5-1 - COV - COVER SHEET.pdf

PDF 303 KB Posted

Attached to
Surplus Real Property Sale For Economic Development; 438 Scott Boulevard
Solicitation number
RFP260305
Issued by
Hart County, Kentucky

About this file

This is a cover sheet for construction design documents prepared by the Commonwealth of Kentucky, Finance and Administration Cabinet, Department for Facilities Management, Division of Engineering and Contract Administration, in conjunction with the Gateway Community & Technical College for a professional services classroom center renovation project located at 438-440 Scott Boulevard in Covington, Kentucky. The project involves comprehensive renovation work including structural, mechanical, electrical, plumbing, and fire protection systems across multiple floors of an existing building. The design documents include detailed plans, specifications, and construction details across numerous sheets covering demolition, new construction, reflected ceiling plans, building elevations, sections, stairs, door schedules, room finishes, and mechanical/electrical/plumbing systems. The project is designed by Brown + Kubican, PSC (structural) and Kohrs Lonnemann Heil Engineers, PSC (mechanical/electrical), with architectural services provided by a firm located at 201 West Short Street, Suite 700, Lexington, Kentucky. The cover sheet was prepared on January 5, 2016, with an as-built date of December 18, 2015, and serves as the foundational drawing index for the entire construction document set.

The contract documents establish comprehensive requirements for all contractors and subcontractors, making clear that contractors must bid the entire set of drawings and are responsible for identifying and resolving conflicts between documents prior to bid submission, with no compensation available for missed scope. All contractors must comply with applicable federal, state, and local building codes and industry standards including ASTM standards, verify all field conditions and dimensions before proceeding, provide blocking and securing for all wall, floor, and ceiling-mounted items, and coordinate all penetrations through building systems. The documents specify requirements for fire-rated assemblies, access panels, tempered and laminated glazing, pressure-treated materials at exterior and concrete locations, sealants to ensure watertight enclosure, and proper separation of non-compatible metals to prevent galvanic action.

View the file

Other files

File Type Posted
66-67 - CT0.0.pdf PDF
51-49 - HV1.3.pdf PDF
8-13 - A1-1 - FIRST FLOOR DEMOLITION AND NEW WORK PLANS.pdf PDF
34-35 - PD1.1.pdf PDF
30-30 - A8-2 - Basement - FINISHES.pdf PDF
29-29 - A8-1 - ROOM FINISH PLANS (N-I-C- FURNITURE LAYOUT).pdf PDF
12-11 - S4-2 - FRAMING DETAILS.pdf PDF
15-8 - S2-5 - ROOF FRAMING PLAN.pdf PDF
73-19 - A3-0 - BUILDING ELEVATIONS.pdf PDF
49-51 - HV2.0.pdf PDF
72-72 - CT5.2.pdf PDF
67-69 - CT1.2.pdf PDF
62-63 - EP4.0.pdf PDF
3-6 - S2-3 - SECOND FLOOR FRAMING PLAN.pdf PDF
23-24 - A5-2 - MISCELLANEOUS DETAILS.pdf PDF
43-46 - HV1.0.pdf PDF
17-3 - S1-1 - GENERAL NOTES.pdf PDF
13-18 - A2-1 - 2ND 3RD FLR REFLECTED CLG PLANS.pdf PDF
28-31 - A8-3 - 1st FLOOR - FINISHES.pdf PDF
21-23 - A5-1 - MISCELLANEOUS STAIR DETAILS.pdf PDF
70-71 - CT5.1.pdf PDF
36-37 - PL1.1.pdf PDF
42-44 - FP1.1.pdf PDF
31-32 - A8-4 - 2nd Floor - FINISHES.pdf PDF
32-33 - A8-5 - 3rd Floor - FINISHES.pdf PDF
50-52 - HV2.1.pdf PDF
38-40 - PL1.4.pdf PDF
35-34 - PD1.0.pdf PDF
69-70 - CT4.1.pdf PDF
39-39 - PL1.3.pdf PDF
11-12 - A1-0 - BASEMENT DEMOLITION AND NEW WORK PLANS.pdf PDF
68-68 - CT1.0.pdf PDF
25-26 - A6-1 - ENLARGED PLANS AND INTERIOR ELEVATIONS.pdf PDF
63-64 - EL1.0.pdf PDF
19-10 - S4-1 - FRAMING DETAILS.pdf PDF
65-66 - EL2.0.pdf PDF
2-2 - A0-1 - CODE INFO AND WALL TYPES.pdf PDF
9-14 - A1-2 - SECOND FLOOR DEMOLITION AND NEW WORK PLANS.pdf PDF
76-Elevator Inspection 2026-03-25-12-13-48.pdf PDF
58-59 - EP1.3.pdf PDF
46-47 - HV1.1.pdf PDF
57-58 - EP1.2.pdf PDF
61-62 - EP3.0.pdf PDF
80-438 Scott Full Inspection Report (PDF).pdf PDF
7-5 - S2-2 - FIRST FLOOR FRAMING PLAN.pdf PDF
53-54 - HV3.1.pdf PDF
4-9 - S3-1 - TYPICAL DETAILS.pdf PDF
1-4 - S2-1 - FOUNDATION PLAN.pdf PDF
24-25 - A6-0 - ENLARGED PLANS AND INTERIOR ELEVATIONS.pdf PDF
48-50 - HV1.4.pdf PDF
Show 40 more

