This file contains mechanical floor plans showing the third floor and attic layout for a Marine Corps Base Building BEQ HP505 repair project. The drawings are at a scale of 3/32" = 1'-0" and include detailed dimensions for various mechanical elements and ductwork.
The plans show multiple PTHPs (Packaged Terminal Heat Pumps) of varying sizes ranging from 4"x8" to 34"x20", with specific layouts indicated for both the third floor and attic levels. The attic plan shows main trunk lines and ductwork connections, while the third floor plan displays a more detailed arrangement of mechanical equipment and distribution systems. The drawing number is M-102 and appears to be part of a larger set of construction documents for this repair project, as indicated by references to other drawing numbers like M-109 and M-110.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 0016.pdf | ||
| Amend 0015.pdf | ||
| Amend 0014.pdf | ||
| Amend 0013.pdf | ||
| 60040360.pdf | ||
| 60040406.pdf | ||
| 60040345.pdf | ||
| 60040454.pdf | ||
| 60040373.pdf | ||
| 60040328.pdf | ||
| 60040433.pdf | ||
| 60040414.pdf | ||
| N4008523B0034 SpecsAsOne Addendum 01.pdf | ||
| 60040411.pdf | ||
| 60040407.pdf | ||
| 60040420.pdf | ||
| 60040412.pdf | ||
| 60040343.pdf | ||
| Amend 0012.pdf | ||
| 60040362.pdf | ||
| 60040342.pdf | ||
| 60040447.pdf | ||
| 60040408.pdf | ||
| 60040436.pdf | ||
| 60040424.pdf | ||
| 60040329.pdf | ||
| 60040422.pdf | ||
| 60040366.pdf | ||
| 60040376.pdf | ||
| 60040359.pdf | ||
| Amend 0011.pdf | ||
| Amend 0010.pdf | ||
| Amend 0009.pdf | ||
| Amend 0008.pdf | ||
| Amend 0007.pdf | ||
| Amend 0006.pdf | ||
| Amend 0005.pdf | ||
| Amend 0004.pdf | ||
| Amend 0003.pdf | ||
| Amend 0002.pdf | ||
| Amend 0001.pdf | ||
| 23-0034 Asbestos and Lead Assessment.pdf | ||
| 23-0034 Appendix D.pdf | ||
| N4008523B0034 DWGs.pdf | ||
| RFP 230034.pdf | ||
| N4008523B0034 SPECS.pdf |
Show all 46
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M-110 A3
M-109 A2
M-109 A4
12"x12"12"x8"8"x8"4"x8" 12"x8" 12"x12" 10"x12" 10"x8"10"x12" 12"x8"8"x8" 12"x8"8"x8" 12"x12" 12"x8" 8"x8"12"x8" 4"x8"
12"x12"12"x8"8"x8" 12"x8"4"x8" 8"x12" 8"x8"8"x12" 4"x8" 12"x10"6"x10" 12"x12"6"x10" 12"x8" 8"x8"12"x8" 4"x8"
12"x10"8"x10"6"x8"4"x8" 10"x10" 6"x10" 6"x8" 10"x10"6"x10"6"x8" 12"x10" 8"x10" 6"x8" 4"x8"
PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP
PTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHP
16"x16" EA
18"x18" OA18"x18" OA
16"x16" EA
EF-5
16"x16" EA
18"x18" OA
L-9 L-10 L-11 L-12
L-5 L-6 L-7 L-8
18"x18" OA
16"x16" EA
8"x8"
26"x26" OA
34"x20" OA
24"x24" OA
34"x20" OA
3 44 44
(TYP)
M
SYM. DESCRIPTION DATE APP.
REVISIONS
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091
CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M B
F A
N O
SPEC.
M-102
MAS
JDL
MORGAN HUNTER
MAS
REPAIR BEQ HP505
THIRD FLOOR AND ATTIC PLANS - MECHANICAL
60040434 N40085-23-B-0034
110 176
3/32" = 1'-0" A1
THIRD FLOOR PLAN - MECHANICAL
3/32" = 1'-0" C1
ATTIC FLOOR PLAN - MECHANICAL
# PLAN NOTES
1 LOUVER TO BE INSTALLED IN GABLE.
2 PROVIDE 1'-0" DEEP TRIANGULAR INSULATED PLENUM SIZED
TO MATCH DIMENSIONS OF THE LOUVER AND CONNECT TO
INTAKE LOUVER. PROVIDE MANUAL DAMPER IN EACH DUCT
PRIOR TO PLENUM CONNECTION. SEE ARCHITECTURAL
DRAWINGS FOR LOCATION AND SPECIFICATION. STRUCTURAL
MODIFICATION TO WOODEN ROOF TRUSSES, SUPPORTS AND
BRACING WILL BE REQUIRED TO ROUTE DUCT TO LOUVERS
AND TO INSTALL LOUVERS IN GABLE/DORMER WALL.
