M403.pdf
PDF 735 KB Posted
- Attached to
- Boiler #3 Replacement
- Solicitation number
- 14-223-SOL-00059
About this file
M403
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment_1.pdf | ||
| M303.pdf | ||
| M200.pdf | ||
| M306.pdf | ||
| M501.pdf | ||
| S102.pdf | ||
| E301.pdf | ||
| M402.pdf | ||
| M103.pdf | ||
| Attachment_J-1_Specifications.pdf | ||
| E101.pdf | ||
| M305.pdf | ||
| M601.pdf | ||
| E401.pdf | ||
| M702.pdf | ||
| G100.pdf | ||
| M307.pdf | ||
| M203.pdf | ||
| E102.pdf | ||
| Attachment_J-2_Drawings.pdf | ||
| M202.pdf | ||
| M302.pdf | ||
| M304.pdf | ||
| Attachment_J-4_FDA_Form_3391.pdf | ||
| M401.pdf | ||
| M701.pdf | ||
| M201.pdf | ||
| S101.pdf | ||
| M301.pdf | ||
| M102.pdf | ||
| E201.pdf | ||
| E202.pdf | ||
| Solicitation_14-223-SOL-00059.pdf | ||
| M204.pdf | ||
| Attachment_J-3_General_Decision_Number_AR140125.pdf | ||
| M100.pdf | ||
| M101.pdf | ||
| M104.pdf |
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
PLAN
SYMBOL
SARCO 13 WS
ARMSTRONG NO
1-AV WHEATLEY
AR 0075
3/4" BALL VALVE
1/4"
NPS
CHECK
VALVE
UNION
1/4" BALL
VALVE
LOCATE IN
ACCESSIBLE
POSITION
TO FLOOR
DRAIN
1/4"
NPS
PLAN
SYMBOL
H
AUTOMATIC
AIR VENT
MANUAL OR HAND OPERATED AIR
VENT
UNION
A.S.M.E. RELIEF
VALVE
RELIEF LINE TO FLOOR
DRAIN REFER TO PLANS
FOR ROUTING OF
RELIEF LINE
METERING POINT
TWO 90 DEGREE ELLS OUT OF PLANE
METERING POINT
5xDIA.
5xDIA.
2xDIA.
2xDIA.
METERING POINT
METERING POINT
METERING POINT
5xDIA.
5xDIA.
5xDIA.
2xDIA.
2xDIA.
2xDIA.
FLUID PIPE
FLANGED FLOW TUBE
FLUID PIPE, FLOW MUST BE
HORIZONTAL OR UPWARDS
1.5" TO 8" PIPE SIZE
9xDIA.
REGULATOR, GLOBE,
BUTTERFLY PARTIALLY
CLOSED GATE OR PLUG
VALVE
TERMINAL
BOX
TERMINAL
BOX
STRAIGHT RUN REQUIREMENTS
PLANELEVATION
PIPE INSULATION
PIPE SLEEVE WITH
1" EXTENSION ABOVE
FLOOR LINE
BOLT
BOTTOM OR UNDER SLAB
PIPE RISER CLAMP REQUIRED
AT ANCHOR POINTS ONLY
BOLT
GRINNELL FIGURE 108
SPLIT RING CLAMP
PIPE RISER
PIPE INSULATION
FLOOR SLAB
PIPE RISER
PIPE SLEEVE
FIRE STOPPING
REFER TO DETAIL
APPLY SEALANT IN WET AREAS
GRINNELL FIGURE 261 RISER CLAMP
EXTERIOR PIPING
SHALL BE INSULATED
AND COVERED WITH
ALUMINUM JACKET
16 GAUGE
SLEEVE
12" LONG
2" SCHEDULE
40 PIPE
SUPPORT
BOLT TO EXISTING
STRUCTURE - 3/8"
MINIMUM BOLT DIA.
MEZZANINE
STRUCTURE
8"x8"x3/8"
STEEL BASE
PLATE
CONTINUOUS WELD
CONTINUOUS WELD
CELLULAR GLASS HIGH DENSITY
INSULATION BETWEEN PIPE AND
SADDLE, ONE THIRD OF
CIRCUMFERENCE
14" STEAM
HEADER
PIPE INSULATION
WELD SADDLE TO PIPE
ADJUSTABLE ROLLER HANGER
SADDLE INSTALLED FOR
STEAM, STEAM
RETURN AND
FEED WATER PIPING
"HOT" PIPING INCLUDING
BUT NOT LIMITED TO:
STEAM SUPPLY AND RETURN
NUT
ALL THREADED ROD - SEE SPECIFICATION FOR SIZE
JAMB NUT
GRINNEL FIGURE
181 STEEL YOKE
PIPE ROLL
ALL THREADED ROD - SEE SPECIFICATION FOR SIZE
ADJUSTABLE CLEVIS HANGER
PIPING INCLUDING HEATING
HOT WATER, CHILLED WATER,
DOMESTIC WATER, REFRIGERANT
VAPOR, ETC..
