This is a product marketing brochure for ConVault Protected Aboveground Storage Tanks (ASTs) manufactured by United Concrete Products. The document describes a dual-containment fuel storage system consisting of a steel primary tank housed within a six-inch thick concrete vault that provides secondary containment, thermal insulation, vehicle impact protection, and projectile resistance.

ConVault Protected ASTs are manufactured in sizes ranging from 125 to 12,000 US gallons (500 to 45,000 liters) with options for multi-compartment configurations. Units are shop-fabricated under strict quality controls in accordance with UL 2085, ULC-S655, and ULC-S602 standards, with primary steel tanks fabricated per UL 142 (Seventh Edition). The system meets NFPA 30, 30A, and 31; UFC; BOCA; SBCCI; and International Fire Code requirements. Each tank undergoes exhaustive factory testing including dual pressure tests, 2-hour liquid-pool and furnace fire tests, vehicle impact tests, and projectile resistance tests. The product has been approved by environmental and fire protection officials in all US states, all Canadian provinces, all Australian states, and multiple European nations. Over 30,000 units have been installed worldwide since 1986 with no reported system failures. ConVault ASTs offer 20 or 30-year warranties, ship as finished assemblies, and have lower operating costs than comparable AST alternatives due to reduced fuel vapor loss and water vapor gain from thermal stability. The California Air Resources Board has certified the tanks for Phase I and II balanced vapor recovery, including methanol/ethanol blends.

View the file

Other files

File Type Posted
Amendment 4-833CM3030 - CD1 - Historic Hardware.pdf PDF
Amendment 4-833CM3030 - BID - HA-001 from 20260422 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - CU-105 from 20260107 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - 23 11 13 Fuel Storage Tanks.pdf PDF
Amendment 4-833CM3030 - BID - 037 - CU-105 UTILITY PLAN (R2).pdf PDF
Amendment 4-833CM3030 - BID - 26 29 23 Engine Control and Monitoring.pdf PDF
Amendment 4-833CM3030 - BID - 028 - CP-105 PAVING PLAN (R2).pdf PDF
Amendment 4-833CM3030 - BID - SN-104 105 and X-series from 20260107 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - Historic Pages from 20260422 - 833CM3030 - BID - SET A-004 005 132 133 154 155.pdf PDF
Amendment 4-ConVault Specification with UL 752 Level 8.pdf PDF
Amendment 4-Convault Storage tank 500 GL-telford.pdf PDF
Amendment 4-833CM3030 - BID - 020 - CG-201 POND AND CRYPT FIELD SECTIONS (R1).pdf PDF
Amendment 4-AE-113 from 20260422 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-AE-113 833CM3030 - BID - SET.pdf PDF
S02 36C78626R0058 Amendment 0004.docx DOCX document
Amendment 4-833CM3030 - CD1 - Historic Preservation.pdf PDF
Amendment 4-SED FCA - 04212022_Camp Nelson.pdf PDF
Amendment 4-833CM3030 - BID - AE-110 from 20260422 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - 328400 Plant Irrigation_10-31-24.pdf PDF
Amendment 4- 36C78626R0058 FuelForce 814 Advanced Fuel Controller Brochure.pdf PDF
Amendment 4-240524-Camp Nelson National Cemetery - KY- SUE Field Report Deliverable.pdf PDF
Amendment 4-833CM3030 - BID - AE-150 from 20260422 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - 07 42 43 Plastic Panel.pdf PDF
Amendment 4-833CM3030 - BID- EQUIPMENT STORAGE GARAGE-AE-141.pdf PDF
Amendment 4-GI-104 from 20260107 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - 231123 NatGas.pdf PDF
Amendment 4- 833CM3030 - BID - 072727 - BARRIER VAPOR.pdf PDF
Amendment 4-3189 ECS Geotechnical Engineering Report - Expansion Area.pdf PDF
Amendment 4-833CM3030 - BID - 329000 Planting.pdf PDF
Amendment 4-3189 ECS Geotechnical Engineering Report - Camp Nelson Cemetery.pdf PDF
Amendment 4-833CM3030 - BID - 050 - S-101 STRUCTURAL PLAN (R2).pdf PDF
Amendment 4-Lightning Protection Asmnt Report_Camps Nelson Cemetery.pdf PDF
Amendment 4-Dispensing System Controller-SafeSite DSC with specs.pdf PDF
Amendment 4-833CM3030 - BID - CD-102 from 20260107 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-AD-150 from 20260107 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - 33 56 10 Temporary Fuel Storage Tanks.pdf PDF
Amendment 4-833CM3030 - BID - 052 - S-202 MATERIALS STORAGE BLDG. FRAMING (R2).pdf PDF
Amendment 4-3189 ECS Geotechnical Engineering Report - Maintenance Area.pdf PDF
S06_36C78626R0058 Amend. 0003.pdf PDF
S02 Amendement 36C78626R0058 0002.pdf PDF
S02 amendment 2.pdf PDF
S02 Fire Alarm Panel.pdf PDF
S02 Liquidated Damages 833CM3030_CNNC FCA Corrections CONS.pdf PDF
S02 12 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_addendum01.pdf PDF
S02 Amendment 36C78626R0058 0001.pdf PDF
P07 Jessamine Camp Nelson Building.pdf PDF
S02_Price Proposal Breakdown.docx DOCX document
S02_Attachment - Past Performance Questionnaire.docx DOCX document
P07 Jessamine Camp Nelson Highway.pdf PDF
S02_Attachment - DOL Payroll Form.pdf PDF
Show 40 more

Latest 50 of 67 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AbovegroundThe ConVault Advantage 1-800-234-3119

Ph: (203) 269-3119 * (800) 234-3119 * Fax: (203) 265-4941 www.unitedconcrete.com

173 Church St. * Yalesville, CT 06492

Safe Convenient

Cost-effective is a state-of-the-art, cost-efficient way to meet your storage needs.