3 PROVIDE 1'-0" DEEP TRIANGULAR INSULATED PLENUM SIZED
TO MATCH DIMENSIONS OF THE LOUVER AND CONNECT TO
EXHAUST LOUVER. PROVIDE MANUAL DAMPER IN EACH DUCT
PRIOR TO PLENUM CONNECTION. SEE ARCHITECTURAL
DRAWINGS FOR LOCATION AND SPECIFICATION. STRUCTURAL
MODIFICATION TO WOODEN ROOF TRUSSES, SUPPORTS AND
BRACING WILL BE REQUIRED TO ROUTE DUCT TO LOUVERS
AND TO INSTALL LOUVERS IN GABLE/DORMER WALL.
4 PROVIDE MANUAL VOLUME DAMPER AT ALL EXHAUST RISER
CONNECTIONS TO EXHAUST MAIN IN ATTIC.
5 ROUTE EXHAUST DUCT RISER TO INLINE EXHAUST FAN ON
PLATFORM IN ATTIC. ROUTE EXHAUST FROM FAN TO LOUVER
AS SHOWN.
6 EXHAUST AND SUPPLY (VENTILATION) MAIN DUCT RISER UP
FROM LEVELS BELOW. ROUTE TO EXTERIOR LOUVERS AS
SHOWN. PROVIDE TRANSITION AND OFFSET IN OUTSIDE AIR
DUCTWORK TO ALLOW FOR ROUTING OF DUCTWORK UNDER
CATWALK.
7 PROVIDE INLINE EXHAUST FAN ON PLATFORM IN ATTIC.
8 PROVIDE NEW EXHAUST AND SUPPLY (VENTILATION) MAINS
AS SHOWN. SEE ENLARGED PLANS FOR BRANCH DUCTS TO
DIFFUSERS/GRILLES. (TYPICAL ALL EXHAUST AND SUPPLY
MAINS)
9 PROVIDE NEW PTHP UNIT WITH LIGATURE PROOF
PROTECTIVE COVER, CORROSION RESISTANT CHASSIS, AND
3/4" CONDENSATE DRAIN WITH EXTERIOR CLEANOUT. (TYP)
GENERAL NOTES:
1. SEE SHEET M-001 FOR GENERAL NOTES, LEGEND &
ABBREVIATIONS
2. PLAN DRAWINGS ARE DIAGRAMMATIC IN NATURE AND DO NO
ILLUSTRATE ALL SPECIFIC DUCT TAKE-OFF CONFIGURATIONS,
TAPS, ETC. PROVIDE FLEXIBLE DUCTWORK RUNOUTS TO ALL
SUPPLY AND RETURN GRILLES WITH A MAXIMUM LENGTH OF 5
FEET AND SINGLE BENDS NO GREATER THAN 45 DEGREES.
REFER TO PROJECT SPECIFICATIONS AND DUCTWORK
DETAILS FOR SPECIFIC REQUIREMENTS.
3. PIPING IS TO BE INSTALLED SO THAT ALL VALVES, STRAINERS,
UNIONS, TRAPS AND FLANGES REQUIRING ACCESS ARE
EASILY ACCESSIBLE. ALL VALVES MUST BE INSTALLED SO
THAT THE SYSTEM REMAINS IN SERVICE WHEN EQUIPMENT
OR PIPING (ON EQUIPMENT SIDE OF VALVE) IS REMOVED. ALL
BALANCING VALVES AND BUTTERFLY VALVES MUST BE
PROVIDED WITH POSITION INDICATORS AND MAXIMUM
ADJUSTABLE STOPS. ALL VALVES (EXCEPT CONTROL VALVES)
AND STRAINERS MUST BE FULL SIZE OF PIPE BEFORE
REDUCING SIZE TO MAKE CONNECTIONS TO EQUIPMENT OR
CONTROLS.
N
N
GRAPHIC SCALE: 3/32"=1'-0"
8' 0 8' 16' 24'
1 PPI Responses 01.17.25