16-16 - A1-4 - ROOF DEMOLITION AND WORK PLANS.pdf
PDF 169 KB Posted
- Solicitation number
- RFP260305
- Issued by
- Hart County, Kentucky
About this file
This is an architectural drawing set for roof demolition and new work prepared by the Commonwealth of Kentucky's Finance and Administration Cabinet, Department for Facilities Administration, Division of Engineering for the Gateway Urban Campus Professional Services Classroom Center located at 438-440 Scott Street in Covington, Kentucky. The project scope encompasses complete roof demolition including removal of the existing roofing membrane, insulation, RTU units with roof curbs, all pipe penetrations, tile parapet caps, roof openings, rusted sheet metal, sealant, and water-damaged wood elements. Following demolition, the contractor is required to install a new roofing assembly consisting of SBS modified bituminous roofing in white, 1/2-inch high-density polyisocyanurate cover board, 3 inches of polyisocyanurate insulation, and 15/32-inch thick sheathing with roof slopes of 1/4 inch per foot minimum and crickets sloped at 1/2 inch per foot minimum. Additional work includes installation of new gravel stop edges, internal roof drains, vents, a roof hatch, a Solatube skylight, safety railings, and walkway pads, along with repairs to existing exterior walls, re-flashing of scuppers, and re-embedding of masonry as required.
The contractor assumes full responsibility for means and methods of demolition work, all temporary protection, utility coordination and disconnections, permit acquisition and payment, site safety, weather protection for remaining structures, and proper disposal of demolinated materials in compliance with all federal, state, and local codes. All demolished materials become contractor property and must be removed from the site in accordance with municipal, state, and federal regulations. The contractor must conduct a pre-bid site visit to verify existing conditions and immediately report any discrepancies in contract documents to the architect. All infill or replacement work must match existing conditions in materials, construction, and finish, with the contractor guaranteeing all workmanship, materials, and performance for one year from the date of acceptance. The architect and structural engineer must be notified of any pre-existing or concurrent compromised conditions observed in the existing structure-to-remain.
View the file
Other files
Show 40 more
Latest 50 of 80 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1/4" / 12" 1/4" / 12"
EXISTING
ELEVATOR
CAP TO REMAIN
EXISTING ROOF
STRUCTURE
EXISTING ROOF
STRUCTURE
REMOVE EXISTING
RTU AND ROOF CURB
IN ITS ENTIRETY
REMOVE EXISTING
RTU AND ROOF CURB
IN ITS ENTIRETY
REMOVE EXISTING
RTU AND ROOF CURB
IN ITS ENTIRETY
REMOVE EXISTING
RTU AND ROOF CURB
IN ITS ENTIRETY
REMOVE EXISTING ROOFING MEMBRANE
AND INSULATION IN ITS ENTIRETY, REMOVE
AND REPLACE ANY DAMAGED OR WROTTED
EXISTING SHEATHING BOARDS
REMOVE ALL EXISTING PIPE
PENETRATIONS IN THEIR
ENTIRETY (TYPICAL)
REMOVE ALL EXISTING PIPE
PENETRATIONS IN THEIR
ENTIRETY (TYPICAL)
REMOVE ALL EXISTING PIPE
PENETRATIONS IN THEIR
ENTIRETY (TYPICAL)
REMOVE EXISTING ROOF
SURFACE IN ITS ENTIRETY
REMOVE EXISTING ROOF
SURFACE IN ITS ENTIRETY
REMOVE ALL EXISTING
TILE PARAPET CAPS
REMOVE ALL EXISTING
TILE PARAPET CAPS
REMOVE ALL EXISTING
TILE PARAPET CAPS
REMOVE EXISTING ROOF
OPENING, CAP AND CURBS
IN THEIR ENTIRETY
REMOVE EXISTING RUSTED
SHEET METAL, SEALANT &
WATER DAMAGED WOOD
SBS MODIFIED BITUMINOUS ROOFING (WHITE)
OVER 1/2" HIGH DENSITY
POLYISOCYANURATE COVER BOARD
OVER 3 INCHES OF POLYISOCYANURATE
OVER 15/32" THICK SHEATHING
(REFER TO STRUCT. DWGS)
NEW ROOFING ASSEMBLY
SBS MODIFIED BITUMINOUS ROOFING (WHITE)
OVER 1/2" HIGH DENSITY
POLYISOCYANURATE COVER BOARD
OVER 3 INCHES OF POLYISOCYANURATE
OVER 15/32" THICK SHEATHING
(REFER TO STRUCT. DWGS)
NEW ROOFING ASSEMBLY
EXISTING
ELEVATOR
NEW GRAVEL
STOP EDGE
(TYPICAL)
A4.0
A4.0
A4.1
A4.1
A4.0
A4.0
A4.1
A4.1
1 21 21 21
12121
3 3 3 3
12 12 12 12 12
13 13 13
1/2" : 12"
SLOPE
TAPERED
INSULATION
EXISTING SLOPED
STRUCTURE
EXISTING
SLOPED
STRUCTURE
EXISTING
SLOPED
STRUCTURE
EXISTING SLOPED
STRUCTURE
EXISTING SLOPED
STRUCTURE
1/2" : 12"
SLOPE
TAPERED
INSUL.