PIPE INSULATION
TREATED WOOD BLOCKING
18 GAUGE INSULATION SHIELD
16 GAUGE FOR 6" AND LARGER
PIPE SIZES
VAPOR BARRIER
NUT
JAMB NUT
GRINNEL FIGURE
260 CLEVIS
HANGER
PIPING INCLUDING HEATING
HOT WATER, CHILLED WATER,
DOMESTIC WATER, REFRIGERANT
VAPOR, ETC..
18 GAUGE INSULATION SHIELD
16 GAUGE FOR 6" AND LARGER
PIPE SIZES
ALL THREADED ROD - SEE SPECIFICATION FOR SIZE
ADJUSTABLE CLEVIS HANGER
CELLULAR GLASS HIGH
COMPRESSIVE STRENGTH
INSULATION UNDER SADDLE
VAPOR BARRIER
PIPE INSULATION
NUT
JAMB NUT
GRINNEL FIGURE
260 CLEVIS
HANGER
1" MAX.
PIPE INSULATION
STAINLESS STEEL
BANDS OR CLAMPS
INSTALL INSULATION SHIELD
AND INSERT FOR ALL PIPING
(8" MINIMUM)
1/2" DIAMETER ALL
THREADED ROD WITH 36
MAXIMUM SPACING ON EACH
CHANNEL / UNISTRUT
1-5/8"x1-5/8"
CHANNEL 0R
2"x2"x1/4" ANGLE
ROOF
METAL PITCH PAN
TREATED WOOD BLOCKING
90 DEGREE ELL
90 DEGREE ELL
36" MINIMUM
MATCH ROOFING
MATERIAL AND EXTEND
10" ABOVE ROOF
GRANULAR BASE
FLASHING
NON-HARDENING SEALANT
STAINLESS STEEL PIPE CLAMP
STORM COLLAR
3 PLY FIBERGLASS
ROOFING FELT
SEALED WITH
STEEP ASPHALT
TREATED WOOD BLOCKING
METAL PITCH PAN
GRANULAR BASE FLASHING
ROOF
3 PLY FIBERGLASS
ROOFING FELT SEALED
WITH STEEP ASPHALT
MATCH ROOFING
MATERIAL AND EXTEND
10" ABOVE ROOF
STORM COLLAR
STAINLESS STEEL PIPE CLAMP
NON-HARDENING SEALANT
RESIN TANK
RESIN TANK
BRINE TANK
OUTLET ISOLATION VALVE
INLET
ISOLATION
VALVE
BYPASS VALVE (N.C.)
IN-LINE
FLOW
METER
PRESSURE
GAUGE
PRESSURE
GAUGE
INLET
ISOLATION
VALVE
OUTLET
ISOLATION
VALVE
BRINE LINE TUBING
BRINE
CONTROL
VALVE
4"DCW
4"SCW
NEW
ISOLATION
VALVE
PROVIDED BY
CONTRACTOR
CONNECT TO
EXISTING DCW LINE
2"DRAIN
TFD
PROVIDE A NORMALLY CLOSED
BYPASS VALVE FROM DCW PIPE
TO SCW PIPE DOWNSTREAM OF
WATER SOFTENER FOR DOWNTIME
AND MAINTENANCE.
ISSUE DATE:
SHEET NUMBER:
PROJECT NUMBER:
5800 EVERGREEN DRIVE
LITTLE ROCK,
ARKANSAS
72205-1757
Phone: (501) 666-6776 Fax: (501) 663-8888 tme@tmecorp.com
SHEET TITLE:
ENGINEER SEAL
CORPORATE SEAL
MARK DATE DESCRIPTION
M403
DETAILS - MECHANICAL
03-24-14
01-13-0018
B ui ld in g
B oi le r #3
R ep la ce m en t Je ffe rs on L ab or at or ie s
F oo d an d D ru g
A dm in is tr at io n
N C
T R
R d
Je ffe rs on
, A R
CONSTRUCTION
DOCUMENT
NOT TO SCALE
AIR ELIMINATOR DETAIL
NOT TO SCALE
WATER RELIEF VALVE DETAIL
NOT TO SCALE
MAGNETIC FLOW METER DETAIL
NOT TO SCALE
PIPE RISER SUPPORT/ANCHOR DETAIL
NOT TO SCALE
STEAM HEADER STANCHION DETAIL
NOT TO SCALE
ROLLER PIPE HANGER DETAIL
NOT TO SCALE
CLEVIS PIPE HANGER DETAIL 1
NOT TO SCALE
CLEVIS PIPE HANGER DETAIL 2
NOT TO SCALE
TRAPEZE PIPE HANGER DETAIL
NOT TO SCALE
STEAM VENT THRU ROOF
NOT TO SCALE
PIPE PENETRATION THRU ROOF
WATER SOFTENER DETAIL