60040414.pdf

PDF 270 KB Posted

Attached to
Repair BEQ HP505
Solicitation number
N4008525R2549
Issued by

About this file

This is a plumbing waste and vent drawing (sheet P-103) for the Repair BEQ HP505 project at Marine Corps Base Camp Lejeune, North Carolina. The drawing shows enlarged floor plans of the central core area on the first floor and mechanical rooms on both first and second floors, with detailed waste and vent piping layouts at 1/4"=1'-0" scale.

The drawing includes specific plumbing details such as 8" waste piping connections to existing sanitary sewer, 4" waste and 3" vent risers, vent piping routing through soffits and chases, waste riser offsets for hydraulic jumps, lint interceptor vent piping below floor level, and requirements for drain pipe insulation in exposed areas. The drawing is part of construction contract N40085-23-B-0034 and was prepared by the Department of the Navy Naval Facilities Engineering Systems Command, with detailed room numbers, pipe sizes, and plumbing fixtures clearly indicated throughout the floor plans.

View the file

Other files

File Type Posted
Amend 0016.pdf PDF
Amend 0015.pdf PDF
Amend 0014.pdf PDF
Amend 0013.pdf PDF
60040360.pdf PDF
60040406.pdf PDF
60040345.pdf PDF
60040454.pdf PDF
60040373.pdf PDF
60040328.pdf PDF
60040433.pdf PDF
N4008523B0034 SpecsAsOne Addendum 01.pdf PDF
60040411.pdf PDF
60040407.pdf PDF
60040434.pdf PDF
60040420.pdf PDF
60040412.pdf PDF
60040343.pdf PDF
Amend 0012.pdf PDF
60040362.pdf PDF
60040342.pdf PDF
60040447.pdf PDF
60040408.pdf PDF
60040436.pdf PDF
60040424.pdf PDF
60040329.pdf PDF
60040422.pdf PDF
60040366.pdf PDF
60040376.pdf PDF
60040359.pdf PDF
Amend 0011.pdf PDF
Amend 0010.pdf PDF
Amend 0009.pdf PDF
Amend 0008.pdf PDF
Amend 0007.pdf PDF
Amend 0006.pdf PDF
Amend 0005.pdf PDF
Amend 0004.pdf PDF
Amend 0003.pdf PDF
Amend 0002.pdf PDF
Amend 0001.pdf PDF
23-0034 Asbestos and Lead Assessment.pdf PDF
23-0034 Appendix D.pdf PDF
N4008523B0034 DWGs.pdf PDF
RFP 230034.pdf PDF
N4008523B0034 SPECS.pdf PDF
Show all 46

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DUTY

CORRIDOR

ELECTRICAL

TOILET

LAUNDRY

STAIR

142STORAGE

LAUNDRY

Room

Room

Room

Room

Room

120A

Room

121A

P-5

WCO

P-5

P-5

P-5

P-6

P-4

P-1

3"V UP

P-5

P-5

P-5

P-5

P-5

P-5

P-5

P-5

FCO

P-2

P-1

P-3 P-3

P-1

P-3 P-3

P-2

P-2

P-2

P-8

FCO

LI-1

LI-1 3"W UP

2"V UP

FCO

WCO

WCO

2"W UP

2"FD-B 2"FD-B

2"FD-B 2"FD-B

3"FD-A 3"FD-A

3"FD-A

FCO

4" W

6" W

2" V

6" W 6" W

W

4" W6" W

3" W

W

6" W

W

MECHANICAL

3"W UP

3"FD-A

W

4" W

Room

3"W

UP&DN

3"FD-A

SYM. DESCRIPTION DATE APP.

REVISIONS

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED: PWO OR OICC

SATISFACTORY TO:

DATE

DATE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

CAMP LEJEUNE, NORTH CAROLINA

MARINE CORPS BASE

SIZE CODE IDENT. NO. NAVFAC DRAWING NO.

E1 80091

CONSTR. CONTR. NO.

AS NOTEDSCALE SHEET

M B

F A

N O

SPEC.

P-103

DLB

DJG

PRC

MORGAN HUNTER

PRC

REPAIR BEQ HP505

PARTIAL ENLARGED FLOOR PLANS - FIRST AND SECOND FLOOR -

WASTE AND VENT

60040414 N40085-23-B-0034

1/4" = 1'-0" B1

FIRST FLOOR ENLARGED PLAN - CENTRAL CORE - WASTE AND VENT

1/4" = 1'-0"

B3

FIRST FLOOR - EAST MECH. ROOM - WASTE AND VENT

1/4" = 1'-0" B4

SECOND FLOOR - EAST MECH. ROOM - WASTE AND VENT

GRAPHIC SCALE: 1/4"=1'-0"

4' 0 2' 4' 8'

PLAN NOTES - P-103

1 EXTEND AND CONNECT NEW 8"W PIPING TO EXISTING

SANITARY SEWER PIPING BELOW SLAB AT THIS

LOCATION.

2 4"W & 3"V UP.

3 VENT PIPING ROUTED ABOVE WASTE PIPING IN CHASE.

4 ROUTE VENT PIPING IN SOFFIT THEN DROP DOWN INTO

CHASE FOR WASHER BOXES.

5 OFFSET WASTE RISER PIPING IN VERTICAL TO ALLOW

FOR HYDRAULIC JUMP PRIOR TO TYING INTO WASTE

MAIN. TYPICAL FOR ALL SLEEPING ROOM WASTE

RISERS.

6 LINT INTERCEPTOR VENT PIPING ROUTED BELOW

FLOOR.

7 INSULATE ALL DRAIN PIPE THAT IS EXPOSED IN THIS

AREA.

N N N

1 PPI RESPONSES 01.17.25