1/2" : 12" SLOPE
TAPERED
INSULATION
ROOF TOP
OUTSIDE AIR UNIT
AIR COOLED VRV UNITS
AIR COOLED VRV UNITS
18' - 0"
AIR COOLED
VRV UNITS
DEMOLITION PLAN LEGEND
OBJECT TO BE DEMOLISHED
EXISTING OBJECT TO REMAIN
EXISTING WALLS TO REMAIN
DEMOLITION GENERAL NOTES
A. ALL DEMOLITION WORK SHALL BE EXECUTED IN COMPLIANCE WITH ALL
APPLICABLE FEDERAL, STATE, AND LOCAL CODES, LAWS, AND
REGULATIONS.
B. CONTRACTOR IS TO COORDINATE ALL UTILITY DISCONNECTION WORK
PRIOR TO START OF DEMOLITION WORK.
C. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND PAYING
FOR ALL PERMITS, INSPECTIONS, TESTS, ETC. THAT MAY BE REQUIRED
FOR ALL DEMOLITION WORK.
D. CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL MEANS AND METHODS
OF ALL DEMOLITION WORK AND FOR PROVIDING ALL NECESSARY
TEMPORARY PROTECTION AS NECESSARY FOR THE SAFETY AND
STABILITY OF ALL EXISTING ELEMENTS AND STRUCTURE TO REMAIN.
E. CONTRACTOR SHALL MAINTAIN EXISTING ACCESS TO ADJACENT
PROPERTY DURING DEMOLITION/CONSTRUCTION.
F. CONTRACTOR SHALL VISIT THE SITE AND FACILITY TO VERIFY ALL
EXISTING CONDITIONS AND VERIFY THE SCOPE OF WORK INDICATED
BY ALL CONTRACT DOCUMENTS; FAILURE TO REASONABLY
DETERMINE AND/OR ANTICIPATE THE IMPACT OF THE SCOPE OF
WORK ON EXISTING CONDITIONS SHALL NOT BE JUSTIFICATION
FOR ADDITIONAL COMPENSATION; ANY DISCREPANCIES DISCOVERED
IN THE CONTRACT DOCUMENTS SHALL BE IMMEDIATELY REPORTED
TO ARCHITECT PRIOR TO SUBMISSION OF BID.
G. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL EXISTING
FIXTURES AND EQUIPMENT THAT REMAINS WITHIN BUILDING OR ON
SITE, UNLESS NOTED OTHERWISE.
H. UNLESS NOTED OTHERWISE, ALL DEMOLISHED MATERIAL AND
EQUIPMENT IS TO BECOME THE PROPERTY OF THE CONTRACTOR
AND SHALL BE REMOVED FROM THE SITE IN A MANNER THAT IS SAFE
AND COMPLIANT WITH MUNICIPAL, STATE, AND FEDERAL
REGULATIONS; NO ON-SITE SALE OF MATERIALS IS ALLOWED.
I. CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION AGAINST
WEATHER INFILTRATION AND CONSTRUCTION ACTIVITIES FOR ALL
EXISTING CONSTRUCTION TO REMAIN DURING THE DEMOLITION AND
CONSTRUCTION PROCESS TO PREVENT DAMAGE TO EXISTING
FINISHES OR MATERIALS THAT ARE TO REMAIN.
J. ALL DEMOLITION WORK PERFORMED IN EXCESS OF THAT INDICATED
ON PLANS AND ANY DAMAGE TO EXISTING-TO-REMAIN
CONSTRUCTION SHALL BE PATCHED, REPAIRED, AND/OR REPLACED
TO "LIKE-NEW" CONDITION AT CONTRACTOR'S EXPENSE.
K. ALL INFILL OR REPLACEMENT WORK SHALL MATCH EXISTING
CONDITIONS IN MATERIALS, CONSTRUCTION, AND FINISH, UNLESS
SPECIFICALLY NOTED ELSEWHERE IN THE DEMOLITION
DOCUMENTS; MATERIAL NOT SPECIFICALLY SPECIFIED SHALL BE
EQUAL IN QUALITY TO EXISTING MATERIAL OR LIKE KIND;
GUARANTEE ALL WORKMANSHIP, MATERIAL, AND PERFORMANCE FOR
A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE (UNLESS
OTHERWISE NOTED).
L. CONTRACTOR IS RESPONSIBLE FOR DEMOLITION AND REMOVAL OF ALL
COMPONENTS IN SUCH A WAY AS TO NOT DAMAGE OR OTHERWISE
COMPROMISE EXISTING STRUCTURE-TO-REMAIN.
M. NOTIFY ARCHITECT AND STRUCTURAL ENGINEER REGARDING
PRE-EXISTING OR CONCURRENT COMPROMISED CONDITIONS
(INCLUDING EXCESSIVE CORROSION, WARPING, OR DEFLECTION)
THAT IS OBSERVED IN EXISTING STRUCTURE-TO-REMAIN (INCLUDING,
BUT NOT LIMITED TO, STEEL DECK, JOISTS, BEAMS, AND COLUMNS).
