S02 Fire Alarm Panel.pdf

PDF 1 MB Posted

Attached to
CAMP NELSON NATIONAL CEMETERY, KY 833CM3030 – CORRECT FCA DEFICIENCIES
Solicitation number
36C78626R0058
Issued by

About this file

This is a product label and documentation page for a FireWarden-100-2/E/C Addressable Fire Control Panel designed for commercial protected premises. The FireWarden-100-2 unit is a commercial fire alarm system that must be installed, maintained, and operated according to the manufacturer's specifications and applicable standards including Canadian ICE-003 and NMB-003 compliance for digital apparatus. The system features Type AM (Attendant Monitored) signaling with 24 VDC standby lead acid battery capability and includes addressable detectors with a maximum of 89 detectors supported.

The control panel has an FCC registration number US:IW6AL00B9200UD with 0dB Ringer Equivalence and complies with Part 68 FCC Rules. The emergency contact number is 1-800-877-3624. The unit is assigned ACCT# HA2146 with Passcode 146. Critical operational notes include a 13-second delay for alarm activation after smoke detector initiation, and the system supports multiple power sources with power-limited initiating device circuits and communications loop meeting NFPA 72 Style 4, 6, or 7 requirements. The product includes a 36-month limited warranty covering fire protection capabilities. Service and maintenance warnings specify that only authorized manufacturers, distributors, and service representatives may repair or service the unit, and all trouble conditions must be immediately addressed to maintain proper system operation.

View the file

Other files

File Type Posted
S06_36C78626R0058 Amend. 0003.pdf PDF
S02 Amendement 36C78626R0058 0002.pdf PDF
S02 12 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_addendum01.pdf PDF
S02 Liquidated Damages 833CM3030_CNNC FCA Corrections CONS.pdf PDF
S02 amendment 2.pdf PDF
S02 Amendment 36C78626R0058 0001.pdf PDF
S02 11 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 2_05212026 1.pdf PDF
S09 09 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 05 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 01 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 Camp Nelson Sol 36C78626R0058 draft 9-14-2026.pdf PDF
S02_Attachment - Davis-Bacon Act Poster.pdf PDF
S02_Attachment - Past Performance Questionnaire.docx DOCX document
S02_Price Proposal Breakdown.docx DOCX document
S02_Attachment - Project Sample Template.docx DOCX document
S02 10 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
P07 Jessamine Camp Nelson Building.pdf PDF
S02 08 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 06 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 02 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 07 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 03 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 04 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1 (1).pdf PDF
S02 833CM3030_CNNC FCA Corrections_CONS_BD SPECIFICATIONS.pdf PDF
S02_Attachment - Standard Form 1413.pdf PDF
S02_Attachment - DOL Payroll Form.pdf PDF
P07 Jessamine Camp Nelson Highway.pdf PDF
P07 Jessamine Camp Nelson Heavy.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

File details come from the government source that posted it. Updated .