60040373.pdf
PDF 144 KB Posted
- Attached to
- Repair BEQ HP505
- Solicitation number
- N4008525R2549
About this file
This is an architectural drawing sheet (A-501) showing detailed wall, ceiling, and roof assembly specifications for a Bachelor Enlisted Quarters (BEQ) building repair project at Marine Corps Base Camp Lejeune, North Carolina. The drawing includes construction details for various wall assemblies including 8" CMU exterior walls, 4"/6"/8" masonry partitions, and metal stud interior walls with specific gauges and spacing requirements.
The sheet provides detailed specifications for ceiling systems, including suspended acoustical tile ceilings with 15/16" exposed grid systems and suspended gypsum board ceilings with steel framing. Roof assembly details are shown for both the main BEQ building and mechanical building, featuring standing seam metal roofing, multiple layers of rigid insulation, ice & water shield, and structural metal roof decking. The drawing also includes a slab patch detail and existing roof/attic detail. All assemblies are drawn to scale (1-1/2"=1'-0" or 3"=1'-0") with specific dimensions, materials, and installation requirements clearly noted.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 0016.pdf | ||
| Amend 0015.pdf | ||
| Amend 0014.pdf | ||
| Amend 0013.pdf | ||
| 60040360.pdf | ||
| 60040406.pdf | ||
| 60040345.pdf | ||
| 60040454.pdf | ||
| 60040328.pdf | ||
| 60040433.pdf | ||
| 60040414.pdf | ||
| N4008523B0034 SpecsAsOne Addendum 01.pdf | ||
| 60040411.pdf | ||
| 60040407.pdf | ||
| 60040434.pdf | ||
| 60040420.pdf | ||
| 60040412.pdf | ||
| 60040343.pdf | ||
| Amend 0012.pdf | ||
| 60040362.pdf | ||
| 60040342.pdf | ||
| 60040447.pdf | ||
| 60040408.pdf | ||
| 60040436.pdf | ||
| 60040424.pdf | ||
| 60040329.pdf | ||
| 60040422.pdf | ||
| 60040366.pdf | ||
| 60040376.pdf | ||
| 60040359.pdf | ||
| Amend 0011.pdf | ||
| Amend 0010.pdf | ||
| Amend 0009.pdf | ||
| Amend 0008.pdf | ||
| Amend 0007.pdf | ||
| Amend 0006.pdf | ||
| Amend 0005.pdf | ||
| Amend 0004.pdf | ||
| Amend 0003.pdf | ||
| Amend 0002.pdf | ||
| Amend 0001.pdf | ||
| 23-0034 Asbestos and Lead Assessment.pdf | ||
| 23-0034 Appendix D.pdf | ||
| N4008523B0034 DWGs.pdf | ||
| RFP 230034.pdf | ||
| N4008523B0034 SPECS.pdf |
Show all 46
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
3 ROWS OF CHANNEL
STIFFENERS, MIN
ACOUSTICAL INSULATION
3-5/8" 20 GAUGE METAL
STUDS @ 16" O.C.
3 5/8"
1/2" CEMENT BOARD
SHEATHING EACH SIDE
BRICK VENEER
R-5 RIGID INSULATION
CAVITY AND AIR SPACE
AIR AND MOISTURE BARRIER
CONCRETE MASONRY UNIT
HORIZONTAL JOINT REINFORCING
AT 1'-4" ON CENTER
1'-1 1/2"
3 5/8" 7 5/8"
HORIZONTAL JOINT
REINFORCEMENT AT 1'-4" ON
CENTER
CONCRETE MASONRY UNITS
3 5/8"
3 ROWS OF CHANNEL
STIFFENERS, MIN
ACOUSTICAL INSULATION
3-5/8" 20 GAUGE METAL
STUDS @ 16" O.C.
5/8" ABUSE RESISTANT
GYPSUM BOARD ONE
SIDE
3 5/8"
1/2" SMOOTH BARS x 18"
LONG AT 12" ON CENTER -
GREASE BAR IN NEW
CONCRETE AND EPOXY BAR
IN EXISTING CONCRETE
EXISTING
CONCRETE
NEW
CONCRETE
6" 6"
15/16" 7/8"
HANGER WIRE TO
STRUCTURE ABOVE
LAY-IN
ACOUSTICAL
TILE
WALL
BULB TEE
EXPOSED GRID
SYSTEM
FIELD SECTION PERIMETER SECTION
5/8" MOISTURE RESISTANT
GYPSUM BOARD CEILING.
FINISH JOINTS AND PAINT.