NEW WORK - ROOF GENERAL NOTES
A. ALL ROOFING, FLASHING & INSTALLATION TO BE INSTALLED PER ROOFING
MANUFACTURER'S RECOMMENDED STANDARDS.
B. REFER TO ROOF PLAN FOR ROOF SLOPES. ALL ROOF SLOPES TO BE 1/4" PER FOOT MIN.
CRICKETS TO SLOPE 1/2" PER FOOT MIN.
NEW WORK CODED NOTES
1. PRE-FINISHED ALUMINUM CHIMNEY CAP, REFER TO DETAILS.
2. RE-EMBED AND TUCKPOINT LOOSE MASONRY AS REQUIRED.
3. PRE-FINISHED ALUMINUM PARAPET CAP, REFER TO DETAILS.
4. REWORK EXISTING EXTERIOR WALL AFTER REMOVEAL OF EXISTING
ROOFING, AS REQUIRED FOR STRUCTURAL STABILITY, REPLACE ALL
WATER DAMAGED WOOD, WITH P.T. WOOD STUDS AND 3/4"
EXTERIOR GRADE PLYWOOD..
5. PRE-FINISHED ALUMINUM GRAVEL STOP EDGE, REFER TO DETAILS.
6. RE-FLASH EXISTING THRU WALL SCUPPER TO CONDUCTOR HEAD.
7. NEW INTERNAL ROOF DRAIN / OVERFLOW DRAIN COMBO, REFER TO
DETAILS AND MEP DRAWINGS.
8. "SOLATUBE" SKYLIGHT, REFER TO DETAIL 4/A4.0.
9. INFILL EXISTING PORTION OF ROOF AFTER REMOVAL OF EXISTING
ROOF TOP UNITS, REFER TO DETAILS AND STRUCTURAL DRAWINGS.
10. VENT THRU ROOF, REFER TO DETAILS AND MEP DRAWINGS.
11. ROOF HATCH, REFER TO DETAILS.
12. CONTINUE ROOFING MEMBRANE UP AND OVER WALL.
13. ROOFING CRICKET.
14. NEW PRE-FINISHED ALUMINUM CORNER COVER, SECURED TO
EXISTING CORNICE/WALL. SHAPE ALUMINUM EDGE TO MATCH
CORNICE. EXTEND ALUMINUM UP AND UNDER NEW GRAVEL STOP
EDGE. PROVIDE CONTINUOUS SEALANT AROUND ALL EDGES AND
AT ALL RIVITS/CONNECTIONS AND ATTACHMENTS. REPLACE ALL
WATER DAMAGED WOOD MEMBERS WITH 2x P.T. WOOD STUDS AND
3/4" EXTERIOR GRADE PLYWOOD.
15. SAFETY RAILING, BASIS OF DESIGN: KEE SAFETY,NON-PENETRATING
ROOF RAILING SYSTEM, FULLY GALVANIZED, COLOR - GALVANIZED
GREY, WITH KEE GUARD POST WEIGHTED BASE.
16. WALKWAY PADS AS PER ROOFING MANUFACTURER'S
RECOMMENDATION, REFER TO SPECIFICATIONS.
X
C
COMMONWEALTH
T
R E
R
A
H C
I
N K
E
UT
OF
B
3 87
I
R E
G
No.
TS E
NT U
C E
YK T
N E R
D
ER
RB
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DATE
DATE
ENGINEERING
DIVISION OF
AGENCY
AUTHORIZED AGENT
FOR INTENT ONLY
DIV. OF ENGR.
REVIEWED
ENGR. ACCT. NO.
DRAWING NO.
DATE
A&E FILE NO.
CHECKED BY
SHEET DRAWN BY
RECORD DATE
DATEREVISIONS
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES MANAGEMENT
DIVISION OF ENGINEERING
FRANKFORT, KENTUCKY
/5
/2
:5 :5
P
M C
U s e rs
\R H in s o n \D o c u m e n ts
\1
G
C T
C
A b o d e B u il d in g R e n o v a ti o n rh in s o n .r v t
A1.4
ROOF DEMOLITION AND WORK
PLANS
470-C5N5-NC11-01
GATEWAY URBAN CAMPUS
09/25/14
201114.02
BB
REH
PROFESSIONAL SERVICES CLASSROOM CENTER
438-440 Scott St., Covington, KY 41011
SCALE: 1/4" = 1'-0"A1.4
7 ROOF PLAN - DEMOLITION
SCALE: 1/4" = 1'-0"A1.4
8 ROOF PLAN - NEW WORK
NORTH
PLAN
NORTH
PLAN AS-BUILT
12-18-15
RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED IN PART, ON THE BASIS OF INFORMATION COMPILED BY OTHERS. THE ARCHITECT/ENGINEER HAS NOT VERIFIED THE ACCURACY OR COMPLETENESS OF THE INFORMATION, AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS THAT MAY BE
INCORPORATED AS A RESULT OF ERRONEOUS INFORMATION PROVIDED BY OTHERS.