Amendment 4-833CM3030 - BID - 052 - S-202 MATERIALS STORAGE BLDG. FRAMING (R2).pdf

PDF 1 MB Posted

Attached to
CAMP NELSON NATIONAL CEMETERY, KY 833CM3030 – CORRECT FCA DEFICIENCIES
Solicitation number
36C78626R0058
Issued by

About this file

This is a set of architectural drawings for a covered material storage building project at Camp Nelson National Cemetery in Covington, Louisiana. The project is identified as drawing number S-202 for the Materials Storage Building Framing, prepared by Walker Federal Services, LLC as the prime consultant with Principal Engineering as a sub-consultant. The drawings are part of a Bid Set dated January 7, 2026, and are designated as a response to an RFI Amendment 004 dated October 22, 2026.

The building design specifications include a metal roof deck construction (20-gauge, 1-1/2" GR50 steel with hot-dip galvanizing) supported by steel structural components: HSS 6x6x1/4 steel columns and rafters, MC8x20 steel channel purlins, and MC6x12 steel girts. The structure features cast-in-place concrete walls with rubbed finish, metal wall panels, metal gutters, and rain water leaders. Overall building dimensions are 49'-0" long by 32'-6" wide with a 3:12 roof pitch. The design includes four base plate connection details (designated as Baseplate A, B, and C) for column-to-wall connections using anchor bolts. Key notes specify that bolted and mechanical fastener connections must be designed, detailed shop drawings must be submitted, and all exposed concrete requires a rubbed finish. The project is associated with the U.S. Department of Veterans Affairs National Cemetery Administration and references correction of FCA deficiencies.

View the file

Other files

File Type Posted
Amendment 4-833CM3030 - CD1 - Historic Hardware.pdf PDF
Amendment 4-833CM3030 - BID - HA-001 from 20260422 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - CU-105 from 20260107 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - 23 11 13 Fuel Storage Tanks.pdf PDF
Amendment 4-833CM3030 - BID - 037 - CU-105 UTILITY PLAN (R2).pdf PDF
Amendment 4-833CM3030 - BID - 26 29 23 Engine Control and Monitoring.pdf PDF
Amendment 4-833CM3030 - BID - 028 - CP-105 PAVING PLAN (R2).pdf PDF
Amendment 4-833CM3030 - BID - SN-104 105 and X-series from 20260107 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - Historic Pages from 20260422 - 833CM3030 - BID - SET A-004 005 132 133 154 155.pdf PDF
Amendment 4-ConVault Specification with UL 752 Level 8.pdf PDF
Amendment 4-Convault Storage tank 500 GL-telford.pdf PDF
Amendment 4-Convault Brochure 2019 (003).pdf PDF
Amendment 4-833CM3030 - BID - 020 - CG-201 POND AND CRYPT FIELD SECTIONS (R1).pdf PDF
Amendment 4-AE-113 from 20260422 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-AE-113 833CM3030 - BID - SET.pdf PDF
S02 36C78626R0058 Amendment 0004.docx DOCX document
Amendment 4-833CM3030 - CD1 - Historic Preservation.pdf PDF
Amendment 4-SED FCA - 04212022_Camp Nelson.pdf PDF
Amendment 4-833CM3030 - BID - AE-110 from 20260422 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - 328400 Plant Irrigation_10-31-24.pdf PDF
Amendment 4- 36C78626R0058 FuelForce 814 Advanced Fuel Controller Brochure.pdf PDF
Amendment 4-240524-Camp Nelson National Cemetery - KY- SUE Field Report Deliverable.pdf PDF
Amendment 4-833CM3030 - BID - AE-150 from 20260422 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - 07 42 43 Plastic Panel.pdf PDF
Amendment 4-833CM3030 - BID- EQUIPMENT STORAGE GARAGE-AE-141.pdf PDF
Amendment 4-GI-104 from 20260107 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - 231123 NatGas.pdf PDF
Amendment 4- 833CM3030 - BID - 072727 - BARRIER VAPOR.pdf PDF
Amendment 4-3189 ECS Geotechnical Engineering Report - Expansion Area.pdf PDF
Amendment 4-833CM3030 - BID - 329000 Planting.pdf PDF
Amendment 4-3189 ECS Geotechnical Engineering Report - Camp Nelson Cemetery.pdf PDF
Amendment 4-833CM3030 - BID - 050 - S-101 STRUCTURAL PLAN (R2).pdf PDF
Amendment 4-Lightning Protection Asmnt Report_Camps Nelson Cemetery.pdf PDF
Amendment 4-Dispensing System Controller-SafeSite DSC with specs.pdf PDF
Amendment 4-833CM3030 - BID - CD-102 from 20260107 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-AD-150 from 20260107 - 833CM3030 - BID - SET.pdf PDF
Amendment 4-833CM3030 - BID - 33 56 10 Temporary Fuel Storage Tanks.pdf PDF
Amendment 4-3189 ECS Geotechnical Engineering Report - Maintenance Area.pdf PDF
S06_36C78626R0058 Amend. 0003.pdf PDF
S02 Amendement 36C78626R0058 0002.pdf PDF
S02 amendment 2.pdf PDF
S02 Fire Alarm Panel.pdf PDF
S02 Liquidated Damages 833CM3030_CNNC FCA Corrections CONS.pdf PDF
S02 12 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_addendum01.pdf PDF
S02 Amendment 36C78626R0058 0001.pdf PDF
P07 Jessamine Camp Nelson Building.pdf PDF
S02_Price Proposal Breakdown.docx DOCX document
S02_Attachment - Past Performance Questionnaire.docx DOCX document
P07 Jessamine Camp Nelson Highway.pdf PDF
S02_Attachment - DOL Payroll Form.pdf PDF
Show 40 more