Latest 50 of 80 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

THE PURPOSE OF THE CONTRACT DOCUMENTS IS TO PROVIDE DESIGN INTENT. IN SOME INSTANCES THE DOCUMENTS REQUIRE PROPRIETARY COMPONENTS TO MEET THE OWNER'S NEED BUT IN MOST CASES THIS IS ACCOMPLISHED IN A NONPROPRIETARY MANNER, AND AS SUCH, IS NOT TIED TO ANY MANUFACTURER'S SPECIFIC PRODUCTS OR INSTALLATION METHODS. EACH SUBCONTRACTOR OR TRADE CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR UPON AWARD OF CONTRACT OF ANY SYSTEM REQUIREMENTS THAT WILL ALTER DIMENSIONS AS SHOWN ON DRAWINGS AS A RESULT OF ACTUAL APPROVED PRODUCTS. ALL CONTRACTORS ADJACENT WORK SHALL PROVIDE NECESSARY QUANTITY REVISIONS WITHOUT ADDITIONAL COST. IT IS THE RESPONSIBILITY OF THE VENDOR TO PROVIDE ADDITIONAL COMPONENTS REQUIRED FOR COMPLETE SYSTEMS. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING ACTUAL CONDITIONS IN THE FIELD, AND THE MEANS AND METHODS OF CONSTRUCTION. THIS MAY NECESSITATE MINOR DEVIATIONS FROM THE DRAWN DETAILS. IF THE DRAWINGS AND/OR SPECIFICATIONS CONFLICT WITH A SPECIFIC MANUFACTURER'S MATERIALS, INSTALLATION DETAILS, RECOMMENDATIONS, OR INDUSTRY STANDARDS THE GENERAL CONTRACTOR AND RESPECTIVE SUB CONTRACTOR(S) ARE RESPONSIBLE FOR COORDINATING ANY AND ALL SPECIFIC CHANGES RELATED TO THE MATERIALS OR PRODUCTS SELECTED WITHOUT ADDITIONAL COST TO THE OWNER. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR MEETING THE DESIGN INTENT.

CHANGE ORDERS FOR REVISIONS COVERED BY THESE PROVISIONS WILL NOT BE CONSIDERED.

