14-15 - A1-3 - THIRD FLOOR DEMOLITION AND NEW WORK PLANS.pdf
PDF 327 KB Posted
- Solicitation number
- RFP260305
- Issued by
- Hart County, Kentucky
About this file
This is an architectural drawing document prepared by the Commonwealth of Kentucky's Department for Facilities Management, Division of Engineering, for the Gateway Urban Campus project located at 438-440 Scott Street, Covington, Kentucky 41011. The document presents the third floor demolition and new work plans for the Professional Services Classroom Center, showing both demolition and construction scope on a single sheet with North-oriented floor plans at 1/4" = 1'-0" scale. The project includes comprehensive demolition work such as removal of wall partitions, doors, frames, the existing stairwell (Stair D3), portions of floor and joists for new HVAC chase, existing ceiling systems with bulkheads and fixtures, carpet, and raised flooring, along with masonry repair work including removal of existing fire escapes and patching of masonry walls. The new work encompasses construction of multiple spaces including five client massage rooms (301A-E), clinical lab, office, storage, linens room, corridors, restrooms, lobby, and support spaces with new wall framing, gypsum board, windows, doors, ceiling systems including Solatube skylights, flooring, and finishes. The document was approved for program concept only and includes detailed general notes for both demolition and new work that establish contractor responsibilities for code compliance, utility coordination, site verification, existing condition protection, and quality standards.
The drawing establishes that the contractor is solely responsible for all means and methods of demolition work, temporary protection, and obtaining all required permits and inspections at the contractor's expense. All demolished materials become contractor property for removal and disposal in compliance with municipal, state, and federal regulations. The contractor must guarantee all infill, replacement, and repair work to match existing conditions in materials, construction, and finish with one-year warranty from acceptance date. Any work performed in excess of plans or damage to existing-to-remain construction must be repaired to "like-new" condition at the contractor's expense. The document requires the contractor to visit the site to verify existing conditions and discrepancies in contract documents must be reported to the architect prior to bid submission. Record drawings notation indicates the plans were prepared as-built and dated 12-18-15, with the original drawing prepared on 09/25/14 with drawing number A1.3 and file number 201114.02.
View the file
Other files
Show 40 more
Latest 50 of 80 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLIENT MASSAGE
301D
CLIENT MASSAGE
301E
CLIENT MASSAGE
301C
CLIENT MASSAGE
301B
CLIENT MASSAGE
301A
121110987
6 5 4 3 2 1
OFFICE
302C
STORAGE
STAIR
D3
MASSAGE
CLINICAL LAB
BRANDING WALL
WOMEN
10' - 0" (TYP.)
DOWN TO
2ND FLOOR
D O
W N
T O
N
D F
L O
O R
LOBBY
HARDWOOD
CORRIDOR
MEN
A4.0
A4.0
A4.1
A4.1
G
A4.0
A4.0
EXISTING STAIR
C3
LINENS
301F
CORRIDOR
300A
CLOSET
EXISTING
ELEVATOR
E
A4.1
A4.1
HVAC
302A
ROOF ACCESS
302B
906A
906A
906A
906A
906A
906A
906A
906A
906A
906RA906RA
901RA
906A
906A
906A906A
906A
906A
906A
906A
906A
906A
906A
906A
906A
906A
906A
906A
906A
906A
923A
7 6 6
6 5
S0
7 7
7666666666
3 3
3 3
3 3
3 3
3 3
10' - 0" (TYP.)
4 4
301D
301E
301C
301B 301A
C3
D3
302C
12' - 0" 4' - 8" 2' - 3" 10' - 8" 12' - 3" 16' - 7 1/2"
16' - 6" 9' - 0" 8' - 11"
45.00°
A L
IG
N
2' - 0"
9' - 0"
A6.0
A6.0
A6.0
/8
/8
2' - 10 1/4" 5' - 11 1/4" +/- 8' - 11"
/2
/8
2' - 4 1/2" 9' - 4 3/8"
/8
28' - 3" 4' - 8" 4' - 0" 4" 6' - 3" 8' - 9" 3 1/2" 4' - 0" 10' - 5 1/8"
9 1/2" 1' - 2"
5"
10"
A6.0
A6.0
A6.0
A6.0
30O.H.
