S102.pdf
PDF 119 KB Posted
- Attached to
- Boiler #3 Replacement
- Solicitation number
- 14-223-SOL-00059
About this file
S102
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment_1.pdf | ||
| E301.pdf | ||
| M403.pdf | ||
| M402.pdf | ||
| M103.pdf | ||
| Attachment_J-1_Specifications.pdf | ||
| E101.pdf | ||
| M305.pdf | ||
| M601.pdf | ||
| E401.pdf | ||
| M303.pdf | ||
| M200.pdf | ||
| M306.pdf | ||
| M501.pdf | ||
| M702.pdf | ||
| G100.pdf | ||
| M307.pdf | ||
| M203.pdf | ||
| E102.pdf | ||
| Attachment_J-2_Drawings.pdf | ||
| M202.pdf | ||
| M302.pdf | ||
| M304.pdf | ||
| Attachment_J-4_FDA_Form_3391.pdf | ||
| M401.pdf | ||
| M701.pdf | ||
| M201.pdf | ||
| S101.pdf | ||
| M301.pdf | ||
| M102.pdf | ||
| E201.pdf | ||
| E202.pdf | ||
| Solicitation_14-223-SOL-00059.pdf | ||
| M204.pdf | ||
| Attachment_J-3_General_Decision_Number_AR140125.pdf | ||
| M100.pdf | ||
| M101.pdf | ||
| M104.pdf |
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OOOOOOOO TME, INC.
ER
ENNA
CCCC
RK
A
S -A S GE N I
No. 178
NNNN
TTTT
TTTTRRRRAAAAAAAA TTTT
RRRRPPPP
OOOORRRR
EEEEE IIIIRRRR SSSSGGGGEEE
IIII
FIN FLR
0' - 0"
MEZZANIE
12' - 0"
SECOND FLOOR
24' - 0"
1 1.4 2 2.4 3 3.4 4
EXISTING BEAM TO
BE RELOCATED ABOVE
NEW LOCATION OF EXISTING
BEAM BELOW
EXISTING BEAM EXISTING BEAM EXISTING BEAM
E X
IS
T
IN
G
C O
LU
M
N
E X
IS
T
IN
G
C O
LU
M
N
E X
IS
T
IN
G
C O
LU
M
N
E X
IS
T
IN
G
C O
LU
M
N
E X
IS
T
IN
G
C O
LU
M
N
E X
IS
T
IN
G
C O
LU
M
N
'-0
'-7
/2
(F
IE
LD
V
E R
IF
Y
2'
-4
/2
FIN FLR
0' - 0"
MEZZANIE
12' - 0"
SECOND FLOOR
24' - 0"
1 1.4 2 2.4 3 3.4 4
'-0
2'
-0
(+/-) 10'-8" EXISTING OPNG
12'-0" NEW OPNG
(+/-) 1"
ORIGINAL W12x40
LOCATION
NEW LOCATION FOR EXISTING W12x40
EXISTING BEAM EXISTING BEAM EXISTING BEAM
E X
IS
T
IN
G
C O
LU
M
N
E X
IS
T
IN
G
C O
LU
M
N
E X
IS
T
IN
G
C O
LU
M
N
E X
IS
T
IN
G
C O
LU
M
N
S102
1'-4"
"A"
SECTION "A" SECTION "B"
"B" H
1' -7
CONT BENT PL1/2"
11"
3"
FIELD VERIFY
WIDTH OF
EXISTING BLOCK
CL HSS & SILL
HSS12x4x1/4
EXISTING
WINDOW SILL
EXISTING
WINDOW
PL3/8x9 x 1'-4"
13'-0"
2"
CONT BENT PL
EA SIDE OF OPNG
ATTACH BENT PL TO EXISTING
MASONRY w/ HILTI HIT HY 20
1/2" DIA THREADED HIT-I INSERT
ANCHORS (3 3/8" EMBEDMENT)
@ EVERY BLOCK. CENTERED ON
