This is a life safety floor plan drawing for a Bachelor Enlisted Quarters (BEQ) repair project at Marine Corps Base Camp Lejeune, North Carolina. The drawing shows the first floor layout and mechanical building plans with fire safety details, including fire-rated barriers and penetrations.
The drawing includes general sheet notes regarding fire safety requirements, such as marking fire-rated barriers according to IBC Section 703.5, maintaining fire-resistance ratings for walls/floors/ceilings/shafts, and using UL listed firestop systems for penetrations. The floor must maintain a 1/2-hour fire rating. The drawing is part of construction contract N40085-23-B-0034, specification number 60040328, and was updated on January 17, 2025. The plan shows various rooms including mechanical spaces, storage, stairs, laundry facilities, toilets, electrical rooms, corridors, and duty stations, with detailed dimensions and fire safety considerations throughout the layout.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 0016.pdf | ||
| Amend 0015.pdf | ||
| Amend 0014.pdf | ||
| Amend 0013.pdf | ||
| 60040360.pdf | ||
| 60040406.pdf | ||
| 60040345.pdf | ||
| 60040454.pdf | ||
| 60040373.pdf | ||
| 60040433.pdf | ||
| 60040414.pdf | ||
| N4008523B0034 SpecsAsOne Addendum 01.pdf | ||
| 60040411.pdf | ||
| 60040407.pdf | ||
| 60040434.pdf | ||
| 60040420.pdf | ||
| 60040412.pdf | ||
| 60040343.pdf | ||
| Amend 0012.pdf | ||
| 60040362.pdf | ||
| 60040342.pdf | ||
| 60040447.pdf | ||
| 60040408.pdf | ||
| 60040436.pdf | ||
| 60040424.pdf | ||
| 60040329.pdf | ||
| 60040422.pdf | ||
| 60040366.pdf | ||
| 60040376.pdf | ||
| 60040359.pdf | ||
| Amend 0011.pdf | ||
| Amend 0010.pdf | ||
| Amend 0009.pdf | ||
| Amend 0008.pdf | ||
| Amend 0007.pdf | ||
| Amend 0006.pdf | ||
| Amend 0005.pdf | ||
| Amend 0004.pdf | ||
| Amend 0003.pdf | ||
| Amend 0002.pdf | ||
| Amend 0001.pdf | ||
| 23-0034 Asbestos and Lead Assessment.pdf | ||
| 23-0034 Appendix D.pdf | ||
| N4008523B0034 DWGs.pdf | ||
| RFP 230034.pdf | ||
| N4008523B0034 SPECS.pdf |
Show all 46
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
K
100 102
101 103
104 106
105 107
108 110
109 111
MECHANICAL
112 114
113 115
116 118
117 119
STORAGE
STAIR
LAUNDRY
TOILET
ELECTRICAL
CORRIDOR
DUTY
LAUNDRY
120 122
121 123
124 126
125 127
MECHANICAL
128 130
129 131
132 134
133 135
136 138
137 139
2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
R T
-F
T
CP = 44-FT
MECHANICAL
BUILDING
MECHANICAL
YARD
TD = 48-FT
GENERAL SHEET NOTES:
1.
2.
3.
4.
5.
6.
7.
FOR LIFE SAFETY LEGEND, SEE SHEET GI001.
APPLY MARKINGS TO FIRE-RATED BARRIERS INDICATING ITS
RATING IN ACCORDANCE WITH IBC SECTION 703.5.
FIRESTOP PENETRATIONS AND JOINTS TO MAINTAIN THE
INTEGRITY OF THE FIRE-RATED CONSTRUCTION. FIRE-
RESISTANCE-RATING OF WALLS, FLOORS, CEILINGS, AND
SHAFTS MUST BE MAINTAINED.
PENETRATIONS AND JOINTS MUST BE PROVIDED WITH UL
LISTED FIRESTOP SYSTEMS.
THE RATINGS OF FIRESTOP SYSTEMS MUST BE GREATER
THAN OR EQUAL TO THE RATING OF THE BARRIER.
UL ASSEMBLIES AND MATERIAL PRODUCT DATA SHEETS
FOR FIRESTOPPING SYSTEMS MUST BE SUBMITTED AND
APPROVED BEFORE ANY FIRESTOPPING IS INSTALLED.
REFER TO THE PROJECT SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS AND INFORMATION.
THE FLOOR MUST MAINTAIN A 1/2-HR FIRE RATING.
Lic. No. 044409
AARON P FREIDC
O M M O
N W
EA
LTHOF
V
IR
G
IN
I A
P R O F
E
SSIONAL EN
G
IN
E E R
29 MAY 2024
F ile
P ri n t
SYM. DESCRIPTION DATE APP.
REVISIONS
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091
CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M B
F A
N O
SPEC.
C U s e rs \a fr e id
\O n e
D ri v e
J e n s e n H u g h e s \D o c u m e n ts \2
F
IR
E a fr e id
.r v t
/1
/2
:4 :1
P
M
GI101
AHE
KEC
MORGAN HUNTER
APF
APF
REPAIR BEQ HP505
LIFE SAFETY FIRST FLOOR PLAN - CONSTRUCTION
60040328 N40085-23-B-0034
SCALE: 3/32" = 1'-0"
D1
LIFE SAFETY FIRST FLOOR PLAN - CONSTRUCTION
N
GRAPHIC SCALE: 1/8"=1'-0"
8' 0 4' 8' 16'
GRAPHIC SCALE: 3/32"=1'-0"
8' 0 4' 8' 16'
SCALE: 1/8" = 1'-0"
B1
MECHANICAL BUILDING LIFE SAFETY PLAN
1 PPI UPDATES 01/17/25 APF
File details come from the government source that posted it. Updated .