This is a set of architectural drawings for a covered material storage building project at Camp Nelson National Cemetery in Covington, Louisiana. The project is identified as drawing number S-202 for the Materials Storage Building Framing, prepared by Walker Federal Services, LLC as the prime consultant with Principal Engineering as a sub-consultant. The drawings are part of a Bid Set dated January 7, 2026, and are designated as a response to an RFI Amendment 004 dated October 22, 2026.
The building design specifications include a metal roof deck construction (20-gauge, 1-1/2" GR50 steel with hot-dip galvanizing) supported by steel structural components: HSS 6x6x1/4 steel columns and rafters, MC8x20 steel channel purlins, and MC6x12 steel girts. The structure features cast-in-place concrete walls with rubbed finish, metal wall panels, metal gutters, and rain water leaders. Overall building dimensions are 49'-0" long by 32'-6" wide with a 3:12 roof pitch. The design includes four base plate connection details (designated as Baseplate A, B, and C) for column-to-wall connections using anchor bolts. Key notes specify that bolted and mechanical fastener connections must be designed, detailed shop drawings must be submitted, and all exposed concrete requires a rubbed finish. The project is associated with the U.S. Department of Veterans Affairs National Cemetery Administration and references correction of FCA deficiencies.
View the file
Other files
Show 40 more
Latest 50 of 67 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D
C
B
A
1 3
25'-0" 3'
-6
'-0
'-0
'-0
3'
-6
4'-0" 3'-6"
LINE OF ROOF AND
GUTTER ABOVE TYP.
32'-6"
'-0
DOWNSPOUT, TYP.
6" 6"
6" 6"
DS
DS
D
C
B
A
1 3
LINE OF BUILDING
BELOW
3:12
1'-4"
TYP.
T.O.S.
T.O.S.
2% PITCH
SEE SITE PLAN
A B C D
BEYOND
4' -0
"1'-4"
TYP.
BEYOND
T.O.S.
METAL GUTTER
20GA. 1-1/2" GR50
STEEL DECKING, HDG
MC8X20 STEEL
CHANNEL PURLIN, HDG
HSS 6X6X1/4 STEEL
RAFTER, HDG
RAIN WATER LEADER
BLOCKING
1/4" = 1'-0"1 COVERED MATERIAL STORAGE BINS FLOOR PLAN
1/4" = 1'-0"2 COVERED MATERIAL STORAGE BINS ROOF PLAN
1/4" = 1'-0"4 COVERED MATERIAL STORAGE BINS SIDE ELEVATION
1/4" = 1'-0"3 COVERED MATERIAL STORAGE BINS FRONT ELEVATION
1/4" = 1'-0"6 COVERED MATERIAL STORAGE BINS REAR ELEVATION
1/4" = 1'-0"5 COVERED MATERIAL STORAGE BINS SECTION
1 1/2" = 1'-0"10 TYP. GUTTER DETAIL
12'-6" 12'-6"C L C LC L
6'-3" 6'-3" 6'-3"6'-3"C L C L
3 3
3 3
4' -8
4'
-8
4' -8
4' -8
4'
-8
4' -8
4' -8
4'
-8
4' -8
C L
C L C L
C L C L
C L
C L C L
C L C L
6'-3" 6'-3" 6'-3"6'-3"
C L C L
D C B A
'-0
'-0
'-4
4' -0
'-0
3 4"
'-0
EAVE
6' -0
'-1
0"
'-0
3 4"
6' -0
'-1
0"
'-0
3 4"
26'-2"
7" 7"
7" 7" 25'-0"
7" 7"
'-2
7" 7"
PURLINS AT 8 EQ. SPACES
D
C
B
A
1 3
25'-0" 3'
-6
'-0
'-0
'-0
3'
-6
4'-0" 3'-6"
LINE OF ROOF AND
GUTTER ABOVE TYP.
32'-6"
'-0
DOWNSPOUT, TYP.
6" 6"
6" 6"
D
C
B
A
LINE OF BUILDING
BELOW
1/4" = 1'-0"1 COVERED MATERIAL STORAGE BINS FLOOR PLAN
12'-6" 12'-6"C L C LC L
6'-3" 6'-3" 6'-3"6'-3"C L C L
3 3
3 3
4' -8
4'
-8
4' -8
4' -8
4'
-8
4' -8
4' -8
4'
-8
4' -8
C L
C L C L
C L C L
C L
C L C L
C L C L
6'-3" 6'-3" 6'-3"6'-3"
C L C L
26'-2"
7" 7"
7" 7" 25'-0"
7" 7"
'-2
7" 7"
1" = 1'-0"9 COLUMN TO WALL CONNECTION - BASEPLATE "B"
HSS 6x6x1
COLUMN, HDG
CONCRETE WALL
(SEE SHT S-201 FOR
REINFORCEMENT)
1'-2"
1' -2
CO
N
CR
ET
E
W
AL
L
10" SQ. X 5 8" THK.
