S02 12 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_addendum01.pdf

PDF 5 MB Posted

Attached to
CAMP NELSON NATIONAL CEMETERY, KY 833CM3030 – CORRECT FCA DEFICIENCIES
Solicitation number
36C78626R0058
Issued by

About this file

This is a bid set of design and construction documents for corrective work at Camp Nelson National Cemetery in Harrodsburg, Kentucky (Project No. 833CM3030). The project, prepared by Astute Engineering, PLLC and Walker Federal Services, LLC, is dated January 7, 2026, and involves correcting FCA (Facility Condition Assessment) deficiencies across multiple building systems.

The documents include comprehensive electrical, wayfinding, and architectural plans for four primary buildings: a Public Restroom/Wash Bay Building, a Historic Maintenance Building, and an Equipment Storage Building. Electrical work encompasses new power panels, receptacles, lighting fixtures with occupancy sensors, relocated equipment connections, and dedicated circuits for IT infrastructure and mechanical equipment. Wayfinding improvements involve installation of new directional and informational signage throughout the cemetery grounds, including exterior post-and-panel signs, wall-mounted signs with tactile and braille components for ADA compliance, interior restroom signage, and employee locker room identification. Specific sign types detailed include steel posts with precast concrete collars (XN1, XN2, XW1-XW5), aluminum slide-series interior signs (XI3, XI4), and bronze military service seals (XI1) to be installed in the committal shelter. The project includes demolition of existing signage and replacement with ADA-compliant materials using Helvetica fonts and Matthews Paint finishes. All work is formatted as a complete bid set with general notes, legends, specifications cross-references, and detailed installation requirements. The National Cemetery Administration is the contracting agency.

View the file

Other files

File Type Posted
S06_36C78626R0058 Amend. 0003.pdf PDF
S02 Amendement 36C78626R0058 0002.pdf PDF
S02 amendment 2.pdf PDF
S02 Fire Alarm Panel.pdf PDF
S02 Liquidated Damages 833CM3030_CNNC FCA Corrections CONS.pdf PDF
S02 Amendment 36C78626R0058 0001.pdf PDF
P07 Jessamine Camp Nelson Building.pdf PDF
S02_Price Proposal Breakdown.docx DOCX document
S02_Attachment - Past Performance Questionnaire.docx DOCX document
P07 Jessamine Camp Nelson Highway.pdf PDF
S02_Attachment - DOL Payroll Form.pdf PDF
S02 833CM3030_CNNC FCA Corrections_CONS_BD SPECIFICATIONS.pdf PDF
S02 08 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 10 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 04 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1 (1).pdf PDF
S02_Attachment - Standard Form 1413.pdf PDF
S02 02 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 07 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 03 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 06 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
P07 Jessamine Camp Nelson Heavy.pdf PDF
S02_Attachment - Davis-Bacon Act Poster.pdf PDF
S09 09 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 11 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 2_05212026 1.pdf PDF
S02 Camp Nelson Sol 36C78626R0058 draft 9-14-2026.pdf PDF
S02 05 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 01 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02_Attachment - Project Sample Template.docx DOCX document
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CG-1

CG-1

1 2 3 4 5

A

B

D

F

C

CG-1

CG-1

CG-1 CG-1

FE

FE

FE

CG-1

B.1

ELECTRICAL POWER PLAN - EXISTING AND NEW WORK1 SCALE : 1/4" = 1'-0"

E E

E

HAND

DRYER

HAND

DRYER

Wp

Wp

Wp

WpWp

Wp

Wp

Wp

Wp

Wp

Wp

Wp

Wp

RE

RE

RE

E E

E

E

E

E

E

E

RE

E E

E

E

E

E

E

E

E

E

E

E

E

TV/+60" AFF

RE

RE

RE RE

RE RE

RE

E

MULTI PURPOSE

A-100

PUBLIC

MALE

A-103

UTILITIES

A-102

IT ROOM

A-101

PUBLIC

FEMALE

A-104

WASH BAY

B-100

STAFF TOILET

A-106

VESTIBULE

BW-117M

EXISTING

PANEL FACP-1

E

RTU-1

3-TON

B-14,16

E E

WH-1

NEW GWH-1

RE

SS

RERELOCATED CP-1

EXISTING GRAVESITE

LOCATOR

RELOCATED

PNL E

RELOCATED

PNL B

J

B-29

EX CONCRETE PAD

HP-1

B-2,4

60A/240V/2P/

NEMA 3R DSW RTH-1

RTH-2

B-23

B-27

SM

SM

B-25

CORRIDOR

A-105

EXISTING

TELECOMMUNICATION

TERMINAL BOARD

(FIRE RATED PLYWOOD)

(TYP.)

NEW WALL

MOUNTED IT RACK

DH-1 DH-2

B-30

B-28

HAND

DRYER

60A/240V/2P/

NEMA 3R DSW

B-2

EXISTING BONDING

BUS BAR

+42"

+42"

B-10,12

30A/240V/2P

NEMA 1 DSW

B-10,12

30A/240V/2P

NEMA 1 DSW

E +42"

E E E +42" +42"+42"

+42" B-10,12

30A/240V/2P/

NEMA 1 DSW

ERAD-3

ERAD-4

30A/240V/2P/

NEMA 1 DSW

B-10,12

IT ROOM

1 2 3 4 5

ELECTRICAL LIGHTING PLAN - EXISTING AND NEW WORK2 SCALE : 1/4" = 1'-0"

PC

TC

W W S S

S S

S

S

S

S

E

RE

E E EEE

E E

E E

RE

E E

RE RE

E

RE

RE

E

E

E E

RE

E

E

E E E E E E

E

E

E E E E EE

E

E

E E

E

E

E E

C2

D

RE

SD

RE

E

SS

RERE

E

A2

A1 A13 3

D D

D D

SOS

C2

E

MULTI PURPOSE

A-100

PUBLIC

MALE

A-103

UTILITIES

A-102

A-101

PUBLIC

FEMALE

A-104

CORRIDOR

A-105

WASH BAY

B-100

STAFF

TOILET

A-106

VESTIBULE

BW-117M

C2

C2

C2

C2

Z

E

OS RE

OS

OS

RE

OS

C2

OS

C2

EF-1

EF-2

RE

D

C2

D

D D

S

E

OS

Z

Z

Z

Z Z

PUBLIC RESTROOM / WASH BAY

BUILDING - ELECTRICAL PLANS -

EXISTING AND NEW WORK

EN-101

NOT TO SCALE

KEY PLAN

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

833CM3030

UB,HU SV

JANUARY 7, 2026

Bid Set

ASTUTE ENGINEERING, PLLC.

1945 OLD GALLOWS ROAD, STE 201, VIENNA, VA 22182

PH: (202) 400-2004 I WWW.ASTUTENG.COM

STUTE

ENGINEERING

Creative Designs | Intelligent Solutions

A

RELOCATED EXISTING ELECTRICAL PANEL. FOR MORE DETAILS,

SEE ELECTRICAL SITE PLAN, DRAWING ES-200.

RELOCATED RECEPTACLE, INCLUDING WIRING AND CONDUIT.

CONNECT TO THE EXISTING CIRCUIT BREAKER FEEDING THE

EXISTING RECEPTACLE PRIOR TO RELOCATION.

PROVIDE NEW RECEPTACLE INCLUDING WIRING AND CONDUIT

AS SHOWN.

RELOCATED LIGHT FIXTURE, SWITCH AND OCCUPANCY SENSOR

INCLUDING WIRING AND CONDUIT. CONNECT TO THE EXISTING

LIGHTING POWER CIRCUIT, FEEDING THE EXISTING LIGHTS

PRIOR TO RELOCATION.

PROVIDE NEW LIGHT FIXTURE AND SWITCH. CONNECT TO THE

NEAREST LIGHTING CIRCUIT.

PROVIDE NEW ELECTRICAL CONNECTION TO THE NEW

MECHANICAL EQUIPMENT INCLUDING WIRING AND CONDUIT.

FOR MORE DETAIL, SEE MECHANICAL DRAWING MN-101.

PROVIDE NEW ELECTRICAL CONNECTION TO THE NEW

WATER HEATER INCLUDING WIRING AND CONDUIT. CONNECT

TO THE EXISTING POWER CIRCUIT, FEEDING THE EXISTING

WATER HEATER PRIOR TO DEMOLITION. FOR MORE DETAIL, SEE

PLUMBING DRAWING PN-101.