EXISTING BLOCK
HSS12x4x1/4
EXISTING BLOCK
1'-4"
3/16
3/16
ADJUST DEPENDING ON
WIDTH OF EXISTING BLOCK
ISSUE DATE:
SHEET NUMBER:
PROJECT NUMBER:
5800 EVERGREEN DRIVE
LITTLE ROCK,
ARKANSAS
72205-1757
Phone: (501) 666-6776 Fax: (501) 663-8888 tme@tmecorp.com
SHEET TITLE:
ENGINEER SEAL
CORPORATE SEAL
MARK DATE DESCRIPTION
S102
ELEVATIONS AND DETAILS
03-24-14
01-13-0018
B ui ld in g
B oi le r #3
R ep la ce m en t Je ffe rs on L ab or at or ie s
F oo d an d D ru g
A dm in is tr at io n
N C
T R
R d
Je ffe rs on
, A R
CONSTRUCTION
DOCUMENT
BOILER 3 INSTALLATION NOTES:
1. BEFORE BEGINNING STRUCTURAL WORK, THE CONTRACTOR SHALL FIELD VERIFY EXISTING CONDIITONS AND DIMENSIONS AND SHALL NOTIFY THE STRUCTURAL ENGINEER OF RECORD OF ANY CONDITIONS ENCOUNTERED
CONTRADICTORY TO THOSE SHOWN ON THE STRUCTURAL CONTRACT DOCUMENTS.
2. EXISTING W12x40 STEEL BEAM IS TO BE RELOCATED IN ORDER TO ACCOMODATE NEW OPENING
FOR THE BOILER 3 INSTALLATION.
3. THE NEW LOCATION OF THE BEAM IS SHOWN ON ELEVATION 01/S102.
4. CONTRACTOR TO PROVIDE TEMPORARY BRACING TO COMPENSATE FOR THE REMOVAL OF EXISTING BEAMS DURING CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR THE TEMPORARY BRACING AND/OR SHORING OF THE STRUCTURE DURING CONSTRUCTION. THE STRUCTURE IS NOT STABLE UNTIL ALL ELEMENTS ARE CONNECTED IN PLACE. THE DESIGN ADEQUACY AND SAFETY OF ERECTION BRACING, FORMWORK, SHORING, TEMPORARY SUPPORTS, ETC. AND THE MEANS, METHODS, TECHNIQUES AND SEQUENCE OF CONSTRUCTION ARE SOLE
RESPONIBILITY OF THE CONTRACTOR.
5. THE STRUCTURAL ENGINEER OF RECORD WILL REVIEW THE EXISTING BEAMS AND DECIDE IF IT IS ACCEPTABLE FOR THE EXISTING BEAMS TO BE CONNECTED BACK TO THE EXISTING COLUMNS BEFORE THE DOOR OPENING IS INSTALLED. IF THE EXISTING W12X40 BEAM IS DEEMED UNUSABLE NEW BEAM WILL HAVE TO BE FABRICATED & ERECTED TO REPLACE THE EXISTING BEAM. CONTRACTOR SHALL PROVIDE PRICING FOR NEW MEMBERS IN THE
BASE BID.
6. IF NEW STEEL BEAMS ARE REQUIRED (SEE NOTE 5 ABOVE) WIDE FLANGE SHAPES SHALL BE ASTM A992 GRADE 50.
ALL OTHER MISCELLANEOUS STEEL SHALL BE ASTM A36 UNLESS NOTED OTHERWISE.
7. ALL STRUCTURAL BOLTS CONNECTING STRUCTURAL STEEL SHALL BE ASTM A325 TYPE 1 WITH THREADS ALLOWED IN
THE SHEAR PLANE.
