M101.pdf

PDF 917 KB Posted

Attached to
Boiler #3 Replacement
Solicitation number
14-223-SOL-00059
Issued by

About this file

M101

View the file

Other files

File Type Posted
Amendment_1.pdf PDF
M303.pdf PDF
M200.pdf PDF
M306.pdf PDF
M501.pdf PDF
S102.pdf PDF
M702.pdf PDF
G100.pdf PDF
M307.pdf PDF
M203.pdf PDF
E102.pdf PDF
Attachment_J-2_Drawings.pdf PDF
M202.pdf PDF
M302.pdf PDF
M304.pdf PDF
Attachment_J-4_FDA_Form_3391.pdf PDF
M401.pdf PDF
M701.pdf PDF
E301.pdf PDF
M403.pdf PDF
M402.pdf PDF
M103.pdf PDF
Attachment_J-1_Specifications.pdf PDF
E101.pdf PDF
M305.pdf PDF
M601.pdf PDF
E401.pdf PDF
M201.pdf PDF
S101.pdf PDF
M301.pdf PDF
M102.pdf PDF
E201.pdf PDF
E202.pdf PDF
Solicitation_14-223-SOL-00059.pdf PDF
M204.pdf PDF
Attachment_J-3_General_Decision_Number_AR140125.pdf PDF
M100.pdf PDF
M104.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXISTING

WATER

TUBE

BOILER

#1

CONTROL

PANEL

EXISTING

AIR

STORAGE

TANK

EXISTING

AIR

COMPRESSOR

EXISTING

WATER

SOFTENER

TANK

EXISTING

WATER

SOFTENER

TANK

EXISTING

WATER

SOFTENER

TANK

EXISTING

BOILER

FEED

PUMP

EXISTING

BOILER

FEED

PUMP

EXISTING

BOILER

FEED

PUMP

EXISTING

CHEMICAL

TREATMENT

CPS-1

BDHX-1

EXISTING WATER

TUBE

BOILER #1

EXISTING 2" FUEL

OIL PIPING FOS/FOR

1" DCW

4" SR 2"

F

O S

FOS-1

CST-1

4" DCW

EXISTING

FIRE TUBE

BOILER #2

EXISTING

FIRE TUBE

BOILER #1

3" BD

3" S15

6" S15

BS-1

1" DCW

4" DCW

3" NG

4 3.4

2.4 1.4 1

H

E

D

B

A

EXISTING FUEL OIL SUPPLY PUMP TO BE REMOVED.

EXISTING WATER TUBE BOILER #1 AND ASSOCIATED

EQUIPMENT AND PIPING TO BE REMOVED UNDER

BOILER #3 INSTALLATION.

EXISTING 4" BOILER FEED WATER PIPING TO BE

REMOVED.

EXISTING STRUCTURAL SUPPORT COLUMN TO

REMAIN. PROTECT AND SUPPORT DURING BOILER

DEMOLITION.

REMOVE EXISTING BLOWDOWN PIPING.

EXISTING NATURAL GAS PIPING TO BE REMOVED.

EXISTING FUEL OIL PIPING TO BE REMOVED.

EXISTING STEAM CONDENSATE RETURN TO BE

REMOVED.

EXISTING WATER SOFTENER SYSTEM TO BE

REMOVED AND REPLACED WITH NEW. THIS IS

ADDITIVE OPTION #5.

ALL EXISTING PIPING TO WATER SOFTER TO BE

REMOVED,

EXISTING 6" BD TO BE REMOVED.

ALL EXISTING PIPING TO BE REMOVED.

REMOVE ABANDONED PIPING ASSOCIATED WITH

EXISTING FEED WATER SYSTEM. THIS IS ADDITIVE

OPTION #2

REMOVE EXISTING FEEDWATER PUMPS AND ALL

ASSOCIATED FEEDWATER PIPING, CONCRETE,

ETC., PATCH FLOOR AND SMOOTH FINISHED

SURFACE. THIS IS ADDITIVE OPTION #2

REMOVE EXISTING FEEDWATER PIPING IN TRENCH.