PROVIDE NEW DEDICATED (2) 30 AMP 120/1P ELECTRICAL

POWER CIRCUIT, WITH A (2) NEMA 15-30 RECEPTACLES

INCLUDING WIRING AND CONDUIT. MOUNT RECEPTACLE ON

NEW IT RACK. ELECTRICAL POWER CABLES SHALL BE FED

THROUGH THE TOP OF THE RACK TO ALLOW MOVEMENT OF

THE RACKS.

PROVIDE NEW LIGHT FIXTURE AND SWITCH. CONNECT TO THE

NEAREST EMERGENCY LIGHTING POWER CIRCUIT.

0 2' 4' 8' 12'

SCALE : 1/4" = 1'-0"

CNNEW3

GENERAL NOTES

1. FOR ELECTRICAL SYMBOLS, ABBREVIATION AND GENERAL

NOTES, SEE DRAWING E-001.

2. FOR PUBLIC RESTROOM / WASHBAY BUILDING ELECTRICAL

PLANS - EXISTING AND DEMOLITION WORK, SEE DRAWING

ED-101.

3. FOR ELECTRICAL POWER RISER DIAGRAMS, SEE DRAWING E-501.

4. FOR ELECTRICAL SCHEDULES, SEE DRAWING E-601 AND E-602.

5. OCCUPANCY SENSORS SHALL TURN OFF THE LIGHTINGS WITHIN

20 MINUTES OF OCCUPANTS LEAVING THE STACK AREA.

LEGENDS

E - EXISTING TO REMAIN

RE - RELOCATED

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

04 04

05 (TYP.)

02(TYP.)

(TYP.)

EXISTING RADIANT

TUBE HEATER

KEY NOTES

(TYP.)

AREA OF WORK

ELECTRICAL POWER PLAN - EXISTING AND NEW WORK1 SCALE : 1/4" = 1'-0"

SERVICE BAY

B1

OFFICE

B3

WP

RELOCATED

BASEBOARD

HEATER

RELOCATED

BASEBOARD

HEATER

NEW AC-1

3-TON

NEW 30A/240V/2P/

NEMA 3R DSW

NEW PANEL A

A-24,26

RE

RE

A-13

A-15

A-17

4" EQUIPMENT PAD

A-10

A-16 WP

EXISTING

EXHAUST

FAN

LOUNGE

B2

MEN'S LOCKER RM

B2

WOMEN'S LOCKER RM

B2

MEN

B6

WOMEN

B7

A-2 A-1,3

E

E

A-6,8

IT

RACK

TELECOMMUNICATION

BONDING BUS BAR

PLYWOOD BACKBORD

A-32

A-4 A-11

+42"

+42"

+42"

ELECTRICAL LIGHTING PLAN - EXISTING AND NEW WORK2 SCALE : 1/4" = 1'-0"

SSS S

S

S O S

F

F

A2

A2E

A2E

A2

F F

F

A2

A2

A2

F

S O S

S

A2E

C1E C1

Z

OS

OS

OS

A2E

C1E C1

A2A2E

SERVICE BAY

B1

OFFICE

B3

MEN'S LOCKER RM

B2

MEN

B6

WOMEN

B7

WOMEN'S LOCKER RM

B2

OS

A-9

A-23

LOUNGE

B2

S

TO ATTIC

LIGHTING

A2

EF-3

ELECTRICAL LIGHTING PLAN - ATTIC2 SCALE : 1/4" = 1'-0"

B B

DOWN

SBBB B B B

BBBB

B

TO THE

SWITCH

BELOW

A-31

B

DOWN

ELECTRICAL POWER PLAN - ATTIC1 SCALE : 1/4" = 1'-0"

SM

A-20 60A/240V/2P/

NEMA 1 DSW

A-5,7

NEW EWH-1

A-34

KEY PLAN

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

833CM3030

UB,HU SV

JANUARY 7, 2026

Bid Set

ASTUTE ENGINEERING, PLLC.

1945 OLD GALLOWS ROAD, STE 201, VIENNA, VA 22182

PH: (202) 400-2004 I WWW.ASTUTENG.COM

STUTE

ENGINEERING

Creative Designs | Intelligent Solutions

A

HISTORIC MAINTENANCE

BUILDING ELECTRICAL PLANS -

-EXISTING AND NEW WORK

EN-102

PROVIDE NEW ELECTRICAL PANEL INCLUDING WIRING AND

CONDUIT. FOR MORE DETAILS, SEE ELECTRICAL ONE LINE

DIAGRAM, SEE DRAWING E-501.

PROVIDE NEW RECEPTACLE INCLUDING WIRING AND CONDUIT.

PROVIDE NEW LIGHTING FIXTURE, SWITCH AND OCCUPANCY

SENSOR INCLUDING WIRING AND CONDUIT.

PROVIDE NEW OUTDOOR LIGHTING FIXTURE WITH BUILT-IN

PHOTOCELL FEATURE. MOUNT NEW LIGHTING FIXTURE AT

SIMILAR HEIGHT AS EXISTING LIGHTING FIXTURE. PROVIDE

NECESSARY WIRING AND CONNECTIONS WITH LIGHT SWITCH

AND FIXTURES. THE INTENT IS TO KEEP THE LIGHT SWITCH

ALWAYS 'ON' TO ALLOW THE SERIES CONNECTED PHOTOCELL

TO PERFORM SWITCHING ACCORDING TO AMBIENT LIGHT.

LIGHT SWITCH TO BE USED TO OVERRIDE THE PHOTOCELL,

WHEN REQUIRED.

CONNECT EXIT AND EMERGENCY LIGHTING FIXTURE AHEAD OF

THE SWITCH.

PROVIDE NEW ELECTRICAL CONNECTIONS TO THE NEW

MECHANICAL AND PLUMBING EQUIPMENT INCLUDING WIRING

AND CONDUIT. FOR MORE DETAIL, SEE MECHANICAL AND

PLUMBINGS DRAWING.

PROVIDE NEW ELECTRICAL CONNECTION TO THE RELOCATED

EQUIPMENT INCLUDING WIRING AND CONDUIT.

PROVIDE NEW DEDICATED (2) 30 AMP 120/1P ELECTRICAL

POWER CIRCUIT, WITH A (2) NEMA 15-30 RECEPTACLES

INCLUDING WIRING AND CONDUIT. MOUNT RECEPTACLE ON

NEW IT RACK. ELECTRICAL POWER CABLES SHALL BE FED

THROUGH THE TOP OF THE RACK TO ALLOW MOVEMENT OF

THE RACKS.

EXISTING ATTIC RECEPTACLES ARE NOT SHOWN. REPLACE

EXISTING ALL ATTIC RECEPTACLES WITH NEW INCLUDING NEW

WIRING AND NEW CONDUIT.

0 2' 4' 8' 12'

SCALE : 1/4" = 1'-0"

GENERAL NOTES

LEGENDS

E - EXISTING TO REMAIN

RE - RELOCATED

1. FOR ELECTRICAL SYMBOLS, ABBREVIATION AND GENERAL

NOTES, SEE DRAWING E-001.

2. FOR HISTORIC MAINTENANCE BUILDING ELECTRICAL PLANS -

EXISTING AND DEMOLITION WORK, SEE DRAWING ED-102.

3. FOR ELECTRICAL POWER RISER DIAGRAMS, SEE DRAWING E-501.

4. FOR ELECTRICAL SCHEDULES, SEE DRAWING E-601 AND E-602.

5. OCCUPANCY SENSORS SHALL TURN OFF THE LIGHTINGS WITHIN

20 MINUTES OF OCCUPANTS LEAVING THE STACK AREA.

(TYP.)

(TYP.)

(TYP.)

04 (TYP.)

(TYP.)

(TYP.)

05 05

(TYP.)

(TYP.)

03(TYP.)

02 (TYP.)

02 (TYP.)

(TYP.)

02(TYP.)

KEY NOTES

(TYP.)

(TYP.)

(TYP.)