THE CONTRACT DOCUMENTS (PLANS/SPECS/FRONT END) ARE COMPLEMENTARY, WHAT IS REQUIRED BY ONE SHALL BE AS IF REQUIRED BY ALL. THE SPECIFICATIONS ARE NOT INTENDED TO BE A COMPREHENSIVE LIST OF WORK INTENDED. THE GENERAL CONTRACTOR AND SUB CONTRACTORS SHALL CAREFULLY EXAMINE ALL OF THE CONTRACT DOCUMENTS, AND BIDDING THE WORK GIVE A REPRESENTATION THEY HAVE FOUND THEM IN ALL RESPECTS TO BE COMPLETE, ACCURATE, CONSISTENT, COORDINATED, AND SUFFICIENT FOR CONSTRUCTION. CONTRACTORS ARE REQUIRED TO BID ENTIRE SET OF DRAWINGS. NO COMPENSATION WILL BE MADE FOR MATERIAL OR LABOR THAT WAS MISSED DUE TO AN INCOMPLETE BID. EACH DISCIPLINES

DRAWINGS MAY NOT BE CONCLUSIVE. VERIFY ALL DRAWINGS FOR TOTAL CONSTRUCTION. NO

COMPENSATION SHALL BE MADE AFTER BID FOR MISSED SCOPE.

IF THERE IS A CONFLICT BETWEEN DRAWINGS, OR BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, THE GENERAL CONTRACTOR IS TO BRING IT TO THE ATTENTION OF THE ARCHITECT PRIOR TO THE BID. IF THE GENERAL CONTRACTOR DOES NOT BRING THE CONFLICTS TO THE ATTENTION OF THE ARCHITECT, THEN HE HAS ASSUMED TO HAVE BID THE WORST CASE (MOST EXPENSIVE) SCENARIO. CHANGE ORDERS FOR

REVISIONS COVERED BY THESE PROVISIONS WILL NOT BE CONSIDERED.

APPLICABLE CONSTRUCTION INDUSTRY STANDARDS AND BUILDING CODES HAVE THE SAME FORCE AND EFFECT ON PERFORMANCE OF THE WORK AS IF COPIED DIRECTLY INTO THESE CONSTRUCTION DOCUMENTS.

GOVERNING REGULATIONS HAVE PRECEDENCE OVER NON-REFERENCED STANDARDS, IN SO FAR AS DIFFERENT STANDARDS MAY CONTAIN OVERLAPPING OR CONFLICTING REQUIREMENTS. COMPLY WITH FEDERAL, STATE AND LOCAL BUILDING CODES AND INDUSTRY STANDARDS. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH THESE STANDARDS AND REGULATIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND SUBCONTRACTORS TO VERIFY AND ENSURE LOCAL MUNICIPAL CODE REQUIREMENTS ARE MET. NOTIFY DESIGN TEAM PRIOR TO AWARD OF CONTRACT WHERE CONFLICTS ARISE. WHERE DISCREPANCIES EXIST BETWEEN THE DOCUMENTS FROM THE DESIGN PROFESSIONAL AND THE CODE, THE MOST RESTRICTIVE SHALL APPLY. NO COMPENSATION WILL BE MADE AFTER BID AWARD TO BRING WORK

INTO COMPLIANCE.

EACH CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE AND REPORT ANY DISCREPANCY TO THE ARCHITECT BEFORE PROCEEDING WITH CONSTRUCTION OR ORDERING MATERIALS. USE OF ESTABLISHED DIMENSIONS IS NOT PERMITTED UNLESS NOTED OTHERWISE IN THE SPECIFICATION SECTIONS. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTIONS THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING.

ALL WORK INCLUDED ON THESE DRAWINGS IS NEW AND BY CONTRACTOR UNLESS NOTED OTHERWISE.

ALL SECTIONS, DETAILS, MATERIALS, AND METHODS SHOWN AND / OR NOTED ON ANY SHEET SHALL APPLY TO

ALL OTHER SIMILAR LOCATIONS UNLESS NOTED OTHERWISE.

NO CONTRACTOR HAS THE AUTHORITY TO PERMIT THE USE OF ANY PORTION OF THE SITE OR BUILDING TO ANYONE, EXCEPT FOR BUSINESS CONNECTED TO THE CONSTRUCTION WITH WHICH THIS CONTRACT IS

CONCERNED.

REMOVE AND LEGALLY DISPOSE OF DEBRIS, RUBBISH AND OTHER DEMOLITION WASTE MATERIALS FROM THE

SITE.