Put the storage tank of choice to work for you

- ConVault.

At last there is an environmentally safe and practi-cal alternative for storing petroleum-based products:

ConVault’s complete aboveground vaulted tank and fueling system. Constructed of steel and housed in an attractive concrete vault, the double containment tank

Fuel TanksFuel Tanks

Protected Tanks. Primary and secondary con-tainment are independently tested at the plant in accordance with UL and ULC requirements.

The ConVault Protected AST is listed in accor-dance with UL 2085, ULC-S655, and ULC-S602 Insulated/Secondary Containment for Above ground Storage Tanks, Protected Type.

The six-inch thick (6”) concrete exterior acts as a thermal mass reducing temperature variations, provides a non-corrosive, durable exterior, and provides protection for the secondary containment.

The ConVault Protected AST system has passed numerous performance tests including 2-hour liquid-pool and furnace fire tests, vehicle impact test and projectile resistance test. Numerous real life events have also proven the safety of the system. The end result: owners and opera-tors of ConVault Protected AST’s are provided with PEACE OF MIND.

Each ConVault

Protected AST is exhaus-tively production tested at the factory before shipment to its destination. ConVault Protected AST’s meet NFPA 30, 30A and 31; UFC, BOCA, SBCCI, and International Fire Code fire safety requirements and provide grounding connec-tions in accordance with NFPA 780. ConVault Protected AST’s have been approved by envi-ronmental and fire protection officials in all states of Australia, all provinces of Canada, all states of the USA, and by government officials of the

Czech Republic, England, Finland, Germany, Poland, Russia, and Slovakia.

The California Air Resources Board has certified ConVault Protected AST’s for Phase

I and II balanced vapor recovery, including methanol/ethanol blends. ConVault Protected AST’s meet all safety requirements for primary and secondary containment, leak monitoring, spill containment and overfill protection. Specific jurisdictions may have special requirements for tank accessories. Contact your local representa-tive for local regulations.

With the first installation in 1986, over 30,000 tanks are now in service at extremely diverse locations in over 20 different countries without a single reported system failure to date!

It is this historical performance that has been the cornerstone of regulatory comfort with the ConVault protected AST product.

The ConVault Protected AST system will provide ongoing value for fuel storage. More stringent regulations are consistently on the horizon; however, with a ConVault Protected AST the need for updating is greatly reduced. ConVault operating costs are substantially lower than virtually any other AST on the market. The concrete exterior provides protection for the secondary containment, and acts as a thermal mass, reducing temperature variations (which reduces fuel vapor loss and water vapor gain), while providing a non-corro-sive, durable exterior.

Interest in the preservation of our environment has prompted all levels of many governments to issue strict guidelines for the installation, opera-tion and removal of underground storage tanks (UST’s). As a result, owners and operators are faced with tedious and complicated rules and paperwork. They may also be faced with expen-sive upgrades, purchase of monitoring equipment, testing, and obtaining pollution liability insurance to comply with these requirements. In the event of a leak, the actual costs for soil and groundwater clean-up can be catastrophic. As aboveground storage tanks (AST’s) replace UST’s on a more regular basis, strict guidelines are being issued for AST’s as well. ConVault’s innovative Protected AST’s are the proven solution for these problems.

ConVault Protected AST’s are engineered to survive in the real world. Utilizing patented manufacturing procedures, the resulting product is a tank for flammable liquids seamlessly encapsulated in six-inch thick concrete with integral secondary containment, thermal stability, vehicle impact protection, and projectile protection. The system contains no cold joints or heat transfer points on the bottom or the sides.

ConVault primary steel tanks (including spill con-tainment basins) are fabricated in accordance with UL 142 (Seventh Edition). Each unit is pressure tested twice at the factory using ConVault patent-ed processes to insure proper performance in the field. ConVault protected AST’s are shop-fabri-cated under strict quality controls in accordance with UL 2085 and ULC-S655 and ULC-S602 for

The Aboveground Solution to the

Underground Problem

Engineered for Safety

Meets Government, Environmental and Fire Safety Regulations

Designed for Value

To find out more about

ConVault products, please visit the web site at www.unitedconcrete.com or call 800-234-3119

To meet your fuel storage needs, ConVault Protected AST’s are manufactured in sizes ranging from 125 to 12,000 US gallons, or 500 to 45,000 liters (including multi-compartment op-tions). ConVault AST’s have a 20 or 30 year war-ranty. ConVault Protected AST’s are produced at manufacturing sites around the world. The unit is shipped as a finished assembly, normally limit-ing the need for major on-site work to providing a concrete pad and electrical service. Although the units are intended for stationary service, in the event of changing requirements they can be moved and reinstalled. ConVault Protected AST’s are thus an asset, compared to UST’s or “tanks in dikes” which are usually considered a liability.

Always consult local fire and building codes before installing a ConVault Protected AST since environmental and fire safety regulations can vary between jurisdictions.