AREA OF WORK

ELECTRICAL LIGHTING PLAN - EXISTING AND NEW WORK2 SCALE : 1/4" = 1'-0"

AT MEZZAINE

(SURFACE MOUNT)

UNDER MEZZAINE

(SURFACE MOUNT)

SSS

A3 A3

A3EA3

A1E A1

A1

F

F F

F

OS

B-16

B-10

EQUIPMENT

STORAGE

BUILDING

ELECTRICAL POWER PLAN - EXISTING AND NEW WORK1 SCALE : 1/4" = 1'-0"

NEW PANEL B

E

B-17

B-15

B-11 B-13

EQUIPMENT

STORAGE

BUILDING

NEW PLUG

STRIP WITH (8)

RECEPTACLES

E E

EXISTING UNIT

HEATER

EXISTING UNIT

HEATER

EE

EXISTING

COMPRESSOR

E

EQUIPMENT STORAGE

BUILDING ELECTRICAL PLANS -

EXISTING AND NEW WORK

EN-103

KEY PLAN

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

833CM3030

UB,HU SV

JANUARY 7, 2026

Bid Set

ASTUTE ENGINEERING, PLLC.

1945 OLD GALLOWS ROAD, STE 201, VIENNA, VA 22182

PH: (202) 400-2004 I WWW.ASTUTENG.COM

STUTE

ENGINEERING

Creative Designs | Intelligent Solutions

A

0 2' 4' 8' 12'

SCALE : 1/4" = 1'-0"

01 PROVIDE NEW RECEPTACLE INCLUDING WIRING AND

CONDUITS.

PROVIDE NEW LIGHTING FIXTURE, SWITCH AND OCCUPANCY

SENSOR INCLUDING WIRING AND CONDUIT.

PROVIDE NEW OUTDOOR LIGHTING FIXTURE WITH BUILT-IN

PHOTOCELL FEATURE. MOUNT NEW LIGHTING FIXTURE AT

SIMILAR HEIGHT AS EXISTING LIGHTING FIXTURE. PROVIDE

NECESSARY WIRING AND CONNECTIONS WITH LIGHT SWITCH

AND FIXTURES. THE INTENT IS TO KEEP THE LIGHT SWITCH

ALWAYS 'ON' TO ALLOW THE SERIES CONNECTED PHOTOCELL

TO PERFORM SWITCHING ACCORDING TO AMBIENT LIGHT.

LIGHT SWITCH TO BE USED TO OVERRIDE THE PHOTOCELL,

WHEN REQUIRED.

CONNECT EMERGENCY LIGHTING FIXTURE AHEAD OF THE

SWITCH.

PROVIDE NEW ELECTRICAL PANEL INCLUDING WIRING AND

CONDUIT. FOR MORE DETAILS, SEE ELECTRICAL ONE LINE

DIAGRAM, SEE DRAWING E-501.

CNNEW1

GENERAL NOTES

LEGENDS

E - EXISTING TO REMAIN

1. FOR ELECTRICAL SYMBOLS, ABBREVIATION AND GENERAL

NOTES, SEE DRAWING E-001.

2. FOR MAINTENANCE STORAGE BUILDING ELECTRICAL PLANS -

EXISTING AND DEMOLITION WORK, SEE DRAWING ED-103.

3. FOR ELECTRICAL POWER RISER DIAGRAMS, SEE DRAWING E-501.

4. FOR ELECTRICAL SCHEDULES, SEE DRAWING E-601 AND E-602.

5. OCCUPANCY SENSORS SHALL TURN OFF THE LIGHTINGS WITHIN

20 MINUTES OF OCCUPANTS LEAVING THE STACK AREA.

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

KEY NOTES

AREA OF WORK

LEGEND

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road F r e d e r i c k , M a r y l a n d 2 1 7 0 1

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

Campus Sign Location Plan

833CM3030

SS MK

X-101

January 7, 2026

166158

NOTES

NOT TO SCALE

KEY

Design Build Consortium | 39 Amber Forest, Hollywood Park, TX 78232 | 210-764-1045 | designbcllc.com

Wayfinding Associates | 2311 Bethel Church Road, Suite 101 Bethel Park, PA 15102 | 412.207.9115 | wfpros.com

IN

P

A R

T N

E R

S H

IP

W

IT

H

Wayfinding a s s o c i a t e sDesign Build Consortium, LLC

A Service-Disabled Veteran Owned Business

E

AB

VR

I

J

OP

Q

S

Z

Y

X

V

W

U

T

N

MC

R1

R2

H MA

MB

K

L

A

B

CWM

D

C

G

AA

BB

CC

EE

HH

JJ

FF

DD

COL2

COL1

CS2

CS1

FP

AA

GG2

GG1

F

Xi121 |A

XW11 A|B

XW3

XW3

XW3

XW1

XW1

XW1

XN1 XW1

XW1

XW5

2A 17

|A

A|

A

A|B

B|A

B|A

A|B B|A A

|B

|A

XW13

A|B

XW3

XW2

2B

|A

A|

Restroom Signs 9-14 on Page 2

XN218A A|B

Y

Y

Y

X

X

X

B|A

B|A

B|A

- SITE/BUILDING/ENTRY ID

- NOTICE/REGULATORY ID

- BURIAL SECTIONS

- MAIN DESTINATIONS

- WAYFINDING ID

AA - ASSEMBLY AREA

AB - ADMINISTRATION BUILDING

COL1 - COLUMBARIUM 1

COL2 - COLUMBARIUM 2

CS1 - COMMITTAL SHELTER 1

CS2 - COMMITTAL SHELTER 2

CWM - CIVIL WAR MEMORIAL

FP - FLAG POLE

VC - VISITOR RESTROOMS

Bid Set

C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road F r e d e r i c k , M a r y l a n d 2 1 7 0 1

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

Restroom / Employee Locker Room

833CM3030

SS MK

X-102

January 7, 2026

166159

NOTES

NOT TO SCALE

KEY

Design Build Consortium | 39 Amber Forest, Hollywood Park, TX 78232 | 210-764-1045 | designbcllc.com

Wayfinding Associates | 2311 Bethel Church Road, Suite 101 Bethel Park, PA 15102 | 412.207.9115 | wfpros.com

IN

P

A R

T N

E R

S H

IP

W

IT

H

Wayfinding a s s o c i a t e sDesign Build Consortium, LLC

A Service-Disabled Veteran Owned Business

Xi3

Xi3 Xi4

Xi4

Xi3

Xi3

YX B|A - SITE/BUILDING/ENTRY ID

Sign Location Plan

C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road F r e d e r i c k , M a r y l a n d 2 1 7 0 1

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

Sign Message Schedule

833CM3030

SS MK

X-103

January 7, 2026

166160

NOTES

KEY

Design Build Consortium | 39 Amber Forest, Hollywood Park, TX 78232 | 210-764-1045 | designbcllc.com

Wayfinding Associates | 2311 Bethel Church Road, Suite 101 Bethel Park, PA 15102 | 412.207.9115 | wfpros.com

IN

P

A R

T N

E R

S H

IP

W

IT

H

Wayfinding a s s o c i a t e sDesign Build Consortium, LLC

A Service-Disabled Veteran Owned Business

Version 3 R

E V

IS

IO

N

SIGN

NO.

S

IG

N T

Y P

E

C O

P Y

L

IN

E

SIGN

MESSAGE

M E

T H

O D

CLIENT

COMMENTS

START EXTERIOR

1 XW1 1a

2a

3a

4a

1b

2b

3b

4b

[left] Assembly Area

[left] Committal Shelter 1

[up] Committal Shelter 2

[up] Visitor Restrooms [isa]

[right] Assembly Area

[right] Committal Shelter 1

[up] Exit

X

2 XW3 1

[left] Committal Shelter 2

[left] Visitor Restrooms [isa]

[right] Exit

T Attach sign to fence using zip ties

2A XN1 Visitor info - see sign type X

2B XW2 1

Funeral

Staging

Area

X

3 XW1 1a

2a

3a

4a

1b

2b

3b

4b

[left] Committal Shelter 2

[up] Visitor Restrooms [isa]

[right] Committal Shelter 2

[up] Assembly Area

[up] Committal Shelter 1

[up] Exit

X

4 XW3 1

[left] Visitor Restrooms [isa]

[right] Assembly Area

[right] Committal Shelter 1

[right] Exit

T Attach the sign to the fence using zip ties.

Landscape removal by others needed to place sign on fence

Deleted

7/8/25

5 DELETE

Deleted

7/8/25

6 DELETE .

7 XW5 1a

2a

1b

2b

[up right]

Restrooms [isa] X

Deleted

7/8/25

8 DELETE

9 Xi3 1

[men isa]

MEN

A

10 Xi3 1

[women isa]

WOMEN

A

11 Xi4 1

FEMALE

EMPLOYEE

LOCKER ROOM

A

12 Xi3 1

[women isa]

WOMEN

A

13 Xi4 1

MALE

EMPLOYEE

LOCKER ROOM

A

14 Xi3 1

[men isa]

MEN

A

15 XW3 1

[up] Civil War

Memorial T Attach sign to fence using zip ties

Deleted

5/20/25

15A DELETE

Deleted

5/20/25

15B DELETE

Sign Message Schedule

Camp Nelson Exterior

Tuesday, July 8, 2025

R E

V

IS

IO

N

SIGN

NO.

