41-42 - PL1.6.pdf
PDF 527 KB Posted
- Solicitation number
- RFP260305
- Issued by
- Hart County, Kentucky
About this file
This is a plumbing isometric drawing prepared by the Division of Engineering under the Commonwealth of Kentucky's Finance and Administration Cabinet, Department for Facilities & Support Services, in conjunction with Kohrs Lonnemann Heil Engineers (KLH), Professional Services for the Gateway Urban Campus located at 438-440 Scott Street, Covington, Kentucky 41011. The drawing depicts detailed plumbing specifications for a Classroom Center facility, specifically illustrating loop vent piping details and sanitary waste system configurations. The technical specifications include a 2-inch vent pipe positioned as high as possible under the fixture with drainage through a floor pipe sleeve, a 2-inch sanitary line under the floor utilizing a combination "Y" and 1/8 bend long turn fitting, and a slope long sweep configuration scaled to plan. The drawing is identified as sheet PL1.6 and was created on 12/18/15, with the project number KLH PRO. NO. 11369.04 and drawing number 470-C5N5-NC11-01.
The document represents technical design specifications for mechanical/plumbing systems at a surplus real property location designated for economic development purposes. This isometric plumbing detail drawing serves as part of the professional services and engineering documentation package for the Gateway Urban Campus renovation or development project, establishing the required plumbing infrastructure standards and installation methodologies to be followed during construction. No pricing, bidding information, response dates, or contractual terms are contained within this technical specification document.
View the file
Other files
Show 40 more
Latest 50 of 80 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2" VENT PIPE TO BE AS HIGH AS
POSSIBLE UNDER FIXTURE, THEN
DOWN FLOOR
PIPE SLEEVE THRU
FLOOR, SEE SPECS.
2" VENT UNDER FLOOR,
SEE PLAN FOR LOCATION
WASTE OUTLET FROM FIXTURE
2" SANITARY UNDER
FLOOR
COMBINATION "Y" AND 1/8
BEND LONG TURN
2"
FLOOR
2"
SLOPE
LONG SWEEP
SLOPE
SCALE:
LOOP VENT PIPING DETAIL
NONE
221313.00-18
CLEANOUT
DATE
DATE
ENGINEERING
DIVISION OF
AGENCY
AUTHORIZED AGENT
DIV. OF ENGR.
REVIEWED
ENGR. ACCT NO.
DRAWING NO.
DATE
A&E FILE NO.
CHECKED BY
SHEET DRAWN BY
RECORD DATE
DATEREVISIONS
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES & SUPPORT SERVICES
DIVISION OF ENGINEERING
FRANKFORT, KENTUCKY
WWW.KLHENGRS.COM
ENGINEERS, PSC
MECHANICAL/ELECTRICAL ENGINEERS
KOHRS LONNEMANN HEIL
LEXINGTON, KENTUCKY
COLUMBUS, OHIO
DAYTON, OHIO
NEW YORK, NEW YORK
1538 ALEXANDRIA PIKE, SUITE
11 FT. THOMAS, KENTUCKY
41075 800-354-9783
859-442-8050
859-442-8058 FAX
KLH PRO. NO.
11369.04
470-C5N5-NC11-01
GATEWAY URBAN CAMPUS
438-440 Scott St., Covington, KY 41011
12/18/15
201114.02
PROFESSIONAL SERVICES CLASSROOM CENTER
PL1.6
PLUMBING ISOMETRIC
File details come from the government source that posted it. Updated .