THIS IS ADDITIVE OPTION #3

REMOVE EXISTING FUEL OIL DAY TANK.

ALL PIPING ASSOCIATED WITH FUEL OIL DAY TANK

TO BE REMOVED. DISPOSE OF FUEL OIL IN

ACCORDANCE OF STATE REQUIREMENTS, SEE

SPEC FOR GENERATOR REMOVAL.

EXISTING LOUVER TO BE REMOVED. SEE

STRUCTURAL DRAWINGS.

M303

2" FOR

2" FOR

1 1/2" BD

4" BFW

EXISTING 2" DRAIN UP

EXISTING 1" DRAIN

UP AND DN

EXISTING 1" COLD WATER

UP AND DN

4" DCW

6" SR

DEMOLITION KEYED NOTES:

6" SR

4" NG

3" BD

2" FOR

2" FOR

2" FOR

2" FOR 2" FOR

72" FOR

2" FOR 7

1 1/2" SR

1 1/2" SR

EXISTING 6" VENT

1" DCW 4" V

2" FOR 7

4" SR

2" S100 2" FOS

4" NG6" NG

6" SR

UP

GENERAL DEMOLITION NOTES:

1. ALL EXISTING EQUIPMENT, PIPING, VALVES TO

REMAIN UNLESS OTHERWISE NOTED.

EXISTING

EXISTING

FOP-1FOP-2

EXISTINGEXISTING

EXISTING

9 9 9

6" BD DOWN TO

BLOWNDOWN

TANK

6" BD

EXISTING

CONDENSATE

RETURN

PUMPS

ADDITIVE OPTIONS

OPTION #1 REMOVE ABANDONED DEAERATOR TANK AND ALL ASSOCIATED PIPING.

OPTION #2

OPTION #3

OPTION #4

REMOVE EXISTING FEEDWATER PUMPS AND ALL ASSOCIATED FEEDWATER PIPING ABOVE SLAB.

OPTION #5

OPTION #6

REMOVE ALL EXISTING FEEDWATER PIPING IN TRENCH.

NEW STEAM UNIT HEATERS AND ALL S15 STEAM PIPING FEEDING NEW STEAM UNIT HEATERS.

NEW WATER SOFTNER SYSTEM, COMPLETE WITH PIPING ABD CONTROLS.

NEW EMERGENCY GENERARTOR.

OPTION #7 NEW HVAC PIPING TO CONNECT EMERGENCY BOILER.

ISSUE DATE:

SHEET NUMBER:

PROJECT NUMBER:

5800 EVERGREEN DRIVE

LITTLE ROCK,

ARKANSAS

72205-1757

Phone: (501) 666-6776 Fax: (501) 663-8888 tme@tmecorp.com

SHEET TITLE:

ENGINEER SEAL

CORPORATE SEAL

MARK DATE DESCRIPTION

M101

BOILER #3 INSTALLATION -

FIRST FLOOR PLAN -

MECHANICAL DEMOLITION

03-24-14

01-13-0018

B ui ld in g

B oi le r #3

R ep la ce m en t Je ffe rs on L ab or at or ie s

F oo d an d D ru g

A dm in is tr at io n

N C

T R

R d

Je ffe rs on

, A R

CONSTRUCTION

DOCUMENT

1/4" = 1’−0"

BOILER #3 INSTALLATION − FIRST FLOOR PLAN − MECHANICAL DEMOLITION

GENERAL NOTE:

CONTRACTOR SHALL NOT CONDUCT ANY WORK THAT WILL SHUTDOWN BOILER #1 OR #2 WHILE WORKING ON BOILER #3. ANY WORK ON EXISTING BOILERS SHALL BE SCHEDULED IN ADVANCE SO THAT A MINIMUM OF TWO

BOILERS ARE ALWAYS OPERATIONAL AND AVAILABLE.

File details come from the government source that posted it. Updated .