S

IG

N T

Y P

E

C O

P Y

L

IN

E

SIGN

MESSAGE

M E

T H

O D

CLIENT

COMMENTS

Deleted

5/20/25

15C DELETE

16 XW1 1a

2a

3a

4a

1b

2b

3b

4b

[up left] Sections: AA--JJ

[up left] Columbarium C2

[up right] Assembly Area

[up right] Committal Shelters 1 & 2

X

17 XW1 1a

2a

3a

4a

1b

2b

3b

4b

[left] Committal Shelter 2

[left] Exit

[right] Committal Shelter 1

[right] Assembly Area

X

Revised

5/20/25

18 XW1 1a

2a

3a

4a

1b

2b

3b

4b

[up] Sections: AA--JJ

[up] Columbarium C2

[up] Committal Shelter 2

[up] Visitor Restrooms [isa]

[up] Exit

X New sign replaces existing single-post sign

Added

5/20/25

18A XN2 Floral Regulation - see sign type X

19 XW3 1

[left] Visitor Restroom [isa]

[right] Assembly Area

[right] Committal Shelter 1

[right] Exit

T Attach sign to fence using zip ties

20 NOT

USED

21 Xi1 6 military seals - see sign type D Install on back wall of shelter

22 XW1 1a

2a

3a

4a

1b

2b

3b

4b

[up] Assembly Area

[up] Exit

[up] Committal Shelters 1 & 2

[up] Visitor Restrooms [isa]

X

23 XW1 1a

2a

3a

4a

1b

2b

3b

4b

[up] Exit

[up] Committal Shelters 1 & 2

[up] Visitor Restrooms [isa]

X

Deleted

5/20/25

24 DELETE

Deleted

5/20/25

25 DELETE

END MESSAGE SCHEDULE

C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road F r e d e r i c k , M a r y l a n d 2 1 7 0 1

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

Sign Type Drawing Details and XI1

833CM3030

SS MK

X-104

January 7, 2026

166161

NOTES

KEY

Design Build Consortium | 39 Amber Forest, Hollywood Park, TX 78232 | 210-764-1045 | designbcllc.com

Wayfinding Associates | 2311 Bethel Church Road, Suite 101 Bethel Park, PA 15102 | 412.207.9115 | wfpros.com

IN

P

A R

T N

E R

S H

IP

W

IT

H

Wayfinding a s s o c i a t e sDesign Build Consortium, LLC

A Service-Disabled Veteran Owned Business

D 21”, TYP.

24"

CL CL

3 SIGN TYPE XI1 - DETAILS

X 1/8”= 1”

BASIS OF DESIGN: 2023 VA SIGNAGE DESIGN MANUAL

SIGN SUMMARY

COMPONENTS

NOTES

- REMOVE EXISTING SEALS AND TURN-OVER TO CEMETERY STAFF

- SIGN INSTALLER TO REMOVE EXISTING VERTICAL WALL TRIM PIECES OVERLAPPING THE EXISTING BEAD-BOARD

BEING CAREFUL NOT TO DAMAGE BEAD-BOARD OR ADJACENT TRIM PIECES.

- CUT-OUT AND REMOVE 28”H HORIZONTAL SECTION OF EXISTING BEAD-BOARD AS SHOWN.

- REPLACE REMOVED SECTION OF BEAD-BOARD WITH SMOOTH MDF PANELS OF SAME THICKNESS, ADDING ANY NECESSARY WOOD BLOCKING BEHIND PANELS NECESSARY FOR SUBSEQUENT INSTALLATION OF BRONZE SEALS.

- REPLACE VERTICAL TRIM BOARDS WITH NEW TRIM BOARDS OF SAME SIZE, FINISH AND MATERIAL.

- INSTALL NEW 0.177” MDF HORIZONTAL TRIM PANELS CENTERED OVER SEAMS WHERE EXISTING BEAD-BOARD AND NEW

SMOOTH MDF PANELS MEET.

- PAINT NEW MDF PANELS, REPLACEMENT VERTICAL TRIM BOARDS, HORIZONTAL MDF TRIM PIECES AND

ADJACENT EXISTING WALL BEAD-BOARD FASCIA TO MATCH EXISTING BEAD-BOARD.

- PAINT / RE-PAINT ALL EXISTING VISIBLE WALL AND TRIM ON THIS ELEVATION SO WHOLE WALL ELEVATION MATCHES.

- SEALS TO BE INSTALLED LEVEL AND PLUMB, NO REVEAL WITH BLIND FASTENERS.

- FABRICATOR TO FIELD VERIFY EXISTING CONDITIONS INCLUDING WALL ELEMENT DIMENSIONS TO ASSURE

THE INTENDED APPEARANCE IS EXECUTED AS INDICATED HERE.

A

B

C

D

DESCRIP:

COLOR(S):

DESCRIP:

COLOR(S):

DESCRIP:

COLOR(S):

DESCRIP:

COLOR(S):

ONE (1) SET OF THE SIX BRONZE PLAQUE SEALS OF THE ARMED FORCES OF THE UNITED STATES EXTERIOR GRADE 3-D BAS-RELIEF BRONZE SEALS (MATTHEWS BRONZE OR VA-APPROVED EQUAL)

SEE SPECIFICATIONS SECTION 10 14 00

TWO MDF PANELS TO REPLACE REMOVED BEAD-BOARD PANEL SECTIONS

PAINT TO MATCH EXISTING BEAD-BOARD WALL FACADE

TWO MDF PANELS TO REPLACE REMOVED BEAD-BOARD PANEL SECTIONS

PAINT TO MATCH EXISTING BEAD-BOARD WALL FACADE

TWO REPLACEMENT WOOD TRIM PIECES

PAINT TO MATCH EXISTING BEAD-BOARD WALL FACADE

EQ EQ

EXISTING TRIM TO REMAIN, REPAINT

EXISTING TRIM TO REMAIN, REPAINT

EXISTING TRIM TO REMAIN, REPAINT

EXISTING TRIM TO BE REMOVED AND REPLACED IN-KIND

NEW MDF TRIM

EXISTING BEAD-BOARD TO REMAIN, REPAINT

EXISTING BEAD-BOARD TO REMAIN, REPAINT

NEW MDF TRIM

NEW MDF PANELS

5 SIGN TYPE XI1 - INSTALLATION LAYOUT - ADJUST AS-NEEDED

X 1/8”= 1”

4 SIGN TYPE XI1 - EXISTING PLAQUES TO BE REMOVED

X NTS

THE SIGNAGE DESIGN DEVELOPMENT DOCUMENTS HEREIN ARE BASED ON STAKEHOLDER COMMENTS ON THE SIGNAGE SCHEMATIC DESIGN

THAT UTILIZED THE 2024 NCA DESIGN GUIDE.

HELVETICA REGULAR - 2010 ADA/ABA COMPLIANT TACTILE AND VISUAL TEXT COMPONENTS

HELVETICA BOLD - EMPHASIS TEXT FONT (ADA/ABA VISUAL COMPLIANT ONLY)

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890

ABCDEFGHIJKLMNOPQRSTUVWXYZ

abcdefghijklmnopqrstuvwxyz 1234567890

TYPEFACE COPYRIGHT INFORMATION

TYPEFACES ARE LICENSED BY THEIR CREATORS AND AS SUCH CANNOT BE PROVIDED TO PROJECT PARTICIPANTS OR THE

FABRICATOR BY WAYFINDING ASSOCIATES. TYPEFACES ARE COMMERCIALLY AVAILABLE FOR PURCHASE AND DOWNLOAD

FROM ONLINE FONT RESELLERS LIKE FONTS.COM, MYFONTS.COM AND OTHERS.

2 FONTS

X NTS

1 SIGNAGE NARRATIVE

X NTS

EXISTING TRIM TO BE REMOVED AND REPLACED IN-KINDEXISTING BASE TRIM TO REMAIN, REPAINT

/4

CUT-OUT AND REMOVE 28”H HORIZONTAL SECTION OF EXISTING BEAD-BOARD AND

REPLACE REMOVED SECTION WITH SMOOTH MDF PANELS OF SAME THICKNESS

/4

A D

JU

S

T A

S N

E E

D E

D T

O R

E M

O V

E W

A L L D

A M

A G

E E

X P

O S

E D

B Y

R E

M O

V

IN

G E

X

IS

T

IN

G S

E A

L S

141”

/4

/4

/8

9 3/8"9 3/8"

18 3/4"

A

B

C

D

C

T

Y P.