A6.0
A6.1
A6.1
A5.0
A5.2
/8
/8
/8
/4
/8
A5.2
A5.2
A5.2
A5.2
F
E Q
E Q
F
906A906A906A923
923A
906A
923A
115.0 0°
302B302A
923A
12 12
A6.0
A6.1
15A
/4
/4
A5.2
PR-012r2
36" min.
PLASTER/INSULATION COLLAPED
DURING DEMOLITION, AREA WAS
PREPARED WITH NEW INSULATION
AND GYPSUM BOARD, PAINTED
REMOVE WALL PARTITIONS, DOORS
& FRAMES FULL HEIGHT (TYPICAL),
SALVAGE ALL WOOD BASEBOARDS
AND SHOE MOLDING FOR REUSE
REMOVE WALL PARTITIONS, DOORS
& FRAMES FULL HEIGHT (TYPICAL)
SALVAGE ALL WOOD BASEBOARDS
AND SHOE MOLDING FOR REUSE
REMOVE WALL PARTITIONS, DOORS
& FRAMES FULL HEIGHT (TYPICAL)
SALVAGE ALL WOOD BASEBOARDS
AND SHOE MOLDING FOR REUSE
REMOVE EXISTING
STAIRWELL AND ALL
ITS COMPONENTS IN
ITS ENTIRETY
EXISTING
ELEVATOR
FIELD VERIFY EXISTING STAIR B
TO REMAIN, CAREFULLY
DEMOLISH WALL AROUND
AS INDICATED.
REMOVE PORTION OF EXISTING
PARTITION WALL AS INDICATED
SALVAGE ALL WOOD BASEBOARDS
AND SHOE MOLDING FOR REUSE
REMOVE WALL PARTITIONS, DOORS
& FRAMES FULL HEIGHT (TYPICAL)
SALVAGE ALL WOOD BASEBOARDS
AND SHOE MOLDING FOR REUSE
STRUCTURAL
BULKHEAD
ABOVE TO
REMAIN
REMOVE WINDOW
FRAME/STOPS, PREP
OPENING TO
RECEIVE NEW
WINDOW
EXISTING WOOD
FLOOR TO REMAIN
PREP FOR NEW FINISH
REMOVE CARPET IN
ITS ENTIRETY, PREP
FLOOR AND WOOD
BASEBOARDS TO RECEIVE
NEW FINISH
REMOVE PORTION OF
FLOOR AND JOISTS FOR
NEW HVAC CHASE,
COORDINATE WITH
STRUCTURAL DRAWINGS
SHORE OPENING
DEMOLISH EXISTING CEILING IN ITS
ENTIRETY INCLUDING BULKHEADS,
CEILING FANS AND LIGHT FIXTURES,
UP TO EXISTING ROOF JOISTS,
INCLUDING LAYER OF PLASTER/LATHE
ABOVE - TYPICAL ENTIRE FLOOR
(DO NOT REMOVE STRUCTURAL
MEMBERS SUPPORTING ROOF ABOVE
INFORM ARCHITECT OF CONDITIONS
FOUND AFTER REMOVAL OF CEILING)
REMOVE RAISED FLOOR
AND CARPET IN
ITS ENTIRETY, PREP
FLOOR AND WOOD
BASEBOARDS TO RECEIVE
NEW FINISH
REMOVE WALL PARTITIONS, DOORS
& FRAMES FULL HEIGHT (TYPICAL),
SALVAGE ALL WOOD BASEBOARDS
AND SHOE MOLDING FOR REUSE
CAREFULLY REMOVE WALL
FINISH TO REVEAL EXISTING
BRICK WALL, BRICK WALL
TO REMAIN
REMOVE WALLCOVERING
IN ITS ENTIRETY PREP
SURFACE FOR NEW FINISH
REPAIR WOOD
FLOOR WITH
LIKE MATERIALS
SAND EXISTING
WOOD TRIM @
WINDOWS, PREP
FOR NEW FINISH
BOTTOM SASH
GLAZING FAILURE
REMOVE SASH TO
REPAIR
BOTTOM SASH
GLAZING FAILURE
