This document is a product specification sheet for the SafeSite Dispensing System Controller (DSC), a fuel system control solution manufactured by Core Engineered Solutions, Inc.

The SafeSite DSC is a pre-engineered power distribution and control system designed to serve as a single-point power connection that integrates all components of a fuel dispensing system. The system can be installed indoors or adjacent to tank and dispensing areas at distances between 20 and 100 feet. Key standard features include a single input power connection with dedicated outputs to pumps, dispensers, anti-syphon solenoids, fuel management systems (key/card readers), tank gauging/monitoring equipment, fire suppression systems, and remote emergency stop controls. The control panel incorporates integrated power distribution and motor controls, a panel-mounted emergency stop controller, and a NEMA 4X stainless steel enclosure suitable for outdoor and high-corrosion environments. The emergency stop mechanism breaks both power and neutral conductors in compliance with NEC code, distinguishing it from competing systems. Each DSC system is delivered with site-specific conduit layout schematics and point-to-point wiring diagrams customized for industry-standard equipment including Gasboy, Wayne, Great Plains, Red Jacket, FE Petro, VeederRoot, Pneumercator, Franklin, and Omntec components.

The system specifications include eight dedicated circuits: dispenser control and anti-siphon, fuel management, tank level gauge, fire suppression/emergency stop controls, and motor starter control with overload protection (maximum 1-1/2 hp). Circuit disconnects must comply with 2011 NEC 514.11(A) standards, with attended self-service facilities requiring emergency controls within 100 feet of dispensers and unattended facilities requiring controls between 20 and 100 feet, with additional controls on each dispenser group. Optional equipment available includes remote annunciators and custom panel configurations. Core Engineered Solutions, Inc. provides the complete system and can be contacted at 518-635-4343 (NY office) or 800-628-5502 (headquarters).

View the file

Other files

File Type Posted
Amendment 4-833CM3030 - CD1 - Historic Hardware.pdf PDF
Amendment 4-833CM3030 - BID - HA-001 from 20260422 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - CU-105 from 20260107 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - 23 11 13 Fuel Storage Tanks.pdf PDF
Amendment 4-833CM3030 - BID - 037 - CU-105 UTILITY PLAN (R2).pdf PDF
Amendment 4-833CM3030 - BID - 26 29 23 Engine Control and Monitoring.pdf PDF
Amendment 4-833CM3030 - BID - 028 - CP-105 PAVING PLAN (R2).pdf PDF
Amendment 4-833CM3030 - BID - SN-104 105 and X-series from 20260107 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - Historic Pages from 20260422 - 833CM3030 - BID - SET A-004 005 132 133 154 155.pdf PDF
Amendment 4-ConVault Specification with UL 752 Level 8.pdf PDF
Amendment 4-Convault Storage tank 500 GL-telford.pdf PDF
Amendment 4-Convault Brochure 2019 (003).pdf PDF
Amendment 4-833CM3030 - BID - 020 - CG-201 POND AND CRYPT FIELD SECTIONS (R1).pdf PDF
Amendment 4-AE-113 from 20260422 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-AE-113 833CM3030 - BID - SET.pdf PDF
S02 36C78626R0058 Amendment 0004.docx DOCX document
Amendment 4-833CM3030 - CD1 - Historic Preservation.pdf PDF
Amendment 4-SED FCA - 04212022_Camp Nelson.pdf PDF
Amendment 4-833CM3030 - BID - AE-110 from 20260422 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - 328400 Plant Irrigation_10-31-24.pdf PDF
Amendment 4- 36C78626R0058 FuelForce 814 Advanced Fuel Controller Brochure.pdf PDF
Amendment 4-240524-Camp Nelson National Cemetery - KY- SUE Field Report Deliverable.pdf PDF
Amendment 4-833CM3030 - BID - AE-150 from 20260422 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - 07 42 43 Plastic Panel.pdf PDF
Amendment 4-833CM3030 - BID- EQUIPMENT STORAGE GARAGE-AE-141.pdf PDF
Amendment 4-GI-104 from 20260107 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - 231123 NatGas.pdf PDF
Amendment 4- 833CM3030 - BID - 072727 - BARRIER VAPOR.pdf PDF
Amendment 4-3189 ECS Geotechnical Engineering Report - Expansion Area.pdf PDF
Amendment 4-833CM3030 - BID - 329000 Planting.pdf PDF
Amendment 4-3189 ECS Geotechnical Engineering Report - Camp Nelson Cemetery.pdf PDF
Amendment 4-833CM3030 - BID - 050 - S-101 STRUCTURAL PLAN (R2).pdf PDF
Amendment 4-Lightning Protection Asmnt Report_Camps Nelson Cemetery.pdf PDF
Amendment 4-833CM3030 - BID - CD-102 from 20260107 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-AD-150 from 20260107 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - 33 56 10 Temporary Fuel Storage Tanks.pdf PDF
Amendment 4-833CM3030 - BID - 052 - S-202 MATERIALS STORAGE BLDG. FRAMING (R2).pdf PDF
Amendment 4-3189 ECS Geotechnical Engineering Report - Maintenance Area.pdf PDF
S06_36C78626R0058 Amend. 0003.pdf PDF
S02 Amendement 36C78626R0058 0002.pdf PDF
S02 amendment 2.pdf PDF
S02 Fire Alarm Panel.pdf PDF
S02 Liquidated Damages 833CM3030_CNNC FCA Corrections CONS.pdf PDF
S02 12 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_addendum01.pdf PDF
S02 Amendment 36C78626R0058 0001.pdf PDF
P07 Jessamine Camp Nelson Building.pdf PDF
S02_Price Proposal Breakdown.docx DOCX document
S02_Attachment - Past Performance Questionnaire.docx DOCX document
P07 Jessamine Camp Nelson Highway.pdf PDF
S02_Attachment - DOL Payroll Form.pdf PDF
Show 40 more