/8

T Y

P.

/2

E Q

E Q

C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road F r e d e r i c k , M a r y l a n d 2 1 7 0 1

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

Sign Type Drawings: XI3 and XI4

833CM3030

SS MK

X-105

January 7, 2026

166162

NOTES

KEY

Design Build Consortium | 39 Amber Forest, Hollywood Park, TX 78232 | 210-764-1045 | designbcllc.com

Wayfinding Associates | 2311 Bethel Church Road, Suite 101 Bethel Park, PA 15102 | 412.207.9115 | wfpros.com

IN

P

A R

T N

E R

S H

IP

W

IT

H

Wayfinding a s s o c i a t e sDesign Build Consortium, LLC

A Service-Disabled Veteran Owned Business

Bid Set

1 SIGN TYPE XI3 - DETAILS

X NTS

6 SIGN TYPE XI4 - DETAILS

X NTS

290 SIGN SYSTEMS STANDARD EXTERIOR GRADE SLIDE SERIES SIGN

290 SIGN SYSTEMS STANDARD EXTERIOR GRADE SLIDE SERIES SIGN

SIGN SUMMARY

SIGN SUMMARY

COMPONENTS

COMPONENTS

NOTES

NOTES

- SIGN TO BE INSTALLED LEVEL AND PLUMB

- MESSAGING SHOWN IS EXAMPLE ONLY, SEE MESSAGE SCHEDULE FOR INDIVIDUAL SIGN MESSAGES

- SIGN TO BE INSTALLED LEVEL AND PLUMB

- MESSAGING SHOWN IS EXAMPLE ONLY, SEE MESSAGE SCHEDULE FOR INDIVIDUAL SIGN MESSAGES

LAYOUT B

LAYOUT E

LAYOUT C

LAYOUT F

LAYOUT D

LAYOUT G

2 SIGN TYPE XI3 - TOP

X 1/2”= 1”

3 SIGN TYPE XI3 - FRONT

X 1/2”= 1”

4 SIGN TYPE XI3 - SIDE

X 1/2”= 1”

5 SIGN TYPE XI3 - MOUNT LOCATIONS

X NTS

H

WALL

W A

L L

A E

Line 1

Braille

B

A

B

C

E

Line 2 3 /8

DESCRIP:

COLOR(S):

290 SIGN SYSTEMS SLIMLINE LOCKING END CAP, TYP.

150 SILVER

B

DESCRIP:

COLOR(S):

ABS INSERT WITH DIRECT TO SURFACE PRINTED TACTILE SYMBOL, TEXT AND BRAILLE

785 DURANODIC

C

DESCRIP:

COLOR(S):

290 SIGN SYSTEMS TOP/BOTTOM TRIM, TYP.

150 SILVER

A

DESCRIP:

COLOR(S):

EXTRUDED ALUMINUM RAIL CARRIER (NOT SHOWN)

ANODIZED BLACK

D

E DESCRIP:

COLOR(S):

SPACER (FOR SCREW MOUNT SIGNS) -OR- VHB DOUBLE-SIDED PRESSURE SENSITIVE TAPE

BLACK/DARK GRAY

1”H TACTILE TEXT (ALL CAPITAL CHARACTERS) RAISED MINIMUM 0.03125”

WITH GRADE 2 BRAILLE TRANSLATION

HELVETICA REGULAR, CENTERED, 708 SOFT WHITE

GRADE 2 BRAILLE COMPLIANT WITH CURRENT ADA/ANSI REQUIREMENTS

Line 2

Braille

5”H DIRECT TO SURFACE PRINTED TACTILE SYMBOLICON , CENTERED - 708 SOFT WHITELine 1

DESCRIP:

COLOR(S):

290 SIGN SYSTEMS SLIMLINE LOCKING END CAP, TYP.

150 SILVER

B

DESCRIP:

COLOR(S):

290 SIGN SYSTEMS TOP/BOTTOM TRIM, TYP.

150 SILVER

A

DESCRIP:

COLOR(S):

EXTRUDED ALUMINUM RAIL CARRIER (NOT SHOWN)

ANODIZED BLACK

D

EDESCRIP:

COLOR(S):

SPACER (FOR SCREW MOUNT SIGNS) -OR- VHB DOUBLE-SIDED PRESSURE SENSITIVE TAPE

BLACK/DARK GRAY

/8

/8

/4

9"

9 1/4"

3/8"

FEMALE

EMPLOYEE

LOCKER ROOM

7 SIGN TYPE XI4 - TOP

X 1/2”= 1”

8 SIGN TYPE XI4 - FRONT

X 1/2”= 1”

9 SIGN TYPE XI4 - SIDE

X 1/2”= 1”

WALL

W A

L L

A E

Line 1

Braille

Braille

B

A

B

C E

Line 3

Line 2

9"

9 1/4"

3/8"

/4

/8

/8

/4

/8

/8

DESCRIP:

COLOR(S):

ABS INSERT WITH DIRECT TO SURFACE PRINTED TACTILE TEXT AND BRAILLE

785 DURANODIC

C

GRADE 2 BRAILLE COMPLIANT WITH CURRENT ADA/ANSI REQUIREMENTS Braille

3/4”H TACTILE TEXT (ALL CAPITAL CHARACTERS) RAISED MINIMUM 0.03125”

WITH GRADE 2 BRAILLE TRANSLATION

HELVETICA REGULAR, CENTERED, 708 SOFT WHITE

Line 1-3

3/4”

C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road F r e d e r i c k , M a r y l a n d 2 1 7 0 1

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

Sign Type Drawings XN1 and XN2

833CM3030

SS MK

X-106

Bid Set

January 7, 2026

166163

NOTES

KEY

Design Build Consortium | 39 Amber Forest, Hollywood Park, TX 78232 | 210-764-1045 | designbcllc.com

Wayfinding Associates | 2311 Bethel Church Road, Suite 101 Bethel Park, PA 15102 | 412.207.9115 | wfpros.com

IN

P

A R

T N

E R

S H

IP

W

IT

H

Wayfinding a s s o c i a t e sDesign Build Consortium, LLC

A Service-Disabled Veteran Owned Business

C

3 SIGN TYPE XN1 - SIDE, TYP.

X 1/8”= 1”

9 SIGN TYPE XN2 - SIDE, TYP.

X 1/8”= 1”

6 PRE-CAST CONCRETE COLLAR - SIDE, TYP.

X 1/8”= 1”

12 PRE-CAST CONCRETE COLLAR - SIDE, TYP.

X 1/8”= 1”

5 PRE-CAST CONCRETE COLLAR - TOP END DETAIL, TYP.

X 1/8”= 1”

4 SIGN TYPE XN1 - FACE A / FACE B

X 1/8”= 1”

10 SIGN TYPE XN2 - FACE A / FACE B

X 1/8”= 1”

1 SIGN TYPE XN1 - DETAILS

X 1/8”= 1”

7 SIGN TYPE XN2 - DETAILS

X 1/8”= 1”

BASIS OF DESIGN: 2023 VA SIGNAGE DESIGN MANUAL BASIS OF DESIGN: 2023 VA SIGNAGE DESIGN MANUAL

SIGN SUMMARY SIGN SUMMARY

COMPONENTS COMPONENTS

DESCRIP:

COLOR(S):

DESCRIP:

COLOR(S):

PRECAST CONCRETE POST, TYP.

LIGHT SANDBLAST FINISH

PRECAST CONCRETE POST, TYP.