THE CONTRACTOR SHALL KEEP A CURRENT EDITION OF THE APPLICABLE BUILDING CODE AT THE JOB TRAILER

AND REFER TO IT FOR ISSUES PERTAINING TO CODE COMPLIANCE.

THE CONTRACTOR SHALL STABILIZE AND SECURE BUILDING COMPONENTS AS REQUIRED.

THE CONTRACTOR SHALL FOLLOW ASTM STANDARDS FOR INSTALLATION REQUIREMENTS.

IN THE EVENT THE CONTRACTOR UNEXPECTEDLY ENCOUNTERS ON THE SITE MATERIAL REASONABLY BELIEVED TO BE ASBESTOS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER CLASSIFIED HAZARDOUS MATERIAL, NOTIFY ARCHITECT OF THE DISCOVERY OF ANY HAZARDOUS MATERIALS AND IMMEDIATELY STOP WORK AND REPORT FINDINGS TO OWNER AND ARCHITECT IN WRITING AND DO NOT RESUME WORK UNTIL

APPROACH IS IDENTIFIED.

INSTALL ALL DOORS, EQUIPMENT, AND BUILDING COMPONENTS WITH DIMENSIONAL TOLERANCES IN COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT. WHERE CONFLICTS EXIST WITH THE CONTRACT

DOCUMENTS, NOTIFY ARCHITECT PRIOR TO PROCEEDING.

CONTRACTOR SHALL ASSUME THAT DIGITAL DRAWING FILES ARE NOT AVAILABLE UNLESS NOTED

OTHERWISE IN SPECIFICATION SECTIONS.

ALL DIMENSIONS SHOWN ON PLANS ARE TO CENTERLINE OF COLUMN, FACE OF MASONRY/CONCRETE/METAL FRAMING AND DO NOT INCLUDE THICKNESS OF FINISHES SUCH AS DRYWALL UNLESS OTHERWISE NOTED.

CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. REFER TO ENLARGED PLANS FOR

ADDITIONAL DIMENSIONS.

ALL DIMENSIONS ON INTERIOR ROOM ELEVATIONS ARE TO FACE OF FINISH UNLESS OTHERWISE NOTED.

THE CONTRACTOR SHALL PROVIDE BLOCKING FOR ALL ITEMS TO BE ANCHORED OR SECURED TO WALLS, FLOORS, AND CEILINGS WHICH MAY INCLUDE BUT IS NOT LIMITED TO CASEWORK, TOILET ACCESSORIES, MARKER AND BULLETIN BOARDS, TV BRACKETS, RAILS, GRAB BARS, CORNER GUARDS, WALL & CEILING MOUNTED EQUIPMENT, OWNER-FURNISHED CONTRACTOR-INSTALLED ITEMS, AND OWNER-FURNISHED OWNER-INSTALLED ITEMS. PROVIDE FIRE TREATED MATERIAL WHERE REQUIRED BY THE APPLICABLE

BUILDING CODE.

ALL WOOD BLOCKING / NAILERS SHALL BE PRESSURE TREATED WHEN IN CONTACT WITH CONCRETE OR MASONRY. PROVIDE PRESSURE TREATED BLOCKING AT EXTERIOR LOCATIONS AS SHOWN OR AS REQUIRED

FOR WARRANTY SYSTEM PERFORMANCE.

PROVIDE SHIMS BETWEEN BUILDING SYSTEMS AND COMPONENTS AS REQUIRED FOR PROPER ALIGNMENT.

SEPARATE NON-COMPATIBLE METALS AND DISSIMILAR MATERIALS TO PREVENT GALVANIC ACTION.

