About this file

This is an electrical power plan document prepared by the Commonwealth of Kentucky's Finance and Administration Cabinet, Department for Facilities & Support Services, Division of Engineering, in coordination with professional engineers KLH Engineers, PSC, for the Gateway Urban Campus located at 438-440 Scott Street in Covington, Kentucky. The document, dated December 18, 2015, provides detailed mechanical and electrical specifications for the first-floor renovation of a classroom center facility that includes multiple functional spaces: a dispensary, cosmetology salon, manicure/pedicure area, waiting area, reception area, consultation room, men's and women's restrooms, storage area, and custodial space. The electrical design specifies new power distribution, lighting installations, fire alarm systems, HVAC controls, and communication infrastructure for the renovation project. Key requirements include coordination with custom casework prior to rough-in, provision of recessed activation floor boxes with single and double duplex receptacles, exhaust fan controls linked to room lighting with occupancy sensors, and styling station furniture power supplies featuring double duplex receptacles fed from individual 20-ampere circuits.

The plan establishes specific technical requirements and installation standards, including the reuse of existing pathways and backboxes where feasible, with new boxes and conduit concealed within walls rather than surface-mounted. All wall receptacles are to be centered in eight-inch baseboards unless otherwise specified, and existing tin ceiling elements must remain undamaged. The document includes notation that east/west dimensions may shift plus or minus two inches depending on floor joist locations. Circuit designations, fixture locations, and candela ratings for lighting are specified throughout the plan, with numerous keyed notes addressing coordination requirements between electrical installation, architectural furniture specifications, and equipment vendors to ensure proper installation locations and functionality prior to construction rough-in phases.

View the file

Other files

File Type Posted
66-67 - CT0.0.pdf PDF
51-49 - HV1.3.pdf PDF
8-13 - A1-1 - FIRST FLOOR DEMOLITION AND NEW WORK PLANS.pdf PDF
34-35 - PD1.1.pdf PDF
30-30 - A8-2 - Basement - FINISHES.pdf PDF
29-29 - A8-1 - ROOM FINISH PLANS (N-I-C- FURNITURE LAYOUT).pdf PDF
12-11 - S4-2 - FRAMING DETAILS.pdf PDF
15-8 - S2-5 - ROOF FRAMING PLAN.pdf PDF
73-19 - A3-0 - BUILDING ELEVATIONS.pdf PDF
49-51 - HV2.0.pdf PDF
72-72 - CT5.2.pdf PDF
67-69 - CT1.2.pdf PDF
62-63 - EP4.0.pdf PDF
3-6 - S2-3 - SECOND FLOOR FRAMING PLAN.pdf PDF
23-24 - A5-2 - MISCELLANEOUS DETAILS.pdf PDF
43-46 - HV1.0.pdf PDF
17-3 - S1-1 - GENERAL NOTES.pdf PDF
13-18 - A2-1 - 2ND 3RD FLR REFLECTED CLG PLANS.pdf PDF
28-31 - A8-3 - 1st FLOOR - FINISHES.pdf PDF
21-23 - A5-1 - MISCELLANEOUS STAIR DETAILS.pdf PDF
70-71 - CT5.1.pdf PDF
36-37 - PL1.1.pdf PDF
42-44 - FP1.1.pdf PDF
31-32 - A8-4 - 2nd Floor - FINISHES.pdf PDF
32-33 - A8-5 - 3rd Floor - FINISHES.pdf PDF
50-52 - HV2.1.pdf PDF
38-40 - PL1.4.pdf PDF
35-34 - PD1.0.pdf PDF
69-70 - CT4.1.pdf PDF
39-39 - PL1.3.pdf PDF
11-12 - A1-0 - BASEMENT DEMOLITION AND NEW WORK PLANS.pdf PDF
68-68 - CT1.0.pdf PDF
25-26 - A6-1 - ENLARGED PLANS AND INTERIOR ELEVATIONS.pdf PDF
63-64 - EL1.0.pdf PDF
19-10 - S4-1 - FRAMING DETAILS.pdf PDF
65-66 - EL2.0.pdf PDF
2-2 - A0-1 - CODE INFO AND WALL TYPES.pdf PDF
9-14 - A1-2 - SECOND FLOOR DEMOLITION AND NEW WORK PLANS.pdf PDF
76-Elevator Inspection 2026-03-25-12-13-48.pdf PDF
58-59 - EP1.3.pdf PDF
46-47 - HV1.1.pdf PDF
57-58 - EP1.2.pdf PDF
61-62 - EP3.0.pdf PDF
80-438 Scott Full Inspection Report (PDF).pdf PDF
7-5 - S2-2 - FIRST FLOOR FRAMING PLAN.pdf PDF
53-54 - HV3.1.pdf PDF
4-9 - S3-1 - TYPICAL DETAILS.pdf PDF
1-4 - S2-1 - FOUNDATION PLAN.pdf PDF
24-25 - A6-0 - ENLARGED PLANS AND INTERIOR ELEVATIONS.pdf PDF
48-50 - HV1.4.pdf PDF
Show 40 more