LIGHT SANDBLAST FINISH

A A

B B

C C

DESCRIP:

COLOR(S):

DESCRIP:

COLOR(S):

DESCRIP:

COLOR(S):

DESCRIP:

COLOR(S):

ALUMINUM BLEED BODY NON-ILLUMINATED SIGN CABINET

MATTHEWS PAINT MP07458 CAST BRONZE, SATIN FINISH

ALUMINUM BLEED BODY NON-ILLUMINATED SIGN CABINET

MATTHEWS PAINT MP07458 CAST BRONZE, SATIN FINISH

PRECAST CONCRETE COLLAR

LIGHT SANDBLAST FINISH

PRECAST CONCRETE COLLAR

LIGHT SANDBLAST FINISH

NOTES NOTES

- NO HOLES OR EXPOSED FASTENERS PERMITTED ON FASCIA PANELS

- ANY EXPOSED FASTENERS ON RETURNS TO BE PAINTED TO MATCH ADJACENT SURFACE

- ALL SIGN MATERIALS AND FASTENERS TO BE RUST-PROOF AND/OR OXIDIZATION-PROOF

- ALUMINUM CONSTRUCTION SHALL BE OF WELDED ALUMINUM OF

SUFFICIENT GAUGE TO PREVENT “OIL-CANNING”, WARPING AND ANY

SURFACE UNEVENNESS. ALL SEAMS SHALL BE WELDED AND

GROUND SMOOTH. ANY VISIBLE JOINTS, SEAMS, WELD OR GRIND

MARKS WILL BE UNACCEPTABLE

- ALL WELDS SHOULD BE TREATED TO PREVENT CORROSION.

- SIGN ELEMENTS SHALL BE PAINTED IN ACCORDANCE WITH THE COLOR

SPECIFICATIONS IN THIS DOCUMENT

EACH PAINT SHALL CONTAIN ULTRA-VIOLET INHIBITORS AND SHALL BE

EVENLY SPRAY APPLIED WITH SUFFICIENT TIME ALLOWED BETWEEN

APPLICATIONS FOR PROPER CURING

- THE PAINTED SURFACES HAVE A CONSISTENT SATIN FINISH

(UNLESS OTHERWISE NOTED) AND SHALL BE FREE OF DIRT, GRIT,

MOTTLING AND “ORANGE-PEEL” EFFECT

- POLYURETHANE COATINGS SHALL BE MAP, AS MANUFACTURED BY

MATTHEWS PAINT COMPANY OR APPROVED EQUAL

- SIGN TO BE INSTALLED LEVEL AND PLUMB.

- NO HOLES OR EXPOSED FASTENERS PERMITTED ON FASCIA PANELS

- ANY EXPOSED FASTENERS ON RETURNS TO BE PAINTED TO MATCH ADJACENT SURFACE

- ALL SIGN MATERIALS AND FASTENERS TO BE RUST-PROOF AND/OR OXIDIZATION-PROOF

- ALUMINUM CONSTRUCTION SHALL BE OF WELDED ALUMINUM OF

SUFFICIENT GAUGE TO PREVENT “OIL-CANNING”, WARPING AND ANY

SURFACE UNEVENNESS. ALL SEAMS SHALL BE WELDED AND

GROUND SMOOTH. ANY VISIBLE JOINTS, SEAMS, WELD OR GRIND

MARKS WILL BE UNACCEPTABLE

- ALL WELDS SHOULD BE TREATED TO PREVENT CORROSION.

- SIGN ELEMENTS SHALL BE PAINTED IN ACCORDANCE WITH THE COLOR

SPECIFICATIONS IN THIS DOCUMENT

EACH PAINT SHALL CONTAIN ULTRA-VIOLET INHIBITORS AND SHALL BE

EVENLY SPRAY APPLIED WITH SUFFICIENT TIME ALLOWED BETWEEN

APPLICATIONS FOR PROPER CURING

- THE PAINTED SURFACES HAVE A CONSISTENT SATIN FINISH

(UNLESS OTHERWISE NOTED) AND SHALL BE FREE OF DIRT, GRIT,

MOTTLING AND “ORANGE-PEEL” EFFECT

- POLYURETHANE COATINGS SHALL BE MAP, AS MANUFACTURED BY

MATTHEWS PAINT COMPANY OR APPROVED EQUAL

- SIGN TO BE INSTALLED LEVEL AND PLUMB.

COMPACTED SUB-GRADE COMPACTED SUB-GRADE

POSTCRETE POSTCRETE

R 1/2” TYP.

R 1/2” TYP. R 1/2” TYP.

3" 3"

3/

4” T

YP.

7/8"

/2

1/2"

5 1/2" 5 1/2"

3 1/2" 3 1/2"

2 7/8" 2 7/8"

TY

P.

TY

P.

A A

2 SIGN TYPE XN1 - TOP

X 1/8”= 1”

8 SIGN TYPE XN2 - TOP

X 1/8”= 1”

A ACB B

5 1/2”, TYP. 5 1/2”, TYP.

/4

/4

4 1/2" 4 1/2"

A A B B

C

LINE 1A/B

LINE 1A/B

POLICY STATEMENT - SCALE ELECTRONIC POLICY STATEMENT ARTWORK TO 19”H

AVERY DENNISON MATTE WHITE SC 900-102-O

POLICY STATEMENT - SCALE ELECTRONIC POLICY STATEMENT ARTWORK TO 18”H

AVERY DENNISON MATTE WHITE SC 900-102-O

LINE 1A/B LINE 1A/B

Visitor Information

1 1/2” 1 1/2”

/2

/8

BLIND KEYHOLE MOUNTS, NO REVEAL, TYP.

BLIND KEYHOLE MOUNTS, NO REVEAL, TYP.

1/4” DEEP RECESS, TYP.

SIGNPOST

PRECAST CONCRETE WITH

LIGHT SAND BLAST FINISH

R 1 1/8” TYP.

2 1/4"

1/4” DEEP RECESS, TYP.

SIGNPOST

PRECAST CONCRETE WITH

LIGHT SAND BLAST FINISH

R 1 1/8” TYP.

2 1/4"

PRECAST CONCRETE COLARPRECAST CONCRETE COLAR

EXPANSION JOINT ALL AROUNDEXPANSION JOINT ALL AROUND

GRADEGRADE

T Y

P.

T Y

P.

CC

#3 REBAR AS SHOWN

EACH WAY

#3 REBAR AS SHOWN

EACH WAY

8 1/8"

C

R 1/2” TYP.

3/

4” T

YP.

/2

7/8"

1/2"

11 PRE-CAST CONCRETE COLLAR - TOP END DETAIL, TYP.

X 1/8”= 1”

C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road F r e d e r i c k , M a r y l a n d 2 1 7 0 1

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

Sign Type Drawings: XW1 and XW2

833CM3030

SS MK

X-107

January 7, 2026

166164

NOTES

KEY

Design Build Consortium | 39 Amber Forest, Hollywood Park, TX 78232 | 210-764-1045 | designbcllc.com

Wayfinding Associates | 2311 Bethel Church Road, Suite 101 Bethel Park, PA 15102 | 412.207.9115 | wfpros.com

IN

P

A R

T N

E R

S H

IP

W

IT

H

Wayfinding a s s o c i a t e sDesign Build Consortium, LLC

A Service-Disabled Veteran Owned Business

Bid Set

Office

Restrooms

Memorial Path

Exit

9 SIGN TYPE XW2 - SIDE, TYP.

X 1/8”= 1”

3 SIGN TYPE XW1 - SIDE, TYP.

X 1/8”= 1”

12 PRE-CAST CONCRETE COLLAR - SIDE, TYP.

X 1/8”= 1”

6 PRE-CAST CONCRETE COLLAR - SIDE, TYP.

X 1/8”= 1”

11 PRE-CAST CONCRETE COLLAR - TOP

X 1/8”= 1”

10 SIGN TYPE XW2 - FACE A

X 1/8”= 1”

11 SIGN TYPE XW2 - REAR

X 1/8”= 1”

4 SIGN TYPE XW1 - FACE A / FACE B

X 1/8”= 1”

7 SIGN TYPE XW2 - DETAILS

X 1/8”= 1”

1 SIGN TYPE XW1 - DETAILS

X 1/8”= 1”

BASIS OF DESIGN: 2023 VA SIGNAGE DESIGN MANUALBASIS OF DESIGN: 2023 VA SIGNAGE DESIGN MANUAL

SIGN SUMMARYSIGN SUMMARY

COMPONENTSCOMPONENTS

DESCRIP:

COLOR(S):

DESCRIP:

COLOR(S):

PRECAST CONCRETE POST, TYP.

LIGHT SANDBLAST FINISH

PRECAST CONCRETE POST, TYP.

LIGHT SANDBLAST FINISH

AA

BB

C

C

DESCRIP:

COLOR(S):

DESCRIP:

COLOR(S):

DESCRIP:

COLOR(S):

DESCRIP:

COLOR(S):

ALUMINUM BLEED BODY NON-ILLUMINATED SIGN CABINET ATTACHED TO CONCRETE POST WITH TWO SS 3/16” x 2” SPANNER BOLT AND SHIELD, TYP.