INSTALL SEALANTS BETWEEN BUILDING SYSTEMS AT BOTH INTERIOR AND EXTERIOR LOCATIONS TO ENSURE A WATERTIGHT ENCLOSURE. UTILIZE SHIMS, JOINT MATERIALS, AND BACKER RODS IN ORDER TO

CONTAIN SEALANTS. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

LOCATIONS OF TEMPERED AND LAMINATED SAFETY GLAZING SHALL BE PROVIDED WHERE NOTED, OR AS REQUIRED BY THE CURRENT EDITION OF THE APPLICABLE BUILDING CODE. REFER TO SPECIFICATIONS FOR

ADDITIONAL REQUIREMENTS.

ALL FLOOR OPENINGS AND CHASES SHALL BE CURBED OR SEALED TO PREVENT LEAKAGE TO LOWER FLOORS. PROVIDE FIRE-RATINGS AS REQUIRED BY CODES. AT GRATED OR PLATED OPENINGS, PROVIDE ADDITIONAL BRACING AND SUPPORTS AS REQUIRED BY ACTUAL MECHANICAL, ELECTRICAL, PLUMBING, AND

FIRE PROTECTION CONFIGURATIONS.

PROVIDE FIRE STOPPING, AND FIRE RATED ASSEMBLIES IN ALL RATED WALLS AND FLOORS.

PROVIDE ACCESS PANELS WHERE REQUIRED FOR ACCESS TO ALL EQUIPMENT INCLUDING MECHANICAL ELECTRICAL ITEMS. WHERE ACCESS PANEL SIZE IS NOT SHOWN, PROVIDE 2' X 2' PANEL. ACCESS PANELS

SHALL MATCH RATINGS OF SURROUNDING WALLS OR CEILINGS.

GENERAL CONTRACTOR IS TO BE RESPONSIBLE FOR COORDINATING ALL HVAC / EQUIPMENT PENETRATIONS THROUGH WALLS, FLOORS, AND ROOFS. THIS MAY INCLUDE ADDITIONAL SUPPORT AS UNIT SIZES AND

LOCATIONS CHANGE FROM WHAT IS SHOWN FOR WHATEVER REASON.

PROVIDE DRYWALL CONTROL JOINTS PER ASTM C-840 AND WHERE REQUIRED TO PREVENT CRACKING.

PROVIDE BRACES AT 60" ON CENTER AT ALL WALLS THAT DO NOT GO TO CEILING.

ALL WALLS, BULKHEADS, AND SOFFITS TO RECEIVE PAINT IF NOT SCHEDULED OTHERWISE.

REFER TO LINTEL SCHEDULES FOR MASONRY OPENINGS. PROVIDE STEEL LINTELS FOR ALL PENETRATIONS AND OPENINGS IN MASONRY, INCLUDING PENETRATIONS FOR MECHANICAL AND ELECTRICAL ITEMS, AND

FOR ITEMS RECESSED IN MASONRY.

SEE CODE SHEET FOR CODE REVIEW DATA.

Room name

150 SF

1i

MTL PNL

R 1t

Room name

303R3

1i

DOOR TAG

DOOR TAG - EGRESS

WALL TAG

WALL TAG - EGRESS

CEILING TAG

EQUIPMENT TAG

AREA TAG

X

XX

X

XX

XX

X

X

XX

EXTERIOR ELEVATION

INTERIOR ELEVATION

BUILDING SECTION

X

XX

WALL SECTION

X

XX

DETAIL SECTION

X

XX

DETAIL

X

XX

CALLOUT

1.5-HR

1-HR

A 1

ROOM TAG

RAILING TAG

REVISION TAG

WINDOW & CURTAIN

WALL TAG

X'-X"

SPOT ELEVATION

001001 SHEET NOTE EQUIPMENT NOTE

AFF ABOVE FINISHED FLOOR

ADD ADDENDUM

ADJ ADJACENT

A/C AIR CONDITIONING

ALT ALTERNATE

ALUM ALUMINUM

ARCH ARCHITECT(URAL)

BSMT BASEMENT

BM BEAM

BRG BEARING

BLKG BLOCKING

BD BOARD

BOT BOTTOM

B.O. BOTTOM OF

BLDG BUILDING

CLG CEILING

CIR CIRCLE

CLR CLEAR(ANCE)