REMOVE SASH TO
REPAIR
BOTTOM SASH
GLAZING FAILURE
REMOVE SASH TO
REPAIR, REPAIR
TRIM, PREP FOR
NEW FINISH
BOTTOM SASH
GLAZING FAILURE
REMOVE SASH TO
REPAIR, REPAIR
TRIM, PREP FOR
NEW FINISH
REPAIR TRIM,
PREP FOR NEW
FINISH
BOTTOM AND UPPER
SASH GLAZING
FAILURE, REMOVE
SASH TO REPAIR,
REPAIR TRIM, PREP
FOR NEW FINISH
EXISTING FIRE ESCAPE TO BE REMOVED IN
IT'S ENTIRETY, PATCH AND REPAIR HOLES
IN MASONRY WALL WITH LIKE MATERIALS
EXISTING FIRE ESCAPE TO BE REMOVED IN
IT'S ENTIRETY, PATCH AND REPAIR HOLES
IN MASONRY WALL WITH LIKE MATERIALS
REPAIR WALL TO LIKE
NEW CONDITION
WITH LIKE MATERIALS
WHERE EXISTING
WALL WAS REMOVED,
REPAIR WALL TO LIKE
NEW CONDITION
WITH LIKE MATERIALS
WHERE EXISTING
WALL WAS REMOVED,
REPAIR WALL TO LIKE
NEW CONDITION
WITH LIKE MATERIALS
WHERE EXISTING
WALL WAS REMOVED,
REPAIR WALL TO LIKE
NEW CONDITION
WITH LIKE MATERIALS
WHERE EXISTING
WALL WAS REMOVED,
REPAIR WALL TO LIKE
NEW CONDITION
WITH LIKE MATERIALS
WHERE EXISTING
WALL WAS REMOVED,
REPAIR WALL TO LIKE
NEW CONDITION
WITH LIKE MATERIALS
WHERE EXISTING
WALL WAS REMOVED,
REPAIR WALL TO LIKE
NEW CONDITION
WITH LIKE MATERIALS
WHERE EXISTING
WALL WAS REMOVED,
REPAIR WALL TO LIKE
NEW CONDITION
WITH LIKE MATERIALS
WHERE EXISTING
WALL WAS REMOVED,
REPAIR WALL TO LIKE NEW CONDITION
WITH LIKE MATERIALS WHERE EXISTING
WALL WAS REMOVED,
BEAD BOARD
CEILING
REMOVED
DEMOLITION PLAN LEGEND
OBJECT TO BE DEMOLISHED
EXISTING OBJECT TO REMAIN
EXISTING WALLS TO REMAIN
DEMOLITION GENERAL NOTES
A. ALL DEMOLITION WORK SHALL BE EXECUTED IN COMPLIANCE WITH ALL
APPLICABLE FEDERAL, STATE, AND LOCAL CODES, LAWS, AND
REGULATIONS.
B. CONTRACTOR IS TO COORDINATE ALL UTILITY DISCONNECTION WORK
PRIOR TO START OF DEMOLITION WORK.
C. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND PAYING
FOR ALL PERMITS, INSPECTIONS, TESTS, ETC. THAT MAY BE REQUIRED
FOR ALL DEMOLITION WORK.
D. CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL MEANS AND METHODS
OF ALL DEMOLITION WORK AND FOR PROVIDING ALL NECESSARY
TEMPORARY PROTECTION AS NECESSARY FOR THE SAFETY AND
STABILITY OF ALL EXISTING ELEMENTS AND STRUCTURE TO REMAIN.
E. CONTRACTOR SHALL MAINTAIN EXISTING ACCESS TO ADJACENT
PROPERTY DURING DEMOLITION/CONSTRUCTION.