Latest 50 of 80 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T

T

DSD

DSD

S

J

J

J

T

T

S S S

S

S S

S

B C D EA G

F

EWC

HVAC

DISPENSARY

CORRIDOR

100B

COSMETOLOGY SALON

WAITING AREA

RECEPTION

100A

CONSULTATION

100C

MANICURE/PEDICURE

AREA

100D

EXISTING STAIR

B

STAIR

D1

MEN

WOMEN

STORAGE

CORRIDOR

100E

WASHER

DRYER

TV

GFCI

- 11A

- 21A

- 31A

- 41A

- 61A

- 5,71A

- 81A

30 cd

75 cd

75 cd

75 cd

75 cd

75 cd

30 cd75 cd

CUSTODIAL

107ACU-1-01

ACU-1-02

- 201A

- 211A

- 221A

- 231A

- 241A

- 251A

- 261A

- 271A

- 281A - 291A

- 301A

- 311A

- 321A

- 331A

- 341A

- 351A

P-1

P-2

EF-1

ECH-1

- 361A

- 371A

GFCI

GFCI

GFCI

GFCI

GFCI

- 27,291B

- 26,281B

7 - 30,321B

FARA

12 12

FIRE PROTECTION BELL

FIREWALL (TYP.)

GFCI

GFCI

GFCI

30 cd

GFCI

SIGNAGE

ABOVE

DOORWAY

- 391A

FUTURE

HAND

DRYER

FUTURE

HAND

DRYER

- 311B

- 331B

1C

- 11C

- 31C

- 51C

- 71C

- 91C

- 111C

- 131C

- 151C

- 21C

- 41C

- 61C

- 81C

- 101C

- 121C

- 141C

- 161C

- 301C

- 321C

- 261C

- 281C

- 221C

- 241C

- 181C

- 201C

- 291C

- 311C

- 251C

- 271C

- 211C

- 231C

- 171C

- 191C

- 331C - 371C

- 351C - 391C

- 341C - 381C

- 361C - 401C

2' - 8" 5' - 6"5' - 6" 2' - 10"

0' - 10" 5' - 6" 5' - 6" 4' - 8"

6' - 5" 5' - 9"

1' - 5"

6' - 3"

1' - 1" 6' - 11" 5' - 3"

11' - 4"

0' - 6"

- 171A

- 401A

- 231B

B C D EA G

F

APPROVED FOR PROGRAM CONCEPT ONLY

APPROVED FOR PROGRAM CONCEPT ONLY

DATE

DATE

ENGINEERING

DIVISION OF

AGENCY

AUTHORIZED AGENT

FOR INTENT ONLY

DIV. OF ENGR.

REVIEWED

ENGR. ACCT NO.

DRAWING NO.

DATE

A&E FILE NO.

CHECKED BY

SHEET DRAWN BY

RECORD DATE

DATEREVISIONS

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES & SUPPORT SERVICES

DIVISION OF ENGINEERING

FRANKFORT, KENTUCKY

WWW.KLHENGRS.COM

ENGINEERS, PSC

MECHANICAL/ELECTRICAL ENGINEERS

KOHRS LONNEMANN HEIL

LEXINGTON, KENTUCKY

COLUMBUS, OHIO

DAYTON, OHIO

NEW YORK, NEW YORK

1538 ALEXANDRIA PIKE, SUITE

11 FT. THOMAS, KENTUCKY

41075 800-354-9783 859-442-8050

859-442-8058 FAX

KLH PRO. NO.