MATTHEWS PAINT MP07458 CAST BRONZE, SATIN FINISH

ALUMINUM BLEED BODY NON-ILLUMINATED SIGN CABINET

MATTHEWS PAINT MP07458 CAST BRONZE, SATIN FINISH

PRECAST CONCRETE COLLAR

LIGHT SANDBLAST FINISH

PRECAST CONCRETE COLLAR

LIGHT SANDBLAST FINISH

2 1/2”H FIRST SURFACE APPLIED VINYL TEXT, HELVETICA BOLD, CENTERED

AVERY DENNISON MATTE WHITE SC 900-102-O

LINE 1-3

NOTES

NOTES

- NO HOLES OR EXPOSED FASTENERS PERMITTED ON FASCIA PANELS

- ANY EXPOSED FASTENERS ON RETURNS TO BE PAINTED TO MATCH ADJACENT SURFACE

- ALL SIGN MATERIALS AND FASTENERS TO BE RUST-PROOF AND/OR OXIDIZATION-PROOF

- ALUMINUM CONSTRUCTION SHALL BE OF WELDED ALUMINUM OF

SUFFICIENT GAUGE TO PREVENT “OIL-CANNING”, WARPING AND ANY

SURFACE UNEVENNESS. ALL SEAMS SHALL BE WELDED AND

GROUND SMOOTH. ANY VISIBLE JOINTS, SEAMS, WELD OR GRIND

MARKS WILL BE UNACCEPTABLE

- ALL WELDS SHOULD BE TREATED TO PREVENT CORROSION.

- SIGN ELEMENTS SHALL BE PAINTED IN ACCORDANCE WITH THE COLOR

SPECIFICATIONS IN THIS DOCUMENT

EACH PAINT SHALL CONTAIN ULTRA-VIOLET INHIBITORS AND SHALL BE

EVENLY SPRAY APPLIED WITH SUFFICIENT TIME ALLOWED BETWEEN

APPLICATIONS FOR PROPER CURING

- THE PAINTED SURFACES HAVE A CONSISTENT SATIN FINISH

(UNLESS OTHERWISE NOTED) AND SHALL BE FREE OF DIRT, GRIT,

MOTTLING AND “ORANGE-PEEL” EFFECT

- POLYURETHANE COATINGS SHALL BE MAP, AS MANUFACTURED BY

MATTHEWS PAINT COMPANY OR APPROVED EQUAL

- SIGN TO BE INSTALLED LEVEL AND PLUMB.

- NO HOLES OR EXPOSED FASTENERS PERMITTED ON FASCIA PANELS

- ANY EXPOSED FASTENERS ON RETURNS TO BE PAINTED TO MATCH ADJACENT SURFACE

- ALL SIGN MATERIALS AND FASTENERS TO BE RUST-PROOF AND/OR OXIDIZATION-PROOF

- ALUMINUM CONSTRUCTION SHALL BE OF WELDED ALUMINUM OF

SUFFICIENT GAUGE TO PREVENT “OIL-CANNING”, WARPING AND ANY

SURFACE UNEVENNESS. ALL SEAMS SHALL BE WELDED AND

GROUND SMOOTH. ANY VISIBLE JOINTS, SEAMS, WELD OR GRIND

MARKS WILL BE UNACCEPTABLE

- ALL WELDS SHOULD BE TREATED TO PREVENT CORROSION.

- SIGN ELEMENTS SHALL BE PAINTED IN ACCORDANCE WITH THE COLOR

SPECIFICATIONS IN THIS DOCUMENT

EACH PAINT SHALL CONTAIN ULTRA-VIOLET INHIBITORS AND SHALL BE

EVENLY SPRAY APPLIED WITH SUFFICIENT TIME ALLOWED BETWEEN

APPLICATIONS FOR PROPER CURING

- THE PAINTED SURFACES HAVE A CONSISTENT SATIN FINISH

(UNLESS OTHERWISE NOTED) AND SHALL BE FREE OF DIRT, GRIT,

MOTTLING AND “ORANGE-PEEL” EFFECT

- POLYURETHANE COATINGS SHALL BE MAP, AS MANUFACTURED BY

MATTHEWS PAINT COMPANY OR APPROVED EQUAL

- SIGN TO BE INSTALLED LEVEL AND PLUMB.

1/4” DEEP RECESS, TYP.

SIGNPOST

PRECAST CONCRETE WITH

LIGHT SAND BLAST FINISH

COMPACTED SUB-GRADECOMPACTED SUB-GRADE

POSTCRETEPOSTCRETE

R 1/2” TYP.

R 1/2” TYP.R 1/2” TYP.

R 1 1/8” TYP.

3"3"

3"

7/8"

/4

3/

4” T

YP.

/2

1/2"

5 1/2"5 1/2"

3 1/2"3 1/2"

2 7/8"2 7/8"

2 1/4"

T Y

P.

TY

P.

AA

8 SIGN TYPE XW2 - TOP

X 1/8”= 1”

2 SIGN TYPE XW1 - TOP

X 1/8”= 1”

AA C

B

C

B

5 1/2”, TYP. 5 1/2”, TYP.5 1/2”, TYP.

/4

/4

4 1/2"

A AA

B

C C

LINE 1A/B

LINE 2A/B

LINE 3A/B

LINE 4A/B

ARROW - 3 5/8” (TIP TO TAIL) FIRST SURFACE APPLIED VINYL SYMBOL, LEFT JUSTIFIED, CENTER VERTICALLY WITH CORRESPONDING TEXT

TEXT - 2 1/2”H FIRST SURFACE APPLIED VINYL TEXT, HELVETICA BOLD, LEFT JUSTIFIED

INTERNATIONAL SYMBOL OF ACCESSIBILITY - 3 5/8”H FIRST SURFACE APPLIED VINYL TEXT, LEFT JUSTIFIED, CENTER VERTICALLY WITH CORRESPONDING TEXT

AVERY DENNISON MATTE WHITE SC 900-102-O

LINE 1-4A/B

BLIND KEYHOLE MOUNTS, NO REVEAL, TYP.

1/4” DEEP RECESS, TYP.

SIGNPOST

PRECAST CONCRETE WITH

LIGHT SAND BLAST FINISH

R 1 1/8” TYP.

2 1/4"

2 1/4"

6 3/4"

/8

/4

/8

PRECAST CONCRETE COLAR PRECAST CONCRETE COLAR

EXPANSION JOINT ALL AROUND EXPANSION JOINT ALL AROUND

GRADE GRADE GRADE GRADE

T Y

P.

T Y

P.

C C

#3 REBAR AS SHOWN

EACH WAY

#3 REBAR AS SHOWN

EACH WAY

LINE 1

LINE 2

LINE 3

Funeral

Staging

Area

B B

/4

/4

/4

/8

2 1/4" 2 1/4"

EQ EQEQ EQ

/4

/4 ” C L

C L

CL

EQEQ

/4

5 PRE-CAST CONCRETE COLLAR - TOP END DETAIL, TYP.

X 1/8”= 1”

R 1/2” TYP.

3/

4” T

YP.

7/8"

/2

1/2"

C

C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road F r e d e r i c k , M a r y l a n d 2 1 7 0 1

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

Sign Type Drawings: XW3 and XW5

833CM3030

SS MK

X-108

January 7, 2026

166165

NOTES

KEY

Design Build Consortium | 39 Amber Forest, Hollywood Park, TX 78232 | 210-764-1045 | designbcllc.com

Wayfinding Associates | 2311 Bethel Church Road, Suite 101 Bethel Park, PA 15102 | 412.207.9115 | wfpros.com

IN

P

A R

T N

E R

S H

IP

W

IT

H

Wayfinding a s s o c i a t e sDesign Build Consortium, LLC

A Service-Disabled Veteran Owned Business

Bid Set

A C

6 SIGN TYPE XW5 - SIDE, TYP.

X 1/8”= 1”

9 PRE-CAST CONCRETE COLLAR - SIDE, TYP.

X 1/8”= 1”

7 SIGN TYPE XW5 - FACE A / FACE B

X 1/8”= 1”

4 SIGN TYPE XW5 - DETAILS

X 1/8”= 1”

BASIS OF DESIGN: 2023 VA SIGNAGE DESIGN MANUAL

SIGN SUMMARY

COMPONENTS

DESCRIP:

COLOR(S):

PRECAST CONCRETE POST, TYP.