Latest 50 of 67 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D

C

B

A

1 3

25'-0" 3'

-6

'-0

'-0

'-0

3'

-6

4'-0" 3'-6"

LINE OF ROOF AND

GUTTER ABOVE TYP.

32'-6"

'-0

DOWNSPOUT, TYP.

6" 6"

6" 6"

DS

DS

D

C

B

A

1 3

LINE OF BUILDING

BELOW

3:12

1'-4"

TYP.

T.O.S.

T.O.S.

2% PITCH

SEE SITE PLAN

A B C D

BEYOND

4' -0

"1'-4"

TYP.

BEYOND

T.O.S.

METAL GUTTER

20GA. 1-1/2" GR50

STEEL DECKING, HDG

MC8X20 STEEL

CHANNEL PURLIN, HDG

HSS 6X6X1/4 STEEL

RAFTER, HDG

RAIN WATER LEADER

BLOCKING

1/4" = 1'-0"1 COVERED MATERIAL STORAGE BINS FLOOR PLAN

1/4" = 1'-0"2 COVERED MATERIAL STORAGE BINS ROOF PLAN

1/4" = 1'-0"4 COVERED MATERIAL STORAGE BINS SIDE ELEVATION

1/4" = 1'-0"3 COVERED MATERIAL STORAGE BINS FRONT ELEVATION

1/4" = 1'-0"6 COVERED MATERIAL STORAGE BINS REAR ELEVATION

1/4" = 1'-0"5 COVERED MATERIAL STORAGE BINS SECTION

1 1/2" = 1'-0"10 TYP. GUTTER DETAIL

12'-6" 12'-6"C L C LC L

6'-3" 6'-3" 6'-3"6'-3"C L C L

3 3

3 3

4' -8

4'

-8

4' -8

4' -8

4'

-8

4' -8

4' -8

4'

-8

4' -8

C L

C L C L

C L C L

C L

C L C L

C L C L

6'-3" 6'-3" 6'-3"6'-3"

C L C L

D C B A

'-0

'-0

'-4

4' -0

'-0

3 4"

'-0

EAVE

6' -0

'-1

0"

'-0

3 4"

6' -0

'-1

0"

'-0

3 4"

26'-2"

7" 7"

7" 7" 25'-0"

7" 7"

'-2

7" 7"

PURLINS AT 8 EQ. SPACES

D

C

B

A

1 3

25'-0" 3'

-6

'-0

'-0

'-0

3'

-6

4'-0" 3'-6"

LINE OF ROOF AND

GUTTER ABOVE TYP.

32'-6"

'-0

DOWNSPOUT, TYP.