F. CONTRACTOR SHALL VISIT THE SITE AND FACILITY TO VERIFY ALL
EXISTING CONDITIONS AND VERIFY THE SCOPE OF WORK INDICATED
BY ALL CONTRACT DOCUMENTS; FAILURE TO REASONABLY
DETERMINE AND/OR ANTICIPATE THE IMPACT OF THE SCOPE OF
WORK ON EXISTING CONDITIONS SHALL NOT BE JUSTIFICATION
FOR ADDITIONAL COMPENSATION; ANY DISCREPANCIES DISCOVERED
IN THE CONTRACT DOCUMENTS SHALL BE IMMEDIATELY REPORTED
TO ARCHITECT PRIOR TO SUBMISSION OF BID.
G. CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL EXISTING
FIXTURES AND EQUIPMENT THAT REMAINS WITHIN BUILDING OR ON
SITE, UNLESS NOTED OTHERWISE.
H. UNLESS NOTED OTHERWISE, ALL DEMOLISHED MATERIAL AND
EQUIPMENT IS TO BECOME THE PROPERTY OF THE CONTRACTOR
AND SHALL BE REMOVED FROM THE SITE IN A MANNER THAT IS SAFE
AND COMPLIANT WITH MUNICIPAL, STATE, AND FEDERAL
REGULATIONS; NO ON-SITE SALE OF MATERIALS IS ALLOWED.
I. CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION AGAINST
WEATHER INFILTRATION AND CONSTRUCTION ACTIVITIES FOR ALL
EXISTING CONSTRUCTION TO REMAIN DURING THE DEMOLITION AND
CONSTRUCTION PROCESS TO PREVENT DAMAGE TO EXISTING
FINISHES OR MATERIALS THAT ARE TO REMAIN.
J. ALL DEMOLITION WORK PERFORMED IN EXCESS OF THAT INDICATED
ON PLANS AND ANY DAMAGE TO EXISTING-TO-REMAIN
CONSTRUCTION SHALL BE PATCHED, REPAIRED, AND/OR REPLACED
TO "LIKE-NEW" CONDITION AT CONTRACTOR'S EXPENSE.
K. ALL INFILL OR REPLACEMENT WORK SHALL MATCH EXISTING
CONDITIONS IN MATERIALS, CONSTRUCTION, AND FINISH, UNLESS
SPECIFICALLY NOTED ELSEWHERE IN THE DEMOLITION
DOCUMENTS; MATERIAL NOT SPECIFICALLY SPECIFIED SHALL BE
EQUAL IN QUALITY TO EXISTING MATERIAL OR LIKE KIND;
GUARANTEE ALL WORKMANSHIP, MATERIAL, AND PERFORMANCE FOR
A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE (UNLESS
OTHERWISE NOTED).
L. CONTRACTOR IS RESPONSIBLE FOR DEMOLITION AND REMOVAL OF ALL
COMPONENTS IN SUCH A WAY AS TO NOT DAMAGE OR OTHERWISE
COMPROMISE EXISTING STRUCTURE-TO-REMAIN.
M. NOTIFY ARCHITECT AND STRUCTURAL ENGINEER REGARDING
PRE-EXISTING OR CONCURRENT COMPROMISED CONDITIONS
(INCLUDING EXCESSIVE CORROSION, WARPING, OR DEFLECTION)
THAT IS OBSERVED IN EXISTING STRUCTURE-TO-REMAIN (INCLUDING,
BUT NOT LIMITED TO, STEEL DECK, JOISTS, BEAMS, AND COLUMNS).
NEW WORK GENERAL NOTES
A. ALL WALLS ARE FULL HEIGHT, U.N.O. (REFER TO WALL TAG WITH
HEIGHT INDICATED OR TOP OF WALL DELINEATION.
B. PROVIDE GYPSUM BOARD CONTROL JOINTS EVERY 30 FEET MINIMUM.
C. REFER TO ENLARGED PLANS FOR ADDITIONAL DETAILING OR
DIMENSIONING NOT SHOWN THIS SHEET. REFER TO SHEET A0.1 FOR
WALL TYPES.
D. REFER TO A6 SERIES SHEETS FOR ENLARGED PLANS AND
CORRESPONDING INTERIOR ELEVATIONS.
E. REFER TO A7 SERIES SHEETS FOR DOOR AND WINDOW SCHEDULES,
ELEVATIONS AND DETAILS.