CLOS CLOSET

COL COLUMN

CONC CONCRETE

CONST CONSTRUCTION

CONT CONTINUOUS

CJ CONTROL JOINTS

CF CUBIC FOOT

CY CUBIC YARD

DTL DETAIL

DIA DIAMETER

DIM DIMENSION

DW DISHWASHER

DWG DRAWING

DF DRINKING FOUNTAIN

E EAST

ELEC ELECTRIC

ELEV ELEVATOR

EQ EQUAL

EXIST EXISTING

EXP EXPANSION

EXT EXTERIOR

F.O.C. FACE OF CONCRETE

F.O.M. FACE OF MASONRY

FIN FINISH(ED)

FF FINISHED FLOOR

F.O. FINISHED OPENING

FE FIRE EXTINGUISHER

FD FLOOR DRAIN

FTG FOOTING

FND FOUNDATION

FR FRAME

GAL GALVANIZED

GA GAUGE

GC GENERAL CONTRACTOR

GYP GYPSUM

HCP HANDICAP(PED)

H.D.G. HOT DIPPED GALVANIZED

HVAC HEATING/VENTILATING/

AIR CONDITIONING

HT HEIGHT

HC HOLLOW CORE

HM HOLLOW METAL

HORIZ HORIZONTAL

INCL INCLUD(ED); -(ING)

ID INSIDE DIAMETER

INSUL INSULATION

INT INTERIOR

INV INVERT

JT JOINT

KIT KITCHEN

LAB LABORATORY

LL LIVE LOAD

MFR MANUFACTURER

MAS MASONRY

M.O. MASONRY OPENING

MAX MAXIMUM

MECH MECHANICAL

MED MEDIUM

MIN MINIMUM

MISC MISCELLANEOUS

MTD MOUNTED

NRC NOISE REDUCTION

COEFFICIENT

NOM NOMINAL

N NORTH

NIC NOT IN CONTRACT

N.T.S. NOT TO SCALE

O.C. ON CENTER

OPG OPENING

OPP OPPOSITE

OH OPPOSITE HAND

OD OUTSIDE DIAMETER

PTD PAINTED

PB PARTICLE BOARD

PVMT PAVEMENT

PL PLATE

PG PLATE GLASS

PLUMB PLUMBING

PLYWD PLYWOOD

PVC POLYVINYL CHLORIDE

PSI POUNDS PER SQUARE INCH

P.T. PRESSURE TREATED

RAD RADIUS

REF REFRIGERATOR

RCP REINFORCED CONCRETE PIPE

REV REVISION; REVISED

R.O.W. RIGHT OF WAY

RD ROOF DRAIN

RM ROOM

R.O. ROUGH OPENING

SCHD SCHEDULE

SECT SECTION

SIM SIMILAR

SC SOLID CORE

S SOUTH

SPEC SPECIFICATION

SQ SQUARE

S.S. STAINLESS STEEL

STD STANDARD

STL STEEL

STRUCT STRUCTURAL

SUSP SUSPENDED

TEL TELEPHONE

TV TELEVISION

THK THICK

T.B.D. TO BE DETERMINED

T&G TONGUE AND GROOVE

T.O. TOP OF

T.S. TUBE STEEL

TYP TYPICAL

UC UNDER COUNTER

U.L. UNDERWRITERS

LABORATORIES

U.O.N. UNLESS OTHERWISE NOTED

VB VAPOR BARRIER

VERT VERTICAL

WC WATER CLOSET

WWF WELDED WIRE FABRIC

W WEST

WDW WINDOW

W/ WITH

W/O WITHOUT

WD WOOD

C

COMMONWEALTH

T

R E

R

A

H C

I

N K

E

UT

OF

B

3 87

I

R E

G

No.

TS E

NT U

C E

YK T

N E R

D

ER

RB

APPROVED FOR PROGRAM CONCEPT ONLY

APPROVED FOR PROGRAM CONCEPT ONLY

DATE

DATE

ENGINEERING

DIVISION OF

AGENCY

AUTHORIZED AGENT

FOR INTENT ONLY

DIV. OF ENGR.