6" 6"

6" 6"

D

C

B

A

LINE OF BUILDING

BELOW

1/4" = 1'-0"1 COVERED MATERIAL STORAGE BINS FLOOR PLAN

12'-6" 12'-6"C L C LC L

6'-3" 6'-3" 6'-3"6'-3"C L C L

3 3

3 3

4' -8

4'

-8

4' -8

4' -8

4'

-8

4' -8

4' -8

4'

-8

4' -8

C L

C L C L

C L C L

C L

C L C L

C L C L

6'-3" 6'-3" 6'-3"6'-3"

C L C L

26'-2"

7" 7"

7" 7" 25'-0"

7" 7"

'-2

7" 7"

1" = 1'-0"9 COLUMN TO WALL CONNECTION - BASEPLATE "B"

HSS 6x6x1

COLUMN, HDG

CONCRETE WALL

(SEE SHT S-201 FOR

REINFORCEMENT)

1'-2"

1' -2

CO

N

CR

ET

E

W

AL

L

10" SQ. X 5 8" THK.

BASEPLATE

10" SQ. X 5 8" THK.

BASEPLATE, HDG

HSS 6x6x1

COLUMN, HDG

(4) 3/4" ANCHOR

BOLTS, HDG

C L 8"

PLAN VIEW SECTION

1' -0

BO

LT

EM

BE

DE

D 3/4" ANCHOR BOLT,

HDG (TYP.)

MC6X12

COLUMN, HDG

CONCRETE WALL

(SEE SHT S-201 FOR

REINFORCEMENT)

1'-2"

1' -2

CO

N

CR

ET

E

W

AL

L

8" SQ. X 12" THK.

BASEPLATE, HDG

8" SQ. X 12" THK.

BASEPLATE, HDG

MC6x12

COLUMN, HDG

(4) 5/8" ANCHOR

BOLTS, HDG

C L 6"

PLAN VIEW SECTION

1' -0

BO

LT

EM

BE

DE

D

5/8" ANCHOR BOLT,

HDG (TYP.)6"

8"

1" = 1'-0"8 COLUMN TO WALL CONNECTION - BASEPLATE "A"

TYP

4"

2"1

4" PL, HDG

(TYP.)

5"

2"

5/8" ANCHOR

BOLT, HDG (TYP.)

1' -0

BO

LT

EM

BE

DE

D

(4) 5/8" ANCHOR

BOLTS, HDG

PLAN VIEW SECTION

4" PL, HDG

(TYP.)

HSS 6x6x1

COLUMN, HDG

1" = 1'-0"7 COLUMN TO WALL CONNECTION - BASEPLATE "C"

UN

I TED

STATES OF AMER

I C

A

EN

T

OF VETERANS

AFFA

IRS

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

PRIME CONSULTANT

Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701

CONSULTANTS

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

833CM3030

ACM LMR

JANUARY 7, 2026

Bid Set

128 NORTHPARK BLVD.,

COVINGTON, LA 70433

ALAL

Engineering

PRINCIPPRINCIP

METAL ROOF DECK, 20GA. 1-1/2" GR50 STEEL,

HDG w/ 4'-3" MAX. SUPPORT SPACING

METAL GUTTER, TYP.

MC6x12 STEEL GIRT WITH BASE PLATE "A", HDG

RAIN WATER LEADER, TYP.

20GA. 1-1/2" METAL WALL PANELS / GIRT SYSTEM,

HDG

HSS 6x6x1

4 STEEL COLUMN WITH BASE PLATE "B",

HDG

CAST IN PLACE CONCRETE WALL, RUBBED FINISH

MC8x20 STEEL CHANNEL, HDG

HSS 6x6x1

4 STEEL RAFTER, HDG

STEEL PURLINS MC 8x20, HDG

LOUVER

PIPE BOLLARD, TYP.

MATERIALS STORAGE BLDG.

FRAMING

S-202

MPM

HSS 6x6x1

4 STEEL COLUMN WITH BASE PLATE "C",

HDG

1. DESIGN AND DETAIL BOLTED AND MECHANICAL

FASTENER CONNECTIONS FOR THE FOLLOWING:

A. COLUMN TO RAFTER

B. PURLIN TO RAFTER

C. DECK TO PURLINS

D. WALL PANEL TO COLUMNS

2. CONNECTIONS MAY BE PINNED. MWFRS

LATERAL LOAD RESISTANCE IS BY FIXED BASE

COLUMNS.

3. SUBMIT DETAILED SHOP DRAWINGS.

4. RUBBED FINISH REQUIRED ON ALL EXPOSED

CONCRETE.

NOTES KEY

RFI - AMMENDMENT 004 10/22/26

Sheets and Views
MATERIAL STORAGE BINS

File details come from the government source that posted it. Updated .