F. REFER TO A8 SERIES SHEETS FOR FLOOR FINISH PLANS, SCHEDULES
AND DETAILS.
G. ALL DIMENSIONS ARE FROM EXISTING FACE OF WALL TO FACE OF
STUD, OR FROM OUTSIDE FACE OF STUD TO OUTSIDE FACE OF STUD,
U.N.O.
NEW WORK CODED NOTES
1. GALVANIZED SHIPS LADDER TO ROOF HATCH, REFER TO
SPECIFICATIONS AND DETAILS. (inside clear width 30" x length 60")
2. 5/8" GYPSUM WALL BOARD OVER 7/8" METAL HAT CHANNEL
FURRING.
3. CONTINUOUS PRIVACY CURTAIN AND TRACK, REFER TO S
PECIFICATIONS AND DETAILS.
4. "SOLATUBE" SKYLIGHTS ABOVE, REFER TO DETAILS.
5. EXISTING STAIR ENCLOSURE TO REMAIN.
6. PROVIDE MANUAL BLACK OUT SHADES, REFER TO SPECIFICATIONS.
7. PROVIDE MANUAL WINDOW SHADES, REFER TO SPECIFICATIONS.
8. FROST FILM ON EXISTING WINDOW GLAZING.
9. REPAIR WALL SURFACE TO RECEIVE PAINT, LEVEL 5 FINISH.
10. NEW WINDOW IN EXISTING MASONRY OPENING, TO MATCH EXISTING
BUILDING WINDOW STYLE, GLAZING TO BE FROSTED.
11. RECESSED FIRE EXTINGUISHER CABINET AND FIRE EXTINGUISHER.
12. DECORATIVE PAINTED WOOD FRAMED WALL HUNG MIRROR 18X64.
13. 5/8" GYPSUM WALL BOARD OVER 2 1/2" METAL STUD FURRING.
14. EXTEND EXISTING WALLS FULL HEIGHT TO DECK ABOVE, USE TYPE 'X'
5/8" GYP. BD. OVER 3 5/8" METAL STUDS @ 16" O.C.
X
C
COMMONWEALTH
T
R E
R
A
H C
I
N K
E
UT
OF
B
3 87
I
R E
G
No.
TS E
NT U
C E
YK T
N E R
D
ER
RB
APPROVED FOR PROGRAM CONCEPT ONLY
APPROVED FOR PROGRAM CONCEPT ONLY
DATE
DATE
ENGINEERING
DIVISION OF
AGENCY
AUTHORIZED AGENT
FOR INTENT ONLY
DIV. OF ENGR.
REVIEWED
ENGR. ACCT. NO.
DRAWING NO.
DATE
A&E FILE NO.
CHECKED BY
SHEET DRAWN BY
RECORD DATE
DATEREVISIONS
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES MANAGEMENT
DIVISION OF ENGINEERING
FRANKFORT, KENTUCKY
/5
/2
:5 :5
P
M C
U s e rs
\R H in s o n \D o c u m e n ts
\1
G
C T
C
A b o d e B u il d in g R e n o v a ti o n rh in s o n .r v t
A1.3
THIRD FLOOR DEMOLITION AND
NEW WORK PLANS
470-C5N5-NC11-01
GATEWAY URBAN CAMPUS
09/25/14
201114.02
BB
REH
PROFESSIONAL SERVICES CLASSROOM CENTER
438-440 Scott St., Covington, KY 41011
SCALE: 1/4" = 1'-0"A1.3
2 THIRD FLOOR - NEW WORK
SCALE: 1/4" = 1'-0"A1.3
1 THIRD FLOOR - DEMOLITION
NORTH
PLAN
NORTH
PLAN
AS-BUILT
12-18-15
RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED IN PART, ON THE BASIS OF INFORMATION COMPILED BY OTHERS. THE ARCHITECT/ENGINEER HAS NOT VERIFIED THE ACCURACY OR COMPLETENESS OF THE INFORMATION, AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS THAT MAY BE
INCORPORATED AS A RESULT OF ERRONEOUS INFORMATION PROVIDED BY OTHERS.