This is a life safety floor plan drawing for a Bachelor Enlisted Quarters (BEQ) repair project at Marine Corps Base Camp Lejeune, North Carolina. The drawing shows the first floor layout and mechanical building plans with fire safety details, including fire-rated barriers and penetrations.

The drawing includes general sheet notes regarding fire safety requirements, such as marking fire-rated barriers according to IBC Section 703.5, maintaining fire-resistance ratings for walls/floors/ceilings/shafts, and using UL listed firestop systems for penetrations. The floor must maintain a 1/2-hour fire rating. The drawing is part of construction contract N40085-23-B-0034, specification number 60040328, and was updated on January 17, 2025. The plan shows various rooms including mechanical spaces, storage, stairs, laundry facilities, toilets, electrical rooms, corridors, and duty stations, with detailed dimensions and fire safety considerations throughout the layout.

View the file

Other files

File Type Posted
Amend 0016.pdf PDF
Amend 0015.pdf PDF
Amend 0014.pdf PDF
Amend 0013.pdf PDF
60040360.pdf PDF
60040406.pdf PDF
60040345.pdf PDF
60040454.pdf PDF
60040373.pdf PDF
60040433.pdf PDF
60040414.pdf PDF
N4008523B0034 SpecsAsOne Addendum 01.pdf PDF
60040411.pdf PDF
60040407.pdf PDF
60040434.pdf PDF
60040420.pdf PDF
60040412.pdf PDF
60040343.pdf PDF
Amend 0012.pdf PDF
60040362.pdf PDF
60040342.pdf PDF
60040447.pdf PDF
60040408.pdf PDF
60040436.pdf PDF
60040424.pdf PDF
60040329.pdf PDF
60040422.pdf PDF
60040366.pdf PDF
60040376.pdf PDF
60040359.pdf PDF
Amend 0011.pdf PDF
Amend 0010.pdf PDF
Amend 0009.pdf PDF
Amend 0008.pdf PDF
Amend 0007.pdf PDF
Amend 0006.pdf PDF
Amend 0005.pdf PDF
Amend 0004.pdf PDF
Amend 0003.pdf PDF
Amend 0002.pdf PDF
Amend 0001.pdf PDF
23-0034 Asbestos and Lead Assessment.pdf PDF
23-0034 Appendix D.pdf PDF
N4008523B0034 DWGs.pdf PDF
RFP 230034.pdf PDF
N4008523B0034 SPECS.pdf PDF
Show all 46

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

K

100 102

101 103

104 106

105 107

108 110

109 111

MECHANICAL

112 114

113 115

116 118

117 119

STORAGE

STAIR

LAUNDRY

TOILET

ELECTRICAL

CORRIDOR

DUTY

LAUNDRY

120 122

121 123

124 126

125 127

MECHANICAL

128 130

129 131

132 134

133 135

136 138

137 139

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

R T

-F

T

CP = 44-FT

MECHANICAL

BUILDING

MECHANICAL

YARD

TD = 48-FT

GENERAL SHEET NOTES:

1.

2.

3.

4.

5.

6.

7.

FOR LIFE SAFETY LEGEND, SEE SHEET GI001.

APPLY MARKINGS TO FIRE-RATED BARRIERS INDICATING ITS

RATING IN ACCORDANCE WITH IBC SECTION 703.5.

FIRESTOP PENETRATIONS AND JOINTS TO MAINTAIN THE

INTEGRITY OF THE FIRE-RATED CONSTRUCTION. FIRE-

RESISTANCE-RATING OF WALLS, FLOORS, CEILINGS, AND

SHAFTS MUST BE MAINTAINED.

PENETRATIONS AND JOINTS MUST BE PROVIDED WITH UL

LISTED FIRESTOP SYSTEMS.

THE RATINGS OF FIRESTOP SYSTEMS MUST BE GREATER

THAN OR EQUAL TO THE RATING OF THE BARRIER.

UL ASSEMBLIES AND MATERIAL PRODUCT DATA SHEETS

FOR FIRESTOPPING SYSTEMS MUST BE SUBMITTED AND

APPROVED BEFORE ANY FIRESTOPPING IS INSTALLED.

REFER TO THE PROJECT SPECIFICATIONS FOR ADDITIONAL

REQUIREMENTS AND INFORMATION.

THE FLOOR MUST MAINTAIN A 1/2-HR FIRE RATING.

Lic. No. 044409

AARON P FREIDC

O M M O

N W

EA

LTHOF

V

IR

G

IN

I A

P R O F

E

SSIONAL EN

G

IN

E E R

29 MAY 2024

F ile

P ri n t

SYM. DESCRIPTION DATE APP.

REVISIONS

DR.

DES.

CHK.

SUBMITTED BY:

DESIGN DIR.

APPROVED: PWO OR OICC

SATISFACTORY TO:

DATE

DATE

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

CAMP LEJEUNE, NORTH CAROLINA

MARINE CORPS BASE

SIZE CODE IDENT. NO. NAVFAC DRAWING NO.

E1 80091

CONSTR. CONTR. NO.

AS NOTEDSCALE SHEET

M B

F A

N O

SPEC.

C U s e rs \a fr e id

\O n e

D ri v e

J e n s e n H u g h e s \D o c u m e n ts \2

F

IR

E a fr e id

.r v t

/1

/2

:4 :1

P

M

GI101

AHE

KEC

MORGAN HUNTER

APF

APF

REPAIR BEQ HP505

LIFE SAFETY FIRST FLOOR PLAN - CONSTRUCTION

60040328 N40085-23-B-0034

SCALE: 3/32" = 1'-0"

D1

LIFE SAFETY FIRST FLOOR PLAN - CONSTRUCTION

N

GRAPHIC SCALE: 1/8"=1'-0"

8' 0 4' 8' 16'

GRAPHIC SCALE: 3/32"=1'-0"

8' 0 4' 8' 16'

SCALE: 1/8" = 1'-0"

B1

MECHANICAL BUILDING LIFE SAFETY PLAN

1 PPI UPDATES 01/17/25 APF

File details come from the government source that posted it. Updated .