60040414.pdf
PDF 270 KB Posted
- Attached to
- Repair BEQ HP505
- Solicitation number
- N4008525R2549
About this file
This is a plumbing waste and vent drawing (sheet P-103) for the Repair BEQ HP505 project at Marine Corps Base Camp Lejeune, North Carolina. The drawing shows enlarged floor plans of the central core area on the first floor and mechanical rooms on both first and second floors, with detailed waste and vent piping layouts at 1/4"=1'-0" scale.
The drawing includes specific plumbing details such as 8" waste piping connections to existing sanitary sewer, 4" waste and 3" vent risers, vent piping routing through soffits and chases, waste riser offsets for hydraulic jumps, lint interceptor vent piping below floor level, and requirements for drain pipe insulation in exposed areas. The drawing is part of construction contract N40085-23-B-0034 and was prepared by the Department of the Navy Naval Facilities Engineering Systems Command, with detailed room numbers, pipe sizes, and plumbing fixtures clearly indicated throughout the floor plans.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 0016.pdf | ||
| Amend 0015.pdf | ||
| Amend 0014.pdf | ||
| Amend 0013.pdf | ||
| 60040360.pdf | ||
| 60040406.pdf | ||
| 60040345.pdf | ||
| 60040454.pdf | ||
| 60040373.pdf | ||
| 60040328.pdf | ||
| 60040433.pdf | ||
| N4008523B0034 SpecsAsOne Addendum 01.pdf | ||
| 60040411.pdf | ||
| 60040407.pdf | ||
| 60040434.pdf | ||
| 60040420.pdf | ||
| 60040412.pdf | ||
| 60040343.pdf | ||
| Amend 0012.pdf | ||
| 60040362.pdf | ||
| 60040342.pdf | ||
| 60040447.pdf | ||
| 60040408.pdf | ||
| 60040436.pdf | ||
| 60040424.pdf | ||
| 60040329.pdf | ||
| 60040422.pdf | ||
| 60040366.pdf | ||
| 60040376.pdf | ||
| 60040359.pdf | ||
| Amend 0011.pdf | ||
| Amend 0010.pdf | ||
| Amend 0009.pdf | ||
| Amend 0008.pdf | ||
| Amend 0007.pdf | ||
| Amend 0006.pdf | ||
| Amend 0005.pdf | ||
| Amend 0004.pdf | ||
| Amend 0003.pdf | ||
| Amend 0002.pdf | ||
| Amend 0001.pdf | ||
| 23-0034 Asbestos and Lead Assessment.pdf | ||
| 23-0034 Appendix D.pdf | ||
| N4008523B0034 DWGs.pdf | ||
| RFP 230034.pdf | ||
| N4008523B0034 SPECS.pdf |
Show all 46
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DUTY
CORRIDOR
ELECTRICAL
TOILET
LAUNDRY
STAIR
142STORAGE
LAUNDRY
Room
Room
Room
Room
Room
120A
Room
121A
P-5
WCO
P-5
P-5
P-5
P-6
P-4
P-1
3"V UP
P-5
P-5
P-5
P-5
P-5
P-5
P-5
P-5
FCO
P-2
P-1
P-3 P-3
P-1
P-3 P-3
P-2
P-2
P-2
P-8
FCO
LI-1
LI-1 3"W UP
2"V UP
FCO
WCO
WCO
2"W UP
2"FD-B 2"FD-B
2"FD-B 2"FD-B
3"FD-A 3"FD-A
3"FD-A
FCO
4" W
6" W
2" V
6" W 6" W
W
4" W6" W
3" W
W
6" W
W
MECHANICAL
3"W UP
3"FD-A
W
4" W
Room
3"W
UP&DN
3"FD-A
SYM. DESCRIPTION DATE APP.
REVISIONS
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091
CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M B
F A
N O
SPEC.
P-103
DLB
DJG
PRC
MORGAN HUNTER
PRC
REPAIR BEQ HP505
PARTIAL ENLARGED FLOOR PLANS - FIRST AND SECOND FLOOR -
WASTE AND VENT
60040414 N40085-23-B-0034
1/4" = 1'-0" B1
FIRST FLOOR ENLARGED PLAN - CENTRAL CORE - WASTE AND VENT
1/4" = 1'-0"
B3
FIRST FLOOR - EAST MECH. ROOM - WASTE AND VENT
1/4" = 1'-0" B4
SECOND FLOOR - EAST MECH. ROOM - WASTE AND VENT
GRAPHIC SCALE: 1/4"=1'-0"
4' 0 2' 4' 8'
PLAN NOTES - P-103
1 EXTEND AND CONNECT NEW 8"W PIPING TO EXISTING
SANITARY SEWER PIPING BELOW SLAB AT THIS
LOCATION.
2 4"W & 3"V UP.
3 VENT PIPING ROUTED ABOVE WASTE PIPING IN CHASE.
4 ROUTE VENT PIPING IN SOFFIT THEN DROP DOWN INTO
CHASE FOR WASHER BOXES.
5 OFFSET WASTE RISER PIPING IN VERTICAL TO ALLOW
FOR HYDRAULIC JUMP PRIOR TO TYING INTO WASTE
MAIN. TYPICAL FOR ALL SLEEPING ROOM WASTE
RISERS.
6 LINT INTERCEPTOR VENT PIPING ROUTED BELOW
FLOOR.
7 INSULATE ALL DRAIN PIPE THAT IS EXPOSED IN THIS
AREA.
N N N
1 PPI RESPONSES 01.17.25
user.dj.german Model
File details come from the government source that posted it. Updated .