REVIEWED

ENGR. ACCT. NO.

DRAWING NO.

DATE

A&E FILE NO.

CHECKED BY

SHEET DRAWN BY

RECORD DATE

DATEREVISIONS

COMMONWEALTH OF KENTUCKY

STEVEN L. BESHEAR - GOVERNOR

LORI FLANERY- SECRETARY,

FINANCE & ADMIN. CABINET

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORTING SERVICES

DIVISION OF ENGINEERING

AND CONTRACT ADMINISTRATION

403 Wapping Street, The Bush Building Frankfort, KY 40601

DRAWING INDEX

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES MANAGEMENT

DIVISION OF ENGINEERING

FRANKFORT, KENTUCKY

GENERAL NOTES

OWNER

ABBREVIATIONS

SYMBOL LEGEND CONSULTANTS

201 W Short Street | Suite 700 Lexington, KY 40507 tel: 859-231-7538 | fax: 859-255-4380

ARCHITECT

USING AGENCY

LOCATION MAP

VICINITY MAP

COMMONWEALTH OF KENTUCKY

DIVISION OF ENGINEERING AND

CONTRACT ADMINISTRATION

403 WAPPING STREET

THE BUSH BUILDING

FRANKFORT, KY 40601

/5

/2

:5 :2

P

M C

U s e rs

\R H in s o n \D o c u m e n ts

\1

G

C T

C

A b o d e B u il d in g R e n o v a ti o n rh in s o n .r v t

COV

COVER SHEET

470-C5N5-NC11-01

GATEWAY URBAN CAMPUS

PROFESSIONAL SERVICES CLASSROOM CENTER

09/25/14

201114.02

BB

REH

GATEWAY URBAN CAMPUS

438-440 Scott St., Covington, KY 41011

470-C5N5-NC11-01 GATEWAY COMMUNITY &

TECHNICAL COLLEGE (GCTC)

1025 AMSTERDAM ROAD

COVINGTON, KY 41011

PROFESSIONAL SERVICES CLASSROOM CENTER

438-440 Scott St., Covington, KY 41011

SHEET

NUMBER SHEET NAME

COV COVER SHEET

A0.1 CODE INFO AND WALL TYPES

S1.1 GENERAL NOTES

S2.1 FOUNDATION PLAN

S2.2 FIRST FLOOR FRAMING PLAN

S2.3 SECOND FLOOR FRAMING PLAN

S2.4 THIRD FLOOR FRAMING PLAN

S2.5 ROOF FRAMING PLAN

S3.1 TYPICAL DETAILS

S4.1 FRAMING DETAILS

S4.2 FRAMING DETAILS

A1.0 BASEMENT DEMOLITION AND NEW WORK PLANS

A1.1 FIRST FLOOR DEMOLITION AND NEW WORK PLANS

A1.2 SECOND FLOOR DEMOLITION AND NEW WORK PLANS

A1.3 THIRD FLOOR DEMOLITION AND NEW WORK PLANS

A1.4 ROOF DEMOLITION AND WORK PLANS

A2.0 BSMT & 1ST FLR REFLECTED CLG PLANS AND DETAILS

A2.1 2ND & 3RD FLR REFLECTED CLG PLANS

A3.0 BUILDING ELEVATIONS

A4.0 BUILDING SECTIONS AND ROOF DETAILS

A4.1 BUILDING SECTIONS

A5.0 STAIR SECTIONS AND DETAILS

A5.1 MISCELLANEOUS STAIR DETAILS

A5.2 MISCELLANEOUS DETAILS

A6.0 ENLARGED PLANS AND INTERIOR ELEVATIONS

A6.1 ENLARGED PLANS AND INTERIOR ELEVATIONS

A7.0 DOOR SCHEDULE, DETAILS AND STOREFRONT ELEVATIONS

A8.0 RM FINISH PLAN, SCHEDULE & (N.I.C.) FURNITURE LAYOUT

A8.1 ROOM FINISH PLANS & (N.I.C. FURNITURE LAYOUT)

