Boiler #3 Replacement
Solicitation number
14-223-SOL-00059
Issued by

About this file

M403

View the file

Other files

File Type Posted
Amendment_1.pdf PDF
M303.pdf PDF
M200.pdf PDF
M306.pdf PDF
M501.pdf PDF
S102.pdf PDF
E301.pdf PDF
M402.pdf PDF
M103.pdf PDF
Attachment_J-1_Specifications.pdf PDF
E101.pdf PDF
M305.pdf PDF
M601.pdf PDF
E401.pdf PDF
M702.pdf PDF
G100.pdf PDF
M307.pdf PDF
M203.pdf PDF
E102.pdf PDF
Attachment_J-2_Drawings.pdf PDF
M202.pdf PDF
M302.pdf PDF
M304.pdf PDF
Attachment_J-4_FDA_Form_3391.pdf PDF
M401.pdf PDF
M701.pdf PDF
M201.pdf PDF
S101.pdf PDF
M301.pdf PDF
M102.pdf PDF
E201.pdf PDF
E202.pdf PDF
Solicitation_14-223-SOL-00059.pdf PDF
M204.pdf PDF
Attachment_J-3_General_Decision_Number_AR140125.pdf PDF
M100.pdf PDF
M101.pdf PDF
M104.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

PLAN

SYMBOL

SARCO 13 WS

ARMSTRONG NO

1-AV WHEATLEY

AR 0075

3/4" BALL VALVE

1/4"

NPS

CHECK

VALVE

UNION

1/4" BALL

VALVE

LOCATE IN

ACCESSIBLE

POSITION

TO FLOOR

DRAIN

1/4"

NPS

PLAN

SYMBOL

H

AUTOMATIC

AIR VENT

MANUAL OR HAND OPERATED AIR

VENT

UNION

A.S.M.E. RELIEF

VALVE

RELIEF LINE TO FLOOR

DRAIN REFER TO PLANS

FOR ROUTING OF

RELIEF LINE

METERING POINT

TWO 90 DEGREE ELLS OUT OF PLANE

METERING POINT

5xDIA.

5xDIA.

2xDIA.

2xDIA.

METERING POINT

METERING POINT

METERING POINT

5xDIA.

5xDIA.

5xDIA.

2xDIA.

2xDIA.

2xDIA.

FLUID PIPE

FLANGED FLOW TUBE

FLUID PIPE, FLOW MUST BE

HORIZONTAL OR UPWARDS

1.5" TO 8" PIPE SIZE

9xDIA.

REGULATOR, GLOBE,

BUTTERFLY PARTIALLY

CLOSED GATE OR PLUG

VALVE

TERMINAL

BOX

TERMINAL

BOX

STRAIGHT RUN REQUIREMENTS

PLANELEVATION

PIPE INSULATION

PIPE SLEEVE WITH

1" EXTENSION ABOVE

FLOOR LINE

BOLT

BOTTOM OR UNDER SLAB

PIPE RISER CLAMP REQUIRED

AT ANCHOR POINTS ONLY

BOLT

GRINNELL FIGURE 108

SPLIT RING CLAMP

PIPE RISER

PIPE INSULATION

FLOOR SLAB

PIPE RISER

PIPE SLEEVE

FIRE STOPPING

REFER TO DETAIL

APPLY SEALANT IN WET AREAS

GRINNELL FIGURE 261 RISER CLAMP

EXTERIOR PIPING

SHALL BE INSULATED

AND COVERED WITH

ALUMINUM JACKET

16 GAUGE

SLEEVE

12" LONG

2" SCHEDULE

40 PIPE

SUPPORT

BOLT TO EXISTING

STRUCTURE - 3/8"

MINIMUM BOLT DIA.

MEZZANINE

STRUCTURE

8"x8"x3/8"

STEEL BASE

PLATE

CONTINUOUS WELD

CONTINUOUS WELD

CELLULAR GLASS HIGH DENSITY

INSULATION BETWEEN PIPE AND

SADDLE, ONE THIRD OF

CIRCUMFERENCE

14" STEAM

HEADER

PIPE INSULATION

WELD SADDLE TO PIPE

ADJUSTABLE ROLLER HANGER

SADDLE INSTALLED FOR

STEAM, STEAM

RETURN AND

FEED WATER PIPING

"HOT" PIPING INCLUDING

BUT NOT LIMITED TO:

STEAM SUPPLY AND RETURN

NUT

ALL THREADED ROD - SEE SPECIFICATION FOR SIZE

JAMB NUT

GRINNEL FIGURE

181 STEEL YOKE

PIPE ROLL

ALL THREADED ROD - SEE SPECIFICATION FOR SIZE

ADJUSTABLE CLEVIS HANGER

PIPING INCLUDING HEATING

HOT WATER, CHILLED WATER,

DOMESTIC WATER, REFRIGERANT

VAPOR, ETC..

