60040366.pdf

PDF 399 KB Posted

Attached to
Repair BEQ HP505
Solicitation number
N4008525R2549
Issued by

About this file

This file contains architectural building section drawings for the repair of BEQ HP505 at Marine Corps Base Camp Lejeune, North Carolina, as part of contract N40085-23-B-0034. The drawings show longitudinal and transverse building sections with detailed measurements and elevations.

The drawings indicate a three-story structure with floor-to-floor heights of 9'-4" and a roof bearing height of 28'-0". The roof has a 5:12 pitch. The total building height is approximately 34'-1", with an overall length of approximately 44'-5 1/4". The transverse section shows brick masonry construction and includes standard architectural details and dimensions at 3/32" and 3/16" scales. The drawings were prepared by Morgan Hunter, approved by JAS, and dated May 29, 2024, with Addendum 01 dated January 17, 2025.

View the file

Other files

File Type Posted
Amend 0016.pdf PDF
Amend 0015.pdf PDF
Amend 0014.pdf PDF
Amend 0013.pdf PDF
60040360.pdf PDF
60040406.pdf PDF
60040345.pdf PDF
60040454.pdf PDF
60040373.pdf PDF
60040328.pdf PDF
60040433.pdf PDF
60040414.pdf PDF
N4008523B0034 SpecsAsOne Addendum 01.pdf PDF
60040411.pdf PDF
60040407.pdf PDF
60040434.pdf PDF
60040420.pdf PDF
60040412.pdf PDF
60040343.pdf PDF
Amend 0012.pdf PDF
60040362.pdf PDF
60040342.pdf PDF
60040447.pdf PDF
60040408.pdf PDF
60040436.pdf PDF
60040424.pdf PDF
60040329.pdf PDF
60040422.pdf PDF
60040376.pdf PDF
60040359.pdf PDF
Amend 0011.pdf PDF
Amend 0010.pdf PDF
Amend 0009.pdf PDF
Amend 0008.pdf PDF
Amend 0007.pdf PDF
Amend 0006.pdf PDF
Amend 0005.pdf PDF
Amend 0004.pdf PDF
Amend 0003.pdf PDF
Amend 0002.pdf PDF
Amend 0001.pdf PDF
23-0034 Asbestos and Lead Assessment.pdf PDF
23-0034 Appendix D.pdf PDF
N4008523B0034 DWGs.pdf PDF
RFP 230034.pdf PDF
N4008523B0034 SPECS.pdf PDF
Show all 46

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRST FLOOR

0"

SECOND FLOOR

9'-4"

THIRD FLOOR

18'-8"

ROOF BEARING

28'-0"

A1

A-301

A1

A-301

9' -4

9'

-4

9' -4

±3 4'

-1 " ±4

4' -5

/4

5:12 5:12

FIRST FLOOR

0"

SECOND FLOOR

9'-4"

THIRD FLOOR

18'-8"

ROOF BEARING

28'-0"

D3

A-301

D3

A-301

9' -4

9'

-4

9' -4

3'

-4

±4 4'

-5

/4

A-310

A1

5:12 5:12

F ile

P ri n t

SYM. DESCRIPTION DATE APP.

REVISIONS

T

T C

E

TI

HCRAD

R E

G I S

ERE

A N

I

L

ORA

N O

R

T H

C

N

D A

R

N

DE

.J UE

ER

III

C

N

NRB E

E W

M

A

P.

STCETIHCRA

FB

BERN N.C

.NEW

CERT. NO.

UTCETIHCRA

DERET

SI

G E R

N

OI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED: PWO OR OICC

SATISFACTORY TO:

DATE

DATE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

CAMP LEJEUNE, NORTH CAROLINA

MARINE CORPS BASE

SIZE CODE IDENT. NO. NAVFAC DRAWING NO.

E1 80091

CONSTR. CONTR. NO.

AS NOTEDSCALE SHEET

M B

F A

N O

SPEC.

S p ro je c ts

\2

\2

C

L R e p a ir B

E Q

H P

\2

D e s ig n \2

D w g s \2

A

R C

H

.r v t

/1

/2

:0 :1

P

M

A-301

Approver

JAS

JAS

MORGAN HUNTER

JAS

REPAIR BEQ HP505

BUILDING SECTIONS

60040366 N40085-23-B-0034

29 MAY 2024

SCALE: 3/32" = 1'-0"

D3

LONGITUDINAL BUILDING SECTION - CONSTRUCTION

SCALE: 3/16" = 1'-0"

A1

TRANSVERSE BUILDING SECTION - CONSTRUCTION

GRAPHIC SCALE: 3/32"=1'-0"

8' 0 8' 16' 24'

GRAPHIC SCALE: 3/16"=1'-0"

6' 0 4' 8'3'

1 ADDENDUM 01 01.17.25

File details come from the government source that posted it. Updated .