60040433.pdf
PDF 754 KB Posted
- Attached to
- Repair BEQ HP505
- Solicitation number
- N4008525R2549
About this file
This is a mechanical floor plan drawing (sheet M-101) for a Marine Corps Base BEQ (Bachelor Enlisted Quarters) repair project HP505. The drawing shows detailed mechanical layouts for both the first and second floors at a scale of 3/32" = 1'-0". The plans appear to show PTHP (Packaged Terminal Heat Pump) units arranged throughout both floors, with various room dimensions noted (ranging from 4"x8" to 12"x12").
The drawing contains basic general notes and includes revision tracking fields, though no revisions are listed. The sheet is part of drawing set 60040433 and appears to be associated with a Naval Facilities Engineering Command (NAVFAC) contract. The mechanical systems shown follow a repetitive pattern across multiple building sections, suggesting this is a standard barracks-style building layout with distributed HVAC units serving individual rooms.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 0016.pdf | ||
| Amend 0015.pdf | ||
| Amend 0014.pdf | ||
| Amend 0013.pdf | ||
| 60040360.pdf | ||
| 60040406.pdf | ||
| 60040345.pdf | ||
| 60040454.pdf | ||
| 60040373.pdf | ||
| 60040328.pdf | ||
| 60040414.pdf | ||
| N4008523B0034 SpecsAsOne Addendum 01.pdf | ||
| 60040411.pdf | ||
| 60040407.pdf | ||
| 60040434.pdf | ||
| 60040420.pdf | ||
| 60040412.pdf | ||
| 60040343.pdf | ||
| Amend 0012.pdf | ||
| 60040362.pdf | ||
| 60040342.pdf | ||
| 60040447.pdf | ||
| 60040408.pdf | ||
| 60040436.pdf | ||
| 60040424.pdf | ||
| 60040329.pdf | ||
| 60040422.pdf | ||
| 60040366.pdf | ||
| 60040376.pdf | ||
| 60040359.pdf | ||
| Amend 0011.pdf | ||
| Amend 0010.pdf | ||
| Amend 0009.pdf | ||
| Amend 0008.pdf | ||
| Amend 0007.pdf | ||
| Amend 0006.pdf | ||
| Amend 0005.pdf | ||
| Amend 0004.pdf | ||
| Amend 0003.pdf | ||
| Amend 0002.pdf | ||
| Amend 0001.pdf | ||
| 23-0034 Asbestos and Lead Assessment.pdf | ||
| 23-0034 Appendix D.pdf | ||
| N4008523B0034 DWGs.pdf | ||
| RFP 230034.pdf | ||
| N4008523B0034 SPECS.pdf |
Show all 46
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M-104
A3 M-106
A3 M-105
A2
PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP
PTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHP
PTHP PTHP PTHP PTHP PTHP PTHP
PTHP PTHP PTHP PTHP PTHP PTHP
M-105
A4
12"x12"12"x8"8"x8"4"x8" 12"x8" 12"x12" 10"x12" 10"x8"10"x12" 12"x8"8"x8" 12"x8"8"x8" 12"x12" 12"x8" 8"x8"12"x8" 4"x8"
12"x12"12"x8"8"x8" 12"x8"4"x8" 8"x12" 8"x8"8"x12" 4"x8" 12"x10"6"x10" 12"x12"6"x10" 12"x8" 8"x8"12"x8" 4"x8"
12"x10"8"x10"6"x8"4"x8" 10"x10" 6"x10" 6"x8" 10"x10"6"x10"6"x8" 12"x10" 8"x10" 6"x8" 4"x8"
M-108
A3
M-107 A2
M-107
A4
12"x12"12"x8"8"x8"4"x8" 12"x8" 12"x12" 10"x12" 10"x8"10"x12" 12"x8"8"x8" 12"x8"8"x8" 12"x12" 12"x8" 8"x8"12"x8" 4"x8"
12"x12"12"x8"8"x8" 12"x8"4"x8" 8"x12" 8"x8"8"x12" 4"x8" 12"x10"6"x10" 12"x12"6"x10" 12"x8" 8"x8"12"x8" 4"x8"
12"x10"8"x10"6"x8"4"x8" 10"x10" 6"x10" 6"x8" 10"x10"6"x10"6"x8" 12"x10" 8"x10" 6"x8" 4"x8"
PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP PTHP
PTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHPPTHP
SYM. DESCRIPTION DATE APP.
REVISIONS
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091
CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M B
F A
N O
SPEC.
M-101
MAS
JDL
MORGAN HUNTER
MAS
REPAIR BEQ HP505
FIRST AND SECOND FLOOR PLANS - MECHANICAL
60040433 N40085-23-B-0034
109 176
3/32" = 1'-0" A1
FIRST FLOOR PLAN - MECHANICAL
3/32" = 1'-0" B1
SECOND FLOOR PLAN - MECHANICAL
# PLAN NOTES
1 PROVIDE NEW EXHAUST AND SUPPLY (VENTILATION) MAINS
AS SHOWN. SEE ENLARGED PLANS FOR BRANCH DUCTS TO
DIFFUSERS/GRILLES. (TYPICAL ALL EXHAUST AND SUPPLY
MAINS)
2 PROVIDE NEW PTHP UNIT WITH LIGATURE PROOF
PROTECTIVE COVER, CORROSION RESISTANT CHASSIS, AND
3/4" CONDENSATE DRAIN WITH EXTERIOR CLEANOUT. PAINT
ALL DDC CONDUIT EXPOSED IN OCCUPIED AREAS TO MATCH
INTERIOR. COORDINATE WITH ARCHITECTURAL AND INTERIOR
PLANS. (TYP)
GENERAL NOTES:
1. SEE SHEET M-001 FOR GENERAL NOTES, LEGEND &
ABBREVIATIONS
2. PLAN DRAWINGS ARE DIAGRAMMATIC IN NATURE AND DO NO
ILLUSTRATE ALL SPECIFIC DUCT TAKE-OFF CONFIGURATIONS,
TAPS, ETC. PROVIDE FLEXIBLE DUCTWORK RUNOUTS TO ALL
SUPPLY AND RETURN GRILLES WITH A MAXIMUM LENGTH OF 5
FEET AND SINGLE BENDS NO GREATER THAN 45 DEGREES.
REFER TO PROJECT SPECIFICATIONS AND DUCTWORK
DETAILS FOR SPECIFIC REQUIREMENTS.
3. PIPING IS TO BE INSTALLED SO THAT ALL VALVES, STRAINERS,
UNIONS, TRAPS AND FLANGES REQUIRING ACCESS ARE
EASILY ACCESSIBLE. ALL VALVES MUST BE INSTALLED SO
THAT THE SYSTEM REMAINS IN SERVICE WHEN EQUIPMENT
OR PIPING (ON EQUIPMENT SIDE OF VALVE) IS REMOVED. ALL
BALANCING VALVES AND BUTTERFLY VALVES MUST BE
PROVIDED WITH POSITION INDICATORS AND MAXIMUM
ADJUSTABLE STOPS. ALL VALVES (EXCEPT CONTROL VALVES)
AND STRAINERS MUST BE FULL SIZE OF PIPE BEFORE
REDUCING SIZE TO MAKE CONNECTIONS TO EQUIPMENT OR
CONTROLS.
N
N
GRAPHIC SCALE: 3/32"=1'-0"
8' 0 8' 16' 24'
1 PPI Responses 01.17.25
| Sheets |
| M-101 - FIRST AND SECOND FLOOR PLANS - MECHANICAL |
File details come from the government source that posted it. Updated .