LIGHT SANDBLAST FINISH

A

B

C

DESCRIP:

COLOR(S):

DESCRIP:

COLOR(S):

ALUMINUM BLEED BODY NON-ILLUMINATED SIGN CABINET

MATTHEWS PAINT MP07458 CAST BRONZE, SATIN FINISH

PRECAST CONCRETE COLLAR

LIGHT SANDBLAST FINISH

NOTES

- NO HOLES OR EXPOSED FASTENERS PERMITTED ON FASCIA PANELS

- ANY EXPOSED FASTENERS ON RETURNS TO BE PAINTED TO MATCH ADJACENT SURFACE

- ALL SIGN MATERIALS AND FASTENERS TO BE RUST-PROOF AND/OR OXIDIZATION-PROOF

- ALUMINUM CONSTRUCTION SHALL BE OF WELDED ALUMINUM OF

SUFFICIENT GAUGE TO PREVENT “OIL-CANNING”, WARPING AND ANY

SURFACE UNEVENNESS. ALL SEAMS SHALL BE WELDED AND

GROUND SMOOTH. ANY VISIBLE JOINTS, SEAMS, WELD OR GRIND

MARKS WILL BE UNACCEPTABLE

- ALL WELDS SHOULD BE TREATED TO PREVENT CORROSION.

- SIGN ELEMENTS SHALL BE PAINTED IN ACCORDANCE WITH THE COLOR

SPECIFICATIONS IN THIS DOCUMENT

EACH PAINT SHALL CONTAIN ULTRA-VIOLET INHIBITORS AND SHALL BE

EVENLY SPRAY APPLIED WITH SUFFICIENT TIME ALLOWED BETWEEN

APPLICATIONS FOR PROPER CURING

- THE PAINTED SURFACES HAVE A CONSISTENT SATIN FINISH

(UNLESS OTHERWISE NOTED) AND SHALL BE FREE OF DIRT, GRIT,

MOTTLING AND “ORANGE-PEEL” EFFECT

- POLYURETHANE COATINGS SHALL BE MAP, AS MANUFACTURED BY

MATTHEWS PAINT COMPANY OR APPROVED EQUAL

- SIGN TO BE INSTALLED LEVEL AND PLUMB.

COMPACTED SUB-GRADE

POSTCRETE

R 1/2” TYP.

3"

5 1/2"

3 1/2"

2 7/8"

TY

P.

A

5 SIGN TYPE XW3 - TOP

X 1/8”= 1”

5 1/2”, TYP.

/4

4 1/2"

A B

LINE 2A/B

LINE 1A/B

ARROW - 3 5/8” (TIP TO TAIL) FIRST SURFACE APPLIED VINYL SYMBOL, LEFT JUSTIFIED

TEXT - 2 1/2”H FIRST SURFACE APPLIED VINYL TEXT, LEFT JUSTIFIED

INTERNATIONAL SYMBOL OF ACCESSIBILITY - 3 5/8”H FIRST SURFACE APPLIED VINYL TEXT, HELVETICA BOLD, LEFT JUSTIFIED, CENTER VERTICALLY WITH CORRESPONDING TEXT

LINE 1A/B

LINE 2A/B

3 1/4”

1/4” DEEP RECESS, TYP.

SIGNPOST

PRECAST CONCRETE WITH

LIGHT SAND BLAST FINISH

R 1 1/8” TYP.

2 1/4"

/2 "Office

Restrooms

Memorial Path

Exit

2 SIGN TYPE XW3 - SIDE, TYP.

X 1/8”= 1”

3 SIGN TYPE XW3 - FRONT

X 1/8”= 1”

1 SIGN TYPE XW3 - DETAILS

X 1/8”= 1”

BASIS OF DESIGN: 2023 VA SIGNAGE DESIGN MANUAL

SIGN SUMMARY

COMPONENTS

NOTES

- DRILL D 3/8” HOLES AT PANEL CORNERS AND USE CABLE TIES WITH FERRULES TO ATTACH TO MOUNT SURFACE/STRUCTURE

- ALL SIGN MATERIALS AND FASTENERS TO BE RUST-PROOF AND/OR OXIDIZATION-PROOF

- SIGN ELEMENTS SHALL BE PAINTED IN ACCORDANCE WITH THE COLOR

SPECIFICATIONS IN THIS DOCUMENT

EACH PAINT SHALL CONTAIN ULTRA-VIOLET INHIBITORS AND SHALL BE

EVENLY SPRAY APPLIED WITH SUFFICIENT TIME ALLOWED BETWEEN

APPLICATIONS FOR PROPER CURING

- THE PAINTED SURFACES HAVE A CONSISTENT SATIN FINISH

(UNLESS OTHERWISE NOTED) AND SHALL BE FREE OF DIRT, GRIT,

MOTTLING AND “ORANGE-PEEL” EFFECT

- POLYURETHANE COATINGS SHALL BE MAP, AS MANUFACTURED BY

MATTHEWS PAINT COMPANY OR APPROVED EQUAL

- SIGN TO BE INSTALLED LEVEL AND PLUMB.

1 SIGN TYPE XW3 - TOP

X 1/8”= 1”

B

A

A

LINE 1

LINE 2

LINE 3

LINE 4

A DESCRIP:

COLOR(S):

3MM DIBOND ALUMINUM COMPOSITE PANEL, PAINTED WITH APPLIED VINYL GRAPHICS

MATTHEWS PAINT MP07458 CAST BRONZE, SATIN FINISH (BOTH SIDES)

ARROW - 3 5/8” (TIP TO TAIL) FIRST SURFACE APPLIED VINYL SYMBOL, LEFT JUSTIFIED, CENTER VERTICALLY WITH CORRESPONDING TEXT

TEXT - 2 1/2”H FIRST SURFACE APPLIED VINYL TEXT, HELVETICA BOLD, LEFT JUSTIFIED

INTERNATIONAL SYMBOL OF ACCESSIBILITY - 3 5/8”H FIRST SURFACE APPLIED VINYL TEXT, LEFT JUSTIFIED, CENTER VERTICALLY WITH CORRESPONDING TEXT

AVERY DENNISON MATTE WHITE SC 900-102-O

LINE 1-4A/B

BLIND KEYHOLE MOUNTS, NO REVEAL, TYP.

M in w h e re p o ss ib le

/8

/4

/8

4 1/2"

2 1/4"

6 3/4"

/8

/4

PRECAST CONCRETE COLAR

EXPANSION JOINT ALL AROUND

GRADE

T Y

P.

C

#3 REBAR AS SHOWN

EACH WAY

B

R 1/2” TYP.

3/

4” T

YP.

/2

7/8"

1/2"

8 PRE-CAST CONCRETE COLLAR - TOP END DETAIL, TYP.

X 1/8”= 1”

C

C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road F r e d e r i c k , M a r y l a n d 2 1 7 0 1

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

Sign Demolition Location Plan

833CM3030

SS MK

X-109

January 7, 2026

166166

NOTES

NOT TO SCALE

KEY

Design Build Consortium | 39 Amber Forest, Hollywood Park, TX 78232 | 210-764-1045 | designbcllc.com

Wayfinding Associates | 2311 Bethel Church Road, Suite 101 Bethel Park, PA 15102 | 412.207.9115 | wfpros.com

IN

P

A R

T N

E R

S H

IP

W

IT

H

Wayfinding a s s o c i a t e sDesign Build Consortium, LLC

A Service-Disabled Veteran Owned Business

E

AB

VR

I

J

OP

Q

S

Z

Y

X

V

W

U

T

N

MC

R1

R2

H MA

MB

K

L

A

B

CWM

D

C

G

AA

BB

CC

EE

HH

JJ

FF

DD

COL2

COL1

CS2

CS1

FP

AA

GG2

GG1

F

2Post & Panel

Post & Panel

Post & Panel

Wall Signs

Seals

1 4 5Post & Panel Wall Signs Post & Panel3 Post & Panel2 Seals

1 Post & Panel - Demo sign

- BURIAL SECTIONS

- MAIN DESTINATIONS

AA - ASSEMBLY AREA

AB - ADMINISTRATION BUILDING

COL1 - COLUMBARIUM 1

COL2 - COLUMBARIUM 2

CS1 - COMMITTAL SHELTER 1

CS2 - COMMITTAL SHELTER 2

CWM - CIVIL WAR MEMORIAL

FP - FLAG POLE

VC - VISITOR RESTROOMS

12 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_amended
12 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_amended2