Latest 50 of 67 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Core Engineered Solutions 800.628.5502 info@core-es.com www.core-es.com

Standard Features

• Single input power connection with dedicated outputs to pumps, dispensers, anti-syphon solenoid, fuel management (key/card), tank gauging/ monitoring, fire suppression, emergency stop (remote).

• Integrated power distribution and motor controls.

• Emergency stop breaks both power AND neutral.

• Panel mounted emergency stop controller.

• Monitors/verifies integrity of emergency control circuit.

• NEMA 4X enclosure (stainless steel available).

• Site specific conduit layout schematic included.

• Point-to-point wiring diagram specific to all industry pumps, dispensers, and other system components, including Gasboy, Wayne, Great Plains, Red Jacket, FE Petro, Veeder- Root, Pneumercator, Franklin, and Omntec.

The SafeSite Dispensing System Controller (DSC) is designed to serve as a single point power connection and control system that integrates all components of a fuel dispensing system.

The SafeSite DSC is pre-engineered and can be installed indoors or adjacent to your tank and dispensing area (min. 20 – max. 100 feet).

Controller logic manages the emergency stop on/off for each device, as well as the integrity of the emergency control circuit.

Unlike other control systems, the emergency stop breaks both power and neutral (per NEC code). The DSC is delivered with your tank along with a site schematic showing conduit layout and a specific point-to-point wiring diagram for each equipment component in the system. This helps simplify installation and minimize site expenses.

Dispensing System Controllero oSafeSite fuel system controls

Core Engineered Solutions 800.628.5502 info@core-es.com www.core-es.com

General: The Safesite DSC Dispensing System Power Distribution and Controls. The DSC is a single source power connection with dedicated power/control outputs to pumps, dispensers, control valves, fuel management system, tank gauging and monitoring, fire suppression, and other ancillary devices. The DSC includes a monitored emergency stop. Each system comes with a specific tank, equipment, and conduit layout with point to point wiring diagrams.

The system in its entirety shall be provided by Core Engineered Solutions, Inc. 518-635-4343 (NY) or 800-628- 5502 (Headquarters).

The Safesite Dispensing System Power Distribution and Controls shall integrate the following functions into one system:

A. Control Panel Specifications

1. Single input power connection with main power disconnects.

2. NEMA 4X enclosure suitable for outdoor and high corrosion areas.

3. Panel mounted emergency stop control button.

4. Dedicated dispenser control and anti-siphon circuit.

5. Dedicated fuel management control circuit.

6. Dedicated tank level gauge circuit.

7. Dedicated fire suppression / emergency stop controls circuit.

8. Dedicated motor starter control and overload protection circuit (1-1/2 hp max).

9. Dedicated dry output for remote emergency stop controls circuit.

B. Circuit Disconnects

1. General. Each circuit leading to or through dispensing equipment, including all associated power, and equipment for remote pumping systems, shall be provided with a clearly identified and readily accessi-ble switch or other approved means, located remote from the dispensing devices, to disconnect simul-taneously from the source of supply, all conductors of the circuits, including the grounded conductor, if any. Single pole breakers utilizing handle ties shall not be permitted.

2. Attended Self-Service Motor Fuel Dispensing Facilities. Emergency controls as specified in 2011 NEC 514.11(A) shall be installed at a location acceptable to the authority having jurisdiction, but controls shall not be more than 30 m (100 ft) from dispensers.

3. Unattended Self-Service Motor Fuel Dispensing Facilities. Emergency controls as specified in 2011 NEC 514.11(A) shall be installed at a location acceptable to the authority having jurisdiction, but the control shall be more than 6 m (20 ft) but less than 30 m (100 ft) from the dispensers. Additional emergency controls shall be installed on each group of dispensers or the outdoor equipment used to control the dis-pensers. Emergency controls shall shut off all power to all dispensing equipment at the station. Controls shall be manually reset only in a manner approved by the authority having jurisdiction.

C. Optional Equipment

1. Where indicated on the drawings for the DSC, optional additional equipment shall be provided for:

a. Remote Annunciator

b. Stainless steel enclosures

c. Custom panels

DSC Specificationso oSafeSite fuel system controls

File details come from the government source that posted it. Updated .