11369.04

PROFESSIONAL SERVICES CLASSROOM CENTER

/1

/2

:1 :0

P

M

EP1.1

ELECTRIC POWER - NEW AND

DEMOLITION - 1ST FLOOR

470-C5N5-NC11-01

GATEWAY URBAN CAMPUS

438-440 Scott St., Covington, KY 41011

12/18/15

201114.02

DTJ

SNF

SCALE: 1/4" = 1'-0"EP1.1

1 ELECTRIC POWER - NEW - 1ST FLOOR

SCALE: 1/4" = 1'-0"EP1.1

2 ELECTRIC - DEMOLITION - 1ST FLOOR

DEMOLITION GENERAL NOTES

A. ALL ELECTRICAL (POWER, LIGHTING, FIRE ALARM, AND COMMUNICATION)

DEVICES, PANELS, ETC. SHALL BE DEMOLISHED IN THEIR ENTIRETY

UNLESS OTHERWISE INDICATED TO BE RELOCATED OR TO REMAIN

(INDICATED AS EXISTING). ALL DEVICES NOTED TO REMAIN SHALL BE

PROTECTED DURING DEMOLITION. SEE SPECIFICATIONS FOR ADDITIONAL

DEMOLITION NOTES.

KEYED NOTES

2 COORDINATE POWER REQUIREMENTS AND LOCATIONS WITH

CUSTOM CASEWORK PRIOR TO ROUGH IN. STUB POWER / DATA

RACEWAYS UP FROM BELOW INTO CASEWORK.

3 PROVIDE POWER ONLY (SINGLE DUPLEX RECEPTACLE) RECESSED

ACTIVATION FLOOR BOX. COORDINATE EXACT LOCATION WITH

ARCHITECTURAL FURNITURE DRAWINGS PRIOR TO ROUGH IN.

7 EXHAUST FAN TO BE CONTROLLED ALONG WITH ROOM LIGHTING.

TIE INTO LIGHTING CONTROL CIRCUIT. PROVIDE ADDITIONAL

OCCUPANCY SENSOR RELAY PACKS AS REQUIRED.

10 COORDINATE EXACT LOCATION OF FIRE ALARM REMOTE

ANNUNCIATOR WITH OWNER AND FIRE DEPARTMENT PRIOR TO

ROUGH IN.

11 PROVIDE POWER TO STYLING STATION FURNITURE. EACH SIDE OF

THE STYLING STATIONS WILL BE FURNISHED WITH A DOUBLE

DUPLEX (QUAD) RECEPTACLE. EACH DUPLEX SHALL BE FED FROM

A SINGLE 20A CIRCUIT. PROVIDE CONDUIT AND WHIPS FROM

BELOW TO EACH RECEPTACLE. COORDINATE CONDUIT ROUTING

AND BOX REQUIREMENTS IN FIELD AND WITH FURNITURE VENDOR.

12 COORDINATE MOUNTING HEIGHTS WITH ARCHITECTURAL

DRAWINGS PRIOR TO ROUGH IN.

15 PROVIDE POWER ONLY (DOUBLE DUPLEX RECEPTACLE)

RECESSED ACTIVATION FLOOR BOX. COORDINATE EXACT

LOCATION WITH ARCHITECTURAL FURNITURE DRAWINGS PRIOR

TO ROUGH IN.

DEMOLITION GENERAL NOTES

A. ALL ELECTRICAL (POWER, LIGHTING, FIRE ALARM, AND COMMUNICATION)

DEVICES, PANELS, ETC. SHALL BE DEMOLISHED IN THEIR ENTIRETY

UNLESS OTHERWISE INDICATED TO BE RELOCATED OR TO REMAIN

(INDICATED AS EXISTING). ALL DEVICES NOTED TO REMAIN SHALL BE

PROTECTED DURING DEMOLITION. SEE SPECIFICATIONS FOR ADDITIONAL

DEMOLITION NOTES.

GENERAL NOTES

A. EXISTING PATHWAYS AND BACKBOXES MAY BE RE-USED ON EXISTING

WALLS TO REMAIN WHERE POSSIBLE. WHERE NOT POSSIBLE, NEW

BOXES AND CONDUIT SHALL BE CONCEALED WITHIN WALLS. SURFACE

MOUNTING SHALL NOT BE USED. COORDINATE WITH GENERAL

CONTRACTOR AND PATCH / REPAIR WALLS AS NEEDED TO RECESS

PATHWAYS AND BOXES.

B. ALL WALL RECEPTACLES TO BE INSTALLED CENTERED IN 8"

BASEBOARDS (HORIZONTALLY) UNLESS SHOWN AS ABOVE COUNTER

OR NOTED OTHERWISE.

C. DO NO DAMAGE EXISTING FIRST FLOOR TIN CEILING.

NORTH

PLAN

EAST / WEST DIMENSIONS MAY SHIFT +/- 2 INCHES

DEPENDING ON FLOOR JOIST LOCATIONS

3 PR-016 - Styling Stations

8/8/2014

4 Electrical Dimensions 9/18/2014

File details come from the government source that posted it. Updated .