BASEPLATE
10" SQ. X 5 8" THK.
BASEPLATE, HDG
HSS 6x6x1
COLUMN, HDG
(4) 3/4" ANCHOR
BOLTS, HDG
C L 8"
PLAN VIEW SECTION
1' -0
BO
LT
EM
BE
DE
D 3/4" ANCHOR BOLT,
HDG (TYP.)
MC6X12
COLUMN, HDG
CONCRETE WALL
(SEE SHT S-201 FOR
REINFORCEMENT)
1'-2"
1' -2
CO
N
CR
ET
E
W
AL
L
8" SQ. X 12" THK.
BASEPLATE, HDG
8" SQ. X 12" THK.
BASEPLATE, HDG
MC6x12
COLUMN, HDG
(4) 5/8" ANCHOR
BOLTS, HDG
C L 6"
PLAN VIEW SECTION
1' -0
BO
LT
EM
BE
DE
D
5/8" ANCHOR BOLT,
HDG (TYP.)6"
8"
1" = 1'-0"8 COLUMN TO WALL CONNECTION - BASEPLATE "A"
TYP
4"
2"1
4" PL, HDG
(TYP.)
5"
2"
5/8" ANCHOR
BOLT, HDG (TYP.)
1' -0
BO
LT
EM
BE
DE
D
(4) 5/8" ANCHOR
BOLTS, HDG
PLAN VIEW SECTION
4" PL, HDG
(TYP.)
HSS 6x6x1
COLUMN, HDG
1" = 1'-0"7 COLUMN TO WALL CONNECTION - BASEPLATE "C"
UN
I TED
STATES OF AMER
I C
A
EN
T
OF VETERANS
AFFA
IRS
N C A
ATIONAL
EMETERY
DMINISTRATION
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number Checked Drawn
Location
Date
DRAWING NO.
Dwg. Of
1 2 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
© COPYRIGHT 2022, Walker Federal Services, LLC
PRIME CONSULTANT
Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701
CONSULTANTS
WFS
Correct FCA Deficiencies
CAMP NELSON NATIONAL CEMETERY
833CM3030
ACM LMR
JANUARY 7, 2026
Bid Set
128 NORTHPARK BLVD.,
COVINGTON, LA 70433
ALAL
Engineering
PRINCIPPRINCIP
METAL ROOF DECK, 20GA. 1-1/2" GR50 STEEL,
HDG w/ 4'-3" MAX. SUPPORT SPACING
METAL GUTTER, TYP.
MC6x12 STEEL GIRT WITH BASE PLATE "A", HDG
RAIN WATER LEADER, TYP.
20GA. 1-1/2" METAL WALL PANELS / GIRT SYSTEM,
HDG
HSS 6x6x1
4 STEEL COLUMN WITH BASE PLATE "B",
HDG
CAST IN PLACE CONCRETE WALL, RUBBED FINISH
MC8x20 STEEL CHANNEL, HDG
HSS 6x6x1
4 STEEL RAFTER, HDG
STEEL PURLINS MC 8x20, HDG
LOUVER
PIPE BOLLARD, TYP.
MATERIALS STORAGE BLDG.
FRAMING
S-202
MPM
HSS 6x6x1
4 STEEL COLUMN WITH BASE PLATE "C",
HDG
1. DESIGN AND DETAIL BOLTED AND MECHANICAL
FASTENER CONNECTIONS FOR THE FOLLOWING:
A. COLUMN TO RAFTER
B. PURLIN TO RAFTER
C. DECK TO PURLINS
D. WALL PANEL TO COLUMNS
2. CONNECTIONS MAY BE PINNED. MWFRS
LATERAL LOAD RESISTANCE IS BY FIXED BASE
COLUMNS.
3. SUBMIT DETAILED SHOP DRAWINGS.
4. RUBBED FINISH REQUIRED ON ALL EXPOSED
CONCRETE.
NOTES KEY
RFI - AMMENDMENT 004 10/22/26
| Sheets and Views |
| MATERIAL STORAGE BINS |
File details come from the government source that posted it. Updated .