PIPE INSULATION

TREATED WOOD BLOCKING

18 GAUGE INSULATION SHIELD

16 GAUGE FOR 6" AND LARGER

PIPE SIZES

VAPOR BARRIER

NUT

JAMB NUT

GRINNEL FIGURE

260 CLEVIS

HANGER

PIPING INCLUDING HEATING

HOT WATER, CHILLED WATER,

DOMESTIC WATER, REFRIGERANT

VAPOR, ETC..

18 GAUGE INSULATION SHIELD

16 GAUGE FOR 6" AND LARGER

PIPE SIZES

ALL THREADED ROD - SEE SPECIFICATION FOR SIZE

ADJUSTABLE CLEVIS HANGER

CELLULAR GLASS HIGH

COMPRESSIVE STRENGTH

INSULATION UNDER SADDLE

VAPOR BARRIER

PIPE INSULATION

NUT

JAMB NUT

GRINNEL FIGURE

260 CLEVIS

HANGER

1" MAX.

PIPE INSULATION

STAINLESS STEEL

BANDS OR CLAMPS

INSTALL INSULATION SHIELD

AND INSERT FOR ALL PIPING

(8" MINIMUM)

1/2" DIAMETER ALL

THREADED ROD WITH 36

MAXIMUM SPACING ON EACH

CHANNEL / UNISTRUT

1-5/8"x1-5/8"

CHANNEL 0R

2"x2"x1/4" ANGLE

ROOF

METAL PITCH PAN

TREATED WOOD BLOCKING

90 DEGREE ELL

90 DEGREE ELL

36" MINIMUM

MATCH ROOFING

MATERIAL AND EXTEND

10" ABOVE ROOF

GRANULAR BASE

FLASHING

NON-HARDENING SEALANT

STAINLESS STEEL PIPE CLAMP

STORM COLLAR

3 PLY FIBERGLASS

ROOFING FELT

SEALED WITH

STEEP ASPHALT

TREATED WOOD BLOCKING

METAL PITCH PAN

GRANULAR BASE FLASHING

ROOF

3 PLY FIBERGLASS

ROOFING FELT SEALED

WITH STEEP ASPHALT

MATCH ROOFING

MATERIAL AND EXTEND

10" ABOVE ROOF

STORM COLLAR

STAINLESS STEEL PIPE CLAMP

NON-HARDENING SEALANT

RESIN TANK

RESIN TANK

BRINE TANK

OUTLET ISOLATION VALVE

INLET

ISOLATION

VALVE

BYPASS VALVE (N.C.)

IN-LINE

FLOW

METER

PRESSURE

GAUGE

PRESSURE

GAUGE

INLET

ISOLATION

VALVE

OUTLET

ISOLATION

VALVE

BRINE LINE TUBING

BRINE

CONTROL

VALVE

4"DCW

4"SCW

NEW

ISOLATION

VALVE

PROVIDED BY

CONTRACTOR

CONNECT TO

EXISTING DCW LINE

2"DRAIN

TFD

PROVIDE A NORMALLY CLOSED

BYPASS VALVE FROM DCW PIPE

TO SCW PIPE DOWNSTREAM OF

WATER SOFTENER FOR DOWNTIME

AND MAINTENANCE.

ISSUE DATE:

SHEET NUMBER:

PROJECT NUMBER:

5800 EVERGREEN DRIVE

LITTLE ROCK,

ARKANSAS

72205-1757

Phone: (501) 666-6776 Fax: (501) 663-8888 tme@tmecorp.com

SHEET TITLE:

ENGINEER SEAL

CORPORATE SEAL

MARK DATE DESCRIPTION

M403

DETAILS - MECHANICAL

03-24-14

01-13-0018

B ui ld in g

B oi le r #3

R ep la ce m en t Je ffe rs on L ab or at or ie s

F oo d an d D ru g

A dm in is tr at io n

N C

T R

R d

Je ffe rs on

, A R

CONSTRUCTION

DOCUMENT

NOT TO SCALE

AIR ELIMINATOR DETAIL

NOT TO SCALE

WATER RELIEF VALVE DETAIL

NOT TO SCALE

MAGNETIC FLOW METER DETAIL

NOT TO SCALE

PIPE RISER SUPPORT/ANCHOR DETAIL

NOT TO SCALE

STEAM HEADER STANCHION DETAIL

NOT TO SCALE

ROLLER PIPE HANGER DETAIL

NOT TO SCALE

CLEVIS PIPE HANGER DETAIL 1

NOT TO SCALE

CLEVIS PIPE HANGER DETAIL 2

NOT TO SCALE

TRAPEZE PIPE HANGER DETAIL

NOT TO SCALE

STEAM VENT THRU ROOF

NOT TO SCALE

PIPE PENETRATION THRU ROOF

WATER SOFTENER DETAIL