8. CONTRACTOR TO TEMPORARILY BRACE MASONRY WALL ONCE W12x40 IS MOVED FROM ORIGINAL LOCATION.
(BRACE WALL AT ORIGINAL W12x40 LOCATION) MASONRY WALL IS TO BRACED UNTIL W12x40 IS RELOCATED AND LATERAL TIES ARE PROVIDED TO BRACE MASONRY BACK TO W12x40. LATERAL TIES TO CONSIST OF BENT PL1/4x4 x 0'-7" (LLH) THAT IS WELDED TO BOTTOM FLANGE OF EXISTING BEAM AND ATTACHED TO EXISTING MASONRY w/ HILTI HY20 1/2" DIA THREADED HIT-1 INSERT ANCHORS (3 3/8" EMBEDMENT) TO MATCH EXISTING
LATERAL TIE SPACING.
BOILER 3 INSTALLATION
1/4" = 1'-0"
02 FRAMING ELEVATION ALONG GRID G
BOILER 3 INSTALLATION
1/4" = 1'-0"
01 FRAMING ELEVATION ALONG GRID H
FRAMING ALONG GRID G:
1. BEFORE BEGINNING STRUCTURAL WORK, THE CONTRACTOR SHALL FIELD VERIFY EXISTING CONDIITONS AND DIMENSIONS AND SHALL NOTIFY THE STRUCTURAL ENGINEER OF RECORD OF ANY CONDITIONS ENCOUNTERED
CONTRADICTORY TO THOSE SHOWN ON THE STRUCTURAL CONTRACT DOCUMENTS.
2. EXISTING LOW BEAMS AT ELEVATION (+/-)12'-7 1/2" (FIELD VERIFY) ARE TO BE RELOCATED IN ORDER TO ACCOMODATE
NEW OPENING FOR BOILER INSTALLATION.
3. SET BOTTOM OF BEAMS 2'-0" ABOVE NEW OPENING.
4. ADJUST ANGLE BRACING AS REQUIRED TO FIT NEW BRACING ALIGNMENT.
5. CONTRACTOR TO PROVIDE TEMPORARY BRACING TO COMPENSATE FOR THE REMOVAL OF EXISTING BEAMS DURING CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR THE TEMPORARY BRACING AND/OR SHORING OF THE STRUCTURE DURING CONSTRUCTION. THE STRUCTURE IS NOT STABLE UNTIL ALL ELEMENTS ARE CONNECTED IN PLACE. THE DESIGN ADEQUACY AND SAFETY OF ERECTION BRACING, FORMWORK, SHORING, TEMPORARY SUPPORTS, ETC. AND THE MEANS, METHODS, TECHNIQUES AND SEQUENCE OF CONSTRUCTION ARE SOLE
RESPONIBILITY OF THE CONTRACTOR.
6. THE STRUCTURAL ENGINEER OF RECORD WILL REVIEW THE EXISTING BEAMS AND DECIDE IF IT IS ACCEPTABLE FOR THE EXISTING BEAMS TO BE CONNECTED BACK TO THE EXISTING COLUMNS BEFORE THE DOOR OPENING IS INSTALLED. IF THE EXISTING W12X40 BEAM & ANGLE BRACING ARE DEEMED UNUSABLE NEW BEAMS WILL HAVE TO BE FABRICATED & ERECTED TO REPLACE THE EXISTING BEAMS. CONTRACTOR SHALL PROVIDE PRICING FOR
NEW MEMBERS IN THE BASE BID.
7. IF NEW STEEL BEAMS ARE REQUIRED (SEE NOTE 6 ABOVE) WIDE FLANGE SHAPES SHALL BE ASTM A992 GRADE 50.
ALL OTHER MISCELLANEOUS STEEL SHALL BE ASTM A36 UNLESS NOTED OTHERWISE.
8. ALL STRUCTURAL BOLTS CONNECTING STRUCTURAL STEEL SHALL BE ASTM A325 TYPE 1 WITH THREADS ALLOWED IN
THE SHEAR PLANE.
1" = 1'-0"
03 DETAIL AT MASONRY WALL SUPPORT