VERTICAL WIRES AT
4'-0" ON CENTER
WIRES SPLAYED AT 90° AT 8'-0" ON
CENTER ALONG MAIN RUNNERS
AND WITHIN 2" OF A CROSS
RUNNER
SUSPENDED STEEL FRAMING SYSTEM
OF HEAVY DUTY 1 1/2" MAIN RUNNERS
AT 4'-0" ON CENTER AND 7/8" HAT
CHANNEL CROSS RUNNERS AT 1'-4"
ON CENTER
STANDING SEAM
METAL ROOFING
(1) 1" LAYER AND (2) 2"
LAYERS RIGID INSULATION -
TAPE ALL JOINTS
ICE & WATER SHIELD
STRUCTURAL METAL
ROOF DECKING OVER
LIGHT GAUGE METAL
TRUSSES - SEE
STRUCTURAL
NOTES:
1. INSULATION AND SHEET METAL ROOFING SYSTEM
FASTENERS SHALL NOT PENETRATE BEYOND THE
LOWER PAN OF THE METAL ROOF DECKING.
COORDINATE FASTENER LENGTH AS REQUIRED.
ROOF DECK AIR AND
MOISTURE BARRIER
STANDING SEAM
METAL ROOFING
METAL STUD ROOF
FRAMING - SEE
STRUCTURAL
HORIZONTAL JOINT
REINFORCEMENT AT 1'-4" ON
CENTER
CONCRETE MASONRY UNITS
5 5/8"
HORIZONTAL JOINT
REINFORCEMENT AT 1'-4" ON
CENTER
CONCRETE MASONRY UNITS
7 5/8"
1-5/8" 20 GAUGE METAL
STUDS @ 16" O.C.
1/2" CEMENT BOARD
SHEATHING ONE SIDE
1 5/8"
3/8" AIR SPACE (TYP.)
BRICK VENEER
R-10 RIGID INSULATION
CAVITY AND AIR SPACE
AIR AND MOISTURE BARRIER
CONCRETE MASONRY UNIT
HORIZONTAL JOINT REINFORCING
AT 1'-4" ON CENTER
1'-3 1/2"
3 5/8" 7 5/8"
FLUID APPLIED AIR AND
MOISTURE BARRIER
R-38 BLOWN-IN
INSULATION
EXISTING PRECAST
CONCRETE ROOF
STRUCTURE
F ile
P ri n t
SYM. DESCRIPTION DATE APP.
REVISIONS
T
T C
E
TI
HCRAD
R E
G I S
ERE
A N
I
L
ORA
N O
R
T H
C
N
D A
R
N
DE
.J UE
ER
III
C
N
NRB E
E W
M
A
P.
STCETIHCRA
FB
BERN N.C
.NEW
CERT. NO.
UTCETIHCRA
DERET
SI
G E R
N
OI
TA
RO
PR
OC
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091
CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M B
F A
N O
SPEC.
S p ro je c ts
\2
\2
C
L R e p a ir B
E Q
H P
\2
D e s ig n \2
D w g s \2
A
R C
H
.r v t
/1
/2
:0 :2
P
M
A-501
Approver
Author
Checker
MORGAN HUNTER
Designer
REPAIR BEQ HP505
ASSEMBLIES
60040373 N40085-23-B-0034
29 MAY 2024
SCALE: 1 1/2" = 1'-0"
G
3 5/8" INTERIOR MTL STUD WALL
SCALE: 1 1/2" = 1'-0"
A
8" CMU EXTERIOR WALL
SCALE: 1 1/2" = 1'-0"
C
4" MASONRY PARTITION
SCALE: 1 1/2" = 1'-0"
H
3 5/8" INTERIOR MTL STUD WALL
SCALE: 3" = 1'-0"
B4
SLAB PATCH DETAIL
SCALE: 3" = 1'-0"
A3
SUSPENDED ATC CEILING - 15/16" GRID
SCALE: 1 1/2" = 1'-0"
A1
SUSPENDED GYPSUM BOARD CEILING DETAIL
GRAPHIC SCALE: 1 1/2"=1'-0"
1' 6" 3" 0 1'
GRAPHIC SCALE: 3"=1'-0"
0 3" 6" 1'
SCALE: 1 1/2" = 1'-0"
B2
ROOF DETAIL - MECH BLDG
SCALE: 1 1/2" = 1'-0"
B1
ROOF DETAIL - BEQ
SCALE: 1 1/2" = 1'-0"
D
6" MASONRY PARTITION
SCALE: 1 1/2" = 1'-0"
E
8" MASONRY PARTITION
SCALE: 1 1/2" = 1'-0"
F
1 5/8" INTERIOR MTL STUD WALL
SCALE: 1 1/2" = 1'-0"
B
8" CMU EXTERIOR WALL
SCALE: 1 1/2" = 1'-0"
B3
ROOF DETAIL - EXISTING/ATTIC
1 ADDENDUM 01 01.17.25
File details come from the government source that posted it. Updated .