60040412.pdf

PDF 938 KB Posted

Attached to
Repair BEQ HP505
Solicitation number
N4008525R2549
Issued by

About this file

This is a plumbing engineering drawing showing waste and vent floor plans for the repair of BEQ HP505 at Marine Corps Base Camp Lejeune, North Carolina, prepared by the Naval Facilities Engineering Systems Command (NAVFAC). The drawing (P-101) includes waste and vent layouts for three floors at a scale of 3/32"=1'-0", showing pipe sizes ranging from 3" to 6" for both waste and vent lines.

The plans indicate vertical connections between floors with 4"W & 3"V piping, a sump pump installation requirement, and roof penetrations for 3" and 4" vents. The drawing includes detailed notes for central core connections on each floor and is part of construction contract N40085-23-B-0034. The document is sheet 88 of 176, suggesting this is part of a larger set of construction drawings for the building renovation project.

View the file

Other files

File Type Posted
Amend 0016.pdf PDF
Amend 0015.pdf PDF
Amend 0014.pdf PDF
Amend 0013.pdf PDF
60040360.pdf PDF
60040406.pdf PDF
60040345.pdf PDF
60040454.pdf PDF
60040373.pdf PDF
60040328.pdf PDF
60040433.pdf PDF
60040414.pdf PDF
N4008523B0034 SpecsAsOne Addendum 01.pdf PDF
60040411.pdf PDF
60040407.pdf PDF
60040434.pdf PDF
60040420.pdf PDF
60040343.pdf PDF
Amend 0012.pdf PDF
60040362.pdf PDF
60040342.pdf PDF
60040447.pdf PDF
60040408.pdf PDF
60040436.pdf PDF
60040424.pdf PDF
60040329.pdf PDF
60040422.pdf PDF
60040366.pdf PDF
60040376.pdf PDF
60040359.pdf PDF
Amend 0011.pdf PDF
Amend 0010.pdf PDF
Amend 0009.pdf PDF
Amend 0008.pdf PDF
Amend 0007.pdf PDF
Amend 0006.pdf PDF
Amend 0005.pdf PDF
Amend 0004.pdf PDF
Amend 0003.pdf PDF
Amend 0002.pdf PDF
Amend 0001.pdf PDF
23-0034 Asbestos and Lead Assessment.pdf PDF
23-0034 Appendix D.pdf PDF
N4008523B0034 DWGs.pdf PDF
RFP 230034.pdf PDF
N4008523B0034 SPECS.pdf PDF
Show all 46

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P-102

C1 P-102

C3

P-103

B1 P-103

B3

1 1

6" W 4" W4" W

6" W

W

6" W

P-102

C4 P-104

B1

P-103

B4

P-104

B2

P-104

B4 P-104

B5

333 6

5 5

6 6 6

SYM. DESCRIPTION DATE APP.

REVISIONS

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED: PWO OR OICC

SATISFACTORY TO:

DATE

DATE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

CAMP LEJEUNE, NORTH CAROLINA

MARINE CORPS BASE

SIZE CODE IDENT. NO. NAVFAC DRAWING NO.

E1 80091

CONSTR. CONTR. NO.

AS NOTEDSCALE SHEET

M B

F A

N O

SPEC.

P-101

DLB

DJG

PRC

MORGAN HUNTER

PRC

REPAIR BEQ HP505

FLOOR PLANS - WASTE AND VENT

60040412 N40085-23-B-0034

3/32" = 1'-0" A3

FIRST FLOOR PLAN - WASTE AND VENT

3/32" = 1'-0" C3

SECOND FLOOR PLAN - WASTE AND VENT

3/32" = 1'-0" D3

THIRD FLOOR PLAN - WASTE AND VENT

PLAN NOTES - P-101

1 4"W & 3"V UP. SEE "FIRST FLOOR ENLARGED PLAN -

CENTRAL CORE - WASTE AND VENT" FOR MORE

DETAILS.

2 4'W & 3"V UP & DN. SEE "SECOND FLOOR ENLARGED

PLAN - CENTRAL CORE - WASTE AND VENT" FOR MORE

DETAILS.

3 4'W & 3"V DN. SEE "THIRD FLOOR ENLARGED PLAN -

CENTRAL CORE - WASTE AND VENT" FOR MORE

DETAILS.

4 PROVIDE SUMP PUMP IN THE GENERAL LOCATION

SHOWN. ROUTE PIPING TO TIE INTO TOP OF WASTE

MAIN.

5 3" VENT THRU ROOF.

6 4" VENT THRU ROOF.

N

N

N

GRAPHIC SCALE: 3/32"=1'-0"

8' 0 8' 16' 24'

1 PPI RESPONSES 01.17.25

user.dj.german Model

File details come from the government source that posted it. Updated .