) TOTAL HORIZ. CLEARANCE:.. 34 FT ( 10.4 M)
(115) YEAR OF FUTURE ADT:........2032 (50) SIDEWALKS
(101) PARALLEL STRUCTURE:......N - NO PARALLEL STRUCTURE LEFT:.................................... 0 0 FT ( 0 M)
(38) NAVIGATION CONTROL:.........0 - NO NAVIGATION CONTROL ON RIGHT:.................................. 0 0 FT ( 0 M)
WATERWAY (BRIDGE PERMIT NOT
REQUIRED)
(39) VERTICAL CLEARANCE:.........0.0 FT ( 0 M) (214) BRIDGE RAIL TYPE
0 - N/A(40) HORIZ. CLEARANCE:..............0.0 FT ( 0 M) RAIL CONFIGURATION:
(111) ABUT OR PIER PROT:........... MATERIAL:........................... 0 - N/A
LATERAL UNDERCLEARANCE: DESIGN TYPE:..................... 0 - N/A
(55) RIGHT:..............................99.9 FT ( 30.45 M) (215) BRIDGE RAIL HEIGHT:.......... 0 00 FT ( 0 M)
(56) LEFT:................................ 0.0 FT ( 0 M) (53) MIN. VRT. CLR. OVER DECK: 99.99 FT ( 99.99 M)
(54) MIN. VRT. UNDRCLRANCE:... 0 00 FT ( 0 M)
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK:....................................... N (67) STRUCTURAL EVALUATION:
(59) SUPERSTRUCTURE:...............N (68) DECK GEOMETRY:......................N
(60) SUBSTRUCTURE:.......... N (69) UNDERCLEARANCES:................ N
(61) CHANNEL:................................5 (71) WATERWAY ADEQUACY:
(62) CULVERT:.................................6 (72) APPROACH ALIGNMENT:
(222) APPROACHES:...................... 6 (113) SCOUR CRITICAL:.................... 5 - SCOUR WITHIN LIMITS OF
FOOTING OR PILES
(223) RETAINING WALL:.................N (225) PURPOSE OF IMPROVEMENT: 2 - REHAB/RECONSTRUCTION
(36) TRAFFIC SAFETY FEAT: N N N N (226) PRIORITY OF IMPROVEMENT: C - MODERATE
(75A) TYPE OF WORK:................... (227) MAINTENANCE COST:.............$ 1000
(75B) WORK DONE BY:.................. (228) REHAB / RECNSTR COST:..... $ 34000
(76) IMPROVEMENT LENGTH:....... FT ( 0 M) (229) CONSTRUCTION COST:.......... $ 0
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
(231) ADDITIONAL CONSIDERATIONS:
(330) ADDITIONAL CONFIGURATION INFORMATION:
https://RIGHT:
https://38'30.10
Inspector: David Martin Structure Number: 5570314P0000000
Inspection Date: 03/15/2022 Facility Carried: NATCHEZ TRACE PAR
Culvert Inspection Report
Pictures
PHOTO 3
Description LOOKING SOUTHBOUND TOWARD JACKSON
PHOTO 4
Description WEST (UPSTREAM) SIDE; NOTE DEBRIS ACCUMULATION
Culvert Inspection Report
Pictures
PHOTO 5
Description GENERAL TOPSIDE VIEW LOOKING SOUTH; NOTE LONGITUDINAL AND TRANSVERSE
CRACKING OF WEARING SURFACE
PHOTO 6
Description GENERAL UNDERSIDE VIEW LOOKING EAST, NORTH BARREL
Culvert Inspection Report
Pictures
PHOTO 7
Description TRANSVERSE CRACKING OF WEARING SURFACE OVER NORTH BARREL
PHOTO 8
Description GENERAL VIEW OF SOUTH END WALL
Culvert Inspection Report
Pictures
PHOTO 9
Description GENERAL VIEW OF SOUTH INTERMEDIATE WALL, SOUTH FACE
PHOTO 10
Description GENERAL VIEW OF NORTH INTERMEDIATE WALL, NORTH FACE
Culvert Inspection Report
Pictures
PHOTO 11
Description LOOKING WEST THROUGH NORTH BARREL
PHOTO 12
Description GENERAL VIEW OF NORTH END WALL
Culvert Inspection Report
Pictures
PHOTO 13
Description LONGITUDINAL CRACKING ON NORTHWEST WINGWALL; NOTE EROSION AND
VEGETATION GROWTH
PHOTO 14
Description CRACKING ON EAST HEADWALL OVER NORTH BARREL
Culvert Inspection Report
Pictures
PHOTO 15
Description LONGITUDINAL CRACKING ON TOP OF NORTHEAST WINGWALL; NOTE EROSION TRENCH
AND VEGETATION GROWTH
PHOTO 16
Description ACCUMULATION OF SILT AND DEBRIS IN DOWNSTREAM CHANNEL
Culvert Inspection Report
Pictures
PHOTO 17
Description UPSTREAM CHANNEL
PHOTO 18
Description DOWNSTREAM CHANNEL
File details come from the government source that posted it. Updated .