A8.2 Basement - FINISHES

A8.3 1st FLOOR - FINISHES

A8.4 2nd Floor - FINISHES

A8.5 3rd Floor - FINISHES

PD1.0 PLUMBING - DEMOLITION - BASEMENT AND 1ST FLOORS

PD1.1 PLUMBING - DEMOLITION - 2ND AND 3RD FLOORS

PL1.0 PLUMBING - NEW - BASEMENT FLOOR

PL1.1 PLUMBING - NEW - 1ST FLOOR

PL1.2 PLUMBING - NEW - 2ND FLOOR

PL1.3 PLUMBING - NEW - 3RD FLOOR

PL1.4 PLUMBING - NEW - ROOF

PL1.5 PLUMBING DETAILS AND SCHEDULE

PL1.6 PLUMBING ISOMETRIC

FP1.0 FIRE PROTECTION - BASEMENT FLOOR AND 1ST FLOOR PLANS

FP1.1 FIRE PROTECTION - 2ND AND 3RD FLOOR PLANS

FP2.0 FIRE PROTECTION LEGEND AND DETAILS

HV1.0 HVAC DUCTWORK - NEW AND DEMOLITION - BASEMENT

HV1.1 HVAC DUCTWORK - NEW AND DEMOLITION - 1ST FLOOR

HV1.2 HVAC DUCTWORK - NEW AND DEMOLITION - 2ND FLOOR

HV1.3 HVAC DUCTWORK - NEW AND DEMOLITION - 3RD FLOOR

HV1.4 HVAC DUCTWORK - NEW AND DEMOLITION - ROOF

HV2.0 H.V.A.C. DETAILS

HV2.1 H.V.A.C. PIPING DIAGRAMS

HV3.0 H.V.A.C. SCHEDULES

HV3.1 H.V.A.C. SCHEDULES

E0.00 ELECTRICAL LEGEND

EP1.0 ELECTRIC POWER - NEW AND DEMOLITION - BASEMENT FLOOR

EP1.1 ELECTRIC POWER - NEW AND DEMOLITION - 1ST FLOOR

EP1.2 ELECTRIC POWER - NEW AND DEMOLITION - 2ND FLOOR

EP1.3 ELECTRIC POWER - NEW AND DEMOLITION - 3RD FLOOR

EP1.4 ELECTRIC POWER - NEW AND DEMOLITION - ROOF

EP2.00 ELECTRICAL DETAILS

EP3.00 ELECTRICAL SINGLE LINE DIAGRAM

EP4.0 ELECTRIC PANEL SCHEDULES

EL1.0 ELECTRIC LIGHTING - NEW - BASEMENT AND FIRST FLOORS

EL1.1 ELECTRIC LIGHTING - NEW - 2ND AND 3RD FLOORS

EL2.0 ELECTRIC LUMINAIRE SCHEDULE

CT.00 COMMUNICATION LEGEND & NOTES

CT1.0 COMMUNICATION TECHNOLOGY - NEW - BASEMENT AND FIRST FLOORS

CT1.2 COMMUNICATION TECHNOLOGY - NEW - 2ND AND 3RD FLOORS

CT4.1 COMMUNICATION DETAILS

CT5.1 COMMUNICATION DETAILS

CT5.2 COMMUNICATION DETAILS

CT6.5 COMMUNICATION DETAILS

STRUCTURAL

BROWN + KUBICAN, PSC

2224 YOUNG DRIVE

LEXINGTON, KY 40505

859-543-0933

MECHANICAL/ELECTRICAL

KOHRS LONNEMANN HEIL

ENGINEERS, PSC

1538 ALEXANDRIA PIKE, SUITE 11

FT. THOMAS, KY 41075

859-442-8050

PROJECT SITE:

438-440 SCOTT BLVD.

COVINGTON, KY 41011

PROJECT SITE:

438-440 SCOTT BLVD.

COVINGTON, KY 41011

ACCOUNT NO:

AS-BUILT

12-18-15 rhinson Snapshot

File details come from the government source that posted it. Updated .